• Title/Summary/Keyword: skin measurement

Search Result 626, Processing Time 0.047 seconds

Correlation between Subjective and Objective Measurement of Climacteric Women's Hot Flashes (갱년기 여성 안면홍조의 주관적 측정과 객관적 측정의 상관성)

  • Kim, Hyung-Jun;Leem, Kang-Hyun;Kim, Myoung-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.6
    • /
    • pp.765-774
    • /
    • 2010
  • Purpose: The purposes of this study were to explain the phenomena of hot flashes in climacteric women by using Mexameter, Skin Thermometer, Corneometer, and Laser Doppler Perfusion Imager (LDPI) objectively and to identify the interrelation between the subjective and objective measurements of hot flashes by comparing the two as reported in retrospective questionnaires. Methods: The participants were one hundred women (45-60 yr) who were not currently on hormone therapy, and had reached hot flash scores of 10 or higher. Hot flashes were measured in a temperature and humidity controlled room for 7 hr from 10 am to 5 pm. Hot flashes were measured subjectively and recorded via the Hot Flash Diary Report. When participants felt the hot flashes, they were measured objectively by Mexameter, Skin Thermometer, Corneometer, and LDPI. Results: The frequency of hot flashes in participants ranged from 1 to 7 times. When hot flashes occurred in participants, the erythema, skin temperature, skin hydration, and blood perfusion showed statistically significant changes in all measurements. But, the subjective and objective measurements of hot flashes showed only weak correlations. Conclusion: Results indicate a need for future research with subjective and objective measuring instruments chosen depending variations identified for the study.

Analysis of Medium Voltage Power-Line Channel Characteristics Considering the Skin Effect (표피효과를 고려한 중전압 전력선 채널특성 분석)

  • 김선효;이원태;이영철
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.5
    • /
    • pp.731-738
    • /
    • 2002
  • In this paper, we analyzed a medium voltage power line characteristics considering the skin effect for high speed data transmission. Medium power-line characteristics impedance was obtained by the S-parameter method which is used in high frequency band. Power line channel characteristics was measured using it designed coupler, it is a wide band coupler between medium powe-line and measurement system. Attenuation characteristics along the frequency was decreased linearly when skin effect was considered but attenuation characteristics along the frequency was decreased linearly when skin effect was not considered. Impedance was showed lower and lower in proportional to frequency, and variation was decreased in proportional to frequency.

Effect of a New Developed Physical Restraint to Reduce Skin Injury in Intensive Care Units (중환자실에서 피부손상을 감소시키기 위한 억제대 개발 및 적용효과)

  • Mun, Jung-Sook;Lee, Gyeong-Nam;Lee, Dong-Suk
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.18 no.1
    • /
    • pp.28-36
    • /
    • 2011
  • Purpose: The purpose of this study were to develop a new restraint for the intensive care units (ICU) and to investigate the application effect in comparison with a control group using existing restraints. Method: A non-equivalent control group non-synchronized quasi-experimental research design was used. The participants were 40 (control 20, experimental 20) patients who were recruited by convenience sampling the ICU of a university hospital. To avoid contamination of the experiment, data for the control group were collected prior to the experimental group. Measurement variables were edema and skin damage (redness and abrasion) at the application site, and nurses' perceived convenience in applying restraints. Results: Three days after applying the restraint, amount of edema at the application site was small and incidence of skin damage decreased in the experimental group in comparison with the control group. Also, score for application convenience measured by the nurses was higher in for the newly developed restraint than for existing restraints. Conclusion: Results indicate that the newly developed restraint has lower effects such as edema and skin damage and is more convenient compared with existing restraints, and is therefore recommended for patients in the ICU.

Evaluation of the possibility of clinical application by surface dose measurement of ViewRay in MFW treatment (MFW 치료 시 ViewRay의 표면선량 측정에 따른 임상 적용 가능성 평가)

  • Sun, Geo Jun;Son, Sang Jun;Lee, Yang Hoon;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.169-176
    • /
    • 2018
  • Purpose : The purpose of this study is to evaluate clinical applicability of Co-60 ViewRay treatment plan to increase the skin dose in case of high skin dose is required such as Malignant Fungating Wound By measuring the presence / absence of Bolus application and skin dose by the treatment device and comparing it Materials and Methods : Nine inner measuring points of 2.5 cm lattice arrangement and all 13 measuring points including upper and lower left and right measuring points touching the chest and skin were marked. After CT was taken, each treatment plan was formulated through Eclipse and ViewRay-TPS, and a Fixed beam-IMRT treatment plan was formulated so that the left chest V2Gy=95 % is delivered. Before measurement QED detector was calibrated and the QED detector was positioned at the 13 measurement points displayed on Phantom and surface dose of each treatment planner was measured using 5 mm Bolus application using True-beam and View-ray before and after, measure three times and compare each before applying 5 mm Bolus. Results : The surface dose of the Co-60 ViewRay and the linear accelerator appeared at $76.8%{\pm}5.2%$ vs. $67.3{\pm}%7.5%$ and the surface dose after application of 5 mm Bolus was $87.6%{\pm}8.9%$ vs. $80.3%{\pm}10.2%$ It was measured at 10.2 % (p<0.001). Conclusion : As a result of the surface dose measurement of each treatment instrument, Co-60 ViewRay confirmed that the surface dose reached 95.6 % of 6 MV Linac with conventional 5 mm bolus, despite not using Bolus (p<0.001). Also, by utilizing magnetic resonance images for each treatment, it is possible to observe the change in the treatment site without the problem of exposure, it is easy to formulate an adaptive treatment plan and it is easy to secure the skin dose, so the size In the case of Malignant Fungating Wound patients who need fast skin changes and need high skin doses, Co-60 ViewRay is considered to be more useful than linear accelerators.

  • PDF

Measurement of Surface Strain on Soft Biological Tissues Using Irregular Grid Pattern (불규칙적인 격자망을 이용한 생체 연조직의 곡면변형률 측정)

  • Lee, Jun Sik;Kim, Ki Hong;Kim, Hyung Jong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.8
    • /
    • pp.1051-1057
    • /
    • 2013
  • In this study, an automatic surface-strain measurement system called "ASIAS-bio" has been developed. This system can be used even in cases in which it is very difficult to apply a regular grid pattern necessary for measuring surface-strain, such as curved or uneven surfaces; surfaces damaged by corrosion or contamination; or soft materials such as rubber, foam, and biological tissues. This system works independently of the measurement conditions including the material and its surface condition, grid pattern and size, grid marking method, and degree of deformation. A comparison between the strain distributions of the sheet metal parts measured by using this system and those obtained by a commercial system showed that this system was sufficiently reliable. In addition, the deformation of the swine joint capsule and human knee skin was measured by using this system to demonstrate its usefulness.

Development of Pressure Sensor on Polymer Substrate for Real-time Pulse and Blood Pressure Measurements (실시간 맥박 및 혈압 측정을 위한 폴리머 기판 압력센서 개발)

  • Kim, Jin-Tae;Kim, Sung Il;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.9
    • /
    • pp.669-676
    • /
    • 2013
  • In this study, we introduce a polymer(polyimide) based pressure sensor to measure real-time heart beat and blood pressure. The sensor have been designed with consideration of skin compatibility of material, cost effectiveness, manufacturability and wireless detection. The designed sensor was composed of inductor coils and an air-gap capacitor which generate self-resonant frequency when electrical source is applied on the system. The sensor was obtained with metalization, etching, photolithography, polymer adhesive bonding and laser cutting. The fabricated sensor was shaped in circular type with 10mm diameter and 0.45 mm thickness to fit radial artery. Resonant frequencies of the fabricated sensors were in the range of 91~96 MHz on 760 mmHg pressurized environment. Also the sensor has good linearity without any pressure-frequency hysteresis. Sensitivity of the sensor was 145.5 kHz/mmHg and accuracy was less than 2 mmHg. Real-time heart beat measurement was executed with a developed hand-held measurement system. Possibility of real-time blood pressure measurement was showed with simulated artery system. After installation of the sensor on skin above radial artery, simple real blood pressure measurement was performed with 64 mmHg blood pressure variation.

A Study on the Measurement of Impedance in Animal Tissue Using Gold Electrodes (금 전극을 이용한 동물 조직 내 임피던스 측정연구)

  • Kim, Min Soo;Cho, Young Chang
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.445-450
    • /
    • 2021
  • Bio-impedance measurement is a measurement device that can be used to obtain biometric information and diagnose skin diseases using convenience, low cost, and low cost devices. In this study, the bio-impedance was measured using a direct dry gold electrode and a simulation study through animal bio modeling to obtain biometric information in a biometric form. Impedance was measured by inserting electrodes into subcutaneous areas of animal tissue and applying frequencies of 100 uA, 1-100 kHz using a two-electrode method. As a result of the measurement, the resistance of the electrodes is measured high at 5 mm electrodes compared to 7.5 mm and 10 mm electrodes based on 5 mm electrodes. Based on the 5 mm electrode, an average difference of 1.49% was found for the 7.5 mm electrode in the total frequency range, and the impedance difference was confirmed to be 2.624% for the 10 mm electrode. In the future, the research results are expected to be valuable in designing and manufacturing electrodes for bio-inserted electrocardiogram sensors.

A New Method For Measuring Acupoint Pigmentation After Cupping Using Cross Polarization (교차편광 촬영술(Cross Polarization Photographic Technique)를 이용한 부항요법의 배수혈 피부 색소 침착 변화 측정 평가)

  • Kim, Soo-Byeong;Jung, Byungjo;Shin, Tae-Min;Lee, Yong-Heum
    • Korean Journal of Acupuncture
    • /
    • v.30 no.4
    • /
    • pp.252-263
    • /
    • 2013
  • Objectives : Skin color deformation by cupping has been widely used as a diagnostic parameter in Traditional Korean Medicine(TKM). Skin color deformation such as ecchymoses and purpura is induced by local vacuum in a suction cup. Since existing studies have relied on a visual diagnostic method, there is a need to use the quantitative measurement method. Methods : We conducted an analysis of cross-polarization photographic images to assess the changes in skin color deformation. The skin color variation was analyzed using $L^*a^*b^*$ space and the skin erythema index(E.I.). The meridian theory in TKM indicates that the condition of primary internal organs is closely related to the skin color deformation at special acupoints. Before conducting these studies, it is necessary to evaluate whether or not skin color deformation is influenced by muscle condition. Hence, we applied cupping at BL13, BL15, BL18, BL20 and BL23 at Bladder Meridian(BL) and measured blood lactate at every acupoint. Results : We confirmed the high system measurement accuracy, and observed the diverse skin color deformations. Moreover, we confirmed that the $L^*$, $a^*$ and E.I. had not changed after 40 minutes(p>0.05). The distribution of blood lactate levels at each part was observed differently. Blood lactate level and skin color deformation at each part was independent of each other. Conclusions : The negative pressure produced by the suction cup induces a reduction in the volumetric fraction of melanosomes and subsequent reduction in epidermal thickness. The relationship between variations of tissue and skin properties and skin color deformation degree must be investigated prior to considering the relationship between internal organ dysfunction and skin color deformation.