• Title/Summary/Keyword: size distribution

Search Result 7,728, Processing Time 0.035 seconds

Fragmentation Fractal Analysis on Particle-size Distribution (Fragmentation 프랙탈을 이용한 입도분포 분석)

  • 민덕기;이완진
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.199-206
    • /
    • 2003
  • Particle-size distribution in soils is one of the most fundamental physical properties of soils. One of the latest developments in the study of particle-size distributions has focused on the use of fractal theories. In this study, the fragmentation fractals were used for determining the characteristics of the particle-size distribution curve. It was shown that the mass-size distribution method was more practical than the cumulative number-size distribution method. From the co-relation between fractal dimensions($D_{tot}$) and the coefficient of uniformity($C_{u}$), there was a sharp increase in fractal dimensions for $C_{u}$<4, but fractal dimension converged the single value for $D_{u}$$\geq$6. Fractal dimensions were affected by small sized particles for $C_{c}$$\geq$3 and large sized particles for $C_{c}$/<3. As a result of the analysis of the influence of the effective size($D_{10}$), it was observed that the changes of $D_{tot}$/ were nominal beyond the effective size.

Characterization of Chemical Composition and Size Distribution of Atmospheric Aerosols by Low-Pressure Impactor (저압 임팩터를 이용한 대기 에어로졸 입자의 입경분포 측정과 화학조성 자료의 해석)

  • 박정호;최금찬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.13 no.6
    • /
    • pp.475-486
    • /
    • 1997
  • The characteristics of atmospheric aerosols were investigated as a function of particle size and water solubility. The atmospheric aerosols were sampled with classifying into 12 size ranges by the use of Andersen low-pressure impactor. Collected aerosol particles were extracted by ultrapure water and filtered to be separated into water-soluble and insoluble components. The concentrations 12 elements in both components were determined by PIXE analysis. And the concentrations of 8 ions in the soluble component were analyzed by ion chromatography. In general, the mass size distribution of particulate matter was represented as a bimodal distribution. The mass size distributions of S$(SO_4^{2-}), K(K^+), Zn and NH_4^+$ skewed to the smaller size range and those of Si, Ca$(Ca^{2+}), Fe, Na^+ and Mg^{2+}$ skewed to the larger size range. They had roughly one peak in the fine and coarse particle region,respectively. On the other hand, the mass size distribution of Ti, Mn, Ni, Cu, $Cl^- and NO_3^-$ were represented as the bimodal distribution. Fe and Si in the aerosol particles extracted into pure water are existing in high insoluble state. Conversely, almost the whole of S is dissolved in water.

  • PDF

An Analysis of Hand Measurements for Designing Size Specification for Children's Gloves (아동용 장갑의 치수 규격 설계를 위한 손 치수 분석)

  • Jeon, Eunkyung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.6
    • /
    • pp.923-934
    • /
    • 2021
  • Most apparel products have national standards for sizing; however, for gloves, national sizing standards have not yet been established. This study aims to analyze children's hand dimensions and propose a size specification for children's gloves that shows children's hand-related size information. Among the 3D measurements of sixth Size Korea Project, the measurement data of 19 dimensions related to the hands of 1,057 boys and girls aged 7-13 years old were analyzed. The distribution and growth trend of hand measurements for boys and girls demonstrated considerable mean differences and distribution trends by gender and age as per hand dimensions, which leads to the conclusion that it is necessary to show these results in the children's glove design. Based on these results, the cross-distribution maps of children's hand length and hand circumference were drafted; furthermore, the distribution relationship with an adult hand size was identified. Based on the distribution of hand sizes, the distribution of adult hand sizes overlapped with children's hand sizes was verified, and children's glove size specifications were presented. The results can be used as useful data such as measures for setting the size range and sizing system for children's gloves.

The Economic Design of the Multi-stage Distribution System Using Different Supplier according to Order Size (주문크기에 따라 다른 공급처를 이용하는 다단계 물류시스템의 경제적 설계)

  • 장석화
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.26 no.1
    • /
    • pp.85-94
    • /
    • 2003
  • In this paper, a mathematical model is developed for economic design of multi-stage distribution system that consists of factory, central distribution centers, local distribution centers and retailers. The retailers are supplied products from different stage suppliers according to order size. The retailers are supplied products from factory if demand amount is large, central distribution center if medium, local distribution center if small. The economic design is to determine the economic size of facility factors that consist of distribution system. The cost factors are transportation cost from supply places to demand places, handling cost at distribution centers and inventory holding cost at retailers. It is to determine the transportation route of each retailer, the size and number of the vehicle at factory and distribution centers, the handling amount at distribution centers in order to minimize the total costs. The mathematical model is represented, the solution procedure is developed, and a numerical example is shown.

A Study on the Prediction of the Drop Size Distribution of Pressure-Swirl Atomizer (압력식 스월 노즐의 액적 크기분포 예측에 관한 연구)

  • Cho, D.J.;Yoon, S.J.;Kim, D.W.
    • Journal of ILASS-Korea
    • /
    • v.1 no.1
    • /
    • pp.44-54
    • /
    • 1996
  • A theoretical and experimental study was carried out on the prediction of drop size distribution of the pressure swirl atomizer. Drop size distribution was obtained by using maximum entropy formal ism. Several constraints in the form of the definition of mean diameter were used in this formulation in order to avoid the difficulties of the estimating source terms. In this study $D_{10}$ was only introduced into the formulation as a constraint. A drop size obtained by using linear Kelvin-Helmholtz instability theory was considered as an unknown characteristic length scale. As a result, the calculated drop size was agreed well with measured mean diameter, particularly with $D_{32}$. The predicted drop size distribution was agreed welt with experimental data measured wi th Malvern 2600.

  • PDF

Analysis of Sodium Spray Fire Using Gaussian Droplet Size Distribution (Gaussian 액적 크기 분포 함수를 이용한 분무형 화재 현상 해석)

  • Kim, B.H.;Hahn, D.H.;Suh, S.H.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.1
    • /
    • pp.72-81
    • /
    • 2004
  • Study on the analysis of sodium spray fire using Gaussian drop size distribution, which redistributes a droplet spectrum with given mean diameter if its size classes with critical diameter(D>8mm) occur, was carried out. In this case, the oversized droplets were reduced to a stable diameter. Results calculated by the code using Gaussian drop size distribution were in better agreement with AI experimental results than those of NACOM and SPRAY code. The effect of variance on pressure in the test cell appeared greatly by introducing Gaussian function, which could represent various sodium droplet size distribution. The increase of the variance with mean droplet size resulted had an important effect upon the pressure in the test cell.

Effective Construction Method of Defect Size Distribution Using AOI Data: Application for Semiconductor and LCD Manufacturing (AOI 데이터를 이용한 효과적인 Defect Size Distribution 구축방법: 반도체와 LCD생산 응용)

  • Ha, Chung-Hun
    • IE interfaces
    • /
    • v.21 no.2
    • /
    • pp.151-160
    • /
    • 2008
  • Defect size distribution is a probability density function for the defects that occur on wafers or glasses during semiconductor/LCD fabrication. It is one of the most important information to estimate manufacturing yield using well-known statistical estimation methods. The defects are detected by automatic optical inspection (AOI) facilities. However, the data that is provided from AOI is not accurate due to resolution of AOI and its defect detection mechanism. It causes distortion of defect size distribution and results in wrong estimation of the manufacturing yield. In this paper, I suggest a size conversion method and a maximum likelihood estimator to overcome the vague defect size information of AOI. The methods are verified by the Monte Carlo simulation that is constructed as similar as real situation.

A Survey of Particulate Size Distribution in Work Environment (일부 분진 작업장에서의 공기중 분진 입경분포)

  • 김영식;이병인;홍성철
    • Journal of Environmental Health Sciences
    • /
    • v.17 no.2
    • /
    • pp.22-26
    • /
    • 1991
  • Authors investigated the particulate size distribution in work environment of Banwol and Changwon industrial complex. Size distributions of particles exposured to workers in welding and in grinding process were evaluated by ambient cascade impactors. Respirable matter fractions were calculated from the size distribution data by the respirable particle mass of the ACGIH criteria.

  • PDF

The Droplet Size Distribution of Fan Spray at Different Surrounding Conditions (팬형분무의 주변조건에 따른 입자분포 변화)

  • Moon, Seok-Su;Choi, Jae-Joon;Bae, Choong-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.7 s.262
    • /
    • pp.611-619
    • /
    • 2007
  • In this study, the droplet size distribution of a slit injector at different surrounding conditions, such as air flow and fuel temperature, were investigated. Phase Doppler anemometry (PDA) was utilized to investigate the initial droplet size distribution and the effect of fuel temperature and air flow on droplet size distribution. The entrained air motion was also evaluated by the temporal velocity profile of droplets. When the air flow velocity increased, the small droplets were more entrained to the upper and central parts of the spray and this tendency was confirmed by plotting the temporal velocity profile of droplets. This entrainment of small droplets at high airflow velocities caused relatively small mean droplet size at upper and central parts of the spray and the large mean droplet size at downstream and edge of the spray, compared to that of low airflow velocities. The total mean droplet size, obtained by averaging the size of all droplets measured at all test locations, decreased when the high airflow velocities were applied. The increased fuel temperature, with an airflow velocity of 10m/s, caused reduced droplet size at all test locations. However, the decreased value of mean droplet size at high fuel temperatures was relatively higher at upper parts of the spray, compared to downstream, as a result of enhanced entrainment of small droplets to upper parts of the spray.

Coal particle distribution inside fuel droplets of high loading CWM (고부하도 CWM 연료방울안에 존재하는 미분탄 분포)

  • 김성준;유영길
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.618-629
    • /
    • 1991
  • The purpose of this experiment is to understand the distribution of coal particles inside CWM droplet which is believed to be a very important factor controlling the flame stability. CWM slurry is atomized by an air assisted twin fluid nozzle. An experimental rig is designed and fabricated. The mean size of coal particle distribution in CWM slurry, atomizing air pressure, coal particle loading in slurry and sampling position inside spray are main experimental variables. The atomized CWM droplets are sampled on the thin white layer of magnesium oxide by the emergency sampling shutter. The sampled coal particles on magnesium oxide layers are collected into test tubes and dispersed completely by Ultra-Sonicator. The size distribution of coal particles inside droplets are measured by Coulter Counter. The presence of coal particle inside the impressions of droplets on magnesium oxide layer are investigated by photo technique. There are quite many droplets which do not have any coal particles. Those are just water droplets, not CWM droplets. The population ratio of droplets without coal particles to toal number of droplets is strongly affected by the mean size of coal particle distribution in slurry and this ration becomes bigger number as the mean size of coal particles be larger. The size distribution of coal particles inside CWM droplets is not even and depends on the size of droplet. Experimental results show that the larger CWM droplets has droplets has bigger mean value of particle size distribution. This trend becomes more evident as the atomizing air pressure is raised and the mean size of coal particles in CWM slurry is bigger. That is, the distribution of coal particles inside CWM dropolets is very much affected by the atomizing air pressure and the mean size of pulverized coal particles in CWM slurry.