• Title/Summary/Keyword: simultaneous scanning

Search Result 89, Processing Time 0.027 seconds

Derivation of the Ambient Nitrogen Dioxide Mixing Ratio over a Traffic Road Site Based on Simultaneous Measurements Using a Ground-based UV Scanning Spectrograph

  • Lee, Han-Lim;Noh, Young-Min;Ryu, Jae-Yong;Hwang, Jung-Bae;Won, Yong-Gwan
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.96-102
    • /
    • 2011
  • Simultaneous measurements using a scanning spectrograph system and transmissometer were performed for the first time over an urban site in Gwangju, Korea, to derive the ambient $NO_2$ volume mixing ratio. The differential slant column densities retrieved from the scanning spectrograph system were converted to volume mixing ratios using the light traveling distance along the scanning line of sight derived from the transmissometer light extinction coefficients. To assess the performance of this system, we compared the derived $NO_2$ volume mixing ratios with those measured by an in situ chemiluminescence monitor under various atmospheric conditions. For a cloudless atmosphere, the linear correlation coefficient (R) between the two data sets (i.e., data derived from the scanning spectrograph and from the in situ monitor) was 0.81; the value for a cloudy atmosphere was 0.69. The two sets of $NO_2$ volume mixing ratios were also compared for various wind speeds. We also consider the measurement errors, as estimated from an error propagation analysis.

Complete Simultaneous Analysis of Uranium Isotopes in NUSIMEP-7 Microparticles Using SEM-TIMS

  • Park, Jong-Ho;Jeong, Kahee
    • Mass Spectrometry Letters
    • /
    • v.7 no.3
    • /
    • pp.64-68
    • /
    • 2016
  • Scanning electron microscopy combined with thermal ionization mass spectrometry (SEM-TIMS) was used to determine the precise isotope ratios of ultra-trace levels of uranium contained in individual microparticles. An advanced multiple ion counter system consisting of three secondary ion multipliers and two compact discrete dynodes was used for complete simultaneous ion detection. For verification purposes, using TIMS with complete simultaneous measurement, isotopes were analyzed in 5 pg of uranium of a certified reference material. A microprobe in the SEM was used to transfer individual particles from a NUSIMEP-7 sample to TIMS filaments, which were then subjected to SEM-TIMS and complete simultaneous measurement. The excellent agreement in the resulting uranium isotope ratios with the certified NUSIMEP-7 values shows the validity of SEM-TIMS with complete simultaneous measurement for the analysis of uranium isotopes in individual particles. Further experimental study required for investigation of simultaneous measurement using the advanced multiple ion counter system is presented.

Nanometer-scale Imaging in Thin Films by Scanning Maxwell-stress Microscopy (주사형 맥스웰 응력 현미경을 이용한 박막의 Nanometer-scale 이미지)

  • 신훈규;유승엽;권영수
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.133-136
    • /
    • 1998
  • The scanning Maxwell-stress microscopy (SMM) is a dynamic noncontact electric force microscopy that allows simultaneous access to the electrical properties of molecular system such as surface potential, surface charge, dielectric constant and conductivity along with the topography. Here we report our recent results of its application to nanoscopic study of domain structures and electrical functionality in organic thin films prepared by the Langmuir-Blodgett technique.

  • PDF

Simultaneous growth of graphene and vertically aligned single-walled carbon nanotubes at low temperature by chemical vapor deposition

  • Hong, Suck Won;Kim, Kwang Ho;Jung, Hyun Kyung;Kim, Daesuk;Lee, Hyung Woo
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc1
    • /
    • pp.154-157
    • /
    • 2012
  • We present the simultaneous growth of single-walled carbon nanotubes and graphene with the optimal conditions of the synthesizing parameters. The dense and vertically aligned SWNTs having the length of over 100 ㎛ was grown by 2 nm-thick Fe catalytic layer. From 650 ℃, the vertically well-grown SWNTs were obtained by increasing the temperature. The severallayered graphene was synthesized with the gas mixing ratio of 15 : 1(H2 : C2H2) at 650 ℃ and higher temperatures. With these optimal conditions, the vertically well-grown SWNTs and the several-layered graphene were synthesized simultaneously. The presence of SWNTs and the layer of graphene were verified by field emission scanning electron microscopy and high resolution transmission electron microscopy. From the result of this simultaneous synthesizing approach, the possibility of one step growth process of CNTs and grapheme could be verified.

Precipitated Calcium Carbonate Synthesis by Simultaneous Injection to Produce Nano Whisker Aragonite

  • Ramakrishna, Chilakala;Thenepalli, Thriveni;Huh, Jae-Hoon;Ahn, Ji Whan
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.2
    • /
    • pp.222-226
    • /
    • 2016
  • The synthesis of pure calcium carbonate nanocrystals was achieved using a simultaneous injection method to produce nano particles of uniform size. These were characterized using scanning electron microscopy and powder X-ray diffraction. The nano particles were needle-shaped aragonite polymorphs, approximately 100-200 nm in length. The aragonite polymorph of calcium carbonate was prepared using aqueous solutions of $CaCl_2$ and $Na_2CO_3$, which were injected simultaneously into double distilled water at $50^{\circ}C$ and then allowed to react for 1.5 h. The resulting whisker-type nano aragonite with high aspect ratio (30) is biocompatible and potentially suitable for applications in light weight plastics, as well as in the medical, pharmaceutical, cosmetic and paint industries.

A study on the AC dielectric breakdown characteristics and mechanical characteristics of interpenetraing polymer network epoxy composites (상호침입망목 에폭시 복합재료의 교류절연파괴 특성 및 기계적 특성에 관한 연구)

  • 손인환;이덕진;김명호;김경환;김재환
    • Electrical & Electronic Materials
    • /
    • v.9 no.7
    • /
    • pp.702-707
    • /
    • 1996
  • In this paper, in order to improve the withstand voltage properties of epoxy resin, IPN(interpenetrating polymer network) method was introduced and the influence was investigated. The single network structure specimen(E series), simultaneous interpenetrating polymer network specimen(EM series) and pseudo interpenetrating polymer network(EMP series) specimen were manufactured. In order to understand the internal structure properties, scanning electron microscopy method was utilized, and glass transition temperature was measured. Also, AC voltage dielectric breakdown strength, tensile strength and impact strength were measured to investigate the influence upon electrical and mechanical properties. As a result, it was confirmed that simultaneous interpenetrating polymer network specimen was the most execellent.

  • PDF

Specimen Preparation for Scanning Electron Microscope Using a Converted Sample Stage

  • Kim, Hyelan;Kim, Hyo-Sik;Yu, Seungmin;Bae, Tae-Sung
    • Applied Microscopy
    • /
    • v.45 no.4
    • /
    • pp.214-217
    • /
    • 2015
  • This study introduces metal coating as an effective sample preparation method to remove charge-up caused by the shadow effect during field emission scanning electron microscope (FE-SEM) analysis of dynamic structured samples. During a FE-SEM analysis, charge-up occurs when the primary electrons (input electrons) that scan the specimens are not equal to the output electrons (secondary electrons, backscattered electrons, auger electrons, etc.) generated from the specimens. To remove charge-up, a metal layer of Pt, Au or Pd is applied on the surface of the sample. However, in some cases, charge-up still occurs due to the shadow effect. This study developed a coating method that effectively removes charge-up. By creating a converted sample stage capable of simultaneous tilt and rotation, the shadow effect was successfully removed, and image data without charge-up were obtained.

Development for Scanning Type Stage Driven by Linear Motors (리니어모터를 이용한 고속 저중심 스테이지의 개발과 정밀도 향상)

  • 송창규;김정식;김경호;박천홍
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.04a
    • /
    • pp.445-448
    • /
    • 2004
  • Linear motor is very rapidly substituted for rotary motor and ball screw for precision positioning applications because of its characteristics such as high speed, no backlash and simplicities. A precision positioning system which is composed of linear motion(LM) guide and linear motor is widely used since it has easy controllable property but this system has low accuracy problem caused by friction of the LM guide. In this study, a scanning type XY stage is manufactured and some experiments is performed to improve the accuracy of the stage.

  • PDF

Identifying Considerations for Developing SLAM-based Mobile Scan Backpack System for Rapid Building Scanning (신속한 건축물 스캔을 위한 SLAM기반 이동형 스캔백팩 시스템 개발 고려사항 도출)

  • Kang, Tae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.312-320
    • /
    • 2020
  • 3D scanning began in the field of manufacturing. In the construction field, a BIM (Building Information Modeling)-based 3D modeling environment was developed and used for the overall construction, such as factory prefabrication, structure construction inspection, plant facility, bridge, tunnel structure inspection using 3D scanning technology. LiDARs have higher accuracy and density than mobile scanners but require longer registration times and data processing. On the other hand, in interior building space management, relatively high accuracy is not needed, and the user can conveniently move with a mobile scan system. This study derives considerations for the development of Simultaneous Localization and Mapping (SLAM)-based Scan Backpack systems that move freely and support real-time point cloud registration. This paper proposes the mobile scan system, framework, and component structure to derive the considerations and improve scan productivity. Prototype development was carried out in two stages, SLAM and ScanBackpack, to derive the considerations and analyze the results.

Automation of urine dipstick test by simultaneous scanning : A pilot study (요 스트립검사 자동화를 위한 동시 비교 스캔 기법 예비 연구)

  • Lee, Sang-Bong;Choi, Seong-Su;Lee, In-Kwang;Han, Jeong-Su;Kim, Wan-Seok;Kim, Wun-Jae;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.169-175
    • /
    • 2010
  • Urinalysis is an important clinical test to diagnose urinary diseases, and dipstick method with visual inspection is widely applied in practice. Automated optical devices recently developed have disadvantages of long measurement time, big size and heavy weight, accuracy degradation with time, etc. The present study proposed a new computer scanning technique, in which the test strip and the standard chart were simultaneously scanned to remove any environmental artifacts, followed by automated differentiation with the minimum distance algorithm, leading to significant enhancement of accuracy. Experiments demonstrated an accuracy of 100 % in that all test results were identical with the human visual inspection. The present technique only uses a personal computer with scanner and shortens the test time to a great degree. The results are also stored and accumulated for later use which can be transmitted to remote locations through a network, thus could be easily integrated to any ubiquitous health care systems.