• Title/Summary/Keyword: site measurement

Search Result 1,429, Processing Time 0.044 seconds

e-CRM을 위한 B2C Web Site 고객행동모델 분석 및 평가방법에 관한 연구

  • 이경록;서장훈;박명규
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2002.11a
    • /
    • pp.239-246
    • /
    • 2002
  • In this report, we provide the focus on suggesting a method of estimating & measurement of CBM(Customer Behavior Model). Through the use of internet, a new trend of business for e-CRM on B2C Web Site which is now known as EC has emerged. The Purpose of this study is to identify the relationship between the customers of a shopping mall and CBM characteristics. Result showed that there is a significant relationship between the some customers pattern of shopping mall and CBM, CVM(Customer Visit Model).

  • PDF

RHODIUM SELF-POWERED NEUTRON DETECTOR'S LIFETIME FOR KOREAN STANDARD NUCLEAR POWER PLANTS

  • YOO CHOON SUNG;KIM BYOUNG CHUL;PARK JONG-HO;FERO ARNOLD H.;ANDERSON S. L.
    • Nuclear Engineering and Technology
    • /
    • v.37 no.6
    • /
    • pp.605-610
    • /
    • 2005
  • A method to estimate the relative sensitivity of a self-powered rhodium detector for an upcoming cycle is developed by combining the rhodium depletion data from a nuclear design with the site measurement data. This method can be used both by nuclear power plant designers and by site staffs of Korean standard nuclear power plants for determining which rhodium detectors should be replaced during overhauls.

The Estimation of Soil Conversion Factor using Digital Imagery (수치영상을 이용한 토량환산계수 산정)

  • 이종출;차성렬;장호식;김진수
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.169-174
    • /
    • 2003
  • Design of a rational earth volume conversion coefficient is required as the earth volume conversion coefficient may give great influence on construction work volume and construction costs in the civil engineering works where large-scaled earth volume is excavated. However, there are a great deal of difficulties in the calculation of the exact spoil surface earth and Insufficient earth volume by adopting the figures presented on the generally used design specifications which are not the results obtained from the selection tests in calculating the earth volume conversion coefficient. In this connection, it would be desirable to calculate the earth volume conversion coefficient by carrying out large-scaled site test adequate for the relevant environment. In consequence, this study aims at calculating the exact earth volume conversion coefficient of cutting and banking areas of weathering rocks in large-scaled construction sites where land is being developed into home lots. For this, we have excavated the respective 20 sites of the cutting and banking areas in the said site and then calculated the volume after the excavation. As a result, the relative exactness degree of the crossing was calculated at 0.5% in average. The relative exactness degree of 0.5% in the volume may be judged as an exact measurement as it corresponds to 0.17% of the relative exactness degree in the length measurement. We have calculated the exact earth volume conversion coefficient by the use of function ratio as per the wet unit weight and the indoor soil quality test as per volume calculated. And then we have found out minor differences as a result of the comparison and analysis with the earth volume conversion coefficient determined by the dry unit weight test as per sand replacement method. This may be judged as a rational design method for the calculation of earth volume conversion coefficient, as well as high reliability of site test as a precision photogrammetry is adopted for volume measurement of the irregular excavating areas.

  • PDF

On-site Performance Evaluation of a Vision-based Displacement Measurement System (영상 기반 변위 계측장치의 현장 적용 성능 평가)

  • Cho, Soojin;Sim, Sung-Han;Kim, Eunsung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5854-5860
    • /
    • 2014
  • The on-site performance of a vision-based displacement measurement system (VDMS) was evaluated through a field test on a bridge. The VDMS used in this study is composed of a camera, a marker, a frame grabber, and a laptop. The system measures the displacement by attaching a marker at the location to be measured on the structure, by capturing images of that marker with a fixed rate, and by processing a series of images using a planar homography technique. The developed system was first validated from a laboratory test using a small-scale building structure. The VDMS was then employed in a field test on a railroad bridge with a KTX train running under various conditions. The on-site performance was evaluated by comparing the obtained displacement using the VDMS with the displacement measured from a laser Doppler vibrometer (LDV), which is an expensive and accurate displacement measurement device.

Behavior of Suspended Solids for the Development of Coastal Industrial Complex (해안지역 산업단지조성 따른 해양 부유물질 거동에 관한 연구)

  • Kim, Ki-Dam;Lee, Joong-Woo;Lee, Hak-Seung;Kang, Seok-Jin;Jeon, Min-Su
    • Journal of Navigation and Port Research
    • /
    • v.32 no.6
    • /
    • pp.489-497
    • /
    • 2008
  • The government is now driving a policy that development of industrial complex site for the local manufacturing industry by reengineering and expanding the existing sites or reclamation of coastal zone. Therefore, it is necessary to analyze the impact of the coastal reclamation work in terms of physical and environmental characteristics. This study is also dealing with the impact of coastal reclamation for national industrial complex site to the ocean physical characteristics, variation of sedimentation and diffusion system and marine environment from the analysis of the field measurement and numerical simulation. The site for application is at the coastal boundary near Onsan national industrial complex, Ulsan metro city. In order to verify the numerical simulation result, it is compared to the collected data for tide, current, and sediments of the existing measurement and field observation at the selected stations for this study. The verified numerical models were applied to the actual field and the future change was analyzed.

A Practical Measurement Method of the Occupied Bandwidth for 8-VSB DTV Signal Using Modified ACPR

  • Kim, Young Soo;Lee, Bong Gyou;Song, Kyeongmin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.7
    • /
    • pp.3550-3565
    • /
    • 2019
  • This paper proposes a new measurement method for the effective measurement of the 99% occupied bandwidth (OBW) at monitoring stations. Although the OBW measurement of radio signal is recommended by the International Telecommunication Union Radio (ITU-R) with several methods, there still does not exist a clear measurement recommendation or standard for terrestrial DTV signal on-air environment. Modified adjacent channel power ratio (MACPR), which can be applied to 8-VSB (Vestigial Side Band) DTV (Digital Television) signal, is herein defined to verify the results of measurements obtained using the proposed measurement method. MACPR is a proper measuring parameter for determining the measuring area of a monitoring station. From measurement results obtained in real field environment, it has been found that the OBW of 8-VSB DTV signal can be effectively measured in areas where the MACPR value is over 35 dB and when the measurements are repeated more than 600 times in the same reception site. It also has been verified that measured results are within an error range of +/-0.1% compared to results directly obtained at a transmission station. It is expected that the proposed method is able to be employed in order to determine the proper location of monitoring station and provide a reliable OBW measurement procedure for 8-VSB DTV signal on-air environment.

Analysis of the wastewater characteristics variation in sewerage by rehabilitation (관거 정비에 따른 하수발생특성 분석)

  • Jung, SiMon;Park, InHyeok;Park, JungHa;Ha, SungRyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.3
    • /
    • pp.287-293
    • /
    • 2009
  • The study involved the measurement of flowrate and BOD in the Yeoju area and analyzed annual sewerage data by the I/I analysis technique which is common in Korea. The results of this study are as follows. The I/I for the Y-1 site before maintenance and after the completion of the whole process was reduced from 62% to 16.1% respectively with respect to maximum sewage flow per day. The average quality of water increased. The study measured the Y-2 site from a point of time corresponding to an 80% process rate and its I/I rate went up a little from 8.5% to 11.5%. At the Y-3 site, the I/I rate went up a little from 11% to 13.8%, while little change was noted in the average water quality. At the Y-4 site, the I/I rate was reduced from 43% to 16.9% and its average water quality went up. At the Y-5 site, the I/I quantity went up a little however its average water quality also went up largely. Therefore, it was concluded that the Y-5 site showed great improvement due to the sewer pipe maintenance.

A Study on Development of GNSS-based Measurement System for Monitoring Slope Site

  • Lee, jin-duk;Chang, ki-tae;Bhang, kon-joon
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.5-6
    • /
    • 2015
  • A GNSS based measurement system was constructed with not only the core sensors of a GNSS receiver, a TRS sensor and a soil moisture sensor but supplementary installation of power supply and radio communication for monitoring steep slope sites. The sensor combination extracts and transfers not only ground displacement in real-time but soil moisture content.

  • PDF

A Study on the Odor Compounds Emitted using Odor Contribution Analysis - Focus on the Ochang Scientific Industrial Complex Area - (악취기여도평가를 이용한 악취원인물질 연구 - 오창과학산업단지를 중심으로 -)

  • Jung, Ji-Sun;Kim, Duk-Chul;Lee, Han-Chul;Yeon, Seoung-Won;Yeon, Ik-Jun
    • Journal of Environmental Science International
    • /
    • v.25 no.9
    • /
    • pp.1329-1339
    • /
    • 2016
  • The purpose of this study was to obtain the basic data needed to identify the impact of the odor, emitted from the Ochang Scientific Industrial Complex area on the surrounding residential areas by measuring and confirming odor compounds. The analysis showed that complex odors were diluted from around 4 to 1. The offensive odor measurement results showed that among the sites, site 1 was highest in sulfur compounds, site 2 was highest in toluene, site 3 was highest in trimethylamine, and site 4 was highest in buthylaldehyde. It cannot be decided to be odor-causing compounds for higher odor concentration because each odor substance has a different odor threshold value. According to the odor contribution analysis for each site, site 1, site 2, and site 4 contained high buthylaldehyde concentrations, and site 3 had a high level of trimethylamine. It could be determined that highly evaluated substances were main causes to result in substance for each site.

Comparison of Two Intramuscular Injection Techniques on the Severity of Discomfort and leasions at the Injection Site (근육주사법에 따른 주사부위의 불편감과 조직손상의 차이에 관한 연구)

  • 김경선
    • Journal of Korean Academy of Nursing
    • /
    • v.18 no.3
    • /
    • pp.257-268
    • /
    • 1988
  • The purpose of this study was to compare the effect of the Z-track intramuscular injection technique with the effect of the stand and intramuscular injection technique on the severity of discomfort and leasions at the injection site. The subjects of the study were 20 patients with only early tuber culosis excluding another abnormalities (a akin rash, allergy to topical use of alcohol, jaundice, edema, neurosensory abnormality, coagulation defects, obesity and thin). Data collection was done from Feb. 1 to March 15, 1988 by means of Korean Pain Measurement Tool, Visual Analogue Scale, and Objective measures of injection site lesions. The results of this study were as follows ; 1) Hypothesis 1 ; “The severity of subject discomfort is less following administration of the Z-track intramuscular injection technique than following administra tion injection technique.” was not sopported 2) Hypothesis 2 ; “The degress of severity subject discomfort is less following administration of the Z-track intramuscular injection technique than following administra tion of the standard intramuscular injection technique.” was not supported. 3) Hypothesis 3 ; “The severity of injection site lesions is less following administra tion of the Z-track intramuscular injection technique than following administration of the standard intramuscular injection techniques.” was not supported. 4) The terms that were selected included factor II (mild-moderate pain) of Ratio Scale Measuring Pain using Korean Pain Terms. In conclusion ; it was found that there was not a difference from the severity of subject discomfort between two groups, but the degress of severity of subject discomfort about following administration of the Z-t-rack intramuscular injection was tended to be declined. Therefore further studies suggest that the Z-track intramuscular injection technique can decrease the severity of discomfort in persons receiving frequently intramuscular injections. First of all, it is necessery to be developed an effective tool of discomfort measurement for the intramuscular injection in Korean.

  • PDF