Single-Stage High Power Factor Two-Switch Forward Converter (단일전력단 고역률 Two-Switch Forward 컨버터)

  • Bae, Jin-Yong;Kim, Yong;Cho, Kyu-Man;Lee, Eun-Young;Lee, Kyu-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.247-250
    • /
    • 2006
  • This paper presents the single-stage High Power Factor TSFC(Two-Switch Forward Converter). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contents of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output. The principle of operation, feature and design considerations are illustrated and verified through the experiment with a 200W(5V, 40A) 200kHz MOSFET based experimental circuit.

  • PDF

Single-Stage High Power Factor AC/DC Two-Switch Forward Converter (단일전력단 고역률 AC/DC Two-Switch Forward 컨버터)

  • Bae, Jin-Yong;Kim, Yong;Kwon, Soon-Do;Lee, Kyu-Hoon;Gye, Sang-Bum
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.169-172
    • /
    • 2006
  • This paper presents the single-stage High Power Factor AC/DC Two-Switch Forward Converter (TSFC). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contents of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output. The principle of operation, feature and design considerations are illustrated and verified through the simulation with a 200W(5V, 40A) 200kHz MOSFET based experimental circuit.

  • PDF

A Study on PFC of Active Clamp ZVS Flyback Converter

  • Choi Tae-Young;Ahn Jeong-Joon;Ryu Dong-Kyun;Lee Woo-Suk;Won Chung-Yuen;Kim Soo-Seok
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.611-616
    • /
    • 2001
  • This paper analyzed PFC of active clamp ZVS flyback converter by adding two methods PFC (power Factor Correction) circuit - two-stage and single-stage. The addition of active clamp circuit also provides a mechanism for achieving ZVS of both the primary and auxiliary switches. ZVS also limits the turn off di/dt of the output rectifier, reducing rectifier-switching loss and switching noise, due to diode reverse recovery. As a result, the proposed converters have characteristics of the reduced switching noise and high efficiency in comparison to conventional flyback converter. The simulation and experimental results show that the proposed converter improve the input PF of 300W ZVS flyback converter by adding single-stage, two-stage PFC circuit.

  • PDF

Single-Stage High Power Factor TTFC(Two-Transistor Forward Converter) (단일전력단 고역률 TTFC(Two-Transistor Forward Converter))

  • Bae, Jin-Yong;Kim, Yong;Kim, Pill-Soo;Lee, Eun-Young;Kwon, Soon-Do
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.226-228
    • /
    • 2005
  • This paper presents the single-stage High Power Factor TTFC(Two-Transistor Forward Converter). Recently, due to growing concern about the harmonic pollution of power distribution systems and the adoption of standards such as ICE 61000-3-2 and IEEE 519, There is a need to reduce the harmonic contests of AC line currents of power supplies. This research proposed the single-stage two switch forward circuit for low voltage and high current output.

  • PDF

New MPPT Control Strategy for Two-Stage Grid-Connected Photovoltaic Power Conditioning System

  • Bae, Hyun-Su;Park, Joung-Hu;Cho, Bo-Hyung;Yu, Gwon-Jong
    • Journal of Power Electronics
    • /
    • v.7 no.2
    • /
    • pp.174-180
    • /
    • 2007
  • In this paper, a simple control method for two-stage utility grid-connected photovoltaic power conditioning systems (PCS) is proposed. This approach enables maximum power point (MPP) tracking control with post-stage inverter current information instead of calculating solar array power, which significantly simplifies the controller and the sensor. Furthermore, there is no feedback loop in the pre-stage converter to control the solar array voltage or current because the MPP tracker drives the converter switch duty cycle. This simple PCS control strategy can reduce the cost and size, and can be utilized with a low cost digital processor. For verification of the proposed control strategy, a 2.5kW two-stage photovoltaic grid-connected PCS hardware which consists of a boost converter cascaded with a single-phase inverter was built and tested.

The Optimal Ordering Policy for the Generalized Two-Stage Inventory System (일반화된 2단계 재고체계에서의 최적주문정책)

  • 정남기;차동원
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.4 no.1
    • /
    • pp.25-31
    • /
    • 1979
  • We consider the optimal ordering policy for a single-product two-stage inventory system where the main assumptions are as follows: (i) constant continuous demand only at stage 2, (ii) constant input (production) rate at stage 1, (iii) instantaneous delivery (transportation) from stage 1 to stage 2, (iv) backlogging is allowed only at stage 2, (v) an infinite planning horizon. Costs considered are ordering and linear holding costs at both stages, and linear shortage cost only at stages 2. By solving 9 different case problems, we have observed the general from of the optimal ordering policies for our model which minimizes the total cost per unit time. It is noticeable from this observation that the questionable but more often than not adopted assumption by many authors in determining the optimal potimal policy for multistage inventory systems, that the ordering (lot) sizes at each stage remain constant thruout the planning horizon, is not valid.

  • PDF

New CCM Single Stage PFC Full Bridge Converter (새로운 CCM 단일 전력단 역률보상 풀 브리지 컨버터)

  • Lim, Chang-Seob;Kwon, Soon-Kurl;Cho, Jung-Goo;Song, Doo-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.986-989
    • /
    • 2002
  • This paper proposes a new single stage power factor correction (PFC) full bridge converter which operates at continuous conduction mode(CCM). The proposed single stage PFC consists of typical zero voltage switching(ZVS) full bridge DC/DC converter, two transformer auxiliary windings, and two small inductors, and two diodes. Neither additional active switch nor any control circuit are added for PFC resulting in very low cost. The proposed converter provides input power factor correction with CCM control and tight output voltage regulation. All switching devices are operated under ZVS with minimum voltage stress. Operation principle and analysis are explained and verified with computer simulation and experimental results on a 1.2kW, 100kHz prototype.

  • PDF

A Comparative Study of Simple Ac-Dc PWM Full-Bridge Current-Fed and Voltage-Fed Converters

  • Moschopoulos Gerry;Shah Jayesh
    • Journal of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.246-255
    • /
    • 2004
  • Ac-dc PWM single-stage converters that integrate the PFC and dc-dc conversion functions in a single switching converter have been proposed to try to minimize the cost and complexity associated with implementing two separate and independent switch-mode converters. In this paper, two simple ac-dc single-stage PWM full-bridge converters are considered - one current-fed, the other voltage-fed. The operation of both converters is explained and their properties are noted. Experimental results obtained from simple lab prototypes of both converters are presented, then compared and discussed.

New Single Stage PFC Full Bridge Converter (새로운 단일전력단 역률보상 풀브리지 컨버터)

  • 임창섭;권순걸;조정구;송두익
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.655-660
    • /
    • 2003
  • This paper proposes new single stage power factor correction (PFC) full bridge converter. The proposed converter is combined previous ZVS full bridge DC/DC converter with two inductors, two diodes, two magnetic coupling transformer for PFC. This process of power is isolated from the source and also regulate stable DC output voltage in a category. In this topology, the voltage stress of main switches is reduced by zero voltage switching. Moreover, the proposed converter doesn't need active PFC switch and auxiliarly circuits, like control and gating board, so it could decrease the size and cost and increase the efficiency.

A Study on PFC of Active Clamp ZVS Flyback Converter (능동 클램프 ZVS 플라이백 컨버터의 역률개선에 관한 연구)

  • Choi T.Y.;Ahn J.J.;Ryu D.K.;Lee W.S.;Won C.Y.;Kim S.S.
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.538-541
    • /
    • 2001
  • This paper analyzed PFC of active clamp ZVS flyback converter by adding two method PFC (Power Factor Correction) circuit - Two-Stage and Single-Stage. It improves on Flyback converter's disadvantage - loss increasing by switching, noise increasing, high voltage stress of switch - by adding active clamp circuit. Simulation results show to improve the input PF of 300W ZVS flyback converter by adding Single-Stage, Two-Stage PFC circuit.

  • PDF