• Title/Summary/Keyword: simultaneous measurement

Search Result 490, Processing Time 0.03 seconds

Development of an Automated and Continuous Analysis System for PM2.5 and Chemical Characterization of the PM2.5 in the Atmosphere at Seoul (자동연속측정시스템 개발 및 이 시스템을 이용한 서울 대기 중 PM2.5의 화학적 조성과 특성에 관한 연구)

  • Lee Bo Kyoung;Kim Young Hoon;Ha Jae Yoon;Lee Dong Soo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.4
    • /
    • pp.439-458
    • /
    • 2005
  • An automated analysis system for water soluble constituents in $PM_{2.5}$ has been developed. The system consists of a high capacity multi tube diffusion scrubber (MTDS), a low temperature particle impactor (LTPI), and two ion (anion and cation) chromatography (IC) systems. Atmospheric particles have been collected by passing sample air through a thermostated MTDS followed by a LTPI. This system allows simultaneous measurements of soluble ions in $PM_{2.5}$ at 30 minutes interval. At the air sampling flow rate of 1.0L/min, the detection limits of the overall system are in the order of tens of $ng/m^3$. This system has been successfully used for the measurement of particulate components of Seoul air from April 2003 to January 2004. $SO_4^{2-},\;NO_3^-,\;NH_4^+,\;NO_2^-,\;Cl^-,\;Na^+,\;K^+,\;Ca^{2+},\;and\;Mg^{2+}$ are the major ionic species for $PM_{2.5}$ at Seoul. Among them, $SO_4^{2-},\;NO_3^-\;and\;NH_4^+$ are the most abundant ions, contributed up to $86\%$ of the total and the concentrations were higher than those in any other urban sites in the world except for Chinese cities. There are high pollutant episodes which contribute about $15\~20\%$ of annual average values of the major ions. During the episode, the all parcels were transported from the asian continent and $PM_{2.5}$ were significantly neutralized. This suggests that aged and long range transported pollutants caused the high pollutant episodes. They showed a distinct daily and seasonal variations:they showed a peak in the early morning caused by the night-time accumulation of particulate matters. Atmospheric reactions including gas-to-particle reactions and inter-particle reactions and meteorological parameters including relative humidity and ambient temperature were described with related to the $PM_{2.5}$ 5 concentrations. All of the ionic species showed higher concentrations during the spring than those for summer and winter.

A Study on Development of Power Analysing Device for PV Module (태양전지 모듈의 발전량 분석 장치 개발에 관한 연구)

  • Moon, Chae-Joo;Kwak, Seung-Hun;Jang, Yeong-Hak;Kim, Tae-Gon;Kim, Eui-Sun;Kim, Tae-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.6
    • /
    • pp.73-80
    • /
    • 2010
  • This study was conducted to estimate the relative performance of modules with changed characteristics due to long term exposure to the outdoor environment, with a specially made test device for simultaneous measurement of real time power output from the photovoltaic array, taking into account the inclined panel, direct irradiation, power being generated, temperature as well as the optimal analysis timing. In terminology description, M is an abbreviation of module and Group A, Group B are 10 modules series connection (1~10 of M), (11~20 of M) for each of them respectively. The overall mean voltage difference of M-18 with the lowest power output and M-14 with the highest output is-2.13V and it was identifiable that voltage difference was more concentrated to Group B. In addition, in case of M-2 and M-7, M-8, when compared with M-14, the overall mean voltage difference was -0.92V, -1.56 and -0.91V respectively showing the more concentration to Group A. When the temperature of module went up by $1^{\circ}C$, the mean voltage was reduced by 0.35V. For current, Group A was lower than Group B by-0.022A and the ratio of each group was 49.68% and 50.32% respectively, presumably the module with deteriorated properties were more concentrated to Group A relatively. From the comparison of relations with the comprehensive accumulation, M-2, M-7, M-8, M-16 and M-18 were those with deterioration of performance to the worst, thereby requiring precision examination. In comparative efficiency, M-14 was the most excellent one as 12.19% while M-18 as 10.53% was identified that its efficiency was comparatively rapidly reduced.

Derivation and Evaluation of Surface Reflectance from UAV Multispectral Image for Monitoring Forest Vegetation (산림 식생 모니터링을 위한 무인기 다중분광영상의 반사율 산출 및 평가)

  • Lee, Hwa-Seon;Seo, Won-Woo;Woo, Choongshik;Lee, Kyu-Sung
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_2
    • /
    • pp.1149-1160
    • /
    • 2019
  • In this study, two radiometric correction methods deriving reflectance from UAV multispectral image for monitoring forest vegetation were applied and evaluated. Multispectral images were obtained from a small multispectral camera having 5 spectral bands. Reflectance were derived by applying the two methods: (1) the direct method using downwelling irradiance measurement and (2) the empirical line correction method by linking a set of field reflectance measured simultaneous with the image capture. Field reflectance were obtained using a spectroradiometer during the flight and used for building the linear equation for the empirical method and for the validation of image reflectance derived. Although both methods provided the high correlations between field reflectance and image-derived reflectance, their distributions were somewhat different. While the direct method provided rather stable and consistent distribution of reflectance all over the entire image area, the empirical method showed very unstable and inconsistent reflectance distribution. The direct method would be more appropriate for relatively wide area that requires more time to acquire image and may vary in downwelling irradiance and atmospheric conditions.

The effect of flower decoration on customer's satisfaction and re-visit of a baby's first birthday (화훼장식이 돌잔치 고객의 만족도와 재방문 의도에 미치는 영향)

  • Kim, Joung Hee;Lim, Young Hee;Kim, Kiu Weon
    • FLOWER RESEARCH JOURNAL
    • /
    • v.19 no.1
    • /
    • pp.68-76
    • /
    • 2011
  • This study was conducted to investigate customer taste related to satisfaction of a baby's first birthday party and re-visit of venues. General characteristics of customers were similar in male and female or the married and the unmarried. Mainstream age of respondents was from in their 20's to 30's. Among them, the number of university graduates were the largest in education level. Theoretical model was composed with seven significant variables of design style and composition and design harmony and color sense for flower decoration, accessibility, facility, service and price, satisfaction, and intention of re-visit based on the result of analysis on these factors. Exploratory factor analysis was performed using SPSS 14.0K. Structural equation modeling(SEM) for simultaneous measure of path coefficient in all casualty of study model, measurement model of AMOS 7.0 for evaluation of validity, and reliability and factor analysis method using technical statistics, frequency analysis, and Cronbach's Alpha for data analysis were used. The result of hypothesis verification showed that design style and composition was the most significant item in satisfaction of parameter and it was followed by design harmony and color sense. While service and price had positive effect on satisfaction, accessibility and facility had no relation to it. It means that the most crucial variable was a flower decoration in planning and representation of the celebration of baby's first birthday. In conclusion, the finding of this study suggests that the effective utilization of these variables will contribute to the enhancement of satisfaction affecting improvement service and price or intention of re-visit.

Discrepancies and Validation of Ethanol Level Determination with Osmolar Gap Formula in Patients with Suspected Acute Poisoning (급성 중독환자에서 삼투압 계산식으로 추정된 에탄올 농도의 유효성 검증)

  • Jung, Haewon;Lee, Mi Jin;Cho, Jae Wan;Ahn, Jae Yun;Kim, Changho
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.17 no.2
    • /
    • pp.47-57
    • /
    • 2019
  • Purpose: Osmolar gap (OG) has been used for decades to screen for toxic alcohol levels. However, its reliability may vary due to several reasons. We validated the estimated ethanol concentration formula for patients with suspected poisoning and who visited the emergency department. We examined discrepancies in the ethanol level and patient characteristics by applying this formula when it was used to screen for intoxication due to toxic levels of alcohol. Methods: We retrospectively reviewed 153 emergency department cases to determine the measured levels of toxic ethanol ingestion and we calculated alcohol ingestion using a formula based on serum osmolality. Those patients who were subjected to simultaneous measurements of osmolality, sodium, urea, glucose, and ethanol were included in this study. Patients with exposure to other toxic alcohols (methanol, ethylene glycol, or isopropanol) or poisons that affect osmolality were excluded. OG (the measured-calculated serum osmolality) was used to determine the calculated ethanol concentration. Results: Among the 153 included cases, 114 had normal OGs (OG≤14 mOsm/kg), and 39 cases had elevated OGs (OG>14). The mean difference between the measured and estimated (calculated ethanol using OG) ethanol concentration was -9.8 mg/dL. The 95% limits of agreement were -121.1 and 101.5 mg/dL, and the correlation coefficient R was 0.7037. For the four subgroups stratified by comorbidities and poisoning, the correlation coefficients R were 0.692, 0.588, 0.835, and 0.412, respectively, and the mean differences in measurement between the measured and calculated ethanol levels were -2.4 mg/dL, -48.8 mg/dL, 9.4 mg/dL, and -4.7 mg/dL, respectively. The equation plots had wide limits of agreement. Conclusion: We found that there were some discrepancies between OGs and the calculated ethanol concentrations. Addition of a correction factor for unmeasured osmoles to the equation of the calculated serum osmolality would help mitigate these discrepancies.

CFD Analysis on the Internal Reaction in the SNCR System (SNCR 시스템 내부의 물질 반응에 관한 전산해석적 연구)

  • Koo, Seongmo;Yoo, Kyung-Seun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.25 no.1
    • /
    • pp.63-73
    • /
    • 2019
  • Numerical analysis was done to evaluate the chemical reaction and the reduction rate inside of selective non-catalytic reduction to denitrification in combustion process. The $NO_X$ reduction in selective non-catalytic reduction is converted to not only nitrogen but also nitrous oxide. Simultaneous $NO_X$ reduction and nitrous oxide generation suppressing is required in selective non-catalytic reduction because nitrous oxide influences the global warming as a greenhouse gas. The current study was performed compare the computational analysis in the same temperature and amount of NaOH, and in comparison with the previous research experiments and confirmed the reliability of the computational fluid dynamics. Additionally, controlling the addition amount of NaOH to predict the $NO_X$ reduction efficiency and nitrous oxide production. Numerical analysis was done to check the mass fraction of each material in the measurement point at the end of selective non-catalytic reduction. Experimental Value and simulation value by numerical analysis showed an error of up to 18.9% was confirmed that a generally well predicted. and it was confirmed that the widened temperature range of more than 70% $NO_X$ removal rate is increased when the addition amount of NaOH. So, large and frequent changes of the reaction temperature waste incineration facilities are expected to be effective.

Physical Model Experiment for Estimating Wave Overtopping on a Vertical Seawall under Regular Wave Conditions for On-Site Measurements (현장 월파계측을 위한 규칙파 조건에서 직립식 호안의 월파량 추정에 관한 모형실험)

  • Dong-Hoon Yoo;Young-Chan Lee;Do-Sam Kim;Kwang-Ho Lee
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.35 no.4
    • /
    • pp.75-83
    • /
    • 2023
  • Apart from implementing hardware solutions like raising the crest freeboard of coastal structures to efficiently counter wave-overtopping, there is a simultaneous requirement for software-driven disaster mitigation strategies. These tactics involve the swift and accurate dissemination of wave-overtopping information to the inland regions of coastal zones, enabling the regulation of evacuation procedures and movement. In this study, a method was proposed to estimate wave-overtopping by utilizing the temporal variation of wave heights exceeding the structure's crown level, with the aim of developing an on-site wave measurement system for providing wave-overtopping information in the field. Laboratory model experiments were conducted on vertical seawall structures to measure wave-overtopping volumes and wave runup heights under different wave conditions and structural freeboard variations. By assuming that the velocity of water inundation on the top of the structure during wave-overtopping events is equivalent to the long-wave velocity, an overtopping discharge coefficient was introduced. This coefficient was utilized to estimate the rate of wave-overtopping based on the temporal changes in wave runup heights measured at the top of the structure. Upon reasonably calculating the overtopping discharge coefficient, it was verified that the estimation of wave-overtopping could be achieved solely based on the wave runup heights.

Development of Simultaneous Analysis for Multiple Agricultural Pesticides in Raw Milk Products using GC-MS/MS (GC-MS/MS를 이용한 원유 원료 중 농약 동시분석법 확립)

  • Young Nae Choi;Yoon ho Shin;Hwangeui Cho;Jung Bok Kim
    • Journal of Food Hygiene and Safety
    • /
    • v.38 no.6
    • /
    • pp.420-429
    • /
    • 2023
  • GC-MS/MS using liquid-liquid extraction (LLE) and C18 cartridges was used to identify and quantify levels of chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin and permethrin in bulk raw milk. A calibration curve spanning 10 ng/mL to 200 ng/mL was obtained with a satisfactory correlation coefficient of 0.99. The limits of detection (LOD) and limits of quantitation (LOQ) for chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin, and permethrin in the matrix ranged from 0.06 to 1.81 ng/mL and 0.19 to 6.04 ng/mL, respectively. The recoveries of 5 pesticides from spiked samples at 37.5-125 ng/mL ranged from 86.1 to 102.1%. The measurement of uncertainty of the GC-MS/MS method for these five pesticides was developed based on the analytical process and quantification. An analysis method that is easier and faster than the method specified in the Korean food standards codes for analyzing these five pesticides in raw material milk was developed. Moreover, the analytical method for chlorpyrifos, chlorpyrifos-methyl, cypermethrin, deltamethrin, and permethrin in bulk raw milk by GC-MS/MS was established.

Low Cost and High Sensitivity Flexible Pressure Sensor Based on Graphite Paste through Lamination after O2 Plasma Surface Treatment Process (O2 플라즈마 표면 처리 공정 후 라미네이션 공정으로 제작된 흑연 페이스트 기반의 저비용 및 고감도 유연 압력 센서)

  • Nam, Hyun Jin;Kang, Cheol;Lee, Seung-Woo;Kim, Sun Woo;Park, Se-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.29 no.4
    • /
    • pp.21-27
    • /
    • 2022
  • Flexible pressure sensor was developed using low-cost conductive graphite as printed electronics. Flexible pressure sensors are attracting attention as materials to be used in future industries such as medical, games, and AI. As a result of evaluating various electromechanical properties of the printed electrode for flexible pressure sensors, it showed a constant resistance change rate in a maximum tensile rate of 20%, 30° tension/bending, and a simple pulse test. A more appropriate matrix pattern was designed by simulating the electrodes for which this verification was completed. Utilizing the Serpentine pattern, we utilized a process that allows simultaneous fabrication and encapsulation of the matrix pattern. One side of the printed graphite electrode was O2 plasma surface treated to increase adhesive strength, rotated 90 times, and two electrodes were made into one through a lamination process. As a result of pasting the matrix pattern prepared in this way to the wrist pulse position of the human body and proceeding with the actual measurement, a constant rate of resistance change was shown regardless of gender.

Simultaneous Estimation of the Fat Fraction and R2* Via T2*-Corrected 6-Echo Dixon Volumetric Interpolated Breath-hold Examination Imaging for Osteopenia and Osteoporosis Detection: Correlations with Sex, Age, and Menopause

  • Donghyun Kim;Sung Kwan Kim;Sun Joo Lee;Hye Jung Choo;Jung Won Park;Kun Yung Kim
    • Korean Journal of Radiology
    • /
    • v.20 no.6
    • /
    • pp.916-930
    • /
    • 2019
  • Objective: To investigate the relationships of T2*-corrected 6-echo Dixon volumetric interpolated breath-hold examination (VIBE) imaging-based fat fraction (FF) and R2* values with bone mineral density (BMD); determine their associations with sex, age, and menopause; and evaluate the diagnostic performance of the FF and R2* for predicting osteopenia and osteoporosis. Materials and Methods: This study included 153 subjects who had undergone magnetic resonance (MR) imaging, including MR spectroscopy (MRS) and T2*-corrected 6-echo Dixon VIBE imaging. The FF and R2* were measured at the L4 vertebra. The male and female groups were divided into two subgroups according to age or menopause. Lin's concordance and Pearson's correlation coefficients, Bland-Altman 95% limits of agreement, and the area under the curve (AUC) were calculated. Results: The correlation between the spectroscopic and 6-echo Dixon VIBE imaging-based FF values was statistically significant for both readers (pc = 0.940 [reader 1], 0.908 [reader 2]; both p < 0.001). A small measurement bias was observed for the MRS-based FF for both readers (mean difference = -0.3% [reader 1], 0.1% [reader 2]). We found a moderate negative correlation between BMD and the FF (r = -0.411 [reader 1], -0.436 [reader 2]; both p <0.001) with younger men and premenopausal women showing higher correlations. R2* and BMD were more significantly correlated in women than in men, and the highest correlation was observed in postmenopausal women (r = 0.626 [reader 1], 0.644 [reader 2]; both p < 0.001). For predicting osteopenia and osteoporosis, the FF had a higher AUC in men and R2* had a higher AUC in women. The AUC for predicting osteoporosis was highest with a combination of the FF and R2* in postmenopausal women (AUC = 0.872 [reader 1], 0.867 [reader 2]; both p < 0.001). Conclusion: The FF and R2* measured using T2*-corrected 6-echo Dixon VIBE imaging can serve as predictors of osteopenia and osteoporosis. R2* might be useful for predicting osteoporosis, especially in postmenopausal women.