• 제목/요약/키워드: single pulse

검색결과 832건 처리시간 0.026초

복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구 (A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography)

  • 김정민;임태랑;석전유치;앵정달야
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제21권1호
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

균류 Coprinus cinereus에서 DNA 회복에 관여하는 RAD4 유사유전자의 분리와 특성 (Characterization of RAD4 Homologous Gene from Coprinus cinereus)

  • Choi, In-Soon
    • 생명과학회지
    • /
    • 제13권4호
    • /
    • pp.522-528
    • /
    • 2003
  • 본 연구는 출아형 효모 Saccharomyces cerevisiae에서 자외선의 상해 시 이를 정상으로 회복시키는 절제회복 (excision repair) 유전자로 알려진 RADA4의 특성 규명을 위하여 균류 Coprinus cinereus에서 이와 유사한 유전자를 분리하였다. RAD4 유사 유전자를 분리하기 위하여 균류 C. cinereus의 염색체 DNA를 전기영동하여 분리한 다음 효모 RAD4 DNA를 probe로하여 이와 hybridization하였다. 이 결과 RAD4 유사 유전자는 3.2 kb의 insert DNA를 갖고 있었다. 또한 Southern hybridization으로 이 유사 유전자는 fungus C. cinereus의 염색체에 존재함을 확인하였다. 분리한 RAD4 유사 유전자의 전사체 크기는 2.5 kb 였으며, 자외선의 상해 시 전혀 'inducibility가 없음을 Northern hybridization으로 확인하였다. 또한 유사유전자 부분을 삭제하였을 때 이 부분이 없는 세포는 전혀 생존을 못하였다. 이 결과 분리한 RAD4 유사유전자는 세포의 생존에 관여함을 알 수 있었다.

KTP 크리스탈을 이용한 PDT용 레이저 시스템 개발 (A Study on a KTP Crystal Laser System for a Cancer Using P.D.T.)

  • 김병문;남효덕;김병철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.631-634
    • /
    • 2004
  • The method that exists in Photodynamic Therapy uses Photosensibility drug strongly Influencing tumour accumulation together with photochemical laser effect and makes the structure of tumour be localized and become extinct. The intracavity transformation of the Nd :YAP main radiation 1079 nm was Raman converted in barium nitrate crystal and the Stokes frequency (1216 nm) was doubled using KTP or RTA crystals. The LiF or Cr:YAG crystals are used for the Q-switch. The radiation Parameters were obtained at 100 Hz pump repetition frequency. The average power at 608 nm radiation with LiF and KTP was 700 mW at multi-mode generation. The 3-6 single 10-15 ns pulses were generated during one cycle of pumping. The doubling efficiency with RTA was two times more than with KTP. The cells of Ehrlich adenocarcinoma (0.1 ml) were i.m. implanted in hind thighs of ICR white non-imbred mice. The cells were preliminarily diluted in medium 199 in the ratio of 1 to 5. HpD was intravenous administered in a dose of 10 mg/kg. The left clean-shaven hind leg was irradiated with laser light 21-27 hours after the administration of the preparation. The right non-Irradiated leg of each animal served as a control. The animals with the transplanted tumor that were not injected with HpD sewed as a control to estimate the complex effect (HpD+ irradiation). Before the administration of HpD and on 3 and 4 days after irradiation the tumor size was measured and the percent of the tumor growth inhibition was calculated. The results of animal treatments has shown high efficiency of PDT method for cancer treatment by means 0.608 m high power pulse solid state laser.

  • PDF

Electrical characteristics of SiC thin film charge trap memory with barrier engineered tunnel layer

  • Han, Dong-Seok;Lee, Dong-Uk;Lee, Hyo-Jun;Kim, Eun-Kyu;You, Hee-Wook;Cho, Won-Ju
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.255-255
    • /
    • 2010
  • Recently, nonvolatile memories (NVM) of various types have been researched to improve the electrical performance such as program/erase voltages, speed and retention times. Also, the charge trap memory is a strong candidate to realize the ultra dense 20-nm scale NVM. Furthermore, the high charge efficiency and the thermal stability of SiC nanocrystals NVM with single $SiO_2$ tunnel barrier have been reported. [1-2] In this study, the SiC charge trap NVM was fabricated and electrical properties were characterized. The 100-nm thick Poly-Si layer was deposited to confined source/drain region by using low-pressure chemical vapor deposition (LP-CVD). After etching and lithography process for fabricate the gate region, the $Si_3N_4/SiO_2/Si_3N_4$ (NON) and $SiO_2/Si_3N_4/SiO_2$ (ONO) barrier engineered tunnel layer were deposited by using LP-CVD. The equivalent oxide thickness of NON and ONO tunnel layer are 5.2 nm and 5.6 nm, respectively. By using ultra-high vacuum magnetron sputtering with base pressure 3x10-10 Torr, the 2-nm SiC and 20-nm $SiO_2$ were successively deposited on ONO and NON tunnel layers. Finally, after deposited 200-nm thick Al layer, the source, drain and gate areas were defined by using reactive-ion etching and photolithography. The lengths of squire gate are $2\;{\mu}m$, $5\;{\mu}m$ and $10\;{\mu}m$. The electrical properties of devices were measured by using a HP 4156A precision semiconductor parameter analyzer, E4980A LCR capacitor meter and an Agilent 81104A pulse pattern generator system. The electrical characteristics such as the memory effect, program/erase speeds, operation voltages, and retention time of SiC charge trap memory device with barrier engineered tunnel layer will be discussed.

  • PDF

Concrete pavement monitoring with PPP-BOTDA distributed strain and crack sensors

  • Bao, Yi;Tang, Fujian;Chen, Yizheng;Meng, Weina;Huang, Ying;Chen, Genda
    • Smart Structures and Systems
    • /
    • 제18권3호
    • /
    • pp.405-423
    • /
    • 2016
  • In this study, the feasibility of using telecommunication single-mode optical fiber (SMF) as a distributed fiber optic strain and crack sensor was evaluated in concrete pavement monitoring. Tensile tests on various sensors indicated that the $SMF-28e^+$ fiber revealed linear elastic behavior to rupture at approximately 26 N load and 2.6% strain. Six full-scale concrete panels were prepared and tested under truck and three-point loads to quantify the performance of sensors with pulse pre-pump Brillouin optical time domain analysis (PPP-BOTDA). The sensors were protected by precast mortar from brutal action during concrete casting. Once air-cured for 2 hours after initial setting, half a mortar cylinder of 12 mm in diameter ensured that the protected sensors remained functional during and after concrete casting. The strains measured from PPP-BOTDA with a sensitivity coefficient of $5.43{\times}10^{-5}GHz/{\mu}{\varepsilon}$ were validated locally by commercial fiber Bragg grating (FBG) sensors. Unlike the point FBG sensors, the distributed PPP-BOTDA sensors can be utilized to effectively locate multiple cracks. Depending on their layout, the distributed sensors can provide one- or two-dimensional strain fields in pavement panels. The width of both micro and major cracks can be linearly related to the peak strain directly measured with the distributed fiber optic sensor.

방기황기탕의 유전자 다형성에 따른 비만 치료 효과 : 무작위 배정, 이중 맹검, 위약-대조군 임상시험 (Impact of GNB3, ADRB3, UCP2, and PPAR${\gamma}$-Pro12Ala polymorphisms on Boiogito response in obese subjects : A randomized, double-blind, placebo-controlled trial)

  • 박정현;;임지연;김호준
    • 한방비만학회지
    • /
    • 제12권2호
    • /
    • pp.28-43
    • /
    • 2012
  • Objectives: The aim of the study was to investigate the efficacy of Boiogito for obesity. We examined the efficacy of Boiogito for obese patients and we expected the reaction of Boiogito would vary according to the single nucleotide polymorphism(SNPs). Methods: 111 subjects(body mass index${\geq}25m/kg^2$) were recruited and randomized to receive Boiogito(n=55) or Placebo(n=56) for 8weeks. Anthropometric factors, serum lipid profile, glucose, blood pressure(BP), pulse rate, resting metabolic rate and Korean version of obesity-related quality of life(KOQOL) scale measured at baseline and 8weeks. SNPs(${\beta}3$-adrenergic receptor(ADRB3), G protein ${\beta}3$(GNB3), peroxisome proliferator activated receptor gamma 2 gene(PPAR-${\gamma}2$), uncoupling protein(UCP2)) were conducted at baseline. Adverse reactions and safety outcome variables were also checked during trials. Results: Both groups showed significant improvement on obesity after treatment. Boiogito group decreased triglyceride than did control group and improved KOQOL. Boiogito showed a significant higher efficacy in C/T and T/T genotype of GNB3 gene / in Trp64 and Arg64 genotype of ADRB3 gene / in D/D genotype of UCP2 gene / in Pro/Pro genotype of PPAR-${\gamma}$ gene. Conclusions: Boiogito promoted obesity indexes without severe adverse reactions and proved its safety. Pharmacogenetical studies of Boiogito on obesity could be a effective method for the individualized treatment and prevention of obesity.

모드 잠금된 펄스 레이저와 연속 발진하는 반도체 레이저를 이용한 합주파수 생성 (Sum-frequency Generation Using a Mode-locked Pulsed Laser and a Continuous-wave Diode Laser)

  • 김현학;박남훈;염동일;차명식;문한섭
    • 한국광학회지
    • /
    • 제32권2호
    • /
    • pp.62-67
    • /
    • 2021
  • 본 연구에서는 모드 잠금된 ps-펄스 광섬유 레이저와 연속 발진하는 좁은 선폭의 반도체 레이저를 이용하여 주기적 분극반전된 LiNbO3(periodically poled lithium niobate; PPLN) 결정에서 합주파수 생성 연구를 수행하였다. 모드 잠금된 펄스 레이저는 중심 파장이 1560.7 nm이고 스펙트럼의 폭은 약 1.1 nm이며, 연속 발진 반도체 레이저는 중심 파장이 1551 nm이고 스펙트럼의 폭은 약 6 MHz로 동작한다. 합주파수 생성을 효과적으로 수행하기 위해서 하나의 단일 모드 광섬유를 이용하여 PPLN 결정 내부에서 두 펌프 광원을 공간적으로 완전히 중첩하였다. 모드 잠금된 펄스 레이저와 좁은 선폭의 연속발진 반도체 레이저에 의해서 모드 잠금된 펄스 형태의 778 nm인 합주파수 생성을 스펙트럼과 시간적인 변화로 확인하였다. 본 연구 결과는 주파수 제어가 가능한 광주파수 빗(optical frequency comb)을 이용한 광주파수 측정 및 고분해 레이저 분광 연구 등 다양하게 응용될 수 있을 것으로 기대된다.

Comparison of the anesthetic effects of 2,2,2-tribromoethanol on ICR mice derived from three different sources

  • Lee, Mi Ree;Suh, Hye Rin;Kim, Myeong Whan;Cho, Joon Young;Song, Hyun Keun;Jung, Young Suk;Hwang, Dae Youn;Kim, Kil Soo
    • Laboraroty Animal Research
    • /
    • 제34권4호
    • /
    • pp.270-278
    • /
    • 2018
  • This study was conducted to compare the anesthetic effects of 2,2,2-tribromoethanol (TBE, $Avertin^{(R)}$) in ICR mice obtained from three different sources. TBE (2.5%) was intraperitoneally injected at three doses: high-dose group (500 mg/kg), intermediate-dose group (250 mg/kg), and low-dose group (125 mg/kg). Anesthesia time, recovery time, end-tidal peak $CO_2$ ($ETCO_2$), mean arterial blood pressure, heart rate, oxygen saturation ($SpO_2$), body temperature, pH, $PCO_2$, and $PO_2$ of the arterial blood were measured. Stable anesthesia was induced by all doses of TBE and the anesthesia time was maintained exhibited dose dependency. No significant differences in anesthetic duration were found among the three different strains. However, the anesthesia time was longer in female than in male mice, and the duration of anesthesia was significantly longer in female than in male mice in the high-dose group. The recovery time was significantly longer for female than male mice in the intermediate- and high-dose groups. In the ICR strains tested, there were no significant differences in the mean arterial blood pressure, $SPO_2$, arterial blood $PCO_2$, and $PO_2$, which decreased after TBE anesthesia, or in heart rate and $ETCO_2$, which increased after TBE anesthesia. In addition, body temperature, blood biochemical markers, and histopathological changes of the liver, kidney, and lung were not significantly changed by TBE anesthesia. These results suggested that ICR mice from different sources exhibited similar overall responses to a single exposure to TBE anesthesia. In conclusion, TBE is a useful drug that can induce similar anesthetic effects in three different strains of ICR mice.

방전가공기의 효율적인 아크 검출과 제어방법 (Efficient Arc Detection and Control Method in Electro-discharge Machining)

  • 박양재
    • 디지털융복합연구
    • /
    • 제16권12호
    • /
    • pp.309-315
    • /
    • 2018
  • 방전 현상을 에너지로 이용하여 금속을 가공하는, 특히 초경 및 난삭 소재의 가공과 정밀가공에 효과적인 방전가공 시 빠른 가공속도와 향상된 정밀도 및 면조도를 달성하기 위하여 효율적인 아크의 검출과 제어방법에 대해 연구하였다. 단일 방전 파형을 Td(Time-Delay), Ton(Time-on), Toff(Time-off)의 세 가지 구간으로 나누어 HDL 언어를 이용하여 게이트 제어 타이밍을 시뮬레이션 하고, 실제 방전가공기에 적용하여 파형을 실측하였으며, 비교기 회로를 통한 Td 구간의 샘플링을 통해 서보기구의 동작을 결정함으로써 전극과 가공물 간의 간격 제어와 가공 결과에 미치는 영향을 분석하였다. 분석결과 형성되는 파형의 Td 구간을 보다 정밀하게 고속으로 샘플링하여 이를 토대로 전극과 가공물 간의 gap 제어에 적용하였을 때 보다 향상된 결과를 나타내었다.

A Case of Renal Cortical Necrosis in a 15-year-old Boy with Acute Kidney Injury

  • Lee, Mi-ji;Yim, Hyung Eun;Yoo, Kee Hwan
    • Childhood Kidney Diseases
    • /
    • 제23권1호
    • /
    • pp.53-57
    • /
    • 2019
  • Renal cortical necrosis (RCN) is patchy or diffuse ischemic destruction of the renal cortex caused by significantly reduced renal arterial perfusion. It is a rare cause of acute kidney injury (AKI) and is associated with high mortality. Here, we review the case of RCN in a 15-year-old boy who developed AKI. A 15-year-old boy was referred to our hospital from a local hospital due to a sharp decrease in his renal function. He presented with acute flank pain, nausea with vomiting, and oliguria for the past two days. He had taken a single dose of antihistamine for nasal congestion. At our hospital, his peak blood pressure was 148/83 mmHg and he had a high body mass index of $32.9kg/m^2$. The laboratory data showed a blood urea nitrogen (BUN) of 28.4 mg/dL, a creatinine of 4.26 mg/dL, and a glomerular filtration rate estimated from the serum cystatin C of $20.2mL/min/1.73m^2$. Proteinuria (spot urine protein to creatinine ratio 1.66) with pyuria was observed. Kidney sonography showed parenchymal swelling and increased renal echogenicity. Due to rapidly progressing nephritis, steroid pulse therapy (750 mg/IV) was done on the second day of his admission and the patient showed complete recovery with normal renal function. However, the kidney biopsy findings revealed renal cortical hemorrhagic necrosis. Multifocal, relatively well-circumscribed, hemorrhagic necrotic areas (about 25%) were detected in the tubulointerstitium. Although RCN is an unusual cause of AKI, especially in children, pediatricians should consider the possibility of RCN when evaluating patients with rapidly decreasing renal function.