• 제목/요약/키워드: single event effects

검색결과 76건 처리시간 0.025초

The Implementation of Testing Board forSingle Event Upsets

  • Lho, Young-Hwan;Kim, Ki-Yup
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제5권2호
    • /
    • pp.28-34
    • /
    • 2004
  • One of the major problem encountered in nuclear plants and satellites design isEMI (Electro-Magnetic Interference) and EMC (Electro-Magnetic Compatibility).Here, our focus is to implement the test board for checking SEU (Single EventUpsets); the effects of protons on the electronic system. The SEU results from thelevel change of stored information due to photon radiation and temperature in thespace environment. The impact of SEU on PLD (Programmable Logic Devices)technology is most apparent in ROM/SRAM/DRAM devices wherein the state ofstorage cell can be upset. In this paper, a simple and powerful test techniques issuggested, and the results are presented for the analysis and future reference. In ourexperiment, the proton radiation facilitv (having the energy of 50 MeV with a beamcurrent of 60 uA of cyclotron) available at KIRAMS (Korea Institute of RadiologicalMedical Sciences) has been applied on a commercially available SRAM manufacturedby Hynix Semiconductor Company.

과학기술위성 3호 탑재 컴퓨터와 대용량 메모리에 적용될 오류 복구 코드의 비교 및 분석 (Analysis and Comparison of Error Detection and Correction Codes for the Memory of STSAT-3 OBC and Mass Data Storage Unit)

  • 김병준;서인호;곽성우
    • 전기학회논문지
    • /
    • 제59권2호
    • /
    • pp.417-422
    • /
    • 2010
  • When memory devices are exposed to space environments, they suffer various effects such as SEU(Single Event Upset). Memory systems for space applications are generally equipped with error detection and correction(EDAC) logics against SEUs. In this paper, several error detection and correction codes - RS(10,8) code, (7,4) Hamming code and (16,8) code - are analyzed and compared with each other. Each code is implemented using VHDL and its performances(encoding/decoding speed, required memory size) are compared. Also the failure probability equation of each EDAC code is derived, and the probability value is analyzed for various occurrence rates of SEUs which the STSAT-3 possibly suffers. Finally, the EDAC algorithm for STSAT-3 is determined based on the comparison results.

HAUSAT-2 위성의 방사능 환경해석 및 소프트웨어 HAMMING CODE EDAC의 구현에 관한 연구 (HAUSAT-2 SATELLITE RADIATION ENVIRONMENT ANALYSIS AND SOFTWARE RAMMING CODE EDAC IMPLEMENTATION)

  • 정지완;장영근
    • Journal of Astronomy and Space Sciences
    • /
    • 제22권4호
    • /
    • pp.537-558
    • /
    • 2005
  • 본 논문에서는 HAUSAT-2위성이 운용될 케도의 우주 방사능 환경 및 총 피폭효과(Total Ionizing Dose), 단일사건 효과(Single Event Effects) 등에 대해 분석하였다. 총 피폭효과에 영향을 미치는 우주 방사능은 포획된 양성자, 전자, 태양 양성자 및 우주선이다. 총 피폭효과는 선량 심도선 분석을 통해 해석을 수행하였으며, DMBP(Design Margin Breakpoint) 방법과 3-D 구분구적법을 이용하여 HAVSAT-2의 부품의 총 피폭량에 대한 내성을 검증하였다. 단일사건 효과에 대하여 위성체 외부와 내부 방사능 환경으로 양성자와 중이온에 대하여 선형에너지 전달량(LET) 스펙트럼을 분석하였으며, HAUSAT-2의 전자소자로 사용예정인 MPC860T2B 마이크로프로세서와 메모리 K6X8008T2B에 대한 SEU(Single Event Upset) 및 SEL(Single Event Latch-up) 발생률을 추정하였다. 분석 결과 SEU는 운용 중에 수차례 발생하며 SEL 발생은 임무기간동안 일어나지 않을 것으로 추정되었다. HAUSAT-2는 소프트웨어 해밍코드 EDAC을 이용하여 SEU 발생에 대처할 수 있는 시스템 레벨의 설계를 반영하였다. 이 연구에서 수행된 방사능 해석은 ESA의 SPENVIS소프트웨어를 이용하였다.

우리별 1호에서의 SPACE RADIATION 환경 조사 (CRE ECPERIMENT OF KITSAT-1)

  • 신영훈;민경욱;최영완;김성헌
    • Journal of Astronomy and Space Sciences
    • /
    • 제11권1호
    • /
    • pp.131-145
    • /
    • 1994
  • Cosmic Ray Experiment (CRE)는 KITSAT-1 의 여 러 module 중 하나로 Total D Dose Experiment (TDE) 와 Cosmic Particle Experiment (CPE) 두개의 sub-system 으로 구성되어 있다. CRE 의 목적은 KITSAT-1 궤도에서의 우주 환경을 조사하는 것이다. KITSAT-1 의 궤도는 inner Van Allen belt에 위치하며, 이 지역 에셔는 고에너지 proton들이 많이 분포하고 있어 위성체에 단기적인 또는 장기적인 radiation 효과를 미치고 있다. 1년여의 설험 결과로부터 Van Allen belt가 무척 안정되어 있고 태양의 활동이 CPE,TDE 및 SEU (Single Event Upset) rate 에 영향을 줌을 알 수 있었다. 또한 CREME code 에 의해 예상됐던 것보다 많은 고에너지 입자 flux가 관찰되었다.

  • PDF

Recent Advances in Radiation-Hardened Sensor Readout Integrated Circuits

  • Um, Minseong;Ro, Duckhoon;Kang, Myounggon;Chang, Ik Joon;Lee, Hyung-Min
    • Journal of Semiconductor Engineering
    • /
    • 제1권3호
    • /
    • pp.81-87
    • /
    • 2020
  • An instrumentation amplifier (IA) and an analog-to-digital converter (ADC) are essential circuit blocks for accurate and robust sensor readout systems. This paper introduces recent advances in radiation-hardening by design (RHBD) techniques applied for the sensor readout integrated circuits (IC), e.g., the three-op-amp IA and the successive-approximation register (SAR) ADC, operating against total ionizing dose (TID) and singe event effect (SEE) in harsh radiation environments. The radiation-hardened IA utilized TID monitoring and adaptive reference control to compensate for transistor parameter variations due to radiation effects. The radiation-hardened SAR ADC adopts delay-based double-feedback flip-flops to prevent soft errors which flips the data bits. Radiation-hardened IA and ADC were verified through compact model simulation, and fabricated CMOS chips were measured in radiation facilities to confirm their radiation tolerance.

Irrigation Frequency and Nitrogen Rates for Tall Fescue Growth

  • Lee, Sang-Kook
    • Weed & Turfgrass Science
    • /
    • 제3권2호
    • /
    • pp.130-136
    • /
    • 2014
  • Tall fescue is commonly well-adapted for low maintain area because of its wear resistance, deep root system, and drought tolerances. Deep and infrequent irrigation refers to applying large amounts of irrigation, 1.3 to 2.5 cm or more, in a single irrigation event. Light and frequent irrigation is commonly used with small amounts of water, 0.3 to 0.6 cm, every day or every other day. N use for turfgrass management is often unnoticed for water management. The objective of this field study was to evaluate the effects of irrigation frequency and N rates for tall fescue growth. The three irrigation treatments were no irrigation (precipitation only), 0.5 cm applied every other day, and 1.8 cm applied once a week at one irrigation event. The nitrogen (N) treatments were the low, medium, and high N rate treatments. The low, medium, and high N treatments were applied over 2, 4, and 6 applications, respectively. If high main maintenance of tall fescue is not important and water source is limited, irrigation is not necessary and, the $9.8gNm^{-2}yr^{-1}$ of two applications can be recommended for tall fescue under the weather condition of the study.

다목적댐군의 실제 연계운영 효과 평가 (Evaluation of Effects of Real Joint-Operation of Multi-purpose Dams)

  • 강민구;이광만;차형선
    • 한국수자원학회논문집
    • /
    • 제40권2호
    • /
    • pp.101-112
    • /
    • 2007
  • 본 연구에서는 댐군을 연계운영할 경우 발생하는 효과를 이수측면에서 평가할 수 있는 방법을 개발하여 한강수계 댐군 운영 실적의 평가에 적용하였다. 개발된 평가방법에서는 용수공급과 유황개선 부분에서 연계운영의 효과를 평가하기 위하여 평가지점에서 필요수량에 대한 충족률과 유황안정도를 평가지표로 사용하였다 발전 부분에서 연계운영의 효과는 댐군에 의해 생산된 총발전량을 평가지표로 사용하였다. 실제 운영실적은 공칭공급량을 공급하는 단독운영과 최적화 모형에 의한 평가지표들과 비교하여 평가되었다. 한강수계의 2001년부터 2004년까지의 실제 연계운영 실적을 단독운영과 최적화 모형의 결과와 각 연도별로 비교해 보면, 용수공급 측면에서 필요수량 충족률은 단독운영은 $94.36{\sim}99.68%$, 실제운영은 $97.16{\sim}99.90%$, 최적화 모형은 4개년 모두 100.0 %를 나타냈다. 댐 운영 방법별로 하상계수와 유황계수를 사용하여 유황안정도를 평가해 보면, 유황이 단독운영 보다 실제운영과 최적화 모형이 더 안정적인 결과를 나타냈다. 실제 총발전량을 다른 운영방법의 결과와 비교해 보면, 최적화 모형은 실제 총발전량 보다 $-3.47{\sim}6.54%$ 증가된 결과를 나타냈으며, 단독운영은 실제 총발전량 보다 $12.68{\sim}38.94%$ 감소된 결과를 나타냈다.

과학기술위성 3호 대용량 메모리에서의 SEU 극복 및 확률 해석 (SEU Mitigation Strategy and Analysis on the Mass Memory of the STSAT-3)

  • 곽성우
    • 전자공학회논문지SC
    • /
    • 제45권4호
    • /
    • pp.35-41
    • /
    • 2008
  • 메모리 소자가 우주 환경에 노출되면 우주 방사능에 의해 메모리의 값이 변하는 SEU 현상이 발생한다. 이러한 현상에 대처하기 위하여 위성체에 사용되는 메모리는 필연적으로 오류 탐지 및 극복 기법을 탑재하고 있다. 본 논문에서는 과학기술위성 3호 대용량 메모리 유닛에서 채택하게 될 오류 탐지 및 극복 방식을 알아본다. 오류 극복을 위해 대용량 메모리를 RS(10,8) Reed-solomon 코드로 인코딩/디코딩했을 때 SEU에 의해 메모리의 데이터가 손상 받을 확률을 계산한다. 이 확률식을 기반으로 과학기술위성 3호가 직면할 수 있는 다양한 SEU 발생율에 대하여 그 확률 변화를 분석한다. 이것으로부터 과학기술위성 3호 대용량 메모리 유닛 설계의 중요한 요소 중의 하나인 메모리 인코딩/디코딩 주기를 결정하는데 이용하고자 한다.

Helicobacter pylori infection에 대한 한약과 합성의약품 병용투여 효과에 대한 메타분석 및 체계적 문헌고찰 : PubMED를 중심으로 (Meta-analysis and Systematic Review on the Effects of Herbal Medicine and Synthetic Drugs in Helicobacter pylori Infection: Focusing on PubMED)

  • 정설;곽승연;조은지;정의민
    • 대한본초학회지
    • /
    • 제36권5호
    • /
    • pp.69-79
    • /
    • 2021
  • Objectives : In clinical practice, there are many cases of co-administration of herbal medicine and synthetic drugs. This study tried to identify whether the combined administration of herbal medicine and synthetic drugs including amoxicillin increases Helcicobacter pylori eradication rate compared to the single administration of synthetic drugs or the combined administration of synthetic drugs and placebo herbal medicine through systematic review. Methods : Relevant randomized controlled trials were searched in PubMED database. The risk of biases was assessed through the Cochrane Risk of Bias criteria. Three reviewers were extracted the characteristics and outcomes of each study. Meta-analysis of eradication rate and adverse event was conducted. Results : Four RCTs were selected. In meta-analysis, the combination of herbal medicine and synthetic drugs showed eradication effect, but it was not statistically significant (Odds Ratio [OR] 0.46; 95% confidence interval [CI] 0.17 to 1.24; p=0.13; I2=56%) than administration of synthetic medicine alone. Combination of herbal medicine and synthetic medicine did not increased the incidence of adverse event(OR 1.07; 95% CI 0.72 to 1.59; p=0.68, I2=0%) compared to single administration of synthetic medicine. Conclusion : Although no significant difference was observed between the two groups in the eradication rate and the incidence rate of adverse events, it was difficult to draw a clear conclusion due to the heterogeneity between studies and the low quality of reporting. A number of studies that have overcome these limitations in the future will lead to definite conclusions.

Impact of gamma radiation on 8051 microcontroller performance

  • Charu Sharma;Puspalata Rajesh;R.P. Behera;S. Amirthapandian
    • Nuclear Engineering and Technology
    • /
    • 제54권12호
    • /
    • pp.4422-4430
    • /
    • 2022
  • Studying the effects of gamma radiation on the instrumentation and control (I&C) system of a nuclear power plant is critical to the successful and reliable operation of the plant. In the accidental scenario, the adverse environment of ionizing radiation affects the performance of the I&C system and it leads to inaccurate and incomprehensible results. This paper reports the effects of gamma radiation on the AT89C51RD2, a commercial-off-the-shelf 8-bit high-performance flash microcontroller. The microcontroller, selected for the device under test for this study is used in the remote terminal unit for a nuclear power plant. The custom circuits were made to test the microcontroller under different gamma doses using a 60Co gamma source in both ex-situ and in-situ modes. The device was exposed to a maximum dose of 1.5 kGy. Under this hostile environment, the performance of the microcontroller was studied in terms of device current and voltage changes. It was observed that the microcontroller device can operate up to a total absorbed dose of approximately 0.6 kGy without any failure or degradation in its performance.