• Title/Summary/Keyword: skin absorption

Search Result 327, Processing Time 0.033 seconds

Strength Analysis of Double Bottom Structures in Stranding by Idealized Structural Unit Method (이상화(理想化) 구조요소법(構造要素法)에 의한 좌초시(坐礁時) 이중저(二重底) 구조(構造)의 손상 및 강도(强度) 해석(解析))

  • Jeom-K. Paik;Chang-Y. Kim
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.28 no.1
    • /
    • pp.125-138
    • /
    • 1991
  • In this paper, an efficient method for the analysis of damage and strength of double bottom structure in stranding is described by using idealized structural unit method. Also a procedure for the determination of the effective double bottom height which is required in order to protect the inner-bottom plate is proposed. In the comparison between the present solution and he existing experimental and numerical results in stranding, its observed that the present method gives reasonable results requiring very shorts computiong times. The present method is then applied to the double bottom structure of 40K product oil carrier which is designed by the double skin design concept as an example. By performing the series of analysis, the influence of vertical member space, plate thickness and double bottom height on the energy absorption capacity of the double bottom structure in stranding is investigated. Also the minimum double bottom height with varying each design variable Is calculated based on the above result.

  • PDF

Computation of Absorbed Power adiated from a Portable Phone Using FDTD (FDTD 방법을 이용한 휴대폰 전파의 인체 흡수전력량 산출)

  • 김채영;이승학;정백호
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.491-498
    • /
    • 1998
  • Based on FDTD(Finite-Difference Time-Domain) method the human head absorbed power radiated from a 1.8 GHz portable phone is computed. For this computation the 7 layered media for the human head modeling and the monopole antenna attached to metallic box for the portable phone are used. To reflect the real circumstances typical sizes of human heads and portable phones are considered in the calculation. The length of monopole antenna is 4.5 cm. Under the predetermined model the distribution of SAR over the human head are calculated, and from which the place of maximum SAR is near the head skin surface, not deep places far into the head. The computation shows the maximum SAR to be 1.4 mWg somewhat less than the internationally adopted value of 1.6 mW/g.

  • PDF

Polyoxyethylene Tocopheryl Ethers; A Series of Novel Surfactants from Tocopherol for Functional Cosmetics (토코페롤에서 유도된 기능성 화장품용의 새로운 계면 활성제)

  • 김영대;김창규
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.18 no.1
    • /
    • pp.1-41
    • /
    • 1992
  • A new and unique class of nonionic surfactants was synthesized by reacting biological a-tocopherol with ethylene oxide for functional cosmetics. The structures were confirmed by Hl-UMR, FT-lR, TLC and elemental analysis. POV and conjugated diene value study for EPO showed POE(n)TE had antioxidative effect similar to tocopheryl acetate Protective effect on cell membrane in photohemolysis of POE(5)TE, POE(10)TE and POE(18)TE were slightly lower than tocopherol but higher than nonoxynol-12, and POE(10)TE had UV absorption power comparable with tocopherol and homosalate. Biological activity of the hydrophobic group of the new surfactants make them unique and different from those of conventional nonionic surfactants Systematic safety evaluations of POE(n)TEs on the skin and eye proved that they are as safe as tocopherol. The results of physicochemical study showed POE(10)TE had the lowest CMC value, POE(18)TE had the maximum surface tension reduction and the highest foam volume and POE(n)TEs had various HLB values by the degree of ethoxylation. The test resul Is of technological and practical applications of these surfactants for cosmetics showed some POE(n)TEs were superior to conventional surfactants. POE(5)TE in W/O emulsions, POE(10)TE and POE(12)TE in O/W emulsions, POE(12)TE in dispersions, POE(18)TE in solubilizations and POE(50)TE in gelations were shown to be excellent which was considered due to the structural characteristic and formation of liquid crystals of POE(n)TEs. By the development and applications of these excel lent multi-functional surfactants, innovative functional cosmetics were successfully formulated.

  • PDF

Human Exposure and Health Effects of Inorganic and Elemental Mercury

  • Park, Jung-Duck;Zheng, Wei
    • Journal of Preventive Medicine and Public Health
    • /
    • v.45 no.6
    • /
    • pp.344-352
    • /
    • 2012
  • Mercury is a toxic and non-essential metal in the human body. Mercury is ubiquitously distributed in the environment, present in natural products, and exists extensively in items encountered in daily life. There are three forms of mercury, i.e., elemental (or metallic) mercury, inorganic mercury compounds, and organic mercury compounds. This review examines the toxicity of elemental mercury and inorganic mercury compounds. Inorganic mercury compounds are water soluble with a bioavailability of 7% to 15% after ingestion; they are also irritants and cause gastrointestinal symptoms. Upon entering the body, inorganic mercury compounds are accumulated mainly in the kidneys and produce kidney damage. In contrast, human exposure to elemental mercury is mainly by inhalation, followed by rapid absorption and distribution in all major organs. Elemental mercury from ingestion is poorly absorbed with a bioavailability of less than 0.01%. The primary target organs of elemental mercury are the brain and kidney. Elemental mercury is lipid soluble and can cross the blood-brain barrier, while inorganic mercury compounds are not lipid soluble, rendering them unable to cross the blood-brain barrier. Elemental mercury may also enter the brain from the nasal cavity through the olfactory pathway. The blood mercury is a useful biomarker after short-term and high-level exposure, whereas the urine mercury is the ideal biomarker for long-term exposure to both elemental and inorganic mercury, and also as a good indicator of body burden. This review discusses the common sources of mercury exposure, skin lightening products containing mercury and mercury release from dental amalgam filling, two issues that happen in daily life, bear significant public health importance, and yet undergo extensive debate on their safety.

Clinical evaluation of the body fat breakdown effect during topical seaweed extracts treatment and in combination with the iontophoresis and phonophoresis(II) (이온삼투요법과 음파영동이 해조류 추출물의 체지방 분해에 미치는 효과 검정(II))

  • Suh Tae Soo;Park Jong Suk;Kim You Young;Lee Dong Ho
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.1
    • /
    • pp.70-84
    • /
    • 2004
  • This study was carried out to evaluate the body fat breakdown during topical seaweed extract treatment and in combination with the iontophoresis, phonophoresis method to enhance skin absorption of lipolytic compounds. Of 24 female obesity subjects, 7 treated a gel types of seaweed extract only(control group) and 10 treated in combination with the iontophoresis(experimental group I) and 7 treated in combination with the phonophoresis(experimental group II). Topical treatment of each sample was designed for 2 weeks, treated with 2 times a day about $10m{\ell}$ on the abdomen, triceps, thigh and superior ilium, respectively. Experimental group treat with the iontophoresis and phonophoresis during 5 minutes immediately after topical treatment. After one and two weeks of topical treatment, measured body weight, body fat, skinfolds thickness respectively. Then venous blood samples were taken and analyzed serum lipids. The results were as follows; 1) There were decrement of body weight, $\%$ of body fat, superior ilium, triceps and thigh thickness between pre and post treatment in all group. Especially, there were more decrement of body weight, $\%$ of body fat in the iontophoresis treated group. 2) There were decrement in total CHOL, LDL, TRIG and increment in HDL in all group. These phenomena were predominant in the iontophoresis treated group. CHOL decrement in the experimental group were significant after two weeks iontophoresis treatment.

  • PDF

Risk Assessment of Ethylhexyl Dimethyl PABA in Cosmetics

  • Sung, Chi Rim;Kim, Kyu-Bong;Lee, Joo Young;Lee, Byung-Mu;Kwack, Seung Jun
    • Toxicological Research
    • /
    • v.35 no.2
    • /
    • pp.131-136
    • /
    • 2019
  • Ethylhexyl dimethyl para-aminobenzoic acid (PABA) is an oily yellow liquid derivative of water-soluble PABA commonly used in sunscreen. Ethylhexyl dimethyl PABA is widely used as an ingredient in many cosmetics at an average concentration of 1.25% (0.5-2.0%) in Korea. Previous studies, including those involving animals, have demonstrated that ethylhexyl dimethyl PABA is toxic to the following four organs: testis, epididymis, spleen, and liver. In addition, experiments using human keratinocytes found that ethylhexyl dimethyl PABA inhibits cell growth and DNA synthesis at low concentrations, and halted the cell cycle of MM96L cells (human melanoma cell line) at the G1 phase. Despite limited clinical data in humans, many studies have confirmed increased mutagenicity of ethylhexyl dimethyl PABA following exposure to sunlight, which suggests that this molecule is likely to contribute to onset of sun-induced cancer despite protecting the skin through absorption of UVB. For risk assessment, the no observed adverse effect level (NOAEL) chosen was 100 mg/kg bw/day in a 4 weeks oral toxicity study. Systemic exposure dosage (SED) was 0.588 mg/kg bw/day for maximum use of ethylhexyl dimethyl PABA in cosmetics. Based on the risk assessment and exposure scenarios conducted in this study, the margin of safety (MOS) was calculated to be 180.18 for a sunscreen containing 8% ethylhexyl dimethyl PABA, which is the maximum level allowed by the relevant domestic authorities.

Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector

  • Lee, Kyeong Hee;Kim, Myeong Seong;Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1377-1384
    • /
    • 2018
  • Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of $0.008226cm^2/g$, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was $2.699g/cm^3$. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of $75.33{\mu}Gy$ and a depth dose of $71.77{\mu}Gy$, those with regard to the OSL were surface dose of $9.2{\mu}Gy$ a depth dose of $70.39{\mu}Gy$ and a mean dose of $74.79{\mu}Gy$. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were $0.742{\mu}Sv$, $8.9{\mu}Sv$, $2.96{\mu}Sv$ and those for the OSL were $0.754{\mu}Sv$, $9.05{\mu}Sv$, and $3.018{\mu}Sv$ in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.

A Study on the Failure Modes of Neat Kevlar Fabric and Kevlar Liquid Armor Impregnated with Shear Thickening Fluid (케블라 직물과 전단농화유체로 함침된 케블라 액체 방탄재의 파단모드 연구)

  • Yoon, Byung-Il;Song, Heung-Sub;Paik, Jong-Gyu
    • Composites Research
    • /
    • v.20 no.3
    • /
    • pp.17-24
    • /
    • 2007
  • In this study, the failure modes by ballistic impacts were studied both for a neat Kevlar woven fabric and a Kevlar liquid armor impregnated with shear thickening fluid (STF) containing silica particles. These two materials showed quite different failure modes macroscopically in ballistic impacts tests used by Cal.22 FSP and 9mm FMJ bullet. Yarn pull-out for the neat Kevlar woven fabric and yarn fracture occurred partially through all plies from 1st ply to last one for the STF-Kevlar are an important energy absorption mechanisms. The results observed by S.E.M showed commonly fiber damage which are torn skin in the longitudinal fiber direction, fiber split axially and fiber fracture for two materials. The reasons why STF-kevlar liquid armor material exhibits excellent ballistic performance are as follow: firstly the increased friction forces between yarn-yarn and fabric-fabric covered with silica particles and secondary the evolution of shear thickening phenomenmon resulting in suppression of yarn mobility.

Effect of Dietary Calcium, Casein, and Suet on the Accumulation of Cadmium in Mice (생쥐에 있어서 카세인, 칼슘 및 우지가 카드뮴의 조직내 축적에 미치는 영향)

  • Jung, Kyu-Sang;Kim, Doo-Hie;Jung, Kyung-Dong
    • Journal of Preventive Medicine and Public Health
    • /
    • v.21 no.2 s.24
    • /
    • pp.340-350
    • /
    • 1988
  • This study was carried out to clarify the effect of dietary calcium, casein, and suet on the accumulation of cadmium in mice. It was performed for 30 days, from April 11 to May 10 1988.90 mice were divided into 4 experimental groups and control group with 6 mice each dietary group, and measured survival rate, body weight, and weight ratio of organ to body. The contents of cadmium in liver, kidney, spleen, muscle and skin with hair, and feces were analyzed by atomic absorption spectrophotometer after sacrifice by anesthesia. After 30 days, the survival rate of control group was loot,, but 66.7% in group IV(basal diet+Cd+Ca) with single dose of $100{\mu}g$ cadmium and with free-intake of water containing 50ppm cadmium, and group V(basal diet+Cd+suet) with free-intake of water containing 50ppm cadmium. The rate of weight gain in the case of single dose of $100{\mu}g$ cadmium was highest in group IV as 42.3% and lowest in group V as 26.0%, whereas in the cases of free intake group W was highest as 24.0% and group II(basal diet+Cd) was lowest as 11.6%. The body weight, in the case of single dose of $100{\mu}g$ cadmium showed no increase until 5th day after acute poisoning. But in the case of free intake group, it showed very slight increase through all the breeding period. The weight ratio of organ to body were lowest in the liver of group II in both occasions. The most of cadmium adminstered. were excreted through feces within 2 days after single dose of $100{\mu}g$ cadmium. The contents of cadmium in each group were significantly higher than those of control group. In the liver, kidney, spleen and muscle, group II showed the highest level in both occasions of $100{\mu}g$ single dose and free intake of water containing 50ppm cadmium. In the skin with hair, group ll of the occasion with single dose of $100{\mu}g$ and group V with free intake showed the highest level. And the contents of cadmium in tissue were markedly higher in the occasion of free intake of water containing 50ppm cadmium. From the above results I would conclude that the addition of casein and calcium are effective in the inhibition of intesitnal absorption of cadmium esp. by calcium.

  • PDF

Calculation of the Electromagnetic Fields Distribution around the Human Body and Study of Transmission Loss Related with the Human Body Communication (인체 통신에 따른 인체 주변에서의 전기장 분포 계산 및 전송 손실 연구)

  • Ju, Young-Jun;Gimm, Youn-Myoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.2
    • /
    • pp.251-257
    • /
    • 2012
  • Human body communication means transmitting and receiving data through human body medium or through free space along with the human body skin. Electric field distribution around the human body between the transmitter and the receiver were calculated at five different frequencies with 5 MHz interval between 10 MHz and 30 MHz. Commercial electromagnetic simulation tool was used for the calculation of E-field distributions applying the Korean standard male model including 29 different kinds of human tissues. After calculating specific absorption rate(SAR) values on back of the hand, it was compared with International Commission on Non-Ionizing Radiation Protection(ICNIRP) human protection guideline. While conductivities(${\sigma}$) and relative permittivities(${\varepsilon}_r$) of the human tissues for each frequency were input as the analyzing parameters, electric field intensities near both hands were integrated along the integral line between the nearby electrodes for the calculation of the transmitting and receiving voltages whose ratio was defined as channel loss. The calculated channel losses were about ($75{\pm}1$) dB and showed nearly flat response all through the evaluated frequencies.