• Title/Summary/Keyword: slab vibration

Search Result 288, Processing Time 0.026 seconds

Performance Evaluation On Floating Rail Track System (레일부유궤도 시스템에 대한 성능 평가)

  • Kim Soon-Cheol;Kang Jeong-Ok;Ji Yune-Bae;Han Kwang-Seob;Jeon Byung-Chan
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.756-762
    • /
    • 2004
  • Up to now, the only way is Floating Slab Track System, which cuts off vibration by installing spring between concrete slab and ground for the lines of particularly requiring attenuating vibration. The weak point of Floating Slab Track System is large increase of construction cost because normally the structure is getting bigger. In regards to this matter, Floating Rail Track System has been developed, which cuts off vibration by floating the first cause of vibration rail, and the system is in operation. In the thesis, the application of new attenuating vibration track system has been confirmed by studying theoretical background of Floating Rail Track System and evaluating dynamic deflection of track and attenuating of noise and vibration performance through various measurements from laboratory tests and site inspection.

  • PDF

A Study on the Control of the Floor Vibration in a Research Building (연구소(硏究所) 건물(建物)의 슬래브 진동(振動) 성능개선(性能改善) 연구(硏究))

  • Baik, In-Whee;Kang, Ho-Sub;Sohn, Young-Kyoo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.3
    • /
    • pp.75-82
    • /
    • 2007
  • A vibration in the building occurs by influences of the facility equipment and the structural system. As the building recently becomes higher and bigger, the vibration in the floor slab is issued. Specially, the vibration with $4{\sim}8Hz$ frequency is harder to control than any other range of frequency. This vibration easily affects human sensibility and often makes the resonance phenomenon by corresponding with the floor slab's natural frequency when people and heavy equipments move. Moreover, the permission regulations for the vibration of the building are established by building's purposes. However, it is not subdivided in detail and sometimes ambiguous to each client. Even though the vibration could cause negative influences in a research building, there is not the vibration criterion for a research building. Therefore, it is necessary to set up its own vibration criterion with the client before building and to keep checking this vibration criterion under the construction. This study proposes the reasonable control methods and the vibration criterion for floor slab's vibration which are adapted to the R4-project. The R4-project is a research building and a high-rise building also. Accordingly, this study could help to the next similar project in the design and the construction phase.

The Development of a Floating Slab Track to Isolation System (플로팅 슬래브 궤도용 방진시스템 개발)

  • Park, Sang Gon;Chun, Chong Keun;Lee, Gyu Seop;Jang, Seung Yup
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.2
    • /
    • pp.112-122
    • /
    • 2013
  • Recently the construction of stations under railway lines and railway sections passing through central area of cities are increasing, calling for an urgent establishment of countermeasures against railway vibration and its subsequent second-phase noise. Of technology developed up to now, the most efficient countermeasure is the floating slab track, a track system isolated from the sub-structure by springs. Unfortunately, however, the system design technology and technology for key components have not yet developed in Korea. As such, in this study, the analysis and design technology of floating slab track and its vibration isolator technology can be achieved. In preparation for future demands, it is expected to raise awareness for the need of technology self-support and to make a meaningful contribution to mitigating vibration and noise produced by the next-generation high-speed railway.

Field performance evaluation of a Floating Slab Track to Isolation System (플로팅 슬래브 궤도용 방진시스템 현장성능 평가)

  • Park, Sang Gon;Koo, Hyung wook;Han, Hyun Hee;Chun, Chong Keun;Jang, Seung Yup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.352-357
    • /
    • 2014
  • Recently the construction of stations under railway lines and railway sections passing through central area of cities are increasing, calling for an urgent establishment of countermeasures against railway vibration and its subsequent second-phase noise. Of technology developed up to now, the most efficient countermeasure is the floating slab track, a track system isolated from the sub-structure by springs. Developed in this study, anti-vibration device for floating slab track (HLRM-High Load Rubber Mount) Haman station affiliated to the primary measurement was conducted in October 2012, one year after the second measurement after 2013 to be carried out in November and we want to change that. It is expected to raise awareness for the need of technology self-support and to make a meaningful contribution to mitigating vibration and noise produced by the next-generation high-speed railway.

  • PDF

The Development of a Floating Slab Track to Isolation System (플로팅 슬래브 궤도용 방진시스템 개발)

  • Park, Sang Gon;Koo, Hyung Wook;Han, Hyun Hee;Chun, Chong Keun;Jang, Seung Yup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.636-641
    • /
    • 2013
  • Recently the construction of stations under railway lines and railway sections passing through central area of cities are increasing, calling for an urgent establishment of countermeasures against railway vibration and its subsequent second-phase noise. Of technology developed up to now, the most efficient countermeasure is the floating slab track, a track system isolated from the sub-structure by springs. Unfortunately, however, the system design technology and technology for key components have not yet developed in Korea. As such, in this study, the analysis and design technology of floating slab track and its vibration isolator technology can be achieved. In preparation for future demands, it is expected to raise awareness for the need of technology self-support and to make a meaningful contribution to mitigating vibration and noise produced by the next-generation high-speed railway.

  • PDF

A Study on the Dynamic Analysis of One-way Hollow Slab Using Equivalent Plate Element (등가플레이트 요소를 이용한 일방향 중공슬래브의 동적해석에 관한 연구)

  • Kang, Joo-Won;Lim, Jun-Ho;Chae, Seoung-Hun;Kim, Gee-Cheol;Seok, Keun-Young
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.5
    • /
    • pp.447-454
    • /
    • 2012
  • Considering that the weight of a hollow slab system is not increased with an incremental increase in its thickness, and that the flexural stiffness of a hollow slab is not significantly lower than that of a general slab, there has been a growing need for hollow slab system, because long span structures are in great demand. In a long span structure, the problem of vibration of floor slabs frequently occurs, and the dynamic characteristics of a hollow slab system are quite different from the conventional floor system. It is required to investigate the safety and the serviceability of hollow slab. Therefore, there exists a necessity for accurate vibration analysis. Hollow slab should be modeled by refined mesh for accurate vibration analysis. For the efficiency of the Eigenvalue Analysis, an equivalent plate slab model when can relatively precisely represent the dynamic behavior of a one-way hollow slab system is used. In conclusion, equivalent plate models relatively precisely presented the dynamic characteristics of one-way hollows.

A Study on the Safety and Usability of University Dormitory Buildings (대학 기숙사 건물의 안전성 및 사용성 평가 연구)

  • Chae, Kyoung-Hun;Heo, Seok-Jae;Hur, Moo-Won
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.26 no.2
    • /
    • pp.3-10
    • /
    • 2019
  • This study evaluated the vibration use and safety of students living in the dormitories on the 12th and 14th floors by feeling uncomfortable. The measurement method was to measure the acceleration due to free vibration and single - person walking. The slab stiffness was then calculated, and the usability and safety were compared according to international standards. The natural frequency of the slab was 6.8 Hz. The natural frequency of a typical slab is around 15Hz. Therefore, the evaluation slab is judged as a flexible floor structure. It is considered that there is a high possibility of resonance in the middle of daily life because of low natural frequency and near harmonic component of walking vibration. As a result, the RMS acceleration level is within the tolerance range defined by ISO 10137 code, but the 13th floor exceeds the reference limit, so that a sensitive person could detect the vibration somewhat in the lying position.

A Study on the Vibration Character of Floor Slab in Apartment House (공동주택 바닥 슬라브의 진동 특성에 관한 연구)

  • Pakr, Myung-Kil;Ham, Jin-Sik
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2003.11a
    • /
    • pp.77-81
    • /
    • 2003
  • This paper is contents about vibration character that produce floor slab make up of concrete when played striking at each location. An experiment was achieved in apartment house just before occupancy which build newly to 100m$^2$ scale. Vibration level plays striking in whole 9 places and measured vibration character of x, y, z direction. As the result, vibration level of verticality direction showed high than horizontality direction.

  • PDF

Efficient Analysis Models for Vertical Vibration of 3-Dimensional Structures (효율적인 3차원 구조물의 연직진동 해석)

  • 안상경
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.10a
    • /
    • pp.143-150
    • /
    • 1997
  • Generally, the problem of vertical vibration of structure is generated slab. Analysis of space framed structures with slab for vertical vibration requires more efficient modeling and analysis technique, because number of elements lead to more complicated model with many degree of freedom which requires large amount of computing resources for dynamic analysis. This paper propose an efficient analysis method for vertical vibration of space framed structure with slab. At first, proposed model is selected minimum joints and degree of freedom which are acquired sufficient dynamic response to the vertical vibration. Secondly, super-elements that are made a number of element are used for simple input data and fast analysis.

  • PDF

Vertical Z-vibration prediction model of ground building induced by subway operation

  • Zhou, Binghua;Xue, Yiguo;Zhang, Jun;Zhang, Dunfu;Huang, Jian;Qiu, Daohong;Yang, Lin;Zhang, Kai;Cui, Jiuhua
    • Geomechanics and Engineering
    • /
    • v.30 no.3
    • /
    • pp.273-280
    • /
    • 2022
  • A certain amount of random vibration excitation to subway track is caused by subway operation. This excitation is transmitted through track foundation, tunnel, soil medium, and ground building to the ground and ground structure, causing vibration. The vibration affects ground building. In this study, the results of ANSYS numerical simulation was used to establish back-propagation (BP) neural network model. Moreover, a back-propagation neural network model consisting of five input neurons, one hidden layer, 11 hidden-layer neurons, and three output neurons was used to analyze and calculate the vertical Z-vibration level of New Capital's ground buildings of Qingdao Metro phase I Project (Line M3). The Z-vibration level under different working conditions was calculated from monolithic roadbed, steel-spring floating slab roadbed, and rubber-pad floating slab roadbed under the working condition of center point of 0-100 m. The steel-spring floating slab roadbed was used in the New Capital area to monitor the subway operation vibration in this area. Comparing the monitoring and prediction results, it was found that the prediction results have a good linear relationship with lower error. The research results have good reference and guiding significance for predicting vibration caused by subway operation.