• Title/Summary/Keyword: site measurement

Search Result 1,429, Processing Time 0.029 seconds

Long-Term Measurement under the Moving train at the Test Reinforced Roadbed Site in Railway (철도강화노반 시험부설구간에서의 열차 주행시 장기거동 계측)

  • 황선근;신민호;이성혁;최찬용;이시한
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.03a
    • /
    • pp.223-230
    • /
    • 2001
  • Nine different types of the reinforced railroad roadbeds which . are located in between Suwon-Chunan station of Kyongbu line were constructed in order to increase the bearing capacity of railroad roadbed and to improve the ridability as a part of speed-up project of conventional railroad systems. Each three sections were composed of weathered granite soil, crushed stone and furnace slag(HMS25), and fully instrumented with earth pressure cells, settlement plates and geophones to monitor the behavior of roadbeds under actual train loads. Field measurement has continued since October 31, 2000 and presently with rather longer measurement interval. The measurement data such as settlement, earth pressure and vibration levels are currently under analysis process. In this paper, only cumulative measurement data of railroad roadbeds were introduced. In the near future, comprehensive measurement data and result of analysis will be presented and design technique for the reinforced railroad roadbed will be proposed as a final product of this study.

  • PDF

On-site Water Nitrate Monitoring System based on Automatic Sampling and Direct Measurement with Ion-Selective Electrodes

  • Kim, Dong-Wook;Jung, Dae-Hyun;Cho, Woo-Jae;Sim, Kwang-Cheol;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.42 no.4
    • /
    • pp.350-357
    • /
    • 2017
  • Purpose: In-situ monitoring of water quality is fundamental to most environmental applications. The high cost and long delays of conventional laboratory methods used to determine water quality, including on-site sampling and chemical analysis, have limited their use in efficiently managing water sources while preventing environmental pollution. The objective of this study was to develop an on-site water monitoring system consisting mainly of an Arduino board and a sensor array of multiple ion selective electrodes (ISEs) to measure the concentration of $NO_3$ ions. Methods: The developed system includes a combination of three ISEs, double-junction reference electrode, solution container, sampling system consisting of three pumps and solenoid valves, signal processing circuit, and an Arduino board for data acquisition and system control. Prior to each sample measurement, a two-point normalization method was applied for a sensitivity adjustment followed by an offset adjustment to minimize the potential drift that could occur during continuous measurement and standardize the response of multiple electrodes. To investigate its utility in on-site nitrate monitoring, the prototype was tested in a facility where drinking water was collected from a water supply source. Results: Differences in the electric potentials of the $NO_3$ ISEs between 10 and $100mg{\cdot}L^{-1}$ $NO_3$ concentration levels were nearly constant with negative sensitivities of 58 to 62 mV during the period of sample measurement, which is representative of a stable electrode response. The $NO_3$ concentrations determined by the ISEs were almost comparable to those obtained with standard instruments within 15% relative errors. Conclusions: The use of the developed on-site nitrate monitoring system based on automatic sampling and two-point normalization was feasible for detecting abrupt changes in nitrate concentration at various water supply sites, showing a maximum difference of $4.2mg{\cdot}L^{-1}$ from an actual concentration of $14mg{\cdot}L^{-1}$.

A Study on Optimal Web Site Selection and Quality Evaluation Using AHP (AHP기법을 이용한 최적의 웹사이트 선정 및 품질 평가에 관한 연구)

  • Oh, Kie-Sung
    • The KIPS Transactions:PartD
    • /
    • v.11D no.2
    • /
    • pp.381-386
    • /
    • 2004
  • Because of rapid increase of internet user, numerous popular web sites have been made on the internet but it is hard to find out a systematic technique for the selection of qualified web site in consumer position. Generally, there are black box, white box and gray box viewpoint for evaluating web site. In this paper present evaluation criteria based on AHP(Analysis Hierarchy Process) technique of black box viewpoint for optimal web site selection in consumer position. We considered usability, efficiency, compatibility based on ISO/IEC 9126 for quality measurement of web site and executed practical analysis about web site in internet. This paper show that the proposed selection technique is applicable to optimal web site selection.

Accuracy Evaluation and Alert Level Setting for Real-time Cyanobacteria Measurement Using Receiver Operating Characteristic Curve Analysis (ROC 분석을 이용한 수질자동측정소 실시간 남조류 측정의 정확성 평가 및 경보기준 설정)

  • Song, Sanghwan;Park, Jong-hwan;Kang, Tae-Woo;Kim, Young-Suk;Kim, Jihyun;Kang, Taegu
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.2
    • /
    • pp.130-139
    • /
    • 2017
  • With the need to evaluate accuracy of real-time measurement of cyanobacterial fluorescence to determine cyanobacterial blooms, this research examined 357 paired data (2013-2016) comprising both microscopic toxic cyanobacterial cell counts and concurrent real-time cyanobacterial concentrations at 2 sites (YS1 and YS2) in Yeongsan river. The increase in real-time cyanobacterial concentration was closely associated with the exceedance of 5,000 cyanobacterial cells/ml (odds ratio [OR] 1.07, 95% confidence interval [CI] 1.03-1.12) and 10,000 cells/ml (OR 1.08, 95% CI 1.04-1.12) at YS2 site. The area under the receiver operating characteristic (ROC) curve for the real-time cyanobacterial measurement at the YS2 site was 0.93, which indicates the measurement provides a high accurate detection of cyanobacterial blooms. On the ROC curve, the early alert levels of real-time cyanobacteria ranging $16-23{\mu}g$ chl-a/L would produce acceptable sensitivity of 79% and specificities greater than 90%. The real-time fluorescence measurement was found to be an accurate indicator of cyanobacteria and can serve as a tool for detecting toxic cyanobacterial bloom events in Youngsan river.

Case Study of Coordinate Measurement during Construction of Long-Span Irregular Curved Roof Layers (장경간 비정형 곡면 지붕층의 시공중 좌표 계측 사례 연구)

  • Shim, Hak-Bo;Seok, Won-Kyun;Park, Soon-Jeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.11a
    • /
    • pp.14-15
    • /
    • 2019
  • In this paper, it was tried to prove the possibility and effect of coordinate measurement by using MEP layout equipment at the construction stage, and to propose a method to improve measurement accuracy during construction. For this study, the passenger terminal site, which is a long span structure, was selected and compared with three dimensional CAD drawings and construction measurement results using MEP layout equipment for the precise construction of long-span irregular curved roof layers. As a result, it was found that it is possible to construct three-dimensional curved roof layers using MEP layout equipment through measurement and analysis.

  • PDF

A study on gingival blood flow change of free gingival graft sites using Laser Doppler Flowmetry (Laser Doppler Flowmetry를 이용한 유리치은이식술 부위의 치은혈류 변화에 관한 연구)

  • Chun, Dong-Young;Park, Byung-Ki;Yeom, Chang-Yeob;Kim, Se-Hun;Kim, Jae-Deok;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.32 no.2
    • /
    • pp.291-302
    • /
    • 2002
  • In most of the previous studies, invasive and discrete techniques have been used to monitor the healing process of the gingival graft. However, Laser Doppler Flowmetry(LDF, floLAB(R), Moor Instruments Ltd., England) is a non-invasive technique for measurement of blood flow in the tissue and also allows continuous monitoring. Thus, we tested the usefulness of LDF in monitoring the healing process of free gingival graft at gingival recession. Eleven gingival graft site of 7 patients, including 5 males and 2 females, aged between 21 and 41 years (mean age 28.5) were monitored for the blood flow. The blood flow in gingival graft at coronal site, central site, apical site, mesial site and distal site was measured using LDF. Blood flow was measured at 1- week, 2- week, 3- week and 4- week after gingival graft surgery from 10 a.m. to 2 p.m. Time-course of the healing process was evaluated by statistical analysis using repeated ANOVA and Duncan test. The results were as follows : (1) Blood flow stayed increased for 2 weeks, and then, it was a tendency to decrease. (2) The blood flow at distal site had always higher than mesial site during the measuring periods. (3) The blood flow was high orderly after 1 week ; most coronal site, most apical site, central site. But that was high orderly after 2 week, 3 week, 4 week ; most coronal site, central site, most apical site. In conclusion, LDF was a useful and clinically adaptable method to monitor wound healing process. Our study suggested that it was important to protect surgical site to promote initial wound healing.

Application of Photogrammetry Method to Measurement of Ground-Surface Displacement on the Slope (사면의 지표변위계측을 위한 사진측량기법의 적용)

  • Han, Jung-Geun;Bae, Sang-Ho;Oh, Da-Young
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.4 no.3
    • /
    • pp.10-18
    • /
    • 2001
  • The existing measurement system to ground-surface displacement survey of the slope has been including the hazard for the measure in site and the difficulty for install, maintenance and control of expensive instruments, which are impossible of whole survey on the slope surface. To overcome of those defects, Softcopy Photogrammertry method is used, which can measure displacement of ground-surface on the slope and structure deformation vectors. Recently, the survey methods applying the advantages of Photogrammetry and Digital Photogrammetry Survey are widely used. In this study, therefore, the development and application of the new instrument mechanism on the the site example are studied. Through the application of Softcopy Photogrammetry, the 3-D data of ground surface on the dangerous slope could be effectively obtained at the long distance, which are obtained through the reform process of contour line. Those are different to the results of the Close-Range Photogrammetry analysis. In ground instrumentation parts, the new practical system shall be the technical base to improve of the instrument machine as well as can be widely applied in civil engineering and others branch.

  • PDF

A Case Study on Construction of Tunnel at Limestone Cavity Site (석회암공동 분포지역에서의 터널 시공사례)

  • Kim, Si-Kyeok;Kang, In-Seop;Kim, Yong-Ha;Yoon, Il-Byung;Moon, Hoon-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.10a
    • /
    • pp.66-75
    • /
    • 2006
  • As construction for road tunnel is increasing, various geotechnical conditions can be faced during the construction stage. Especially, if the tunnel is located in limestone area, many kinds of site investigations such as in-situ boring, electrical resistance survey, TSP(Tunnel Seismic Prediction) and etc., are conducted before and during the construction. By conducting these preliminary tests, location, size, and filling materials in limestone cavities can be approximately estimated. Once some cavities which can be harmful for tunnel safety are predicted, methods for ground reinforcement and tunnel excavation, corresponding those ground conditions, have to be established and verified by measurement data and numerical analysis. If necessary, invert lining should be also considered. In this paper, by studying some cases of tunnels constructed in limestone area, predicted problems during construction and rational countermeasures for those are presented.

  • PDF

Appropriate Input Earthquake Motion for the Verification of Seismic Response Analysis by Geotechnical Dynamic Centrifuge Test (동적원심모형 시험을 이용한 부지응답해석 검증시 입력 지진의 결정)

  • Lee, Jin-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.5
    • /
    • pp.209-217
    • /
    • 2013
  • In order to verify the reliability of numerical site response analysis program, both soil free-field and base rock input motions should be provided. Beside the field earthquake motion records, the most effective testing method for obtaining the above motions is the dynamic geotechnical centrifuge test. However, need is to verify if the motion recorded at the base of the soil model container in the centrifuge facility is the true base rock input motion or not. In this paper, the appropriate input motion measurement method for the verification of seismic response analysis is examined by dynamic geotechnical centrifuge test and using three-dimensional finite difference analysis results. From the results, it appears that the ESB (equivalent shear beam) model container distorts downward the propagating wave with larger magnitude of centrifugal acceleration and base rock input motion. Thus, the distortion makes the measurement of the base rock outcrop motion difficult which is essential for extracting the base rock incident motion. However, the base rock outcrop motion generated by using deconvolution method is free from the distortion effect of centrifugal acceleration.

Impact of MJS treatment and artificial freezing on ground temperature variation: A case study

  • Jiling, Zhao;Ping, Yang;Lin, Li;Junqing, Feng;Zipeng, Zhou
    • Geomechanics and Engineering
    • /
    • v.32 no.3
    • /
    • pp.293-305
    • /
    • 2023
  • To ensure the safety of underground infrastructures, ground can sometimes be first treated by cement slurry and then stabilized using artificial ground freezing (AGF) technique before excavation. The hydration heat produced by cement slurry increases the soil temperature before freezing and results in an extension of the active freezing time (AFT), especially when the Metro Jet System (MJS) treatment is adopted due to a high cement-soil ratio. In this paper, by taking advantage of an on-going project, a case study was performed to evaluate the influence of MJS and AGF on the ground temperature variation through on-site measurement and numerical simulation. Both on-site measurement and simulation results reveal that MJS resulted in a significant increase in the soil temperature after treatment. The ground temperature gradually decreases and then stabilized after completion of MJS. The initiation of AGF resulted in a quick decrease in ground temperature. The ground temperature then slowly decreased and stabilized at later freezing. A slight difference in ground temperature exists between the on-site measurements and simulation results due to limitations of numerical simulation. For the AGF system, numerical simulation is still strongly recommended because it is proven to be cost-effective for predicting the ground temperature variation with reasonable accuracy.