• 제목/요약/키워드: slip flow

검색결과 362건 처리시간 0.025초

비대칭 미세전극을 이용한 동시 혼합 및 펌핑 (Simultaneous mixing and pumping using asymmetric microelectrodes)

  • 김병재;윤상열;이경헌;성형진
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2007년도 추계학술대회
    • /
    • pp.77-83
    • /
    • 2007
  • This paper presents numerical and experimental works for simultaneous pumping and mixing small liquid using asymmetric microelectrode arrays, based on AC electroosmotic flows. To this end, four arrangements of electrode pairs were considered with diagonal/herringbone shapes. Numerical simulations were made of three-dimensional geometries by using the linear theory. The results indicated that the helical flow motions induced by the electrode arrays play a significant role in the mixing enhancement. The pumping performance was influenced by the slip velocity at the center region of the channel compared to that near the side walls. To validate the numerical predictions, the microfluidic devices were made through MEMS. The flow rate was obtained by using micro PIV, increasing the applied frequency. The electrolyte was potassium chloride solution. The flow patterns above electrodes were visualized to see lateral flow for mixing. The experimental results showed good agreements with the numerical predictions.

  • PDF

압축성 마이크로 유동에 관한 기초 연구 (A Fundamental Study of Compressible Micro Flows)

  • 김재형;정미선;김희동;박경암
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.143-146
    • /
    • 2002
  • Recently the micro flows have been received much attention in the applications with regard to Micro Electro Mechanical Systems(MEMS). Such flows are governed by relatively large viscous forces, compared with inetia force, and frequently specified by slip wall boundary conditions. In the present study, computations are applied to investigate the compressible viscous flows through an extremely small channel, and theoretical analyses are conducted using the Fanno flow theory. The axisymmetic, compressible, Wavier-Stokes equations are numerically solved by a fully implicit finite implicit method. The predicted results are validated with previous experimental data available. The results obtained show that for small Reynolds numbers, the viscous frictional force significantly influences the compressible micro channel flows.

  • PDF

섬유강화 플라스틱 복합재의 성형공정에 관한 연구(일방향 섬유강화 복합재의 점도측정 및 유동해석) (A Study on Molding Process Fiber Reinforced Plastic Composites (Flow analysis Measurement of viscosity of Unidirectional Fiber Reinforced Plastic Composites))

  • 조선형;안종윤;이국웅;윤성운
    • 한국공작기계학회논문집
    • /
    • 제10권2호
    • /
    • pp.103-114
    • /
    • 2001
  • During a compression molding process of Unidirectional Fiber Reinforced Plastic Composites, control of filling patterns in mold and distribution of fiber is needed to predict the effects of molding parameters on the flow characteristics. To obtain an excellent product and decide optimum molding conditions, it is important to know the relationship between molding conditions and viscosity. In this study, the anisotropic viscosity of the Unidirectional Fiber Reinforced Plastic Composites is measured by using the parallel plastometer. The model for flow state has been simulated by using the viscosity. The composites is treated as an incompressible New-tonian fluid. The effects of longitudinal/transverse viscosity ration A and slip parameter $\alpha$ on buldging phenomenon and mold filling patterns, are also discussed.

  • PDF

자동차용 열교환기 냉매의 압력 강하 특성에 관한 연구 (A Study on Pressure Drop Characteristics of Refrigerant in Heat Exchanger for Automobile)

  • 임태우;박종운
    • 한국자동차공학회논문집
    • /
    • 제11권2호
    • /
    • pp.119-125
    • /
    • 2003
  • An experiment study on pressure drop was carried out for both an adiabatic and a diabatic two-phase flow with pure refrigerants R134a and Rl23 and their mixtures as test fluids in a uniformly heated horizontal tube. The frictional pressure drop during flow boiling is predicted by using two models; the homogeneous model that assumes equal phase velocity and the separate flow model that allows a slip velocity between two phases. The measured frictional pressure drop was compared to a few available correlations. Homogeneous model considerally underpredicted the present data for mixture as well as pure component in the entire mass velocity ranges employed in the present study, while Friedel correlation was found to satisfactorily correlate the frictional pressure drop data as compared to other correlation.

개방형 원심회전차의 내부유동장에 관한 실험적 연구(1)-무충돌 유입조건에서- (Experimental Study on Flows within an Unshrouded Centrifugal Impeller Passage(I)-At the Shockless Condition-)

  • 김성원;조강래
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2261-2270
    • /
    • 1995
  • Flow patterns were measured in an unshrouded centrifugal impeller. The flow rate in measurements was fixed at the value corresponding to a nearly zero incidence at the blade inlet. By using a single slanted hot-wire probe and a Kiel probe mounted on the impeller hub disk, the 3-D relative velocities and the rotary stagnation pressures were measured in seven circumferential planes from the inlet to the outlet of the impeller rotating at 700rpm, which diameter is 0.39 meter, and the static pressures and the slip factor at the impeller outlet were calculated from the measured values. From the measured data, the primary/secondary flows, the leakage flows, the wake-jet flows, static pressure distribution on blade surfaces and the wake production mechanism in the impeller passage were investigated.

초음속 유동을 통한 EDISON 성능 평가 (Evaluation of EDISION's performance through supersonic flow analysis)

  • 정경선;신영진
    • EDISON SW 활용 경진대회 논문집
    • /
    • 제2회(2013년)
    • /
    • pp.337-342
    • /
    • 2013
  • 이번 연구에서는 de Laval nozzle를 이용하여 다양한 유체해석 모델과 프로그램을 비교하여 그 성능을 파악하였다. de Laval nozzle은 eigenvalue에 의해 eigenvector값이 '-'와 '+'값을 동시에 갖는 물리현상을 내포하고 있으며, 압력조건에 따라 내부에서 Normal shock이 발생하게 된다. 이러한 non-linearity를 현재 우리가 주로 사용하고 있는 상용프로그램(cfx, fluent)과 EDISON, 직접 코딩한 프로그램(Matlab이용)이 얼마나 잘 표현하는지 알아보았다. 그 결과 Van Leer Vector Splitting을 이용할 경우 물리현상을 제일 잘 표현 하였다. 또한 난류 유동(Turbulence flow)을 고려하게 될 경우, Mesh가 Boundary layer를 표현할 정도로 정밀하지 못하다면 제대로 된 해석 결과를 얻을 수 없었으며, Wall 근처에서 Non-slip condition에 의해 Vortex가 형성되고, 이 Vortex가 Back flow를 유도하여 해가 수렴하는데 방해를 하게 됨을 알 수 있었다. 이를 방지하기 위해서는 유동이 잘 표현될 수 있도록 적절한 Computational environment를 형성해 주는 것이 매우 중요하다.

  • PDF

Numerical Simulation of the Effect of Finite Diaphragm Rupture Process on Micro Shock Tube Flows

  • ;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2012년도 제38회 춘계학술대회논문집
    • /
    • pp.309-317
    • /
    • 2012
  • Recent years have witnessed the use of micro shock tube in various engineering applications like micro combustion, micro propulsion, particle delivery systems etc. The flow characteristics occurring in the micro shock tube shows a considerable deviation from that of well established conventional macro shock tube due to very low Reynolds number and high Knudsen number effects. Also the diaphragm rupture process, which is considered to be instantaneous process in many of the conventional shock tubes, will be crucial for micro shock tubes in determining the near diaphragm flow field and shock formation. In the present study, an axi-symmetric CFD method has been applied to simulate the micro shock tube, with Maxwell's slip velocity and temperature jump boundary conditions. The effects of finite diaphragm rupture process on the flow field and the shock formation was investigated, in detail. The results show that the shock strength attenuates rapidly as it propagates through micro shock tubes.

  • PDF

이동식 플랫폼에서 발사되는 비행체의 날개 전개 공력 하중에 관한 연구 (A Study on Aerodynamic Loads of a Deploying Wing Launched from a Mobile Platform)

  • 이영환
    • 한국군사과학기술학회지
    • /
    • 제22권3호
    • /
    • pp.353-359
    • /
    • 2019
  • In this study, a aerodynamic loads prediction to design a deploying device of folded fin was introduced. In general, resultant flow conditions around the fin are used to obtain deploying moments and required energy. However, when it comes to the air vehicles launched from a mobile platform, more specific flow conditions can be provided. With the conditions, the design criteria can be calculated more realistically. In this study, therefore, aerodynamic moments induced by aerodynamic loads and energy required in deployment were calculated using wind-over-deck(WOD) velocity, combination of a platform velocity and a wind velocity. For the calculation, wind tunnel test was conducted on various angle of attack, side slip angles, and folding angles. It was found that the aerodynamic moments and the energy required in deployment using the non-uniform flow due to the velocity components were less than those using the uniform flow without the components.

친수성 및 소수성 마이크로 노즐 내 유동 ${\mu}-PIV$ 연구 (${\mu}-PIV$ Visualization of Flow in Hydrophilic and Hydrophobic Micro-nozzle)

  • 변도영;김지훈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제27회 추계학술대회논문집
    • /
    • pp.15-18
    • /
    • 2006
  • 최근 미소기전시스템(MEMS)를 개발함에 있어 마이크로 크기의 유동가시화는 중요한 문제이다. 특히 유체와 고체표면의 상호작용에 있어 표면의 친수성과 소수성의 성질은 미소유체를 조절 가능케 하는 핵심적인 역할이다. 본 연구에서는 마이크로 채널 내 표면을 개질하여 친수성 및 소수성의 벽면 경계조건 습윤도를 측정하였고, 또한 micro-PIV를 이용하여 벽면 근처에서의 속도 분포를 분석하였다.

  • PDF

공력음향학적 특성을 고려한 시로코 팬의 설계 방법 (Design Method of the Sirocco Fan Considering Aeroacoustic Performance Characteristics)

  • 이찬
    • 한국유체기계학회 논문집
    • /
    • 제13권2호
    • /
    • pp.59-64
    • /
    • 2010
  • A design method of Sirocco fan is developed for constructing 3-D impeller and scroll geometries, and for predicting both the aerodynamic performance and the noise characteristics of the designed fan. The aerodynamic blading design of fan is conducted by blade angle, camber line determinations and airfoil thickness distribution, and then the scroll geometry of fan is designed by using logarithmic spiral. The aerodynamic performance of designed fan is predicted by the meanline analysis with flow blockage, slip and pressure loss correlations. Based on the predicted performance data, fan noise is predicted by two models for cutoff frequency and broadband noise sources. The present predictions for the performance and the noise level of actual fans are well agreed with measurement results.