• Title/Summary/Keyword: simultaneous identification

Search Result 202, Processing Time 0.024 seconds

A study on the identification of dynamic characteristics of tennis racket by acoustic intensity method (음향 인텐시터법을 이용한 테니스 라켓의 동특성에 관한 연구)

  • 오재응;이유엽;염성하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.601-610
    • /
    • 1986
  • The acoustic intensity in the very near field of a vibrating surface reveals information about the location of sound sources and sinks. A system model of tennis racket was developed from simultaneous measurement of excitation force, surface vibration and the near field sound pressure. The characteristics of structural dynamics were obtained by standard experimental modal analysis techniques while the sound radiation characteristics were determined by estimating the acoustic intensity. In this paper, the information about vibration behviour was obtained by acoustic intensity method and some, experiments for verification were carried out. Close correlation was found between experimentally determined acoustic intensity and vibration mode patterns of the tennis racket.

Development of Analytical Method for Polychlorinated Biphenyls and Organochlorine Pesticides in Air (대기 중 PCBs와 유기염소계 살충제의 정량을 위한 분석 방법 개발)

  • 최민규;여현규;김태욱;천만영;선우영
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.6
    • /
    • pp.475-485
    • /
    • 2002
  • An analytical method was investigated for the meaiiurement of polychlorinated biphenyls (PCBs) and organochlorine pesticides (OCPs) concentrations in air samples. Procedures required for column chromatographic clean up. silicagel (stage I) and gel permeation chromatography (stage II), were discussed. Identification and quantification of PCBs and OCPs were performed using a combination of gas chromatography/mass spectrometry/ selected ion monitoring. Recovery tests calculated from six samples are 68∼137% for PCBs and 58∼130% for OCPs except for endrin aldehyde. Instrumental detection limits determined for the PCBs and OCPs varied from 0.05 to 0.18 pg/m3 and from 0.71 to 16.82 pg/㎥, respectively. The method has been applied to the analysis of air samples collected at Ansung city, Kyonggi province, Korea. This method may serve as a screening protocol for the simultaneous determination of PCBs and OCPs in air.

Measurement of the Velocity Field of Rotor-Stator in a Centrifugal Turbine Pump Using PIV (PIV를 이용한 터빈펌프의 동${\cdot}$정익 속도장 계측)

  • Im, Yu-Cheong;Seo, Min-Sik;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.2 no.1 s.2
    • /
    • pp.35-42
    • /
    • 1999
  • The present experimental study is focused on the application of multi-point simultaneous measurement by PIV(Particle Image Velocimetry) to rotor-stater region within centrifugal turbine pump. Six different kinds of rpm(120, 500, 1000, 1500, 2000 and 2500) are selected as experimental condition. Optimized cross correlation identification to obtain velocity vectors is implemented with direct calculation of correlation coefficients. Fine optical setup concerned with PIV performance is arranged for the accurate PIV measurement of high-speed complex flow. The instantaneous and time-mean velocity distribution and velocity profile are represented quantitatively at the rotor and stator region.

  • PDF

A Case study of Railway logistic Information system (철도 물류 정보시스템 사례연구)

  • Kim, Young-Hoon;Kim, Kyung-Hee
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.1390-1394
    • /
    • 2009
  • In the paper We have analyzed the case study of the domestic and foreign railway logistic information systems based on the railway logistic to build the information architect basis system of real-time simultaneous. In case of domestic examples, We have analyzed the logistic information system used in Korea Railroad and the information systems of Kyungin ICD(Inland Container Depot) and Busanjin CY(Container Yard). In case of foreign example, we have analyzed the logistic information system of Japanese FRENS(Freight information network system) and the examples of freight tracking using RFID(Radio Frequency Identification). Through the above analysis, We have induced the main problems and improvement methods. We are able to build the railway-oriented information network system for the massive and efficient railway transportation.

  • PDF

A procedure for simultaneous variable selection, variable transformation and outlier identification in linear regression (선형회귀에서 변수선택, 변수변환과 이상치 탐지의 동시적 수행을 위한 절차)

  • Seo, Han Son;Yoon, Min
    • The Korean Journal of Applied Statistics
    • /
    • v.33 no.1
    • /
    • pp.1-10
    • /
    • 2020
  • We propose a unified approach to variable selection, transformation and outliers in the linear model. The procedure includes a sequential method for outlier detection and a least trimmed squares estimator for variable transformation. It uses all possible subsets regressions for model selection. Some real data analyses and the simulation results are provided to show the efficiency of the methods in the context of the correct variable selection and the fitness of the estimated model.

Volatile Flavor Components of Leek(Allium tuberosum Rottler) (부추(Allium tuberosum Rottler)의 휘발성 향기성분)

  • 김경수;박은령;조정옥;김선민;이명렬
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.27 no.4
    • /
    • pp.563-567
    • /
    • 1998
  • Volatile flavor components of edible portion of leek(Allium tuberosum R.) were extracted by SDE(simultaneous steam distillation and extraction) method using the mixture of n-pentane and diethylether (1 : 1, v/v) as an extract solvent and analyzed by GC-FID and GC/MS. Identification of the volatile flavor components was mostly based on the RI of GC and mass spectrum of GC/MS. A total of sixty-five components from leek extract were classified as 28 sulfur-containing compounds, 12 aldehydes, 9 alcohols, 4 lactones and esters, 3 acids and hydrocarbons, and 2 miscellaneous compouds. The sulfur-containing compounds were predominant in leek extract. Dimethyl disulfide(19.47%) and dimethyl trisulfide(17.38%) were the main compounds and trans-1-propenyl methyl disulfide, trans-2-hexenal and methyl allyl disulfide were also detected large amounts in leek.

  • PDF

Advanced LC Mixture Concept of Improved Response Time

  • Czanta, Markus;Tarumi, Kazuaki;Lee, Seung-Eun;Lee, Sang-Kyu;Jin, Min-Ok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.200-202
    • /
    • 2007
  • Improvement of LC mixtures can be realized by the development of new molecules in combination with the identification of advanced mixture concepts. By new high-polar single materials rotational viscosity has recently been improved significantly. Now, a new LC mixture concept for IPS and FFS technology has been identified which additionally improves switching time by up to 10%. This advanced concept is based on a more efficient usage of high-polar materials and Super Low Viscous (SLV) compounds and simultaneous reduction of less efficient materials.

  • PDF

Alternative impression technique for multiple abutments in difficult case to control

  • Jung, Bock-Young;Lee, Keun-Woo
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.1
    • /
    • pp.1-3
    • /
    • 2010
  • BACKGROUND. Even though excellent impression materials are now available for making accurate replication for hard and soft tissue, the numerous dentists have faced lots of obstacles in making simultaneous impressions of multiple abutments. CASE DESCRIPTION. This article describes a modified method of tray fabrication using auto-polymerizing acrylic resin and impression technique for multiple prepared teeth in cases with limitations and difficulties in taking dental impressions. CLINICAL IMPLICATION. This segmental tray technique has several advantages, including higher impression quality, fewer impressions, and being more comfortable for the patient and less stressful for the clinician.

Simultaneous identification of stiffness and damping based on derivatives of eigen-parameters

  • Lia, H.;Liu, J.K.;Lu, Z.R.
    • Structural Engineering and Mechanics
    • /
    • v.55 no.4
    • /
    • pp.687-702
    • /
    • 2015
  • A method based on derivatives of eigen-parameters is presented for damage detection in discrete systems with dampers. The damage is simulated by decrease on the stiffness coefficient and increase of the damping coefficient. In the forward analysis, the derivatives of eigen-parameters are derived for the discrete system. In the inverse analysis, a derivative of eigen-parameters based model updating approach is used to identify damages in frequency domain. Two numerical examples are investigated to illustrate efficiency and accuracy of the proposed method. Studies in this paper indicate that the proposed method is efficient and robust for both single and multiple damages and is insensitive to measurement noise. And satisfactory identified results can be obtained from few numbers of iterations.

Multiplex Polymerase Chain Reaction Assay for Simultaneous Detection of Candida albicans and Candida dublinensis

  • Lim, Young-Hee;Lee, Do-Hyun
    • Journal of Microbiology
    • /
    • v.40 no.2
    • /
    • pp.146-150
    • /
    • 2002
  • A multiplex polymerase chain reaction (PCR) assay was developed for the identification of two Candida species-albicans and dubliniensis. Three sets of primers were selected from different genomic sequences to specifically amplify a 516 bp fragment within the tops gene, specific for several species of the genus Candida (CCL primers); a 239 bp fragment within the $\alpha$INT1 gene, specific for Candida albicans (CAL primers); and a 175 bp fragment within the ALSD1 gene, specific for Candida dubliniensis (CDL primers). Using the primers in conjunction (multiplex PCR), we were able to detect both C. albicans and C. dubliniensis and to differentiate between them. The detection limit of the PCR assay was approximately 10 cells per milliliter of saline. Thus, this multiplex PCR assay can be applied for differentiation of C. albicans and C. dubliniensis from clinical specimens.