• 제목/요약/키워드: slip capacity

검색결과 207건 처리시간 0.025초

THE HYDROMAGNETIC FLOW BETWEEN ECCENTRIC CYLINDERS WITH VELOCITY SLIP AT THE CYLINDER WALLS

  • Meena, S.;Kandaswamy, P.
    • Journal of applied mathematics & informatics
    • /
    • 제6권2호
    • /
    • pp.487-502
    • /
    • 1999
  • The hydrodynamic flow between two eccentric cylinders is examined for small values of modified Reynolds number porosity parameter and the non-dimensional slip velocity parameter in the presence of a radial magnetic field. The stream function and the pres-sure distribution are calculated and the results are presented graph-ically.

합판과 목재사이 못 접합에 있어서 하중 속도에 대한 Damping과 강성 (stiffness) (Damping and Stiffness of Nailed Joints between Wood and Plywood : Response to Loading Rate)

  • 차재경
    • Journal of the Korean Wood Science and Technology
    • /
    • 제20권1호
    • /
    • pp.72-78
    • /
    • 1992
  • 지진과 관련있는 하중 속도에서 damping을 측정하기 위하여 합판과 목재 사이에 한개의 못을 사용한 접합에 대하여 조사 했다. 조사된 하중은 sine function 의 15Hz와 ASTM하중 속도 사이에서 행했다. Damping 율은 4Hz까지의 하중 속도에서는 증가를 보였으며 그후 15Hz 까지는 점진적으로 감소하였다. 강성은 높은 하중 범위에서 slip moduli가 지속적으로 증가 하였다. 낮은 하중 범위에서 2.5Hz까지 증가 하였으며 그후는 감소 하였다. Damping 율과 slip modulus는 하중 속도와 상관 관계가 낮은 반면 work capacity와 dissipated energy는 높은 상관 관계를 보았다.

  • PDF

Bond-slip constitutive model of concrete to cement-asphalt mortar interface for slab track structure

  • Su, Miao;Dai, Gonglian;Peng, Hui
    • Structural Engineering and Mechanics
    • /
    • 제74권5호
    • /
    • pp.589-600
    • /
    • 2020
  • The bonding interface of the concrete slab track and cement-asphalt mortar layer plays an important role in transferring load and restraining the track slab's deformation for slab track structures without concrete bollards in high-speed railway. However, the interfacial bond-slip behavior is seldom considered in the structural analysis; no credible constitutive model has been presented until now. Elaborating the field tests of concrete to cement-asphalt mortar interface subjected to longitudinal and transverse shear loads, this paper revealed its bond capacity and failure characteristics. Interfacial fractures all happen on the contact surface of the concrete track slab and mortar-layer in the experiments. Aiming at this failure mechanism, an interfacial mechanical model that employed the bilinear local bond-slip law was established. Then, the interfacial shear stresses of different loading stages and the load-displacement response were derived. By ensuring that the theoretical load-displacement curve is consistent with the experiment result, an interfacial bond-slip constitutive model including its the corresponding parameters was proposed in this paper. Additionally, a finite element model was used to validate this constitutive model further. The constitutive model presented in this paper can be used to describe the real interfacial bonding effect of slab track structures with similar materials under shear loads.

Static behaviour of multi-row stud shear connectors in high- strength concrete

  • Su, Qingtian;Yang, Guotao;Bradford, Mark A.
    • Steel and Composite Structures
    • /
    • 제17권6호
    • /
    • pp.967-980
    • /
    • 2014
  • In regions of high shear forces in composite bridges, headed stud shear connectors need to be arranged with a small spacing in order to satisfy the design requirement of resisting the high interface shear force present at this location. Despite this, studies related to groups of headed studs are somewhat rare. This paper presents an investigation of the static behaviour of grouped stud shear connectors in high-strength concrete. Descriptions are given of five push-out test specimens with different arrangements of the studs that were fabricated and tested, and the failure modes, load-slip response, ultimate load capacities and related slip values that were obtained are reported. It is found that the load-slip equation given by some researchers based on a single stud shear connector in normal strength concrete do not apply to grouped stud shear connectors in high-strength concrete, and an algebraic load-slip expression is proposed based on the test results. Comparisons between the test results and the formulae provided by some national codes show that the equations for the ultimate capacity provided in these codes are conservative when used for connectors in high-strength concrete. A reduction coefficient is proposed to take into account the effect of the studs being in a group.

바텀애시 골재 기반 경량 콘크리트의 전단마찰거동에 대한 기포 혼입률의 영향 (The effect of Foam Volume Ratio on the Shear Friction Behavior of Bottom Ash Based Lightweight Aggregate Concrete)

  • 김종원;양근혁;문주현
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 봄 학술논문 발표대회
    • /
    • pp.183-184
    • /
    • 2020
  • This study evaluated the effect of foam volume ratio on shear friction behavior of bottom ash based lightweight aggregate concrete (LWA_BA). The LWA_BA with different foam volume ratio ranged between 8 and 25 MPa for compressive strength(fck), 17.3~62.5 kN for shear capacity at first shear crack(Vcr), 31.1~73.8 kN for shear friction capacity(Vn), and 0.01~0.03 mm for slip at maximum peak load(S0). fck decreased with increase in the foam volume ratio, showing that this trend was also observed in Vcr, Vn, and S0.

  • PDF

Stud connection in composite structures: development with concrete age

  • Chengqian Wen;Guotao Yang
    • Steel and Composite Structures
    • /
    • 제47권6호
    • /
    • pp.729-741
    • /
    • 2023
  • As the most popular shear connection in composite structures, mature concrete has been widely investigated by considering mechanical properties of stud connectors (SCs) embedded. To further enhance the fabrication efficiency of composite structures and solve the contradiction between construction progress and structural performance, it is required to analyze the shear performance of stud connections of composite structures with different concrete ages. 18 typical vertical push-out tests were carried out on stud shear connectors at concrete ages of 7 days, 14 days, and 28 days. Also, the effects of concrete age, stud spacing and stud diameter on the shear capacity, connection stiffness and failure mode of the connectors were studied. A new relationship expression of load-slip for SCs with various concrete ages was proposed. The existing design code for the SCs shear strength was evaluated according to the experimental data, and a more practical prediction equation for the shear capacity of SCs with different concrete ages was established. A great agreement was observed between the experimental and theoretical results, which can provide a reference for engineering practices.

반구형 공기동압베어링의 정적 특성 및 설계 (Static Characteristics and Design of Hemispherical Aerodynamic Bearing)

  • 김승곤;김준영;최환영
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1997년도 제26회 추계학술대회
    • /
    • pp.217-224
    • /
    • 1997
  • Static characteristics of hemispherical aerodynamic bearing is studied theoretically. In this paper nonlinear equation of second order considering compressibility and slip effect of air is calculated by Newton-Raphson method. Results indicate that axial load capacity has maximum value when the inclination angle of groove is about 30$\circ$, the ratio of groove clearance to ridge clearance is two. We also present the design method of hemispherical Aerodynamic bearing based on it's load capacity taking into account manufacturing and assembling viewpoint.

  • PDF

긴장재의 슬립거동을 고려한 원자로 격납건물의 비선형 해석 (Nonlinear Analysis of Prestressed Concrete Containment Structures Considering Slip Behavior of Tendons)

  • 곽효경;김재홍;김선훈;정연석
    • 한국전산구조공학회논문집
    • /
    • 제18권4호통권70호
    • /
    • pp.335-345
    • /
    • 2005
  • 이 논문에서는 프리스트레스트 콘크리트 구조로 건설된 원자로 격납건물의 극한내압평가를 위해 비선형 유한요소해석을 수행하였다. 특히, 상용프로그램 사용 시 콘크리트와 긴장재의 완전부착 가정으로 인해 고려할 수 없었던 콘크리트와 긴장재 사이의 슬립효과를 모사할 수 있는 알고리즘을 개발하였다. 부착된 긴장재의 경우 부착-슬립효과를 기초로 유도된 겉보기 항복응력으로 두 재료의 상호거동을 모사할 수 있고, 비부착된 긴장재의 경우 반복해석에 의해 긴장재 전체 길이방향으로의 슬립효과를 모사할 수 있다. 개발된 알고리즘을 이용하여 도출된 긴장재의 응력-변형률 관계를 이용하여 격납건물의 축소모델에 대한 비선형 해석을 수행하였고, 수행한 결과를 바탕으로 격납건물의 극한내압은 가압중수로형과 가압경수로형 모두 설계압력의 약 3배 이상 구조적 여유가 있음을 확인하였다.

개선된 부착슬립 모델을 적용한 부분 CFST 기둥의 수치해석 (Numerical Approach for a Partial CFST Column using an Improved Bond-Slip Model)

  • 황주영;곽효경
    • 한국전산구조공학회논문집
    • /
    • 제33권3호
    • /
    • pp.153-158
    • /
    • 2020
  • 본 논문에서는 부분 CFST (concrete-filled steel tube) 기둥에 대한 수치해석적 저항력 평가 방법에 대해 소개하고 있다. 기존 RC(reinforced concrete) 기둥에서 소성힌지가 발생할 것으로 예상되는 부분을 강관으로 보강함으로써 완전 CFST 기둥보다는 적은 재료를 사용하여 비슷한 휨 모멘트 저항력을 가지는 부분 CFST 기둥의 디자인 컨셉을 제시하였다. 부분 CFST 기둥에서 외부 강관과 내부 콘크리트 사이의 계면에서 거동을 수치해석적으로 모사하기 위해 개선된 부착슬립모델을 적용한 유한요소모델을 구축하고, 이중곡률 휨-압축시험결과와 비교를 통해 타당성을 검증하였다. 검증된 수치모델을 바탕으로 매개변수 연구를 통해서 P-M 상관도를 그려 단면 조건에 따른 최대 저항력을 평가하였다. 또한, 강관 두께별로 필요 보강길이를 산출하고, 보강 조건에 따른 부분 CFST 기둥에서의 파괴메커니즘을 분석하였다.

테이블 중량 감소 효과에 따른 스틱슬립 개선에 관한 연구 (A Study on Improvement of the Stick-slip Induced an Effect Decrease of the Table Weight)

  • 홍성오;조규재
    • 한국공작기계학회논문집
    • /
    • 제11권5호
    • /
    • pp.7-14
    • /
    • 2002
  • In order to achieve high precision machine tools, the research for performance enhancement of feed drive systems is required. Development of the high speed feed drive system has been a major issue for the past few decades in machine tool indestries. Because table levitation system decrease the table weight, an effect of reaction by weight is minimized and lost motion can be removed at maximum. In case fled system is designed with drive motor, ball screw and support bearing load capacity selection, an effect of decrease of the table weight exist. So, the table weight through an effect of decrease call it into the realization of cost down. Stick-slip friction has a great influence on the contouring accuracy of CNC machine tools. In this paper table levitation system has been developed for the stick-slip in a fled drive systems.