• Title/Summary/Keyword: single pulse

Search Result 828, Processing Time 0.025 seconds

Concrete pavement monitoring with PPP-BOTDA distributed strain and crack sensors

  • Bao, Yi;Tang, Fujian;Chen, Yizheng;Meng, Weina;Huang, Ying;Chen, Genda
    • Smart Structures and Systems
    • /
    • v.18 no.3
    • /
    • pp.405-423
    • /
    • 2016
  • In this study, the feasibility of using telecommunication single-mode optical fiber (SMF) as a distributed fiber optic strain and crack sensor was evaluated in concrete pavement monitoring. Tensile tests on various sensors indicated that the $SMF-28e^+$ fiber revealed linear elastic behavior to rupture at approximately 26 N load and 2.6% strain. Six full-scale concrete panels were prepared and tested under truck and three-point loads to quantify the performance of sensors with pulse pre-pump Brillouin optical time domain analysis (PPP-BOTDA). The sensors were protected by precast mortar from brutal action during concrete casting. Once air-cured for 2 hours after initial setting, half a mortar cylinder of 12 mm in diameter ensured that the protected sensors remained functional during and after concrete casting. The strains measured from PPP-BOTDA with a sensitivity coefficient of $5.43{\times}10^{-5}GHz/{\mu}{\varepsilon}$ were validated locally by commercial fiber Bragg grating (FBG) sensors. Unlike the point FBG sensors, the distributed PPP-BOTDA sensors can be utilized to effectively locate multiple cracks. Depending on their layout, the distributed sensors can provide one- or two-dimensional strain fields in pavement panels. The width of both micro and major cracks can be linearly related to the peak strain directly measured with the distributed fiber optic sensor.

Impact of GNB3, ADRB3, UCP2, and PPAR${\gamma}$-Pro12Ala polymorphisms on Boiogito response in obese subjects : A randomized, double-blind, placebo-controlled trial (방기황기탕의 유전자 다형성에 따른 비만 치료 효과 : 무작위 배정, 이중 맹검, 위약-대조군 임상시험)

  • Park, Jung-Hyun;Bose, Shambhunath;Lim, Chi-Yeon;Kim, Ho-Jun
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.12 no.2
    • /
    • pp.28-43
    • /
    • 2012
  • Objectives: The aim of the study was to investigate the efficacy of Boiogito for obesity. We examined the efficacy of Boiogito for obese patients and we expected the reaction of Boiogito would vary according to the single nucleotide polymorphism(SNPs). Methods: 111 subjects(body mass index${\geq}25m/kg^2$) were recruited and randomized to receive Boiogito(n=55) or Placebo(n=56) for 8weeks. Anthropometric factors, serum lipid profile, glucose, blood pressure(BP), pulse rate, resting metabolic rate and Korean version of obesity-related quality of life(KOQOL) scale measured at baseline and 8weeks. SNPs(${\beta}3$-adrenergic receptor(ADRB3), G protein ${\beta}3$(GNB3), peroxisome proliferator activated receptor gamma 2 gene(PPAR-${\gamma}2$), uncoupling protein(UCP2)) were conducted at baseline. Adverse reactions and safety outcome variables were also checked during trials. Results: Both groups showed significant improvement on obesity after treatment. Boiogito group decreased triglyceride than did control group and improved KOQOL. Boiogito showed a significant higher efficacy in C/T and T/T genotype of GNB3 gene / in Trp64 and Arg64 genotype of ADRB3 gene / in D/D genotype of UCP2 gene / in Pro/Pro genotype of PPAR-${\gamma}$ gene. Conclusions: Boiogito promoted obesity indexes without severe adverse reactions and proved its safety. Pharmacogenetical studies of Boiogito on obesity could be a effective method for the individualized treatment and prevention of obesity.

Sum-frequency Generation Using a Mode-locked Pulsed Laser and a Continuous-wave Diode Laser (모드 잠금된 펄스 레이저와 연속 발진하는 반도체 레이저를 이용한 합주파수 생성)

  • Kim, Hyunhak;Park, Nam Hun;Yeom, Dong-Il;Cha, Myoungsik;Moon, Han Seb
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.2
    • /
    • pp.62-67
    • /
    • 2021
  • We have experimentally demonstrated sum-frequency generation (SFG) in a periodically poled lithium niobate (PPLN) crystal, using a mode-locked picosecond-pulsed fiber laser and a continuous-wave (CW) diode laser with a narrow linewidth. The mode-locked fiber laser had a center wavelength of 1560.7 nm and a spectral width of 1.1 nm, and the CW diode laser had a center wavelength of 1551.0 nm and a spectral width of 6 MHz. To effectively realize SFG, both of the spatial modes of the two lasers were made to overlap in the PPLN crystal by using a single-mode optical fiber. The pulse-mode SFG with pulsed- and CW-mode lasers was successfully observed in the spectral and time domains. These results are expected to be applicable in various ways, such as optical frequency measurement and high-resolution laser spectroscopy studies using optical frequency combs.

Comparison of the anesthetic effects of 2,2,2-tribromoethanol on ICR mice derived from three different sources

  • Lee, Mi Ree;Suh, Hye Rin;Kim, Myeong Whan;Cho, Joon Young;Song, Hyun Keun;Jung, Young Suk;Hwang, Dae Youn;Kim, Kil Soo
    • Laboraroty Animal Research
    • /
    • v.34 no.4
    • /
    • pp.270-278
    • /
    • 2018
  • This study was conducted to compare the anesthetic effects of 2,2,2-tribromoethanol (TBE, $Avertin^{(R)}$) in ICR mice obtained from three different sources. TBE (2.5%) was intraperitoneally injected at three doses: high-dose group (500 mg/kg), intermediate-dose group (250 mg/kg), and low-dose group (125 mg/kg). Anesthesia time, recovery time, end-tidal peak $CO_2$ ($ETCO_2$), mean arterial blood pressure, heart rate, oxygen saturation ($SpO_2$), body temperature, pH, $PCO_2$, and $PO_2$ of the arterial blood were measured. Stable anesthesia was induced by all doses of TBE and the anesthesia time was maintained exhibited dose dependency. No significant differences in anesthetic duration were found among the three different strains. However, the anesthesia time was longer in female than in male mice, and the duration of anesthesia was significantly longer in female than in male mice in the high-dose group. The recovery time was significantly longer for female than male mice in the intermediate- and high-dose groups. In the ICR strains tested, there were no significant differences in the mean arterial blood pressure, $SPO_2$, arterial blood $PCO_2$, and $PO_2$, which decreased after TBE anesthesia, or in heart rate and $ETCO_2$, which increased after TBE anesthesia. In addition, body temperature, blood biochemical markers, and histopathological changes of the liver, kidney, and lung were not significantly changed by TBE anesthesia. These results suggested that ICR mice from different sources exhibited similar overall responses to a single exposure to TBE anesthesia. In conclusion, TBE is a useful drug that can induce similar anesthetic effects in three different strains of ICR mice.

Efficient Arc Detection and Control Method in Electro-discharge Machining (방전가공기의 효율적인 아크 검출과 제어방법)

  • Park, Yang-Jae
    • Journal of Digital Convergence
    • /
    • v.16 no.12
    • /
    • pp.309-315
    • /
    • 2018
  • In this paper, propose an efficient arc detection and control method to achieve fast machining speed, improved precision and surface roughness in discharge machining, especially for carbide and hard material processing and metal processing using discharge phenomenon as energy. A single discharge waveform is divided into three sections of Td (Time-Delay), Ton (Time-on) and Toff (Time-off) and the gate control timing is simulated using the HDL language. In this paper, we analyze the effect of the gap between the electrode and the workpiece on the machining results by determining the operation of the servo mechanism by sampling the Td section through the comparator circuit. As a result of the analysis, the Td section of the formed waveform was more precisely sampled at a high speed and the results were improved when applied to the gap control between the electrode and the workpiece.

A Case of Renal Cortical Necrosis in a 15-year-old Boy with Acute Kidney Injury

  • Lee, Mi-ji;Yim, Hyung Eun;Yoo, Kee Hwan
    • Childhood Kidney Diseases
    • /
    • v.23 no.1
    • /
    • pp.53-57
    • /
    • 2019
  • Renal cortical necrosis (RCN) is patchy or diffuse ischemic destruction of the renal cortex caused by significantly reduced renal arterial perfusion. It is a rare cause of acute kidney injury (AKI) and is associated with high mortality. Here, we review the case of RCN in a 15-year-old boy who developed AKI. A 15-year-old boy was referred to our hospital from a local hospital due to a sharp decrease in his renal function. He presented with acute flank pain, nausea with vomiting, and oliguria for the past two days. He had taken a single dose of antihistamine for nasal congestion. At our hospital, his peak blood pressure was 148/83 mmHg and he had a high body mass index of $32.9kg/m^2$. The laboratory data showed a blood urea nitrogen (BUN) of 28.4 mg/dL, a creatinine of 4.26 mg/dL, and a glomerular filtration rate estimated from the serum cystatin C of $20.2mL/min/1.73m^2$. Proteinuria (spot urine protein to creatinine ratio 1.66) with pyuria was observed. Kidney sonography showed parenchymal swelling and increased renal echogenicity. Due to rapidly progressing nephritis, steroid pulse therapy (750 mg/IV) was done on the second day of his admission and the patient showed complete recovery with normal renal function. However, the kidney biopsy findings revealed renal cortical hemorrhagic necrosis. Multifocal, relatively well-circumscribed, hemorrhagic necrotic areas (about 25%) were detected in the tubulointerstitium. Although RCN is an unusual cause of AKI, especially in children, pediatricians should consider the possibility of RCN when evaluating patients with rapidly decreasing renal function.

Adaptive Pressure Sensor with High Sensitivity and Large Bandwidth Based on Gallium Microdroplet-elastomer Composite (갈륨 미세입자 탄성 복합체 기반 고민감도와 광대역폭을 갖는 가변 강성 압력센서)

  • Simok, Lee;Sang-Hyuk, Byun;Steve, Park;Joo Yong, Sim;Jae-Woong, Jeong
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.6
    • /
    • pp.423-427
    • /
    • 2022
  • A pressure sensor that mimics the sensing ability of human skin has emerged as high-profile technology because it shows remarkable applications in numerous fields such as robotics, human health monitoring, and artificial prosthetics. Whereas recent pressure sensors have achieved high sensitivity similar to that of human skin, they still show limited detection bandwidth. Moreover, once these e-skin are fabricated, their sensitivity and stiffness are fixed; therefore, they can be used for only limited applications. Our study proposes a new adaptive pressure sensor built with uniform gallium microdroplet-elastomer composite. Based on the phase transition of gallium microdroplets, the proposed sensor undergoes mode transformation, enabling it to have a higher sensitivity and wider detection bandwidth compared with those of human skin. In addition, we succeeded in extending a single adaptive pressure sensor to sensor arrays based on its high uniformity, reproducibility, and large-scale manufacturability. Finally, we designed an adaptive e-skin with the sensor array and demonstrated its applications on health monitoring tasks including blood pulse and body weight measurements.

Feasibility study of CdZnTe and CdZnTeSe based high energy X-ray detector using linear accelerator

  • Beomjun Park;Juyoung Ko;Jangwon Byun;Byungdo Park ;Man-Jong Lee ;Jeongho Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2797-2801
    • /
    • 2023
  • CdZnTeSe (CZTS) has attracted attention for applications in X- and gamma-ray detectors owing to its improved properties compared to those of CdZnTe (CZT). In this study, we grew and processed single crystals of CZT and CZTS using the Bridgeman method to confirm the feasibility of using a dosimeter for high-energy X-rays in radiotherapy. We evaluated their linearity and precision using the coefficient of determination (R2) and relative standard deviation (RSD). CZTS showed sufficient RSD values lower than 1.5% of the standard for X-ray dosimetry, whereas CZT's RSD values increased dramatically under some conditions. CZTS exhibited an R2 value of 0.9968 at 500 V/cm, whereas CZT has an R2 value of 0.9373 under the same conditions. The X-ray response of CZTS maintains its pulse shape at various dose rates, and its properties are improved by adding selenium to the CdTe matrix to lower the defect density and sub-grain boundaries. Thus, we validated that CZTS shows a better response than CZT to high-energy X-rays used for radiotherapy. Further, the applicability of an onboard imager, a high-energy X-ray (>6 MV) image, is presented. The proposed methodology and results can guide future advances in X-ray dose detection.

Effects of an Aromatherapy Education Program on Stress, Self-efficacy, and Autonomic Nervous System Function of Female College Students Preparing for Employment (아로마테라피 교육 프로그램이 취업준비 여대생의 스트레스와 자기효능감 및 자율신경계에 미치는 영향)

  • Eun-Joo Lee;Eun-Jin Lim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.3
    • /
    • pp.11-23
    • /
    • 2023
  • Purpose : The stress of job-seeking college students is gradually worsening due to the continuing recession in the job market. Therefore, this study aims to verify whether intervention with an 'aromatherapy education program,' which combines theory and practice, has greater effect on stress, self-efficacy, and autonomic nervous system function than simple inhalation of essential oils in female college students preparing for employment. Methods : A single-blind, randomized controlled trial was conducted once a week for a total of 4 weeks with 29 female college students preparing for employment. Interventions included essential oil inhalation combined with an aromatherapy education program (experimental group(EG), n=14) and essential oil inhalation alone (control group(CG), n=15); measurements were taken before, immediately after, and 2 weeks after completion of the intervention. Evaluations were conducted using the job-seeking stress scale, stress VAS, self-efficacy scale, and a pulse-wave measuring instrument. Results : There were significant differences between the CG and EG groups with repeated measurements of job-seeking stress (p=.003), cognitive stress (p<.001), and self-efficacy (p<.001). There was a significant interaction between group and time. There were also significant differences between the CG and EG in terms of autonomic nervous system changes stress index(p=.047), total power(p=.029), high frequency(p=.036), and low frequency/high frequency ratio(p=.049). However, there was no significant difference in low frequency between the groups. Conclusion : The aromatherapy education program was more effective in improving job-seeking stress, cognitive stress, self-efficacy, and autonomic nervous system function than simple essential oil inhalation. For the aromatherapy education program to be useful as a complementary intervention for stress management in job seekers, it will be necessary to gather additional evidence of its efficacy by conducting follow-up studies with diverse participants and expanding the numbers, and durations, of the interventions.

Controls on KSTAR Superconducting Poloidal Field (PF) Magnets

  • Hahn, Sang-Hee;Kim, K.H.;Choi, J.H.;Ahn, H.S.;Lee, D.K.;Park, K.R.;Eidietis, N.W.;Leuer, J.A.;Walker, M.L.;Yang, H.L.;Kim, W.C.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.10 no.4
    • /
    • pp.23-28
    • /
    • 2008
  • As a part of the plasma control system (PCS) for the first plasma campaign of KSTAR, seven sets of fast feedback control loop for the superconducting poloidal field magnet power supply (PF MPS) have been implemented. A special real-time digital communication interface has been developed for the simultaneous exchanges of the current/voltage data from the 7 sets of 12-thyristor power supplies in a 200 microsecond control cycle. Preliminary power supply tests have been performed before actual cooldown of the device. A $29mH/50m{\Omega}$ solenoid dummy has been fabricated for a series of single power supply tests. Connectivity and response speed of the plasma control system have been verified. By changing hardware cabling, this load was also used to estimate mutual inductance coupling effects of two geometrically adjacent solenoid coils on each power supply. After the cooldown was complete, each pair of the up/down symmetric PF coils has been serially connected and tested as part of the device commissioning process. Bipolar operation and longer pulse attempts have been investigated. The responses of the coils and power supplies corresponding to the plasma magnetic controls in plasma discharges are also analyzed for the future upgrades.