• Title/Summary/Keyword: site coefficient

Search Result 715, Processing Time 0.034 seconds

Development of Site Classification System and Modification of Design Response Spectra Considering Geotechnical Characteristics in Korea

  • Kim, Dong-Soo;Yoon, Jong-Ku
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.4
    • /
    • pp.65-77
    • /
    • 2007
  • Site response analyses were performed based on equivalent linear technique using shear wave velocity profiles of 162 sites collected around the Korean peninsula. The site characteristics, particularly the shear wave velocities and the depth to the bedrock, are compared to those in the western United States. The results show that the site-response coefficients based on the mean shear velocity of the top 30m ($V_{S30}$) suggested in the current code underestimates the motion in short-period ranges and overestimates the motion in mid-period ranges. The current Korean code based on UBC is required to be modified considering site characteristics in Korea for the reliable estimation of site amplification. From the results of numerical estimations, new regression curves were derived between site coefficients ($F_{a}\;and\;F_{v}$) and the fundamental site periods, and site coefficients were grouped based on site periods with reasonable standard deviations compared to site classification based on $V_{S30}$. Finally, new site classification system and modification of design response spectra are recommended considering geotechnical characteristics in Korea.

Operation Cost Comparison of Dedicated Outdoor and Cooling + reheating Air-conditioning Systems by On-site Performance Test (현장성능시험에 의한 외기전용과 냉각식 + 재열 공조기의 운전비 비교)

  • Kim, Young-Il;Kim, Jung-Min;Chung, Kwang-Seop;Park, Seung-Tae
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.2
    • /
    • pp.37-42
    • /
    • 2011
  • Dedicated outdoor air(DOA) system which conditions the outdoor air separately is superior to conventional Cooling + reheating system with respect to energy consumption and indoor comfort. Since the sensible and latent load characteristics of indoor and outdoor are different, it is more efficient to treat them separately. In this study, cycle analysis and on-site performance test of DOA system have been conducted. The study shows that DOA requires 50% less equivalent energy than the conventional system. The on-site performance test of a prototype shows that the coefficient of performance(COP) of the DOA system is 37% higher than the conventional system.

The Performance Analysis and On-site Performance Test of a Dedicated Outdoor Air System (외기 전용 공조기의 성능 분석 및 현장 성능시험)

  • Kim, Young-Il;Kim, Jung-Min;Chung, Kwang-Seop;Park, Seung-Tae
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.346-351
    • /
    • 2007
  • Dedicated outdoor air(DOA) system which conditions the outdoor air separately is superior to conventional cooling+reheating system with respect to energy consumption and indoor comfort. Since the sensible and latent load characteristics of indoor and outdoor are different, it is more efficient to treat them separately. In this study, cycle analysis and on-site performance test of DOA system have been conducted. The study shows that DOA requires 48.8% less equivalent energy that conventional system. The on-site performance test of the prototype shows that the coefficient of performance(COP) of the DOA system is 37.4% higher than the conventional system.

  • PDF

Analysis on Correlation Coefficient of Surface Image Velocimeter (SIV) Using On-site Runoff Image (현장유출영상을 활용한 표면영상유속계(SIV)의 상관계수 분석)

  • Kim, Yong-Seok;Yang, Sung-Kee;Kim, Dong-Su;Kim, Seojun
    • Journal of Environmental Science International
    • /
    • v.24 no.4
    • /
    • pp.403-414
    • /
    • 2015
  • This study is daytime and nighttime runoff image data caused by heavy rain on May 27, 2013 at Oedo Water Treatment Plant of Oedo-Stream, Jeju to compute runoff by applying Surface image velocimeter (SIV) and analyzing correlation according to current. At the same time, current was comparatively analyzed using ADCP observation data and fixed electromagnetic surface current meter (Kalesto) observed at the runoff site. As a result of comparison on resolutions of daytime and nighttime runoff images collected, correlation coefficient corresponding to the range of 0.6~0.7 was 6.8% higher for nighttime runoff image compared to daytime runoff image. On the contrary, correlation coefficient corresponding to the range of 0.9~1.0 was 17% lower. This result implies that nighttime runoff image has lower image quality than daytime runoff image. In the process of computing current using SIV, a rational filtering process for correlation coefficient is needed according to images obtained.

Estimation of Site Index for Larix kaempferi and Pinus koraiensis in Gangwon and North Gyeongsang Provinces

  • Lee, Daesung;Seo, Yeongwan;Park, Gildong;Choi, Jungkee
    • Journal of Forest and Environmental Science
    • /
    • v.31 no.3
    • /
    • pp.202-206
    • /
    • 2015
  • Site index curves were developed for Larix kaempferi and Pinus koraiensis in Gangwon and North Gyeongsang provinces in Korea. For the development of site index, Schumacher and Chapman-Richards model were applied using the data collected from 2012 to 2014. Base age was set to 40 years for Larix kaempferi and Pinus koraiensis in site index of this study. Coefficient of determination and root mean square error of site index models were provided by species, and the models were compared with the previous studies to check the suitability. Overall, site index models developed in this study fitted in the current data well. Thus, the site indexes are considered to be properly used in Gangwon and North Gyeongsang provinces.

Modification of Design Response Spectra Considering Geotechnical Site Characteristics in Korea (국내 지반특성에 적합한 설계응답스펙트럼 개선을 위한 증폭계수 재산정에 대한 연구)

  • Yoon, Jong-Ku;Kim, Dong-Soo;Bang, Eun-Seok
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.113-124
    • /
    • 2006
  • Despite the site classification method was improved in the previous study, the response spectrum would be required to be modified by adjusting the integration interval to calculate the site coefficients because the response spectra did not match well the average spectral accelerations obtained by site response analyses in the range of long periods. In this paper, new response spectra for each site categories were determined by adjusting the integration interval of long-period site coefficient $F_{v}$ from $0.4{\sim}2.0$ to $0.4{\sim}1.5$ second. It matched well the average spectral accelerations and new response spectrum, and it was also improved compared to the current site classification system.

  • PDF

Reduction Factor for the Site Coefficient of a Building built on a Poor-backfilled Embedded Foundation (뒷채움이 부실한 묻힌기초 위에 세워진 건축물의 지반증폭계수에 대한 저감계수)

  • Kim, Yong-Seok
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.1-12
    • /
    • 2012
  • In this paper, the reduction factors to calculate the site coefficients of an embedded foundation are estimated, considering the effect of a poor backfill for the seismic design of a building built on an embedded foundation. This is determined by utilizing in-house finite element software, P3DASS, which has the capability of horizontal pseudo 3D seismic analysis with nonlinear soil. The 30m thick soil on stiff rock was assumed to be homogeneous, elastic, viscous and isotropic, and equivalent circular rigid foundations with radii of 10-70m were assumed to be embedded 0, 10, 20, and 30 m in the soil. Seismic analyses were performed with 7 bedrock earthquake records de-convoluted from the outcrop records; the scaling of the peak ground accelerations were to 0.1 g. The study results show that the site coefficients of a poor-backfilled foundation are gradually reduced as the foundation embedment ratio increases, except in the case of a small foundation embedded deeply in the weak soft soil. In addition, it was found that the deviation of the site coefficients due to the foundation size was not significant. Therefore, the typical reduction factors of an embedded foundation with poor backfill are proposed in terms of the shear wave velocity and site class. This is in order to find the site coefficients of an embedded foundation by multiplying the reduction factor by a site coefficient of a surface foundation specified in the design code. They can then be interpolated to determine the intermediate shear wave velocity.

Method of extracting context from media data by using video sharing site

  • Kondoh, Satoshi;Ogawa, Takeshi
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.709-713
    • /
    • 2009
  • Recently, a lot of research that applies data acquired from devices such as cameras and RFIDs to context aware services is being performed in the field on Life-Log and the sensor network. A variety of analytical techniques has been proposed to recognize various information from the raw data because video and audio data include a larger volume of information than other sensor data. However, manually watching a huge amount of media data again has been necessary to create supervised data for the update of a class or the addition of a new class because these techniques generally use supervised learning. Therefore, the problem was that applications were able to use only recognition function based on fixed supervised data in most cases. Then, we proposed a method of acquiring supervised data from a video sharing site where users give comments on any video scene because those sites are remarkably popular and, therefore, many comments are generated. In the first step of this method, words with a high utility value are extracted by filtering the comment about the video. Second, the set of feature data in the time series is calculated by applying functions, which extract various feature data, to media data. Finally, our learning system calculates the correlation coefficient by using the above-mentioned two kinds of data, and the correlation coefficient is stored in the DB of the system. Various other applications contain a recognition function that is used to generate collective intelligence based on Web comments, by applying this correlation coefficient to new media data. In addition, flexible recognition that adjusts to a new object becomes possible by regularly acquiring and learning both media data and comments from a video sharing site while reducing work by manual operation. As a result, recognition of not only the name of the seen object but also indirect information, e.g. the impression or the action toward the object, was enabled.

  • PDF

Variations of Secchi Depth in Coastal Water, Masan Bay in Korea (마산만의 투명도 변동)

  • 염말구;정연수
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.1
    • /
    • pp.44-49
    • /
    • 2003
  • Masan Bay is one of the most heavily polluted bay in Korea owing to the large industrial complex and urban area. Water transparency, Secchi depth in meter, was observed 33 times totally at four sites during 1995 through 2002 and analysed statistically. The range was 0.2∼7.2m, mean 204m, and variation coefficient 60% in totally. Roughly speaking, monthly mean showed lower value April or July than other months. Seasonal mean showed lower in spring or summer than other seasons. Yearly mean was lowest in '95 and '98 during 7 years. Each sampling site showed a different patterns by the monthly, seasonal or yearly transparencies. Inner bay area, S1 site, showed lowest transparency and highest variation coefficient owing to the streamlets and urban area. And it was supposed that one of the important factor affecting different transparency distribution of most seaward site, S4 site, among four sites in the Masan Bay may be the underwater effluents of urban sewage water treated.

The Study on the Variation of Pass-by-Noise level due to ISO Road (ISO 노면의 Pass-by-Noise Level 편차에 관한 연구)

  • 김기전;배철용;노국희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.11a
    • /
    • pp.371-376
    • /
    • 2003
  • The objective of this paper is to compare the site-to-site variability of ISO 10844 pass-by-noise test sites. In order to investigate the site-to-site variance of test surfaces, European commercial tires are tested at seven different test sites. Three Korea test sites and four Europe test sites are selected.. The pass by noise test is executed according to a 2001/43/EC regulation. A]though the ISO surface has a very specific track composition, it does not reduce the variation of pass-by-noise measurements over the surface of test sites. This paper shows that the test results of pass-by-noise level are different depending on the test sites. The correlation obtained in this work is able to predict the pass by noise level for certain test site using the data measured from another test site. 17he prediction value is range with an error within 1dB(A).

  • PDF