Study on Building a Structural Health Monitoring System for Uldolmok Tidal Current Power Plant (울돌목 시험조류발전소 구조물 안전감시시스템 구축에 관한 연구)

  • Yi, Jin-Hak;Park, Woo-Sun;Park, Jin-Soon;Lee, Kwang-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.635-638
    • /
    • 2007
  • In this paper, we described the fundamental concepts of proposed structural health monitoring system for Uldolmok Tidal Current Power Plant focusing on the use of smart sensors including fiber bragg grating sensors and macro fiber composite sensors. The structural health monitoring system can play an important role to maintain the structural safety for offshore structures like as bridges and high-rise buildings. In the case of tidal current power plant, the monitoring system is much more important since the structures are usually constructed at the site with severer environmental loadings such as high current speed.

  • PDF

Wireless Sensors Module for Remote Room Environment Monitoring

  • Lee, Dae-Seok;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.449-452
    • /
    • 2005
  • For home networking system with a function of air quality monitoring, a wireless sensor module with several air quality monitoring sensors was developed for indoor environment monitoring system in home networking. The module has various enlargements for various kinds of sensors such as humidity sensor, temperature sensor, CO2 sensor, flying dust sensor, and etc. The developed wireless module is very convenient to be installed on the wall of a room or office, and the sensors in the module can be easily replaced due to well designed module structure and RF connection method. To reduce the system cost, only one RF transmission block was used for sensors' signal transmission to 8051 microcontroller board in time sharing method. In this home networking system, various indoor environmental parameters could be monitored in real time from RF wireless sensor module. Indoor vision was transferred to client PC or PDA from surveillance camera installed indoor or desired site. Web server using Oracle DB was used for saving the visions by web-camera and various data from wireless sensor module.

  • PDF

Monitoring of Early-age Behavior of Concrete Retaining Wall by FBG Sensors (FBG센서를 이용한 콘크리트옹벽 초기재령 특성 모니터링 연구)

  • Jang, Il-Young;Yun, Ying-Wei;Kim, Young-Gune
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.89-90
    • /
    • 2009
  • FBG temperature sensor and strain sensor has been used to monitoring shrinkage and temperature of concrete retaining wall in construction site in its casting early age. The test results indicate that this monitoring method is a practical method for monitoring concrete at very early age. The monitoring technique used in this research could be extended to monitor shrinkage and temperature for mass concrete structure.

  • PDF

Development of In-Situ Soil Gas Monitoring Well for Managing the Bioventing Performance (생물학적 통풍법 공정관리를 위한 원위치 토양가스 관측정 개발)

  • Yu, Chan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.1
    • /
    • pp.67-76
    • /
    • 2007
  • Bioventing is commonly used for petroleum hydrocarbon (PHC) spills. This process provides better subsurface oxygenation, thus stimulating degradation by indigenous microorganisms. Therefore soil vapor monitoring points (VMPs) are extremely important in determining the potential effectiveness of bioventing and in long-term monitoring of bioventing progress. In this study in-situ soil gas monitoring well (GMW) was developed and presented the pilot test results which recover the contaminated site by bioventing method. The result of application was successful and it was expected that GMW developed could be applied to the evaluation procedure of bioventing effectiveness and long-term remediation potential.

Productivity Analysis of the Site Installation Stage of Laminated Modular Multi-Family Housing (적층식 모듈러 공동주택 현장설치 단계의 생산성 분석)

  • Park, Moon-Sun;Kim, Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.5
    • /
    • pp.519-527
    • /
    • 2019
  • This study was conducted to present useful information on the utilization and productivity analysis of laminated modular multi-family housing. To this end, the process of site installation was investigated and analyzed through a prior study, and the monitoring survey was conducted through the site installation case of an stacked multi-family housing. Based on the above, the results of productivity analysis using the web-cyclone technique were also presented. However, the site installation process has limitations on generalisation because the process is not the same for each construction company, and also limits that require verification through application in the actual site of the web-cyclone model presented in this study.

On-Line System for Partial Monitoring Discharge (온라인 부분방전 감시 시스템)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2114-2115
    • /
    • 2008
  • We consider the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers is described.

  • PDF

Noise Test and Evaluation of a 750 kW Wind Turbine Generator (750 kW 풍력발전기의 소음 실증)

  • Kim, Seock-Hyun;Kim, Tae-Hyung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.2 s.107
    • /
    • pp.124-131
    • /
    • 2006
  • This study introduces an environmental noise evaluation procedure for wind turbines(W/T) and the evaluation result of a 750 kW wind turbine(W/T) system. Test and evaluation are performed according to the international standard IEC 61400-11 on J48 W/T which is under operation in Daekwanryung W/T test site. With the meteorological data and W/T operational data, noise data are monitored and analysed. An integrated monitoring system is constructed in the test site and is utilized for the evaluation. From the measured noise data, acoustic power level, directivity and tonality of the W/T are estimated under the wind speeds required fly the International standard. The purpose of the study is to establish an W/T noise evaluating system satisfying the international standard and to obtain noise data for home made 750 kW W/T.

A strength monitoring with wireless sensor network based on equivalent age method depending on the usage of the insulated formwork during the winter period (동절기 단열 유·무 거푸집을 설치한 슬래브 콘크리트에서 등가재령 기반의 무선센서 네트워크를 이용한 강도 모니터링)

  • Lee, Young-Jun;Lee, Hyuk-Ju;Hyeon, Seung-Yong;Seo, Hang-Goo;Lee, Sang-Woon;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.167-168
    • /
    • 2018
  • In this research, the feasibility of wireless senor for compressive strength evaluation was checked by applying on the actual apartment construction site with insulation formwork during winder period. As a result, there was no significant problem on monitoring the compressive strength of the concrete with the sensor. Thus it is considered that the suggested method can be an efficient method for the quality control at the construction site.

  • PDF

Wind-induced response and loads for the Confederation Bridge -Part II: derivation of wind loads

  • Bakht, Bilal;King, J. Peter C.;Bartlett, F.M.
    • Wind and Structures
    • /
    • v.16 no.4
    • /
    • pp.393-409
    • /
    • 2013
  • This paper uses ten years of on-site monitoring data for the Confederation Bridge to derive wind loads and investigate whether the bridge has experienced its design wind force effects since its completion in 1997. The load effects derived using loads from the on-site monitoring data are compared to the load effects derived using loads from the 1994 and 2009 wind tunnel aerodynamic model tests. The research shows, for the first time, that the aerodynamic model-based methodology originally developed in 1994 is a very accurate method for deriving wind loads for structural design. The research also confirms that the bridge has not experienced its specified (i.e., unfactored) wind force effects since it was opened to traffic in 1997, even during the most severe event that has occurred during this period.

The Effects of Self-management on Supervisory Behaviors at a Construction Site (자기-관리 기법이 건설 현장 일선 관리자들의 안전 관리 행동에 미치는 영향)

  • Lee, Kyehoon;Lee, Jaehee;Moon, Kwangsu;Oah, Shezeen
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.6
    • /
    • pp.151-159
    • /
    • 2012
  • This study implemented self-management technique to improve supervisory behaviors at a construction site. Self-management in the current study consisted of goal setting, self-monitoring and providing reward for two supervisory behaviors; (1) conducting safety observations of workers safety behavior and (2) providing safe related feedback. Two supervisors severed as participants. An AB within-group design was adopted. After baseline(A), self-management technique was implemented(B). Results suggested that self-management was effective in increasing the two supervisory behaviors. Moreover, the increased supervisory behaviors were associated with improvement in workers' safety performance.