• Title/Summary/Keyword: slow flow

검색결과 336건 처리시간 0.024초

The Analysis of Traffic Flow Characteristics on Moving Bottleneck (연속류 시설의 이동병목구간에서 지체산정방법 -모의실험을 통한 교통류의 평균지체분석-)

  • Kim, Won-Kyu;Jeong, Myeong-Kyu;Kim, Byung-Jong;Seo, Eun-Chae;Kim, Song-Ju
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • 제8권4호
    • /
    • pp.170-181
    • /
    • 2009
  • When a slow-moving vehicle occupies one of the lanes of a multi-lane highway, it often causes queuing behind, unlike one is caused by an actual stoppage on that lane. This happens when the traffic flow rate upstream from the slow vehicle exceeds a certain critical value. This phenomena is called as the Moving Bottleneck, defined by Gazis and Herman (1992), Newell (1998) [3], and Munoz and Daganzo (2002), who conducted the flow estimates of upstream and downstream and considered slow-moving vehicle speed and the flow ratio exceeding slow vehicle and the microscopic traffic flow characteristics of moving bottleneck. But, a study of delay on moving bottleneck was not conducted until now. So this study provides a average delay time model related to upstream flow and the speed of slow vehicle. We have chosen the two-lane highway and homogeneous traffic flow. A slow-moving vehicle occupies one of the two lanes. Average delay time value is a result of AIMSUN[9], the microscopic traffic flow simulator. We developed a multiple regression model based on that value. Average delay time has a high value when the speed of slow vehicle is decreased and traffic flow is increased. Conclusively, the model is formulated by the negative exponential function.

  • PDF

MR Imaging of Slow-flow Using a Flow Phantom (유동모형을 이용한 저속유동의 자기공명영상)

  • Dae-Cheol Cheong;Kyung-Jae Jung;Young-Hwan Lee;Nak-Kwan Sung;Duck-Soo Chung;Ok-Dong Kim;Jong-Ki Kim
    • Investigative Magnetic Resonance Imaging
    • /
    • 제5권2호
    • /
    • pp.116-122
    • /
    • 2001
  • Purpose : To find sensitivity of MRI imaging methods to slow flow phantom study was performed with conventional Spin-Echo, gradient echo based Phase Contrast, fast GRASS, and heavily T2-weighted Fast Spin Echo pulse sequences. Materials and Methods : A siphon driven flow phantom was constructed with a ventriculo-peritoneal shunt catheter and a GE phantom to achieve continuous variable flow. Four different pulse sequences including Spin-Echo, Phase Contrast, GRASS and Heavily T2-weighted Fast Spin Echo were evaluated to depict slow flow in the range from 0.08 ml/min to 1.7 ml/min and to compare signal intensities between static fluid and flowing fluid. Results : In the slow flow above 0.17 ml/min conventional Spin-Echo showed superior apparent contrast between static and flowing fluid while GRASS was more sensitive to the very slow flow below 0.17 ml/mim. It was not accurate to calculate flow and velocity below 0.1 ml/min with a modified PC imaging. Conclusion : Four different MR pulse sequences demonstrated different sensitivity to the range of slow flow from 0.08 ml/min to 1.7 ml/min. This finding may be clinically useful to measure CSF shunt flow or detecting CSF collection and thrombosis.

  • PDF

SLOW VISCOUS FLOW PAST A CAVITY WITH INFINITE DEPTH

  • Kim, D.W;Kim, S.B;Chu, J.H
    • Journal of applied mathematics & informatics
    • /
    • 제7권3호
    • /
    • pp.801-812
    • /
    • 2000
  • Two-dimensional slow viscous flow on infinite half-plane past a perpendicular infinite cavity is considered on the basis of the Stokes approximation. Using complex representation of the two-dimensional Stokes flow, the problem is reduced to solving a set of Fredholm integral equations of the second kind. The streamlines and the pressure and vorticity distribution on the wall are numerically determined.

Two-Dimensional Slow Viscous Flow Due to a Stokeslet Near a Slit (Slit 近傍의 Stokeslet 에 의한 2次元의 느린 粘性流動)

  • 고형종;김문언
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제7권4호
    • /
    • pp.386-391
    • /
    • 1983
  • Two-dimensional slow viscous flow due to a stokeslet near a slit is investigated on the basis of Stokes approximation. Velocity fields and stream function are obtained in closed forms by finding two sectionally holomorphic functions which are determined by reducing the problem to Riemann-Hilbert problems. The force exerted on a small cylinder is calculated for the arbitrary position of the cylinder translating in an arbitrary direction. The features of fluid flow are also investigated.

A Spatial Average Method Using 2nd Order Sampling in Ultrasonic Doppler System (초음파 도플러 시스템에서 2차 샘플링을 이용한 공간축상의 평균 방법)

  • 백광렬
    • Journal of Biomedical Engineering Research
    • /
    • 제16권3호
    • /
    • pp.279-288
    • /
    • 1995
  • Ultrasonic Doppler systems for the purpose of estimating blood flow velocity, blood flow volume, and flow imaging are commonly used due to advantages of non-invasive and real time observation. Specially, the technical developments of color flow mapping (2-D Doppler) systems have made a relatively rapid progress. However, the 2-D Doppler systems have several problems, such as the range ambiguity, low signal to noise ratio, and slow frame rate. The slow frame rate problem is resolved by using the spatial average which is a method to acquire more data samples for mean frequency estimation. In this paper, spatial average method using the 2nd order sampling instead of quadrature sampling is proposed. The experimental results show that the proposed methods have good performance and easy application to the color flow mapping system.

  • PDF

Hydrological Consequences of Converting Forestland to Coffee Plantations and Other Agriculture Crops on Sumber Jaya Watershed, West Lampung, Indonesia

  • Manik, Tumiar Katarina;Sidle, Roy Carl
    • Journal of Forest and Environmental Science
    • /
    • 제34권4호
    • /
    • pp.293-303
    • /
    • 2018
  • Sumber Jaya (54,194 hectares) is a district in West Lampung, Indonesia, located at the upper part of Tulang Bawang watershed. This watershed is one major water resource for Lampung Province, but has become a focal point of discussion because of the widespread conversion of forestland to coffee plantations and human settlements which lead to environmental and hydrological problems. This research aimed to evaluate Sumber Jaya watershed affecting by rapid land use change using hydrological methods as a base for watershed management. Nested catchment structure consisted of eight sub-catchments was employed in this research to assess scaling issues of land use change impacts on rainfall-runoff connections. Six tipping bucket rain gages were installed on the hill slopes of each sub-catchment and Parshall flumes were installed at the outlets of each sub-catchment to monitor stream flow. First, unit hydrograph that expressed the relationship of rainfall and runoff was computed using IHACRES model. Second, unit hydrograph was also constructed from observations of input and response during several significant storms with approximately equal duration. The result showed that most of the storm flow from these catchments consisted of slow flow. A maximum of about 50% of the effective rainfall became quick flow, and only less than 10% of remaining effective rainfall which was routed as slow flow contributed to hydrograph peaks; the rest was stored. Also, comparing peak responses and recession rates on the hydrograph, storm flow discharge was generally increased slowly on the rising limb and decreased rapidly on the falling limb. These responses indicated the soils in these catchments were still able to hold and store rain water.

Assessment of Reynolds Stress Turbulence Closures for Separated Flow over Backward-Facing Step (후향계단을 지나는 박리류에 대한 레이놀즈응력 모델의 성능 평가)

  • ;;Oh, Myung-Taek
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • 제19권11호
    • /
    • pp.3014-3021
    • /
    • 1995
  • This study is carried out in order to evaluate the performances of the Reynolds stress turbulence models such as SSG and GL models in the calculation of separated flow over backward-facing stepp.In addition, two slow return-to-isotropy models, YA and Rotta models combined with rapid part of SSG model are also tested. The finite volume method is used to discretize the governing differential equations, and the power-law scheme is used to approximate the convection terms. The SIMPLE algorithm is used for pressure correction in the governing equations. The results show that SSG model gives the better prediction near the reattachment point than GL model. In cases that the rapid term of SSG model is combined with Rotta and YA slow models, the results show the better predictions of stress components in recirculation zone, but indicate inaccuracy in the predictions of mean velocity.

Evaluation of Turbidity Removal Efficiency on under Flow Water by Pore Controllable Fiber Filtration (공극제어형 섬유사 여과기를 이용한 복류수의 탁도 제거효율 평가)

  • Kim, Jeong-Hyun;Bae, Chul-Ho;Kim, Chung-Hwan;Park, No-Suk;Lee, Sun-Ju;Anh, Hyo-Won;Huh, Hyun-Chul
    • Journal of Korean Society of Water and Wastewater
    • /
    • 제19권2호
    • /
    • pp.135-143
    • /
    • 2005
  • It was evaluated that the effect of turbidity removal by Pore Controllable Fiber Filter(PCF) installed in NS(Naksang) small water treatmant plant(system) using under flow water as raw water in the study. The results of the study are as the followings. Firstly, the removal efficiency of turbidity by PCF without coagulation(in operation mode not using coagulants) was mostly below 20 percent. On the other hand, when operation using proper coagulants, that of turbidity was mostly over 80 percent. Secondly, slow sand filtration after PCF, total turbidity removal efficiency of final treated water was 84.3 percent, and the contribution by PCF was 57.1 percent and that of slow sand filtration was 27.7 percent. Therefore the introduction of PCF as pre-treatment process would be helpful to reduce the loading of high turbidity of slow sand filtration. Thirdly, the results of particle counter measurements showed that when operated PCF with coagulants, fine flocs captured or adsorbed at the pore of PCF were flow out into the effluents from 120 minutes after backwashing because of the increase of headloss of PCF. Therefore the decision of backwashing time should made consideration into the outflow of fine flocs from PCF. Fourth, coagulant dosages on PCF at the same turbidity was largely variable because of the effect of the raw water characteristics and the turbidity increase velocity at rainy days, therefore flexible coagulant dosages should be considered rather than fixed coagulant dosage by the influent jar-test result.

Surgical Treatment of Facial Vascular Malformations (안면부 혈관기형 환자의 수술적 처치)

  • Kim, Soung-Min;Park, Jung-Min;Eo, Mi-Young;Myoung, Hoon;Lee, Jong-Ho;Choi, Jin-Young
    • Korean Journal of Cleft Lip And Palate
    • /
    • 제13권2호
    • /
    • pp.85-92
    • /
    • 2010
  • Vascular malformations (VMs) in the head and neck region are present at birth and grow commensurately with the child, they can result in significant cosmetic problems for the patient, and some may lead to even serious life threatening hemorrhage. Although the molecular mechanisms underlying the formation of these VMs remain unclear, lesions are known to result from abnormal development and morphogenesis. Histologically, there are no evidence of cellular proliferation, but rather progressive dilatation of abnormal channels, which VMs are designated to their prominent channel types such as capillary, venous, lymphatic, arterial, and combined malformations. VMs with an arterial component are rheologically fast-flow, whereas capillary, lymphatic, and venous components are slow-flow. In this article, we review the clinical presentations, diagnosis, and management of VMs of facial regions with author's embolization and surgical treatment cases.

  • PDF

Perturbation Analysis of Stokes Flow in Porous Medium (다공성 매질의 내부유동에 관한 섭동해석)

  • Seong, Kwanjae
    • Journal of Korean Society on Water Environment
    • /
    • 제21권4호
    • /
    • pp.393-397
    • /
    • 2005
  • In this study, flow in a porous medium is analyzed using a computer-extended perturbation series solution. The flow is modelled as a creeping flow in a periodically constricted channel. The channel walls have a sinusoidally varying width and the flow is analyzed in terms of its vorticity and stream functions in the Stokes flow regime. The perturbation series in terms of a small parameter, average width to length ratio, is extended with a computer resulting in purely asymptotic series and Pade summation is used to obtain final results. Resulting flow shows flow separations in the widening section and immobile zones in the widest section of the flow regime with reattachment in the narrowing section. Analysis of the flow separation phenomena resulted in a correlation between the two geometric parameters of the channel walls to predict the onset of flow separation in the Stokes flow regime.