• 제목/요약/키워드: slab fracture

검색결과 57건 처리시간 0.029초

폴리머-강섬유를 혼입한 고강도 콘크리트 보의 보수·보강 (Repair and Rehabilitation of Polymer-Steel Fibrous High Strength Concrete Beams)

  • 곽계환;김원태
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제6권2호
    • /
    • pp.135-143
    • /
    • 2002
  • This study is to investigate its use by applying stainless steel wire mash reinforcement method of construction, which is newly developed, on the high strength concrete beam mixed with polymer-steel fiber. In this test, it is investigated and observed such as follows: the ultimate load, the initial flexure crack load, the initial diagonal tension crack load, the relation between load and deflection, load-strain relation, and also crack growth and fracture aspect by increasing load. The results of this test are; first, the stainless steel wire showed some useful reinforcement effects in multiplying the steel's resisting force of moment to the tensile force of beam or slab: second, the promoting strength and internal force was made in the process of the integration at the same reaction by using the penetrating polymer-mortar with an excellent durability and physical property. On the basis of this results, because such instances in applying stainless steel wire Mash reinforcement method of construction have been few so far, through the experimental investigation such as this test over and over again, the efficient and useful method must be developed for the practice.

철판삽입 합성전단벽의 전단강도와 내진거동 (Shear Strength and Seismic Behavior of the Composite Shear Wall with the Steel Plate Embedded in the RC Wall)

  • 천영수;박지영;이종윤
    • 토지주택연구
    • /
    • 제8권3호
    • /
    • pp.211-221
    • /
    • 2017
  • This study proposed hybrid coupled shear wall in the steel plate insertion method, which is capable of reinforcing the shear strength of the entire wall without increasing wall thickness in the wall-slab apartment buildings. The proposed hybrid coupled shear wall was tested for its effectiveness, shear strength and seismic behavior in experiment. As a test result, the shear strength improvement by the proposed hybrid coupled shear was found effective. Integral-type of steel plate insertion was found more effective than separate-type steel plate insertion. In this case, if the stud enforcement method proposed in this study was used, the shear strength of hybrid coupled shear wall was recommended to calculate using the KBC2016 0709.4.1(3) method. The steel plate inserted in the proposed method was found to have no significant impact on the final fracture behavior and bending strength of hybrid coupled shear wall. The shear strength at the final destruction of the wall was merely about 1/50 of the entire design shear strength. Thus, it is deemed that the wall was over excessively designed regarding the shear force in the existing design method. This finding indicates further study on wall designing to ensure effective and economic designing based on appropriate strength estimation under the destruction mechanism.

영구거푸집으로 활용한 FRP 판의 종류에 따른 콘크리트와의 부착응력에 관한 실험적 연구 (An Experimental Study of Bond Stress between Concrete and Various Kinds of FRP Plank used as a Permanent Formwork)

  • 박찬영;유승운
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권3호
    • /
    • pp.92-103
    • /
    • 2015
  • 최근 들어 FRP 판을 영구 거푸집 및 주요 인장보강재로 활용하기 위한 새로운 콘크리트 교량 바닥판 시스템 개발에 대한 연구가 활발히 진행되고 있다. 영구거푸집과 인장 보강재로의 병행이용은 기존의 콘크리트 바닥판 보다 공사비와 공사기간을 절감 할 수 있다. 본연구에서는 영구거푸집 및 주요인장재로 활용한 FRP 판의 종류에 따른 현장타설 콘크리트와 부착응력에 대해 실험을 수행하였다. 부착성능 평가를 실시하였고, 부착특성을 나타내는 중요한 변수중에 하나로서 부착 강도 및 부착면의 파괴 매커니즘 특성을 알 수 있는 계면 파괴에너지를 나타내었다. 일반콘크리트에서 계면 파괴에너지는 GF11의 경우 0.24kN/m이고, GF21의 경우에는 0.43kN/m, GF31과 CF11의 경우에는 각각 0.46kN/m와 0.44kN/m로 나타났고, RFCON에서는 GF12의 경우 0.52kN/m, GF22와 CF12에서는 각각 0.36kN/m와 0.51kN/m로 나타났다.

Carbon fiber sheet 및 carbon fiber strand sheet 접착보강한 RC 상판의 내피로성과 파괴거동과의 상관관계 (Relationship between fatigue resistance and fracture behavior of the carbon fiber sheet and carbon fiber strand sheet reinforced RC slabs)

  • 원찬호;;안태호;김도근
    • 한국결정성장학회지
    • /
    • 제25권6호
    • /
    • pp.294-298
    • /
    • 2015
  • 일본 국토교토성이 책정한 <도로교 장수명화 수선계획사업>에 의하면, 주요 지역에 건설된 RC 상판의 심각한 손상 원인은 대형차량의 주행하중에 의한 피로열화와 재료의 경년열화 등으로 보고되어지고 있다. 따라서 이에 대한 대책으로 탄소섬유 시트를 이용한 하부 접착 보강공법이 많이 소개되어지고 있으나, 최근에는 CFS와 동등한 재료특성치를 보유하며, 시공성이 뛰어난 탄소섬유 스트랜드 시트가 새로운 보강재료로써 관심이 증폭되어지고 있다. 그러나 이러한 CFSS의 윤하중 피로실험을 통한 내피로성 평가는 현재 일부 연구기관에서만 그 성과가 보고되어지고 있는 실정이며, 국내에서는 아직까지 연구성과에 관한 보고 등이 거의 없는 실정이다. 따라서 본 연구에서는 RC 상판의 하부에 CFS를 전면접착 보강한 실험체와 CFSS를 격자형으로 보강한 실험체를 제작하여, 윤하중 피로실험을 실시하고 내피로성을 평가하였다.

Steel Strap으로 횡구속된 무철근 바닥판의 정적 및 피로거동 특성 연구 (A Study on Static and Fatigue Behavior of Restrained Concrete Decks without Rebar by Steel Strap)

  • 조병완;김철환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권5호
    • /
    • pp.137-147
    • /
    • 2012
  • 무철근 교량 바닥판은 콘크리트 내부의 철근을 없애고 거더를 Strap으로 횡구속시켜 Arching action을 극대화시킨 교량 바닥판이다. 본 연구에서는 무철근 바닥판의 균열제어를 목적으로 FRP bar의 배치량을 변수로 하여 내하력과 균열, 연성도, 파괴시 응력수준 등을 판단하여 FRP bar 최소 배치량을 제시하였다. 실험결과 Steel strap 무철근 바닥판은 최소 0.15% FRP 보강근만 배치하여도 내하력과 연성이 확연히 향상됨을 확인하였다. FRP bar를 보강한 무철근 바닥판에 대하여 피로실험을 수행하였으며 200만회 반복하중 재하후 균열, 잔류 처짐 등에서 장기 사용성에 문제가 없음을 확인하였다. 교량 바닥판은 대체로 펀칭전단 파괴를 하며 2방향 슬래브의 전단강도식을 적용할 수 있으나 ACI, AASHTO 등에서는 바닥판의 비선형 파괴형상과 횡구속에 의한 Arching 효과를 명확히 고려하지 못하기 때문에 실제 파괴강도보다 과소평가 한다. 본 연구에서는 Steel strap 바닥판의 실제 파괴형상과 Strap에 의한 횡구속도를 고려한 펀칭전단강도식을 제안하였으며 이는 실험결과와도 비교적 잘 일치하는 결과를 보여주었다.

노후 콘크리트포장 위에 덧씌운 섬유그리드 보강 아스팔트포장의 장기공용성 (Long-term Performance of Fiber Grid Reinforced Asphalt Pavements Overlaid on Old Concrete Pavements)

  • 이주명;백승범;이강훈;김조순;정진훈
    • 한국도로학회논문집
    • /
    • 제19권3호
    • /
    • pp.31-43
    • /
    • 2017
  • PURPOSES : The objective of this study is to verify the effect of fiber grid reinforcement on the long-term performance of asphalt pavement overlaid on old concrete pavement by performing field investigation, laboratory test, and finite element analysis. METHODS : The reflection cracking, roughness, and rutting of fiber grid reinforced overlay sections and ordinary overlay sections were compared. Cores were obtained from both the fiber grid reinforced and ordinary sections to measure bonding shear strength between the asphalt intermediate and asphalt overlay layers. Fracture energy, displacement after yield, shear stiffnesses of the cores were also obtained by analyzing the test results. Finite element analysis was performed using the test results to validate the effect of the fiber grid reinforcement on long-term performance of asphalt pavement overlaid on the old concrete pavement. The fatigue cracking and reflection-cracking were predicted for three cases: 1) fiber grid was not used; 2) glass fiber grid was used; 3) carbon fiber grid was used. RESULTS : The reflection-cracking ratio of fiber grid reinforced sections was much smaller than that of ordinary sections. The fiber grid reinforcement also showed reduction effect on rutting while that on roughness was not clear. The reflection-cracking was not affected by traffic volume but by slab deformation and joint movement caused by temperature variation. The bonding shear strength of the fiber grid reinforced sections was larger than that of the ordinary sections. The fracture energy, displacement after yield, and shear stiffnesses of the cores of the fiber grid reinforced sections were also larger than those of the ordinary sections. Finite element analysis results showed that fatigue cracking of glass or carbon fiber grid reinforced pavement was much smaller than that of ordinary pavement. Carbon fiber grid reinforcement showed larger effect in elongating the fatigue life of the ordinary overlay pavement compared to glass fiber grid reinforcement. The binder type of the overlay layer also affected the fatigue life. The fiber grid reinforcement resisted reflection-cracking and the carbon fiber grid showed the greater effect. CONCLUSIONS :The results of field investigation, laboratory test, and finite element analysis showed that the fiber grid reinforcement had a better effect on improving long-term performance of asphalt pavement overlaid on the old concrete pavement.

철골 모멘트 접합부에서 웨브의 모멘트 전달효율과 변형도 집중과의 관계에 관한 해석적 연구 (Analytical Study on Relationship Between Moment Transfer Efficiency of a Beam Web and Strain Concentration at Steel Moment Connections)

  • 김영주;오상훈;문태섭
    • 한국강구조학회 논문집
    • /
    • 제16권5호통권72호
    • /
    • pp.695-703
    • /
    • 2004
  • 본 논문에서는 4개의 철골 해석모델과 1개의 합성보 해석모델에 대한 단조가력 해석의 결과를 나타냈다. 철골 기둥-보 접합부에서 웨브의 모멘트 전달효율과 변형도 집중에 대해서 조사하였다. 해석결과 각형기둥을 가진 모델의 모멘트 전달효율은 각형기둥 플랜지의 면외변형 때문에 H-기둥을 가진 모델에 비해서 빈약했다. 스캘럽과 얇은 각형기둥 두께 및 슬래브도 또한 모멘트 전달효율의 저하를 가져오는 원인으로서, 이는 보-기둥 접합부의 파단을 초래할 가능성이 크다. 해석 결과는 실험결과와 비교하였다. 실험결과를 기초로 하면, 각형기둥 또는 슬래브가 있는 접합부의 변형능력은 빈약한 모멘트 전달효율과 이에 따른 플랜지의 변형도 집중에 의해 감소했다.

Saw-tooth softening/stiffening - a stable computational procedure for RC structures

  • Rots, Jan G.;Invernizzi, Stefano;Belletti, Beatrice
    • Computers and Concrete
    • /
    • 제3권4호
    • /
    • pp.213-233
    • /
    • 2006
  • Over the past years techniques for non-linear analysis have been enhanced significantly via improved solution procedures, extended finite element techniques and increased robustness of constitutive models. Nevertheless, problems remain, especially for real world structures of softening materials like concrete. The softening gives negative stiffness and risk of bifurcations due to multiple cracks that compete to survive. Incremental-iterative techniques have difficulties in selecting and handling the local peaks and snap-backs. In this contribution, an alternative method is proposed. The softening diagram of negative slope is replaced by a saw-tooth diagram of positive slopes. The incremental-iterative Newton method is replaced by a series of linear analyses using a special scaling technique with subsequent stiffness/strength reduction per critical element. It is shown that this event-by-event strategy is robust and reliable. First, the model is shown to be objective with respect to mesh refinement. Next, the example of a large-scale dog-bone specimen in direct tension is analyzed using an isotropic version of the saw-tooth model. The model is capable of automatically providing the snap-back response. Subsequently, the saw-tooth model is extended to include anisotropy for fixed crack directions to accommodate both tensile cracking and compression strut action for reinforced concrete. Three different reinforced concrete structures are analyzed, a tension-pull specimen, a slender beam and a slab. In all cases, the model naturally provides the local peaks and snap-backs associated with the subsequent development of primary cracks starting from the rebar. The secant saw-tooth stiffness is always positive and the analysis always 'converges'. Bifurcations are prevented due to the scaling technique.

중력전단비에 따른 철근콘크리트 플랫 플레이트 골조의 내진 성능 평가 (Seismic Performance of Reinforced Concrete Flat Plate Frames according to Gravity Shear Ratio)

  • 황보진;한상환;박영미
    • 콘크리트학회논문집
    • /
    • 제22권1호
    • /
    • pp.3-10
    • /
    • 2010
  • 이 연구에서는 중력 전단비에 따른 철근콘크리트 플랫 플레이트 골조의 내진성능을 평가하였다. 이를 위하여, 이 연구에서는 3층, 7층 골조를 중력하중만 고려하여 설계하고, 대상 건물에 대한 비선형 정적 푸쉬 오버 해석과 비선형 동적 해석을 수행하였다. 그리고 이 연구는 그 비선형 해석에서 중력 전단비의 차이에 따른 뚫림 전단과 파괴 메커니즘을 예측할 수 있도록 제안한 슬래브-기둥 접합부 모델을 사용하였다. 이 연구 결과에 따르면 중력 전단비가 골조의 내진성능에 큰 영향을 미치는 것으로 나타났다. 특히 중력 전단비가 커짐에 따라 골조 접합부의 파괴가 취성적인 파괴를 나타내어 내진 성능이 떨어지는 것으로 나타났다.

철근 및 프리스트레스트 콘크리트 슬래브의 비선형 해석 (Nonlinear Analysis of Reinforced and Prestressed Concrete Slabs)

  • 최정호;김운학;신현목
    • 콘크리트학회지
    • /
    • 제8권6호
    • /
    • pp.223-234
    • /
    • 1996
  • 본 논문에서는 단조증가하중을 받는 철근 및 프리스트레스트 콘크리트 슬래브의 비선형거동, 즉 탄성, 비탄성, 극한영역에 이르기까지의 모든 하중이력에 대한 응력-변형도 관계와 균열의 진행 및 철근 및 텐던과 콘트리트의 응력과 변형도 등을 정확히 해석할 수 잇는 해석법의 제시를 목적으로 한다. 이러한 목적을 위하여 본 연구에서는 재료적 및 기하학적 비선형성을 고려하였다. 기하학적 비선형성은 Von Karman의 가정에 기본을 둔 total Lagrangian formulation에 의해 고려하였으며 재료적 비선형성에 대해서는 균열콘크리트에대한 인장, 압축, 전단모델과 콘크리트 중에 있는 철근 및 텐던모델을 조합하여 고려하였다. 이에 대한 콘크리트의 균열모델로서는 분산균열모델을 사용하였으며, 철근 및 텐던에 대해서는 1축 응력상태로 가정하여 등가의 분산분포된 철근 및 텐던층으로 모델화하였다. 본 논문에서 제안한 해석방법의 타당성을 검증하기 위하여 몇 개의 실험치를 해석치와 비교.검토한 결과, 본 논문의 해석방법에 의하면 철근 및 프리스트레스트 콘크리트 슬래브의 비선형거동을 보다 정확하게 예측할 수 있었다.