• Title/Summary/Keyword: sinusoidal distortion

Search Result 115, Processing Time 0.022 seconds

Numerical Study on the Thermal Distortions of Ventilated Disk Brakes Due to Air Cooling Effects (벤틸레이티드 디스크 브레이크에서 공냉효과가 열변형 거동에 미치는 영향에 관한 수치적 연구)

  • 조승현;이일권;김청균
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.06a
    • /
    • pp.332-338
    • /
    • 1999
  • A coupled thermal-mechanical analysis has been presented for the thermal distortions of the ventilated disk brakes during IS braking operations. The FEM results show that the bendings and distortions of the disk toward the left side are decreased, but the sinusoidal distortion of the disk rubbing surface along the arc length of the vent hole is highly increased by increasing the convective air cooling effects, which is heavily related to the squeal, wear and micro-thermal crackings at the rubbing surfaces due to uneven dissipation rates of friction heatings.

  • PDF

A Cascaded Multilevel Inverter Using Bidirectional H-bridge Modules

  • Kang, Feel-Soon;Joung, Yeun-Ho
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.4
    • /
    • pp.448-456
    • /
    • 2012
  • This paper presents a multilevel inverter configuration which is designed by insertion of a bidirectional switch between capacitive voltage sources and a conventional H-bridge module. The modified inverter can produce a better sinusoidal waveform by increasing the number of output voltage levels. By serial connection of two modified H-bridge modules, it is possible to produce 9 output voltage levels including zero. There are 24 basic switching patterns with the 9 output voltage levels. Among the patterns, we select the 2 most efficient switching patterns to get a lower switching loss and minimum dv/dt stress. We then analyze characteristics of Total Harmonic Distortion (THD) of the output voltage with variation of input voltage by computer-aided simulations and experiments.

A Pulse Frequency Control of Single-switch Three-phase ZCS Buck Rectifiers (단일 스위치 3상 ZCS 강압형 정류기의 펄스 주파수 제어)

  • 송중호;김용덕;이동윤;최익;최주엽;유지윤
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.82-90
    • /
    • 1999
  • A pulse frequency control method for single-switch three-phase buck rectifiers is comprehensively studied in this paper. The proposed pulse frequency control method leads the three-phase buck rectifier to a high performance system that can draw the nearly sinusoidal input-line currents. The simulated and experimental results demonstrate that the system provides low total harmonic distortion of the input-line currents, high-power factor, and good output voltage regulation against load change.

An Improved Wavelet PWM Technique with Output Voltage Amplitude Control for Single-phase Inverters

  • Zheng, Chun-Fang;Zhang, Bo;Qiu, Dong-Yuan;Zhang, Xiao-Hui;Li, Rui
    • Journal of Power Electronics
    • /
    • v.16 no.4
    • /
    • pp.1407-1414
    • /
    • 2016
  • Unlike existing pulse-width modulation (PWM) techniques, such as sinusoidal PWM and random PWM, the wavelet PWM (WPWM) technique based on a Harr wavelet function can achieve a high fundamental component for the output voltage, low total harmonic distortion, and simple digital implementation. However, the original WPWM method lacks output voltage control. Thus, the practical application of the WPWM technique is limited. This study proposes an improved WPWM technique that can regulate output voltage amplitude with the addition of a parameter. The relationship between the additional parameter and the output voltage amplitude is analyzed in detail. Experimental results verify that the improved WPWM exhibits output voltage control in addition to all the merits of the WPWM technique.

Finite Element Analysis on the Dynamic Behaviors of a Disk-Pad Brake in High-Speed Trains (고속전철용 디스크-패드 브레이크의 동적거동 특성에 관한 유한요소해석)

  • 김청균;조승현
    • Tribology and Lubricants
    • /
    • v.16 no.2
    • /
    • pp.99-105
    • /
    • 2000
  • Using a coupled thermal-mechanical analysis, the dynamic distortion of the ventilated disk brakes has been presented for a high-speed train. The offset ratio between the maximum and minimum values of the thermal distortions has been analyzed as a function of a braking number. The computed FEM results show that the offset ratios in radial direction are much greater than those of circumferentially distorted components. This means that the axial distortions in radial direction may dominantly produce thermally caused wears and cracks at the rubbing surfaces.

Single-Phase 3-level PWM Inverter for Harmonics Reduction (고조파 저감을 위한 단상 3-레벨 PWM 인버터)

  • Gang, Pil-Sun;Park, Seong-Jun;Kim, Cheol-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.3
    • /
    • pp.125-132
    • /
    • 2002
  • This paper presents a single-phase 3-level PWM inverter to alleviate the harmonic components of output voltage and current under the conditions of identical supply DC voltage and switching frequency to the conventional inverter. Operational principles and analysis are performed, and the switching functions are derived. Deadbeat controller is also designed and implemented for the inverter to keep the output voltage being sinusoidal and to have the high dynamic performances even in the cases of load variations and the partial magnetization of filter inductor. The validity of proposed inverter is proved from the simulated and experimented results.

A Study on the Dynamic Behaviors of a Disk Brake for a High-Speed Train (고속전철용 디스크 브레이크의 동적거동 특성에 관한 연구)

  • 조승현;김청균
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.276-282
    • /
    • 1999
  • Using a coupled thermal-mechanical analysis, the dynamic distortion of the ventilated disk brakes has been presented for a high-speed train. The offset ratio between the maximum and minimum values of the thermal distortions has been analyzed as a function of a braking number. The computed FEM results show that the offset ratios in radial direction are much greater than those of circumferentially distorted components. This means that the axial distortions in radial direction may dominantly produce thermally caused wears and cracks at the rubbing surfaces.

  • PDF

A Study on the two phase sinusoidal voltage Controlled Oscillator with Low Distortion (저왜율을 갖는 2상정현파 전압제어 발진기에 관한 연구)

  • 이성백;이윤종
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.12 no.5
    • /
    • pp.527-534
    • /
    • 1987
  • Two phase voltage controlled oscillation was realized by using the Electronic analog simulation of nonlinear simultaneous 2st order equation in terms of vibration and it's usefullness was sustined. Sinde it is complex and expensive to implement the circuits actually which composits and multiplicate the two phase signal squared respectively, this paper is obtained the simplificotion and switching circuit. The circuit introducced in this paper had propotionality of frequency to control input voltage, rapid response time, and little phase error, also this circuit operated with very low THD(Total Harmonic Distortion) and constant amplitude at higher than 10 :1 of frequency ratio.

  • PDF

Parallel Operation of Space Vector PWM Inverters for Large Capacity Inverter System (대용량 인버터 시스템을 위한 공간벡터 PWM 인버터의 병렬 운전)

  • Ji, Jun-Geun;Lee, Hyeon-Dong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.509-513
    • /
    • 2000
  • This paper deals with the parallel operation of space vector PWM for large capacity inverter system. To enlarge the capacity of inverter system and to reduce the current ripples on inverter output side, two or more inverters are operated in parallel. In this paper, a new parallel operation strategy which minimizes the harmonic distortion of the output stage is described. The proposed method is developed on the basis of the space-vector PWM in order to increase the linearly controllable voltage range. With the help of the proposed voltage synthesis method, the total harmonic distortion of the output stage can be greatly reduced in compared with that of conventional method with sinusoidal PWM or that of the single inverter operation case. The experimental results with reduced scale test show the feasibility of the proposed voltage synthesis method.

  • PDF

A Study on Measurement and Analysis of Harmonics in Substation (변전소 고조파 측정 및 분석에 관한 연구)

  • Han Mu-Ho;Park Tae-Joon;Lee Seung-Hee;Lee Chi-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.438-441
    • /
    • 2001
  • Nonlinear loads change the sinusoidal nature of the ac power current, thereby resulting in the flow of harmonic currents in the ac power system that can cause interference with communication circuits and other type of equipment. To minimize the damage, it is needed to limit harmonics current and voltage. Harmonic measurement system was developed to measure individual voltage and current harmonic continuously and save harmonic data on computer. We measured all 154kV feeders in a steel making company substation. Voltage and current distortion limits for general transmission systems was suggested We found some feeders exceeded current distortion limits. As result voltage harmonic exceeded standard limits.

  • PDF