• 제목/요약/키워드: sink system

검색결과 436건 처리시간 0.03초

팬싱크의 유동 특성에 관한 실험 및 수치해석적 연구 (Experimental and Numerical Studies on the Flow Characteristics of a Fan-Sink)

  • 이경용;최영석;윤재호
    • 설비공학논문집
    • /
    • 제18권3호
    • /
    • pp.225-230
    • /
    • 2006
  • The overall performance and local flow fields of the fan, heat sink, and fan-sink were experimentally and numerically studied to investigate the flow characteristics of a fan-sink. The flow resistance of the heat sink was measured by small fan tester based on AMCA standards and compared with the CFD results to select available cooling fan for the fan-sink. The nonuniform velocity profile behind the fan outlet was shown by the flow visualization. The effects of nonuniform velocities on the performance of heat sink were discussed. To validate the commercial CFD code CFX-5.6, the predicted performance curve was compared with that of fan testing. The local flow fields of the fan-sink were analyzed by CFD results. MFR (multiple frame of reference) was used as a computational model combining rotating fan and stationary heat sink. Through the CFD results of the fan-sink, the flow patterns behind the fan outlet influenced the flow resistance and overall performance of the heat sink.

펠티에 소자 및 히트싱크를 이용한 최적 냉각성능에 관한 연구 (Investigation of the Optimal Cooling Performance Using Peltier Module and Heat Sink)

  • 이동렬
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.65-70
    • /
    • 2006
  • This study is to experimentally evaluate the cooling performance of the Bonding type and Injection type of heat sink using three different kinds of industrial Peltier module by digital LabViewTM measurement. Injection type of heat sink could be more efficient for the heat transfer than Bonding type, even with 30% more radiating surface area. In addition, the experimental results revealed that the sufficient power supplied was able to show the better cooling performance of Peltier module. In order to verify the optimal cooling performance of the cooling device, two Peltier module, HMN 6040 and HMN 1550 with Bonding and Injection type of heat sink were used. The cooling performance with injection type of heat sink was 2.11% and 6.24% better than that with bonding type of heat sink under the HMN 6040 and HMN 1550, respectively.

  • PDF

히트 싱크 부착 전자부품을 가진 통신시스템의 냉각성능 연구 (Cooling performance of an electronic system including electronic components mounted with heat sink)

  • 노홍구;이재헌
    • 대한기계학회논문집B
    • /
    • 제22권2호
    • /
    • pp.253-266
    • /
    • 1998
  • A numerical study on the cooling performance for electronic components mounted with heat sink in an electronic system has been performed. The model of electronic system consisted with lower and upper modules in which the electronic components mounted with heat sink were arrayed. To find better configuration under a given fan power for effective cooling, the cases called 'No heat sink','Both heat sinks','Lower heat sinks', and 'Upper heat sinks' were tested. The results showed that the cooling performance in 'Upper heat sinks' was the best among four cases.

연속 n중 k의 고장 연결 시스템에 있어서 최적 Redundancy 설계 (Optimal Redundancy of the Consecutive k out of n Failure Lines Included or Excluded Sink-Source Parts.)

  • Bok-Man, Kim;Chung-Hwan, Oh
    • 산업경영시스템학회지
    • /
    • 제17권30호
    • /
    • pp.209-214
    • /
    • 1994
  • A consecutive k out of n failure lines with sink-source parts is a system of components in sequence such that the system fails whether some k consecutive components are all fail. Some object, be it a flow, is to be relayed from a source to a sink through a sequence of intermediate stations(components). Now care should be taken as to if the source and the sink are also considered components of the systems, i. e. , whether they serve the same function as the intermediate components (stations). Such systems are different from ordinary consecutive k- out of n failure lines by adding the on source and sink pole[6]. The main properties of the reliability by the optimal redundancy of consecutive k out of n failure lines are presented under this modification.

  • PDF

센서 네트워크에서 이동싱크로의 연결설정 방안 (A Connection Setup Scheme to Mobile Sink in Sensor Networks)

  • 박상준;이종찬;김형종
    • 한국시뮬레이션학회논문지
    • /
    • 제17권1호
    • /
    • pp.9-16
    • /
    • 2008
  • 싱크의 이동성은 센서 네트워크에서 보다 많은 라우팅 변화를 발생시킨다. 능동적인 싱크의 이동으로 필요한 정보에 대한 적극적인 수집이 가능할 것이며, 이는 네트워크의 효용성을 더욱 높일 것이다. 하지만 고정된 싱크와 달리 싱크가 이동성을 가지게 되면 센서 노드와의 통신 연결이 지속적으로 변경될 수 있다. 라우팅 변동에 의한 경로 재설정이 불가피하게 되는 것이다. 이동 싱크로의 경로 설정에는 싱크에서 노드로의 경로 설정과 노드에서 이동 싱크로의 경로 설정 두 가지가 있다. 센서 네트워크에서 노드는 많은 제약을 가지고 있다. 노드에서 싱크로의 연결 설정을 발생할 경우 경로 배정에 대한 부담을 줄이는 방안이 제시되어야 한다. 따라서 본 논문에서는 노드에서 이동 싱크로의 경로 설정을 위한 에이전트 방식을 제안한다. 에이전트 방식은 중계 노드를 통하여 경로 설정이 필요한 노드와 이동 싱크와의 신속한 연결 방안을 제공한다.

  • PDF

히트싱크의 핀 배열에 따른 냉각특성에 관한 실험적 연구 (An Experimental Study on Cooling Characteristic according to Fin Array of Aluminum Heat Sink)

  • 윤성운;김재열;고가진
    • 한국기계가공학회지
    • /
    • 제17권1호
    • /
    • pp.138-143
    • /
    • 2018
  • In general, the operating temperature of electronic equipment is closely related to product life and reliability, and it is recognized that effectively cooling the parts is an important problem. In this paper, an experimental study on the cooling characteristic according to the pin array of the heat sink is conducted. The experiment on the heat sink was based on the natural convection and temperature distribution changes. The experimental results indicate that the pin array of the heat sink has an effect on the thermoelectric module's cooling characteristic.

냉열원 온도 변화에 따른 다단재열랭킨사이클의 성능해석 (The Performance Analysis of Multi Stage Reheater Organic Rankine Cycle According to Heat Sink Temperature Change)

  • 이호생;임승택;김현주
    • 동력기계공학회지
    • /
    • 제20권1호
    • /
    • pp.11-17
    • /
    • 2016
  • In this study, the simulation for performance comparison between basic single stage organic rankine cycle, multi stage reheater cycle and multi stage reheater & recuperator cycle was carried out. The multi stage reheater cycle and multi stage reheater & recuperator cycle was designed to improve the efficiency for organic rankine cycle using heat source from industrial waste heat and heat sink from deep ocean water. R245fa was selected as a refrigerant for the cycle and system efficiencies were simulated by the variation of the heat sink temperature and the cycle classification. Performance characteristics were simulated by using the Aspen HYSYS. It was confirmed that the system efficiency was decreased by the increase of heat sink temperature. These results can be considered to be applied as geo-ocean thermal energy conversion in where plenty of geothermal or ocean thermal resource exist.

LED 프로젝터 방열용 히트싱크의 성능평가 (Performance Evaluation of Heat Sink for Cooling of LED Projector)

  • 이경용;최영석;전동순;김선창;손광은
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1167-1171
    • /
    • 2008
  • The flow and thermal performance of the skiving and louver fin type heat sinks for the cooling system of the small LED projector were experimentally evaluated. A small fan tester based on AMCA standards was used to control and measure the air flow rate into the heat sink. Three heat blocks were used to simulate the heat and light sources(red, green and blue) of the small LED projector. We measured the pressure drop, temperatures and input power at the specific air flow rate and discussed those results. As a result, it is found that the louver fin type heat sink has higher pressure drop and lower thermal resistance than the skiving type. From the comparison of the temperature of the heat block between skiving and louver fin type, the louver fin type heat sink was found to be more suitable for cooling the high power heat source than skiving type. The thermal performance of the fan-sink(louver fin type) system was discussed with the picture taken by a thermal video.

  • PDF

승용 전조등 LED 램프의 방열판 자연 냉각특성 (Natural Cooling Characteristics of a Heat Sink for LED Headlight used in Passenger Cars)

  • 유재용;박설현
    • 한국기계가공학회지
    • /
    • 제16권2호
    • /
    • pp.142-148
    • /
    • 2017
  • The objective of this study is to investigate the cooling characteristics of a heat sink for an LED headlight used in passenger cars. To this end, this study conducts the experimental and numerical analysis of the heat sink heated at constant heat fluxes without air flow applied. In the experiments, heat was transferred at a constant heat flux through the bottom of a heat sink. The measured temperature on pre-selected locations of the heat sink was in good agreement with the numerically predicted one. The experimental and numerical results indicate that the convective heat transfer coefficient for the natural convection mode was decreased by increasing the heat flux applied to the bottom of heat sink, lowering the cooling capabilities.

아연-0.2%알루미늄합금 용융도금액 중에서 용사층의 내구성에 관한 연구 (A Study on Durability of Sprayed Coating Layer in the Molten Zn-0.2% Al Alloy Bath)

  • 강태영;임병문;최장현;김영식
    • Journal of Welding and Joining
    • /
    • 제19권5호
    • /
    • pp.512-519
    • /
    • 2001
  • Sink roll has been used in molten Zn-0.2%Al alloy bath of continuous galvanizing line in sinking and stabilizing process of the steel strip in molten metal bath. In this process, although the scraper scraps off the sink roll surface, the dross compounds is builded up on the sink roll surface and the life time of the sink roll is shorten by the dross compounds. The present study was investigated the application of the spray coating layer on sink roll body for improving durability In molten Zn-0.2%Al alloy. Through the durability tests in molten Zn-0.2%Al alloy with various ceramic and cermet coating layer, the optimum bond and top coating material was obtained. As the results, the system of STS430F base metal, WC-l7Co bond and $ZrO_2-SiO_2$ top coating was clarified to be the best quality of durability in molten Zn-0.2%Al alloy.

  • PDF