• Title/Summary/Keyword: single phase test

Search Result 444, Processing Time 0.03 seconds

A Study of X-ray Output for Diagnostic X-ray Equipment (진단용 X선 발생 장치의 X선 출력에 관한 연구)

  • Ko, Shin-Gwan;Ahn, Bong-Seon;Jang, Sang-Sup;Choi, Jong-Woon;Shin, Young-Soon
    • Journal of radiological science and technology
    • /
    • v.18 no.2
    • /
    • pp.61-73
    • /
    • 1995
  • For the managements of the diagnostic X-ray equipments, the authors examined the output of single phase rectification assembly, Three phase rectification assembly and serial radiographic appartus, and got the following conclusions. 1. When the tube voltages in X-ray control panels ware compared to the measured values on the kVp pulse meter, only little differences were detected in all the X-ray equipments. And most of the equipments were all well managed within the internationally permitted limits, excepting the 12.02 % error at 120 kVp in three phase rectifying assembly. 2. As for the X-ray qualities affecting the X-ray images, the serial radiographic apparatus showed excellence, while the single phase rectification assembly were somewhat inferior to the others only maining the internationally recommended limits. 3. The tube voltage ranges where the X-ray output showed excellence were $100{\sim}200\;mA$ in serial radiographic apparatus, $200{\sim}350\;mA$ in three phase rectification assembly and $350{\sim}400\;mA$ in single phase rectification assembly respectively. 4. In the repeatability test of the X-ray equipments, CVs were in the range of $0.0029{\sim}0.049$, which is within the HEW or KS standards. Consequently all the equipments are thought to be well-manage. 5. This study on characteristics and output of the X-ray equipments was accomplished within a limited short time. Long-time researches on the function managements for the X-ray equipments should be followed along with the periodical checking the output for reduction of X-ray exposures to the patients or radio-technologists, and for maintanance and prediction of trouble of the equipments.

  • PDF

Simulation of Two-Phase Fluid Flow in a Single Fracture Surrounding an Underground LPG Storage Cavern: II. Verification of Numerical Model and Field Application (지하 LPG 저아공동에 인접한 단일절리에서의 이상유체거동해석: II. 수치모형의 검증 및 적용)

  • Han, Il-Yeong;Seo, Il-Won
    • Journal of Korea Water Resources Association
    • /
    • v.34 no.5
    • /
    • pp.449-458
    • /
    • 2001
  • In order to verify the numerical model, which was developed to simulate the behavior of the two-phase fluid flow in a single fracture, the characteristic equation of relative permeability was incorporated into the developed numerical model, and the computed results were compared with the experimental results of the model test. As results of the sensitivity analysis on the roughness and the aperture size of fracture, the gas velocity was inversely proportional to the fracture roughness, and not proportional to the square of aperture size which is usually observed in single phase flow in a single fracture. The numerical model was applied to the underground LPG storage terminal in order to check the field applicability. The simultaneous flow of water and gas in accordance with the operation pressures in a single fracture near cavern was simulated by the model. It was shown that the leaked gas was able to be controlled in a single fracture neither by the pressure of operation nor by that of groundwater in case the fracture became smoother in roughness and smaller in aperture size.

  • PDF

Single-Pass Induction Motor Parameter Identification Method Taking Into Account Saturation and Rotor Parameter Variations

  • McKinnon, Douglas J.;Grantham, Colin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.3-9
    • /
    • 2012
  • The paper describes a novel technique for on line parameter identification of three-phase induction motors from a single, run up to speed test. Data is sampled during this test with the normal locked rotor and synchronous speed data captured on the way to reaching the motor's rated speed. Rotor parameter variations with frequency due to skin and proximity effects and other non-linear imperfections such as heating and main flux path saturation are taken into account. This method is ideal for determining and/or verifying parameters used in high performance drives.

Phase-shifting diffraction grating interferometer for testing concave mirrors (오목 거울 측정용 위상천이 회절격자 간섭계)

  • 황태준;김승우
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.4
    • /
    • pp.392-398
    • /
    • 2003
  • We present a novel concept of a phase-shifting diffraction-grating interferometer, which is intended for the optical testing of concave mirrors with high precision. The interferometer is configured with a single reflective diffraction grating, which performs multiple functions of beam splitting, beam recombination, and phase shifting. The reference and test wave fronts are generated by means of reflective diffraction at the focal plane of a microscope objective with large numerical aperture, which allows testing fast mirrors with low f-numbers. The fiber-optic confocal design is adopted for the microscope objective to focus a converging beam on the diffractive grating, which greatly reduces the alignment error between the focusing optics and the diffraction grating. Translating the grating provides phase shifting, which allows measurement of the figure errors of the test mirror to nanometer accuracy.

Effect of Al Addition on the Cryogenic-Temperature Impact Properties of Austenitic Fe-23Mn-0.4C Steels (알루미늄 첨가에 따른 오스테나이트계 Fe-23Mn-0.4C 고망간강의 극저온 충격 특성)

  • Kim, Sang-Gyu;Kim, Jae-Yoon;Yun, Tae-Hee;Hwang, Byoungchul
    • Korean Journal of Materials Research
    • /
    • v.31 no.9
    • /
    • pp.519-524
    • /
    • 2021
  • The impact properties of two austenitic Fe-23Mn-0.4C steels with different Al contents for cryogenic applications are investigated in this study. The 4Al steel consists mostly of austenite single-phase microstructure, while the 5Al steel exhibits a two-phase microstructure of austenite and delta-ferrite with coarse and elongated grains. Charpy impact test results reveal that the 5Al steel with duplex phases of austenite and delta-ferrite exhibits a ductile-to-brittle transition behavior, while the 4Al steel with only single-phase austenite has higher absorbed energy over 100 J at -196 ℃. The SEM fractographs of Charpy impact specimens show that the 4Al steel has a ductile dimple fracture regardless of test temperature, whereas the 5Al steel fractured at -100 ℃ and -196 ℃ exhibits a mixed fracture mode of both ductile and brittle fractures. Additionally, quasi-cleavage fracture caused by crack propagation of delta-ferrite phase is found in some regions of the brittle fracture surface of the 5Al steel. Based on these results, the delta-ferrite phase hardly has a significant effect on absorbed energy at room-temperature, but it significantly deteriorates low-temperature toughness by acting as the main site of the propagation of brittle cracks at cryogenic-temperatures.

A Study on the Characteristic of Weld Joint and Tensile Fracture of SUS304 and Cu High-Speed Dissimilar Lap Welds by Single Mode Fiber Laser (싱글모드 파이버 레이저를 이용한 SUS304와 Cu의 고속 겹치기 용접에서 접합부 및 인장시험 파단부의 특성에 관한 연구)

  • Lee, Su-Jin;Kim, Jong-Do;Katayama, Seiji
    • Journal of Welding and Joining
    • /
    • v.32 no.6
    • /
    • pp.56-63
    • /
    • 2014
  • To develop and understand dissimilar metals joining of Stainless steel and Copper, ultra-high speed laser lap welding was studied using single mode fiber laser in this study. SUS304 and Cu have large differences in materials properties, and Cu and Fe have no intermetallic compounds by typical binary phase of Cu and Fe system. In this study, ultra-high speed lap welds of SUS304 and Cu dissimilar metals using single-mode fiber laser was generated, and weldability of the weld fusion zone was evaluated using a tensile shear test. To understand the phenomenon of tensile shear load, weld fusion zone of interface weld area and fracture parts after tensile shear test were observed using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX) analysis system. And it was confirmed that Cu was easily melting and penetrating in the grain boundaries of SUS304 because of low melting temperature. And high thermal conductivity of copper occurred dissipate heat energy rapidly. These properties cause the solidification cracking in weld zone.

Phase and Amplitude Drift Research of Millimeter Wave Band Local Oscillator System

  • Lee, Chang-Hoon;Je, Do-Heung;Kim, Kwang-Dong;Sohn, Bong-Won
    • Journal of Astronomy and Space Sciences
    • /
    • v.27 no.2
    • /
    • pp.145-152
    • /
    • 2010
  • In this paper, we developed a local oscillator (LO) system of millimeter wave band receiver for radio astronomy observation. We measured the phase and amplitude drift stability of this LO system. The voltage control oscillator (VCO) of this LO system use the 3 mm band Gunn oscillator. We developed the digital phase locked loop (DPLL) module for the LO PLL function that can be computer-controlled. To verify the performance, we measured the output frequency/power and the phase/amplitude drift stability of the developed module and the commercial PLL module, respectively. We show the good performance of the LO system based on the developed PLL module from the measured data analysis. The test results and discussion will be useful tutorial reference to design the LO system for very long baseline interferometry (VLBI) receiver and single dish radio astronomy receiver at the 3 mm frequency band.

A Design Optimization of Asymmetric Air-gap Structure for Small 3-phase Permanent Magnet SPM BLDC Motor

  • Kam, Seung-Han;Jung, Tae-Uk
    • Journal of Magnetics
    • /
    • v.20 no.1
    • /
    • pp.91-96
    • /
    • 2015
  • As many researchers are relentlessly trying to improve the power generation schemes from the power grid, to meet the constantly increasing electricity demand. In this paper, the results of a finite element analysis are carried out to study on a design optimization of an asymmetric air-gap structure in 3-phase Permanent Magnet Brushless DC Motors. To achieve a high efficiency for a 3-phase PM BLDC motor, the asymmetric air-gap structure is proposed considering the rotation direction of a motor. Generally, a single-phase BLDC motor is applied asymmetric air-gap structure for starting. This is because the asymmetric air-gap structure causes reluctance variation so the motor can utilize reluctance torque toward a rotation direction. In this paper, the asymmetric air-gap is applied to 3-phase BLDC SPM motor so it utilizes reluctance torque with alignment torque. A proposed model is designed by 2-D FE analysis and the results are verified by experimental test.

Implementation of SSB/BPSK-DS/CDMA Baseband Modem (SSB/BPSK-DS/CDMA Baseband 모뎀 설계 및 구현)

  • 노시창;임명섭
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.5-8
    • /
    • 2001
  • SSB(Single Sideband) modulation scheme is high bandwidth efficient method in the mobile communication system compared with present DSB(Double Sideband) modulation scheme. Using the othogonality between inphase PN code and Hilbert transformed quadrature PN code, we propose phase estimation structure that enables coherent demodulation in the reverse link basestation receiver Several system characteristics, bit error rate and phase error variance, are simulated and compared with balanced QPSK DS/CDMA system. To verify system performance, SSB/BPSK-DS/CDMA test board is implemented using FPGA chips.

  • PDF

A Study on the 22.9KVY Multiground Distribution System (22.9KVY 배전방식에 관한 연구)

  • Sung Bong Byon
    • 전기의세계
    • /
    • v.22 no.6
    • /
    • pp.8-18
    • /
    • 1973
  • This paper is a part from the series study on the 22.9KVY multiground destribution system and its is divided into three parts as follow. A.C. Network Analyzer study on the load current flow when one phase line of the feeder is out of seroice because of cutting. A.C. Network Analyzer study on the increasing zero sequence current in the good feeders when one feeder is under fault of single phase short. Field test report of the common use of open telephone line on same poles of 22.9KVY distribution system.

  • PDF