• 제목/요약/키워드: single phase

검색결과 5,346건 처리시간 0.031초

단상 인버터로 구성된 3상 구형파 인버터의 고조파 저감기법에 관한 연구 (A Study on the Harmonic Reduction Technique in Three-Phase Square-Wave Inverters Formed by Single-Phase Inverters)

  • 조승연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.355-359
    • /
    • 2000
  • This paper deal with the harmonic reduction technique in three-phase square-wave inverter system formed by single-phase inverter. To reduce the harmonics six single-phase inverters are used for forming multi-phase inverter and zig-zag connected output transformer for eliminating the harmonic 6(2k-1)$\pm$1 orders. And an ac filter is furnished at output side. Computer simulations show that the THD of the output voltage can be reduced immensely.

  • PDF

분리된 삼상 자속구속형 전류제한기와 일체화된 삼상 자속구속형 전류제한기의 전류제한 특성 비교 (Comparison of Fault Current Limiting Characteristics between the separated Three-phase Flux-lock Type SFCL and the Integrated Three-phase Flux-lock Type SFCL)

  • 두승규;두호익;김민주;박충렬;김용진;이동혁;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제22권8호
    • /
    • pp.689-693
    • /
    • 2009
  • We investigate the comparison of fault current characteristics between the separates three-phase flux-lock type superconducting fault current limiter(SFCL) and integrated three-phase flux-lock type superconducting fault current limiter(SFCL). The single-phase flux-lock type SFCL consists of two coils. The primary coil is wound in parallel to the secondary coil on an iron core and superconducting elements are connected to secondary coil in series. Superconducting elements are used by the YBCO coated conductor. The separated three-phase flux-lock type SFCL consists of single-phase flux-phase type SFCL in each phase. But the integrated three-phase flux-lock type SFCL consists of three-phase flux-reactors wound on an iron core. Flux-reactor consists of the same turn's ratio between coil 1 and coil 2 for each single phase. To compare the current limiting characteristics of the separated three-phase flux-lock type SFCL and integrated three-phase flux-lock type SFCL, the short circuit experiments are carried out fault condition such as the single line-to-ground fault. The experimental result shows that fault current limiting characteristic of the separated three-phase flux-lock type SFCL was better than integrated three-phase flux-lock type SFCL. And the integrated three-phase flux-lock type SFCL has an effect on sound phase.

단상 SRM의 여자 구간에 따른 구동 특성 (Driving Characteristics of Single Phase SRM with Exciting Section)

  • 여상겸;이은웅;이민명
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.912-914
    • /
    • 2002
  • Single phase SRM(Switched Reluctance Motor) can not be started by itself and torque ripple is more generated than multi-phase SRM. But it is excited by single phase current and has very simple structure. Therefore it can be used in domestic appliance. Torque and speed of single phase SRM is controlled by adjusting exciting current and exciting section. Driver, which is composed with absolute encoder and DSP, is fabricated for control of exciting section on this paper. Then driving characteristics with exciting section is confirmed by using salient pole rotor type single phase SRM, which is fabricated in preceding research.

  • PDF

비례 - 적분 제어기를 이용한 단상 유도 전동기의 속도 제어 (The speed control of the Single-Phase induction motor using P-I controller)

  • 상두환;정달호;김정철;오민진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.603-605
    • /
    • 1994
  • The Single-Phase induction motor is widely used in home appliances, especially refrigerator, air conditioner and washing machine. Recently many home appliances that use the motor require the speed control to get the various and convenient functions for the customers. Generally it is so hard to control the speed of the Single-Phase induction motor and to get the wide range of the speed variation. In this raper, the speed controller using P-I is designed for the Single-Phase induct ion Motor. The experimental results of the phase controller using P-I show the wide speed control of the Single-Phase induction motor and rebuff control to load change.

  • PDF

전류파형을 변조한 단상유도전동기구의 특성에 관한 연구 (Performances of Current-Waveform Modulated Single-Phase Induction Machine)

  • 황영문;김철우;박용규
    • 전기의세계
    • /
    • 제24권1호
    • /
    • pp.55-62
    • /
    • 1975
  • A single-phase induction motor with it's stator winding splitted into two series windings, of which the terminals of one winding is switched pulsationally by a thyristor type ON-OFF device so that the motor may operate as a pulsational shaded-pole motor, can modulate current waveforms of it's two series windings. In view of current waveform modulation method, a single-phase single-winding motor operates as a two-phase induction motor with asymmetrical axis windings where the starting torque can be obtained effectively without an auxiliary capacitor attached and it's running speed controlled by shifting phase between current waveforms differently. Equivalent circuit for analysis is modified from a double revolving field equivalent circuit of a single-phase induction motor with asymmetrical windings whose angle is 45.deg.C elet. degrees. Analysis and test results show that ON-OFF action of the pulsational shaded-pole winding has the same effect of a series capacitor, and then at heavy loads this motor operates with a small amonut of the input current than that having the fixed shaded-pole winding.

  • PDF

Compensating Characteristics of Voltage Sag Compensator Utilizing Single-Phase Matrix Converter

  • Yamamoto, Kichiro;Ikeda, Keisuke;Iimori, Kenichi
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.77-82
    • /
    • 2013
  • By using simulation, compensating characteristics of a voltage sag compensator utilizing single-phase matrix converter is examined. System configuration is described and mathematical model of single-phase matrix converter is derived by using the state space averaging method. In addition, the single-phase matrix converter is stabilized by phase-lead compensation. Finally, compensating characteristics of the compensator is investigated for 500 W R-L load and it is demonstrated that the compensator can operate correctly for loads for the range of power factor 0.6 (lagging) - 0.8 (leading) and for up to 50% voltage sag.

범용 기동기에 의한 단상유도전동기의 보조권선 제어 특성 (The Auxiliary Winding Control Characteristics of Single-Phase Induction Motor by Universal Starting Switch)

  • 임홍우;임병옥;정수복;조금배;백형래
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권6호
    • /
    • pp.396-401
    • /
    • 2004
  • Single phase induction motor(SPIM) is one of the most widely used type of low power AC motors in the world, especially for domestic or commercial applications where a three phase power supply is not available. Single phase induction motors have no starting torque their own. So there are several ways of starting single phase induction motors. The most common type is the starting capacitor installed in series with the auxiliary winding to increase the starting torque. In the conventional systems, this function is conducted by a centrifugal switch. But the mechanical centrifugal switch has many problems such as switch malfunction. This paper presents the auxiliary winding control using digital universal starting switch to overcome these shortcomings of centrifugal switch.

d-q이론을 이용한 개통 연계형 단상 인버터 제어기 설계기법 (Controller Design of Utility-connected Single-phase Inverter using d-q Theory)

  • 박창주;김창현;김명철;최재영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1247-1249
    • /
    • 2003
  • Despite many advantages, d-q theory was available only for three phase system. But recently, some papers proposed the application methods of d-a theory or similar theories for single phase systems. This paper presents the control method of the utility-connected single-phase inverter using d-q theory. The suggested method gives single-phase system instantaneous controllability and also makes the realization of APF(Active Power Filter) without DFT operation and PFC(Power Factor Controller) possible. This paper deals with utility-connected single phase inverter with PFC function. The controller was verified by simulation tool.

  • PDF

Electric Field-Induced Phase Transition Behavior in Tetragonal Pb(Zn1/3Nb2/3)O3-PbTiO3 Single Crystals

  • Jeong, Dae-Yong;Kim, Jin-Sang;Kim, Hyun-Jai;Yoon, Seok-Jin
    • 한국세라믹학회지
    • /
    • 제43권7호
    • /
    • pp.389-392
    • /
    • 2006
  • Electric field-induced phase transition from the tetragonal to rhombohedral phase was investigated for the <111> direction in tetragonal PZN-PT single crystals, which have spontaneous polarization along the <001> direction. From the strain and dielectric data, it was confirmed that the samples followed a tetragonal-orthorhombic-rhombohedral phase transition sequence with application of an electric field. This transition is different from the rhombohedral-tetragonal phase transition of <001> rhombohedral composition single crystals, in which a phase transition occurred without showing the intermediate orthorhombic phase.

A New Control Method for a Single-Phase Hybrid Active Power Filter based on a Rotating Reference Frame

  • Kim, Jin-Sun;Kim, Young-Seok
    • Journal of Power Electronics
    • /
    • 제9권5호
    • /
    • pp.718-725
    • /
    • 2009
  • To get instantaneous reference data in a single power system with vector space phasors, the instantaneous load current is adopted as a phase and another new signal, which is delayed through filtering by the phase-delay property of a low-pass filter, is used as the secondary phase. Because the two-phases have a different phase, the instantaneous value of the harmonic current can be obtained without a time-delay in calculation. The reference voltage is created by multiplying the coefficient k by the compensation current using the rotating reference frame synchronized with the source-frequency. To verify the validity of the proposed control method, experiments are carried out on a prototype of the single-phase hybrid active power filter system.