• Title/Summary/Keyword: slice position

Search Result 47, Processing Time 0.028 seconds

Development of a Moldboard Plow to Invert Furrow Slice at the Same Position (토양의 제자리 반전을 위한 몰드보드 플라우의 개발)

  • 이규승;박원엽;권병기
    • Journal of Biosystems Engineering
    • /
    • v.29 no.1
    • /
    • pp.9-20
    • /
    • 2004
  • On the basis of design theory of soil inversion, two types of moldboard plow with secondary soil mover was designed and constructed to invert furrow slice at same position with furrow bottom. A series of soil bin experiment was carried to investigate the performance of prototypes. First prototype of new concept plow showed two kinds of problems during the preliminary experiment. For the plowing depth of 6cut the prototype did not invert the furrow slice, instead it just cut furrow bottom and the furrow slice returned to the original position. For the plowing depth of 8cm, there was soil clogging problem at the rear part of plow. From the above results it was concluded that the first prototype can not be used for the inversion of furrow slice at same position with furrow bottom. Second prototype could invert furrow slice at the same position with furrow bottom, but the performance was affected by soil moisture content soil hardness and plowing speed very much. For the higher soil moisture content, for the higher soil hardness and higher plowing speed, the prototype showed higher soil inversion performance. For the second prototype the inversion ratio was almost 100%, inversion angle was in the range of 90 to 100 degree and side displacement was less than 4 cm. But the furrow slice was not continuous, it was cut in the length of 30 to 40 cm. The reason why the furrow slice was cut in that length is blamed for the design of moldboard surface. The specific draft of prototype was in the range of 37.24 kN/㎡ to 42.14 kN/㎡ this value is a little higher than that of the conventional plow, or from 30.38 kN/㎡ to 33.32 kN/㎡. But the difference was not so big. The inversion performance of the second prototype for the field experiment was much better than that of soil bin experiment due to the better soil and operational conditions. Sticky and compacted soil conditions, and higher plowing speed was suitable for the plowing operation of the second prototype

The Automatic Detection of Inner Boundary on EBCT Images for Airway (기도에 대한 EBCT 영상에서의 내벽 윤곽선 자동검출)

  • 김명남;조진호
    • Journal of Korea Multimedia Society
    • /
    • v.6 no.6
    • /
    • pp.991-999
    • /
    • 2003
  • In this paper, we proposed image acquisition techniques that can reflect anatomical airway information lot breath change by EBCT Also, we proposed new method to detect automatically boundary of inner airway for acquired slice images using this image acquisition technology. We confirmed that new method detects boundary of inner airway effectively through computer simulation that apply image data about each slice position of airway. And, we could see change for cross section area of inner airway by time change. Therefore, we think that proposed method can utilize on quantitative analysis in clinical field.

  • PDF

Effect of the slice thickness and the size of region of interest on CT number (상층두께와 관심영역의 크기 변화가 CT 번호에 미치는 영향)

  • Lee Ji-Youn;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.31 no.2
    • /
    • pp.85-91
    • /
    • 2001
  • Purpose: To evaluate the effect of the slice thickness and the size of region of interest (ROI) on CT number using quantitative CT phantom Materials and Methods: The phantom containing 150 mg/cc, 75 mg/cc and 0 mg/cc calcium hydroxyapatite was scanned with 1, 3, 5 and 10 mm slice thicknesses by single energy quantitative computed tomography (QCT). CT numbers were measured on center position of the phantom. Shape of ROI was circular and sizes were 1, 3, 5, 11, 16, 21, 26 and 33 mm². ANOVA and Tukey's multiple comparison method were performed for statistical comparison of CT numbers according to different slice thicknesses. Coefficient of variation of CT number measured in each size of ROI was evaluated in same slice thickness. Results : CT numbers had statistically significant difference according to slice thicknesses (p<0.05). As the slice thickness increased, CT number also increased. As the density of phantom became lower and the size of ROI became smaller, the coefficient of variation of CT number increased. When the size of ROI was more than 11 mm² in 1 mm slice thickness, 5 mm² in 3 mm slice thickness and 3 mm² in 5 mm slice thickness, the coefficient of variation became consistent. In 10 mm slice thickness, the size of ROI had little effect on the coefficient of variation. Conclusion: CT number had variation according to the slice thickness and the size of ROI although the object was homogeneous. The slice thickness and the size of ROI are critical factors in precision of the CT number measurements.

  • PDF

Study on Slice Sensitivity Profile and Reconstruction Resolution on Helical CT System (Helical CT 시스템에 있어 Slice Sensitivity Profile과 Reconstruction Resolution에 관한 연구)

  • Yoon, Han-Sik
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.15-20
    • /
    • 1997
  • Unlike conventional CT scan, the helical CT scan uses continuous rotating CT equipment with a slip ring to move the patient's coach at a constant speed while continuously scanning. Slice sensitivity profiles in the Z-position(SSPz) using the conventional X-ray CT have a shape similiar to a rectangular wave, which slightly spreads out into plains below the mountain. However, in the helical CT, with an expansion of the base, the rectangular shape collapses and a mouatain-like shape can be seen. We need to investigate the fellowing factors in helical CT scanning;the ability to scan along the axis of the body, effective slice width, slice shape and the precision of coach velocity, Helical scanning with sprial X-ray track is different from the conventional scanning in terms of the principle of image reconstruction performed. We believe that the problems in helical scanning can be solved by understanding new the special parameters such as the bed moving speed and the interval of image reconstruction.

  • PDF

Analysis of the Dental Implants MRI Artifacts by Using the ACR Phantom (ACR 팬텀을 이용한 치아 임플란트 자기공명영상 인공물 분석)

  • Shin, Woon-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.629-635
    • /
    • 2016
  • ACR phantom for quality control of magnetic resonance imaging equipment can evaluate magnetic resonance imaging picture quality through various structures within the phantom. In this study, percent Signal Ghosting and Slice position accuracy of imaging could be analyzed by attaching implant and the wire for correction of tooth using ACR phantom in Head coil of 3.0T equipment. In the T1 weighted imaging of the first slice and the eleventh slice of implant, the slice position accuracy appeared to be good in ingress bandwidth 300, and it was good in ingress bandwidth 130 when wire for correction was attached. Percent Signal Ghosting in the seventh slice of SE T1 weighted imaging, implant and wire for correction added all appeared to be good when ingress bandwidth was 230. It is thought that in case of implant dental prosthesis patients in brain exam using magnetic resonance imaging, optimum image can be obtained by changing ingress bandwidth.

IMRT optimization on multiple slice using gradient based algorithm (Gradient based algorithm을 이용한 multiple slice IMRT optimization)

  • Lee, Byung-Yong;Cho, Byung-Chul;Lee, Seok;Jung, Won-Kyun;An, Seung-Do;Choi, Eun-Kyung;Kim, Jong-Hoon;Jang, Hye-Sook
    • Progress in Medical Physics
    • /
    • v.9 no.4
    • /
    • pp.201-206
    • /
    • 1998
  • IMRT optimization method on multiple slice has been developed by using gradient based algorithm. On about 10-30 CT slices including treatment region of a patient, dose optimization has been performed slice by slice to meet the condition that each organ should be exposed below maximum tolerable doses and that the tumor dose within the range of 100$\pm$5 %. Field size was limited to 8$\times$8 cm$^2$ and in this condition, beam divergence was not taken into account to calculate dose distribution. Total dose distribution was calculated by superposing each beamlet whose dose distribution had been precalculated. In order to investigate beam number dependency, dose optimization was performed for one, three, five, seven, and nine coplanar beams and then each optimization index was evaluated. It is found that optimization time was proportional to number of slices to be optimized, and the most efficient plan was obtained from the case of three-to-seven incident beams with respect to calculation time and optimization index. In conclusion, dose optimization of multiple slice was able to be obtained by repeating dose optimization of single slice under condition that the beam size is not too large to ignore beam divergence. And it turns out that result of dose optimization was so sensitive to the position of isocenter that some method to optimize isocenter position is needed to improve it.

  • PDF

Unscented Kalman Snake for 3D Vessel Tracking

  • Lee, Sang-Hoon;Lee, Sanghoon
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.1
    • /
    • pp.17-25
    • /
    • 2015
  • Purpose In this paper, we propose a robust 3D vessel tracking algorithm by utilizing an active contour model and unscented Kalman filter which are the two representative algorithms on segmentation and tracking. Materials and Methods The proposed algorithm firstly accepts user input to produce an initial estimate of vessel boundary segmentation. On each Computed Tomography Angiography (CTA) slice, the active contour is applied to segment the vessel boundary. After that, the estimation process of the unscented Kalman filter is applied to track the vessel boundary of the current slice to estimate the inter-slice vessel position translation and shape deformation. Finally both active contour and unscented Kalman filter are inter-operated for vessel segmentation of the next slice. Results The arbitrarily shaped blood vessel boundary on each slice is segmented by using the active contour model, and the Kalman filter is employed to track the translation and shape deformation between CTA slices. The proposed algorithm is applied to the 3D visualization of chest CTA images using graphics hardware. Conclusion Through this algorithm, more opportunities, giving quick and brief diagnosis, could be provided for the radiologist before detailed diagnosis using 2D CTA slices, Also, for the surgeon, the algorithm could be used for surgical planning, simulation, navigation and rehearsal, and is expected to be applied to highly valuable applications for more accurate 3D vessel tracking and rendering.

Optimal 3-D Packing using 2-D Slice Data for Multiple Parts Layout in Rapid Prototyping (신속시작작업에서 2차원 단면데이터를 이용한 3차원 물체의 최적자동배치를 위한 알고리즘의 개발)

  • 허정훈;이건우;안재홍
    • Korean Journal of Computational Design and Engineering
    • /
    • v.2 no.3
    • /
    • pp.195-210
    • /
    • 1997
  • In Rapid Prototyping process, the time required to build multiple prototype parts can be reduced by packing several parts optimally in a work volume. Interactive arrangement of the multiple parts is a tedious process and does not guarantee the optimal placement of all the parts. In this case, packing is a kind of 3-D nesting problem because parts are represented by STL files with 3-D information. 3-D nesting is well known to be a problem requiring an intense computation and an efficient algorithm to solve the problem is still under investigation. This paper proposes that packing 3-D parts can be simplified into a 2-D irregular polygon nesting problem by using the characteristic of rapid prototyping process that the process uses 2-dimensional slicing data of the parts and that slice of the STL parts are composed of polygons. Our algorithm uses no-fit-polygon (NFP) to place each slice without overlapping other slices in the same z-level. The allowable position of one part at a fixed orientation for given parts already packed can be determined by obtaining the union of all NFP's that are obtained from each slice of the part. Genetic algorithm is used to determine the order of parts to be placed and orientations of each part for the optimal packing. Optimal orientation of a part is determined while rotating it about the axis normal to the slice by finite angles and flipping upside down. This algorithm can be applied to any rapid prototyping process that does not need support structures.

  • PDF

Mitigation Techniques of Channel Collisions in the TTFR-Based Asynchronous Spectral Phase-Encoded Optical CDMA System

  • Miyazawa, Takaya;Sasase, Iwao
    • Journal of Communications and Networks
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • In this paper, we propose a chip-level detection and a spectral-slice scheme for the tunable-transmitter/fixed-receiver (TTFR)-based asynchronous spectral phase-encoded optical codedivision multiple-access (CDMA) system combined with timeencoding. The chip-level detection can enhance the tolerance of multiple access interference (MAI) because the channel collision does not occur as long as there is at least one weighted position without MAI. Moreover, the spectral-slice scheme can reduce the interference probability because the MAI with the different frequency has no adverse effects on the channel collision rate. As a result, these techniques mitigate channel collisions. We analyze the channel collision rate theoretically, and show that the proposed system can achieve a lower channel collision rate in comparison to both conventional systems with and without the time-encoding method.