• 제목/요약/키워드: sinusoidal distortion

검색결과 115건 처리시간 0.025초

벤틸레이티드 디스크 브레이크에서 공냉효과가 열변형 거동에 미치는 영향에 관한 수치적 연구 (Numerical Study on the Thermal Distortions of Ventilated Disk Brakes Due to Air Cooling Effects)

  • 조승현;이일권;김청균
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제29회 춘계학술대회
    • /
    • pp.332-338
    • /
    • 1999
  • A coupled thermal-mechanical analysis has been presented for the thermal distortions of the ventilated disk brakes during IS braking operations. The FEM results show that the bendings and distortions of the disk toward the left side are decreased, but the sinusoidal distortion of the disk rubbing surface along the arc length of the vent hole is highly increased by increasing the convective air cooling effects, which is heavily related to the squeal, wear and micro-thermal crackings at the rubbing surfaces due to uneven dissipation rates of friction heatings.

  • PDF

A Cascaded Multilevel Inverter Using Bidirectional H-bridge Modules

  • Kang, Feel-Soon;Joung, Yeun-Ho
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권4호
    • /
    • pp.448-456
    • /
    • 2012
  • This paper presents a multilevel inverter configuration which is designed by insertion of a bidirectional switch between capacitive voltage sources and a conventional H-bridge module. The modified inverter can produce a better sinusoidal waveform by increasing the number of output voltage levels. By serial connection of two modified H-bridge modules, it is possible to produce 9 output voltage levels including zero. There are 24 basic switching patterns with the 9 output voltage levels. Among the patterns, we select the 2 most efficient switching patterns to get a lower switching loss and minimum dv/dt stress. We then analyze characteristics of Total Harmonic Distortion (THD) of the output voltage with variation of input voltage by computer-aided simulations and experiments.

단일 스위치 3상 ZCS 강압형 정류기의 펄스 주파수 제어 (A Pulse Frequency Control of Single-switch Three-phase ZCS Buck Rectifiers)

  • 송중호;김용덕;이동윤;최익;최주엽;유지윤
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.82-90
    • /
    • 1999
  • 본 논문은 단일 스위치 3상 ZCS 강압형 정류기의 펄스주파수 제어기법을 다루고 있다. 제안하는 펄스주파수 제어방법은 거의 정현적인 입력전류를 흐르게 하여 3상 강압형 정류기의 성능을 보여준다. 제안하는 제어구조의 유용성을 검증해 주는 시뮬레이션과 실험 결과는 단일 스위치 3상 ZCS 강압형 정류기의 고역율, 입력전류의 낮은 THD, 부하 변동에 대한 전압의 응답특성들이 뛰어남을 보여준다.

An Improved Wavelet PWM Technique with Output Voltage Amplitude Control for Single-phase Inverters

  • Zheng, Chun-Fang;Zhang, Bo;Qiu, Dong-Yuan;Zhang, Xiao-Hui;Li, Rui
    • Journal of Power Electronics
    • /
    • 제16권4호
    • /
    • pp.1407-1414
    • /
    • 2016
  • Unlike existing pulse-width modulation (PWM) techniques, such as sinusoidal PWM and random PWM, the wavelet PWM (WPWM) technique based on a Harr wavelet function can achieve a high fundamental component for the output voltage, low total harmonic distortion, and simple digital implementation. However, the original WPWM method lacks output voltage control. Thus, the practical application of the WPWM technique is limited. This study proposes an improved WPWM technique that can regulate output voltage amplitude with the addition of a parameter. The relationship between the additional parameter and the output voltage amplitude is analyzed in detail. Experimental results verify that the improved WPWM exhibits output voltage control in addition to all the merits of the WPWM technique.

고속전철용 디스크-패드 브레이크의 동적거동 특성에 관한 유한요소해석 (Finite Element Analysis on the Dynamic Behaviors of a Disk-Pad Brake in High-Speed Trains)

  • 김청균;조승현
    • Tribology and Lubricants
    • /
    • 제16권2호
    • /
    • pp.99-105
    • /
    • 2000
  • Using a coupled thermal-mechanical analysis, the dynamic distortion of the ventilated disk brakes has been presented for a high-speed train. The offset ratio between the maximum and minimum values of the thermal distortions has been analyzed as a function of a braking number. The computed FEM results show that the offset ratios in radial direction are much greater than those of circumferentially distorted components. This means that the axial distortions in radial direction may dominantly produce thermally caused wears and cracks at the rubbing surfaces.

고조파 저감을 위한 단상 3-레벨 PWM 인버터 (Single-Phase 3-level PWM Inverter for Harmonics Reduction)

  • 강필순;박성준;김철우
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권3호
    • /
    • pp.125-132
    • /
    • 2002
  • This paper presents a single-phase 3-level PWM inverter to alleviate the harmonic components of output voltage and current under the conditions of identical supply DC voltage and switching frequency to the conventional inverter. Operational principles and analysis are performed, and the switching functions are derived. Deadbeat controller is also designed and implemented for the inverter to keep the output voltage being sinusoidal and to have the high dynamic performances even in the cases of load variations and the partial magnetization of filter inductor. The validity of proposed inverter is proved from the simulated and experimented results.

고속전철용 디스크 브레이크의 동적거동 특성에 관한 연구 (A Study on the Dynamic Behaviors of a Disk Brake for a High-Speed Train)

  • 조승현;김청균
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1999년도 제30회 추계학술대회
    • /
    • pp.276-282
    • /
    • 1999
  • Using a coupled thermal-mechanical analysis, the dynamic distortion of the ventilated disk brakes has been presented for a high-speed train. The offset ratio between the maximum and minimum values of the thermal distortions has been analyzed as a function of a braking number. The computed FEM results show that the offset ratios in radial direction are much greater than those of circumferentially distorted components. This means that the axial distortions in radial direction may dominantly produce thermally caused wears and cracks at the rubbing surfaces.

  • PDF

저왜율을 갖는 2상정현파 전압제어 발진기에 관한 연구 (A Study on the two phase sinusoidal voltage Controlled Oscillator with Low Distortion)

  • 이성백;이윤종
    • 한국통신학회논문지
    • /
    • 제12권5호
    • /
    • pp.527-534
    • /
    • 1987
  • 진동에 관한 비선형 1계연립미분방정식을 아나로그 시뮬레이션으로 2상전압제어발진을 시켜 유용성을 확인하였다. 2상신호를 각각 제곱하여 합성하는 부분과 곱셈부분의 실제회로 구성시 복잡하고 가격이 높아지므로 정류 회로와 스위칭회로로 대치하여 회로의 단순화와 가격 저렴화를 이루었다. 본 논문에서 제시된 회로는 제어 압력전압에 주파수가 정확한 비례관계를 가졌고, 응답 속도가 비교적 빠르고 또한 위상오차가 매우 적었으며 주파수비가 10:1 이상에서도 저왜율과 정진폭으로 동작하였다.

  • PDF

대용량 인버터 시스템을 위한 공간벡터 PWM 인버터의 병렬 운전 (Parallel Operation of Space Vector PWM Inverters for Large Capacity Inverter System)

  • 지준근;이현동
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제49권8호
    • /
    • pp.509-513
    • /
    • 2000
  • This paper deals with the parallel operation of space vector PWM for large capacity inverter system. To enlarge the capacity of inverter system and to reduce the current ripples on inverter output side, two or more inverters are operated in parallel. In this paper, a new parallel operation strategy which minimizes the harmonic distortion of the output stage is described. The proposed method is developed on the basis of the space-vector PWM in order to increase the linearly controllable voltage range. With the help of the proposed voltage synthesis method, the total harmonic distortion of the output stage can be greatly reduced in compared with that of conventional method with sinusoidal PWM or that of the single inverter operation case. The experimental results with reduced scale test show the feasibility of the proposed voltage synthesis method.

  • PDF

변전소 고조파 측정 및 분석에 관한 연구 (A Study on Measurement and Analysis of Harmonics in Substation)

  • 한무호;박태준;이성희;이치환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.438-441
    • /
    • 2001
  • Nonlinear loads change the sinusoidal nature of the ac power current, thereby resulting in the flow of harmonic currents in the ac power system that can cause interference with communication circuits and other type of equipment. To minimize the damage, it is needed to limit harmonics current and voltage. Harmonic measurement system was developed to measure individual voltage and current harmonic continuously and save harmonic data on computer. We measured all 154kV feeders in a steel making company substation. Voltage and current distortion limits for general transmission systems was suggested We found some feeders exceeded current distortion limits. As result voltage harmonic exceeded standard limits.

  • PDF