• Title/Summary/Keyword: simultaneous determination

Search Result 638, Processing Time 0.021 seconds

Simultaneous Determination of Seven Compounds in Samsoeum by HPLC-PDA

  • Seo, Chang-Seob;Kim, Jung-Hoon;Huang, Dae-Sun;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.18 no.1
    • /
    • pp.95-103
    • /
    • 2010
  • Objectives : To develop and validate HPLC-PDA methods for simultaneous determination of seven constituents in Samsoeum(SSE). Methods : Reverse-phase chromatography using a Gemini C18 column operating at $40^{\circ}C$, and photodiode array(PDA) detection at 254 and 280 nm, were used for quantification of the seven marker components of SSE. The mobile phase using a gradient flow consisted of two solvent systems. Solvent A was 1.0% (v/v) aqueous acetic acid and solvent B was acetonitrile with 1.0% (v/v) acetic acid. Results : Calibration curves were acquired with $r^2$>0.9997, and the relative standard deviation (RSD) values (%) for intra- and inter-day precision were less than 3.0%. The recovery rate of each compound was in the range of 100.07-112.65%, with an RSD less than 4.0%. The contents of seven compounds in SSE were 1.24-10.53 mg/g. Conclusions : The established method will be helpful to improve quality control of SSE.

Simultaneous Evaluation of Cellular Vitality and Drug Penetration in Multicellular Layers of Human Cancer Cells

  • Al-Abd Ahmed Mohammed;Lee Joo-Ho;Kuh Hyo-Jeong
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.5
    • /
    • pp.309-314
    • /
    • 2006
  • The multicellular layers(MCL) of human cancer cells is a three dimensional(3D) in vitro model for human solid tumors which has been used primarily for the assessment of avascular penetration of anti-cancer drugs. For anti-cancer drugs with penetration problem, MCL represents a good experimental model that can provide clinically relevant data. Calcein-AM is a fluorescent dye that demonstrates the cellular vitality in a graded manner in cancer cell culture system. In the present study, we evaluated the use of calcein-AM for determination of anti-proliferative activity of anti-cancer agents in MCL model of DLD-1 human colorectal cancer cells. Optical sectioning of confocal imaging was compromised with photonic attenuation and penetration barrier in the deep layers of MCL. By contrast, fluorescent measurement on the cryo-sections provided a feasible alternative. Cold pre-incubation did not enhance the calcein-AM distribution to a significant degree in MCL of DLD-1 cells. However, the simultaneous determination of drug penetration and cellular vitality appeared to be possible in drug treated MCL. In conclusion, these data suggest that calcein-AM can be used for the simultaneous determination of drug-induced anti-proliferative effect and drug penetration in MCL model.

Simultaneous Determination of Tar Color Additives in Cold Syrups by Ion Pair-high Performance Liquid Chromatography (이온쌍-고성능 액체크로마토그래피에 의한 감기약 시럽에서 타르색소 첨가물의 동시분석)

  • Jin, Jing-Yu;Huang, Hu;Lee, Beom-Gyu;Lee, Won-Jae
    • KSBB Journal
    • /
    • v.25 no.5
    • /
    • pp.459-465
    • /
    • 2010
  • A simple and efficient analytical method for the simultaneous determination of seven tar color additives was developed using ion pair high performance liquid chromatography. The conditions for HPLC analysis were as follows: column, ${\mu}$-Bondapak C18 (10 ${\mu}m$, 300 ${\times}$ 3.9 mm i.d.); gradient mobile phase, 0.025 mol/L ammonium acetate (containing 0.01 mol/L tetrabutylammonium bromide)-acetonitrile-methanol (65:25:10) as a mobile for fraction A and 0.025 mol/L ammonium acetate (containing 0.01 mol/L tetrabutylammonium bromide)-acetonitrilemethanol (40:50:10) as a mobile for fraction B; flow rate, 1.0 mL/ min; detection wavelength, 254/520/620 nm. We could attain to the detection limits as 0.01~0.05 ${\mu}$g/mL (254 nm) and 0.005~0.01 ${\mu}$g/mL (520 nm) for six red tar color additives, and 0.05 ${\mu}$g/mL (254 nm) and 0.002 ${\mu}$g/mL (620 nm) for Fast green FCF. This analytical method was applicable to determine the tar color additives contained in several commercial cold syrups.

A Study of the Potential Interference of ArC+ on the Direct Determination of Trivalent Chromium and Hexavalent Chromium Using Ion Chromatography Coupled with ICP-MS

  • Nam, Sang-Ho;Park, Young-Il;Kim, Jae-Jin;Han, Sun-Ho;Kim, Won-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.447-451
    • /
    • 2004
  • Low and high resolution inductively coupled plasma mass spectrometry (ICP-MS) coupled with ion chromatography (IC) has been investigated for speciation of Cr(III) and Cr(VI). In particular, the interference of ArC^+formed by the carbon in a sample on the simultaneous determination of Cr(III) and Cr(VI) has been studied. In chemical speciation, this study shows that quadrupole type ICP-MS with low resolution has a limitation of simultaneous determination fo chromium species if the sample contains the carbon elements. The interference problems can be solved by high resolution ICP-MS.

Simultaneous Voltammetric Determination of Mefenamic Acid and Paracetamol using Graphene Nanosheets/Nickel Oxide Nanoparticles Modified Carbon Paste Electrode

  • Naeemy, Ali;Gholam-Shahbazi, Rozhina;Mohammadi, Ali
    • Journal of Electrochemical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.282-293
    • /
    • 2017
  • A new modified carbon paste electrode (CPE) was constructed based on nickel oxide nanoparticles (NiONPs) and graphene nanosheets (Gr) for simultaneous determination of paracetamol (PCM) and mefenamic acid (MFA) in aqueous media and pharmaceutical dosage forms. NiONPs were synthesized via a simple and inexpensive technique and characterized using X-ray diffraction method. Scanning electron microscopy was used for the characterization of the morphology of modified carbon paste electrode (NiONPs/Gr/CPE). Voltammetric studies suggest that the NiONPs and Gr provide a synergistic augmentation that can increase current responses by improvement of electron transfers of these compounds on the NiONPs/Gr/CPE surface. Using cyclic voltammetry, the NiONPs/Gr/CPE showed good sensitivity and selectivity for the determination of PCM and MFA in individually or mixture standard samples in the linear range of $0.1-30{\mu}g\;mL^{-1}$. The resulted limit of detection and limit of quantification were 20 and $60ng\;mL^{-1}$ for PCM, 24 and $72ng\;mL^{-1}$ for MFA, respectively. The analytical performance of the NiONPs/Gr/CPE was evaluated for the determination of PCM and MFA in pharmaceutical dosage forms with satisfactory results.

Simultaneous Determination of Phenobarbital, Pentobarbital, Amobarbital and Secobarbital in Raw Milk via Liquid Chromatography with Electron Spray Ionization Tandem Mass Spectrometry

  • Tian, Huaixiang;Zhou, Xingxin;Chen, Chen;He, Yabin;Yu, Haiyan;Zheng, Xiaoping
    • Food Science of Animal Resources
    • /
    • v.37 no.6
    • /
    • pp.847-854
    • /
    • 2017
  • A rapid, sensitive and specific liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the simultaneous determination of four barbiturates (phenobarbital, pentobarbital, amobarbital and secobarbital) in raw milk. The barbiturates were extracted using liquid-liquid extraction, ultrasonication and centrifugation, and purified on an SPE column. Analytes were separated by HPLC on a CSH C18 column eluted using an acetonitrile-water system with a linear gradient dilution programme, and detected by MS/MS. The recoveries of the barbiturates were 85.0-113.5%, and the intra- and inter-assay RSDs were less than 9.8% and 7.3%, respectively. The limit of detection was 5 ng/mL for all four of the barbiturates. The analytical method exhibited good linearity from 10 to 1000 ng/mL; the correlation coefficient ($r^2$) was greater than 0.9950 for each barbiturate. This method was also applied to the determination of barbiturates in real milk samples and was found to be suitable for the determination of veterinary drug residues in raw milk.

Simultaneous Determination of Glucose and Ethanol of Takju by Biosensor using Dual Cathode Electrode (Dual Cathode Electrode를 이용한 바이오센서로 탁주 중의 포도당 및 에탄올의 동시 측정)

  • Park, In-Seon;Kim, Jung-Ho;Kim, Tae-Jin;Kim, Nam-Soo;Noh, Bong-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.974-980
    • /
    • 1996
  • A biosensor was prepared with dual cathode electrode and immobilized enzyme membrane. A nylon net was used for the immobilization of glucose oxidase and alcohol oxidase. The immobilized enzymes were placed on the surface of the electrode which was prepared with one anode and two cathodes as an oxygen electrode. The determination of components by the biosensor was based on the consumption of dissolved oxygen. The optimum condition of this system was 0.1 M potassium phosphate buffer solution, pH 7.5 at $35^{\circ}C$. Glucose and ethanol in takju were simultaneously determined by the biosensor. Comparing with UV-spectrophotometer and gas chromatograph for cross checking, there was a good correlation between the biosensor and the conventional methods. Biosensor with dual cathode electrode required no clarification or pretreatments. It was used for simultaneous determination of glucose and ethanol during the fermentation of takju.

  • PDF

Review of the Determination Methods for Metal Compounds with Different Occupational Exposure Limits Depending on Solubility (용해도에 따라 노출기준이 다른 금속화합물의 정량방법 고찰)

  • Park, Seung-Hyun;Ro, Jiwon;Jang, Miyeon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.87-98
    • /
    • 2020
  • Objective: The purpose of this study was to propose a sequential procedure for the simultaneous analysis of soluble and insoluble metal compounds. Methods: Methods for sampling and analyzing metal compounds such as ISO standards, NIOSH methods, HSE methods, and OSHA methods were reviewed. Results: Some metals have different OELs depending on the solubility of the compound. Therefore, we should take into account these characteristics and perform an exposure assessment. Soluble metal compounds are first extracted from the filter, and then the filter is digested by acids to analyze residual insoluble components. The extraction of soluble compounds can be completed by agitation for about 60 minutes with a leach solution (water) in a water bath at 37℃. For the analysis of insoluble compounds, the sample filter and the filtration filter remaining after the extraction of the soluble compounds are analyzed. This allows simultaneous determination of soluble and insoluble metal compounds. For hexavalent chromium compounds, soluble hexavalent chromium can first be extracted from the filter by using sulfate buffer. The insoluble hexavalent chromium remaining in the filter can then be extracted using carbonate buffer. Conclusion: Workers are often exposed to many hazardous substances with different exposure limits at industrial sites. The OELs for compounds of the same metal can be set differently depending on solubility. This study can help evaluate a worker's exposure to metal compounds by suggesting methods for the simultaneous determination of soluble and insoluble metal compounds.

Determination of Position for Reinforcement Blank at Simultaneous Forming Analysis of Automotive Front Side Member (자동차용 프론트 사이드 멤버의 일체복합성형해석 및 보강판재의 위치결정)

  • Yoon, S.J.;Kim, H.Y.;Kim, K.H.;Kim, J.J.;Song, J.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.178-182
    • /
    • 2008
  • Automotive manufacturers lay their eyes on the new manufacturing technologies because of the strengthened competition. Among them, a simultaneous forming is one of the innovative forming technologies to be able to reduce production time and cost. Several parts can be simultaneous manufactured by process, while the conventional stamping demands the same number of die sets with the number of parts. In this study, the automotive front side member was manufactured by the simultaneous forming. The position and the size of initial blank were determined by forming analysis and try-outs, and the blank movement during the forming was controlled by introducing the pilot pin.

  • PDF

First Derivative Spectrophotometric and Gas-Liquid Chromatographic Determination of Caffeine in Foods and Pharmaceuticals III. Simultaneous assay of caffeine and some antihistaminics

  • Abdel-Moety, Ezzat M.;El-Tarras, Mohamed F.;El-Zeany, Badr-Eldin A.;Kelani, Khadiga O.
    • Archives of Pharmacal Research
    • /
    • v.13 no.3
    • /
    • pp.215-220
    • /
    • 1990
  • Two different, derivative spectrophotometric and gas-liquid chromatographic, procedures for direct quantitation of caffeine and some commonly dispensed antihistaminics in bulk forms, in their laboratory prepared mmixtures and in dosage formulations, have been investigated. The limit, sensitivity reproducibility and accuracy of each method were studied for each individual drug substance and in some usual pharmaceutical formulations.

  • PDF