• Title/Summary/Keyword: simultaneous

Search Result 6,425, Processing Time 0.033 seconds

One-Step Simultaneous Immunochromatographic Strip Test for Multianalysis of Ochratoxin A and Zearalenone

  • Shim, Won-Bo;Dzantiev, Boris B.;Eremin, Sergei A.;Chung, Duck-Hwa
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.1
    • /
    • pp.83-92
    • /
    • 2009
  • Individual immunochromatographic assays (ICG) for ochratoxin A (OTA) and zearalenone (ZEA) were optimized and used in the development of a one-step simultaneous immunochromatographic assay (OS-ICG) for the rapid multianalysis of two mycotoxins in corn samples. The nitrocellulose membrane of the OS-ICG was treated with OTA-bovine serum albumin (BSA), ZEA-ovalbumin (OVA), and anti-mouse IgG in the OTA test, ZEA test, and control zones, respectively. Monoclonal antibody-gold conjugates (OTA3 MAb-gold and ZEA2C5 MAb-gold) were sprayed onto the conjugate pad. The visual detection limits were 2.5 and 5 ng/ml for OTA and ZEA, respectively, and the results were obtained within 15 min after starting the analysis. An efficient, simple, and rapid extraction method using 30% MeOH/PBS was established and validated by analyzing the corn samples spiked with OTA/ZEA mixtures (0/0, 5/10, 10/20, and $20/30\;{\mu}g/kg$). The cut-off values of the OS-ICG for the spiked corn were 5 and $10\;{\mu}g/kg$ for OTA and ZEA, respectively. Natural corn samples were analyzed by OS-ICG, direct competitive enzyme-linked immunosorbent assay (DC-ELISA), and HPLC. Results of the OS-ICG were in good agreement with those obtained by DC-ELISA and HPLC. The developed OS-ICG offers a rapid, easy-to-use, and portable analytical system and can be used as a convenient qualitative tool for the on-site simultaneous determination of OTA and ZEA in cereals, food, and agricultural products in one analytical cycle.

A Study on the Simultaneous Loading Factors for the Fatigue Design of Bridges (교량 피로설계의 동시재하계수에 관한 연구)

  • Lee, Dong Uk;Seo, Won Chan;Choi, Jae Won
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.2 s.45
    • /
    • pp.151-165
    • /
    • 2000
  • Since vehicles become large and heavy and traffic volume is increased rapidly, many fatigue damages have been reported in bridge members. In order to prevent fatigue damages of bridge members and maintain safety it is essential to perform rational fatigue check. Only one vehicle is loaded on a bridge deck for the fatigue design. But in reality it is seldom that only one vehicle passes on a bridge deck. Usually more than two vehicles are passing on a bridge deck simultaneously. Therefore, it is necessary to consider the influence of simultaneous loading for a rational fatigue design. In this study, the influence of simultaneous loading is investigated by performing stress variation analysis due to vehicle load on the basis of linear superposition method and Monte-Carlo simulation of traffic flow, and then calculating the measure of fatigue damages.

  • PDF

Simultaneous Determination of Six Components in the Traditional Herbal Medicine 'Oryeongsan' by HPLC-DAD and LC-MS/MS

  • Lee, Jiwoo;Weon, Jin Bae;Lee, Bohyoung;Yun, Bo-Ra;Eom, Min Rye;Ma, Choong Je
    • Natural Product Sciences
    • /
    • v.19 no.1
    • /
    • pp.20-27
    • /
    • 2013
  • A simple high performance liquid chromatography - diode array detector (HPLC-DAD) method has been developed and validated for simultaneous determination of the six components (cinnamic acid, cinnamaldehyde, eugenol, atractylenolide I, atractylenolide III, and ergosterol) in Oryeongsan. In addition, identification of six marker compounds was conducted by a LC-MS/MS analysis. The six compounds in Oryeongsan were separated on Shishedo $C_{18}$ column (5 ${\mu}m$, $4.6{\times}250$ mm) at a column temperature of $30^{\circ}C$. The mobile phase was a mixture of 0.1% trifluoroacetic acid (TFA) water and acetonitrile employing gradient elution at a flow rate of 1.0 mL/min. The detection wavelength was set at 205, 250, 280, and 330 nm. The developed method had good linearity ($R^2$ > 0.9997) and the limit of detection (LOD) and limit of quantification (LOQ) were observed within the ranges 0.01~0.15 and 0.05~0.45 ${\mu}g/mL$, respectively. The relative standard deviation (RSD) values of intra- and inter-day testing were indicated that less than 3% and 90.31~103.31% of accuracy. The results of recovery test were 90.56~106.72% and RSD range was measured from 0.84 to 2.95%. In conclusion, this HPLC-DAD method has been successfully applied to the simultaneous determination of six compounds in Oryeongsan samples.

A Test of the Rank Conditions in the Simultaneous Equation Models (연립방정식 모형의 계수조건 검정법 제안)

  • So, Sun-Ha;Park, You-Sung;Lee, Dong-Hee
    • Communications for Statistical Applications and Methods
    • /
    • v.16 no.1
    • /
    • pp.115-125
    • /
    • 2009
  • Simultaneous equation models, which are widely used in business and economic areas, generally consist of endogenous variables determined within models and exogenous variables externally determined and in the simultaneous equations model framework there are rank and order conditions for the model identification and the existence of unique solutions. By contrast, their estimating results have less efficiencies and furthermore do not exist, since the most estimating procedures are performed under the assumptions for rank and order conditions. We propose the new statistical test for sufficiency of the rank condition under the order condition, and show the asymptotic properties for the test. The Monte Carlo simulation studies are achieved in order to evaluate its power and to suggest the baseline for satisfying the rank conditions.

Performance characteristics of simultaneous removal equipment for paint particulate matter and VOCs generated from a spraying paint booth (입자상물질과 VOCs 동시제거 실증장치에서 자동차 페인트 부스 발생 paint aerosol과 VOCs의 동시제거 성능 특성)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Kim, Kwang-Deuk;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.161-168
    • /
    • 2016
  • The purpose of this study is to determine the performance characteristics of the paint particulate and volatile organic compounds(VOCs) simultaneous removal from the spraying paint booth in the laboratory and real site by sticky paint particulate and VOCs simultaneous removal demonstration unit. The sticky paint particulate and VOCs simultaneous removal unit is composed of the horizontal type pleated filter modules and the zig-zag type granular activated carbon packing modules. The test conditions at the laboratory are $50.15g/m^3$ of average paint aerosol concentration and 300 ppm of VOCs concentration which were same as the working conditions of spraying paint booth in the real site. But, the demonstration conditions at the real site are varied according to the working condition of spraying paint booth for the kind of passenger car bodies. The test results at the laboratory obtained that 99% of total particulate collection efficiency at 0.62 m/min of filtration velocity and 84% at 1.77 m/min of filtration velocity. The VOCs removal efficiencies are 97% at $3500hr^{-1}$ of gas hour space velocity and 59% at $10,000hr^{-1}$ of gas hour space velocity. In the real site test, the average removal efficiency of PM10 was measured to be 99.65%, the average removal efficiency of PM2.5 was 99.38%, the average removal efficiency of PM1 was 98.52%, and the average removal efficiency of VOCs was 89%.

Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Heating-main Operating Mode (난방주체 운전모드에서의 동시냉난방 열펌프 성능향상에 관한 실험적 연구)

  • Kang, Hoon;Jung, Hyen-Joon;Joo, Young-Ju;Kim, Yong-Chan;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.245-251
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the heating-main operating mode were investigated experimentally. The system adopted a variable speed compressor with four indoor units and one outdoor unit with R-410A. In the heating-main mode, the cooling capacity was lower than the design cooling capacity due to the reduction of the flow rate in the indoor unit for the cooling, with the increase of the heating capacity. To solve these problems, the performance characteristics of the simultaneous heating and cooling heat pump in the heating-main mode were investigated by varying the flow rate to the indoor unit for the cooling and the compressor rotating speed. In addition, the adequate control methods were suggested to improve the system efficiency.

Studies on the Simultaneous Determination of VNA and TSNA by GC - TEA (Gas chromatography-Thermal Energy Analyzer에 의한 휘발성 니트로소아민과 담배 특유의 니트로소아민들의 동시 분석연구)

  • Rhee, Mun-Su;Ji, Sang-Woon;Park, Yang-Su
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.15 no.2
    • /
    • pp.174-184
    • /
    • 1993
  • This is to investigate the methodology for the simultaneous determination of Wk, mk and TSNA using gas chromatography(GC) in combination with chemiluminescence detector, thermal energy analyzer(TEA) . The simultaneous analysis has been estimated by evaluating tobacco. The TEA was linked to GC equipped with non -polar SPB -5 fused silica capillary column which was introduced into the ceramic pyrolysis tube by the point of 16cm from the end of TEA. Quantification was carried out by internal standardization with WDPA after calibration of retention times and response factors with authentic nitrosoamines. It was demonstrated that WDPA was most preferable as internal standard for the simultaneous analysis. The recoveries of the internal standard were in the range of 83∼96% . Nitrosoamines in this method were detected with determination limit of 0.1ng and was made by a straight line in calibration curve by TEA response. The suitability of nitrosoamines extraction in tobacco leaf was investigated. It was most suitable to extract nitrosoamines from tobacco leaves with 0.01 M NaOH within a period of 8 hours. Thimerosal as an antibacterial agent was added to NaOH solution to prevent artifactual formation. The fractionation and the purification of nitrosoamines form alkaline extracts were conveniently performed using Extrelut multilayer column and dichloromethane. Reproducible and reliable results were obtained for the determination of nitrosamines in a relatively short time compared to previous known method. TSNA contents in burley were about 4 times higher as those in the fluecured tobacco.

  • PDF

Clinical Results Over Time for Unilateral versus Bilateral Simultaneous Short Scarf Osteotomy (편측 또는 양측을 동시에 시행한 단축 스카프 절골술의 시간 경과에 따른 임상적 결과)

  • Jeong, Changhoon;Park, Il-Kyu;Chung, Jin-Wha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.4
    • /
    • pp.154-158
    • /
    • 2019
  • Purpose: This study compared the radiographic and clinical outcomes of simultaneous bilateral short scarf osteotomy with those of unilateral short scarf osteotomy in hallux valgus patients. Materials and Methods: The authors undertook a retrospective chart and radiographic review between January 2015 and June 2017 to identify 15 patients (30 cases, group A) who underwent a simultaneous bilateral short scarf osteotomy. The patients were matched with 30 patients (30 cases, group B) with a unilateral short scarf osteotomy. No significant preoperative differences were observed between the two groups in terms of age, gender, American Orthopaedic Foot and Ankle Society (AOFAS) hallux score, and radiographic parameters. The clinical and radiographic follow-up was carried out at three months and one year. Results: Hallux valgus angles in groups A and B were reduced from the mean preoperative values of 32.5° and 34.7° to 12.5° and 12.2° at 12 months, respectively. The first-second intermetatarsal angles in groups A and B were also reduced from the mean preoperative values of 14.2° and 16.5° to 7.4° and 7.3° at 12 months, respectively. No significant inter-group differences in radiographic outcomes were observed. After three months, the patients in group A reported significantly worse mean pain and functional scores than group B. The mean AOFAS hallux score was higher in group B at the three-month follow-up, but this difference disappeared at the one-year followup. Conclusion: Simultaneous bilateral surgery can be offered to patients with a hallux valgus deformity requiring correction. On the other hand, they should be informed of the long recovery period.

Bone-added osteotome sinus floor elevation with simultaneous placement of non-submerged sand blasted with large grit and acid etched implants: a 5-year radiographic evaluation

  • Jung, Jee-Hee;Choi, Seong-Ho;Cho, Kyoo-Sung;Kim, Chang-Sung
    • Journal of Periodontal and Implant Science
    • /
    • v.40 no.2
    • /
    • pp.69-75
    • /
    • 2010
  • Purpose: Implant survival rates using a bone-added osteotome sinus floor elevation (BAOSFE) procedure with simultaneous placement of a non-submerged sand blasted with large grit and acid etched (SLA) implant are well documented at sites where native bone height is less than 5 mm. This study evaluated the clinical results of non-submerged SLA Straumann implants placed at the time of the BAOSFE procedure at sites where native bone height was less than 4 mm. Changes in graft height after the BAOSFE procedure were also assessed using radiographs for 5 years after the implant procedure. Methods: The BAOSFE procedure was performed on 4 patients with atrophic posterior maxillas with simultaneous placement of 7 non-submerged SLA implants. At least 7 standardized radiographs were obtained from each patient as follows: before surgery, immediately after implant placement, 6 months after surgery, every year for the next 3 years, and after more than 5 years had passed. Clinical and radiographic examinations were performed at every visit. Radiographic changes in graft height were calculated with respect to the implant's known length and the original sinus height. Results : All implants were stable functionally, as well as clinically and radiographically, during the follow-up. Most of the radiographic reduction in the grafted bone height occurred in the first 2 years; reduction after 2 years was slight. Conclusions: The simultaneous placement of non-submerged SLA implants using the BAOSFE procedure is a feasible treatment option for patients with severe atrophic posterior maxillas. However, the grafted bone height is reduced during the healing period, and patients must be selected with care.

Contralateral Incidence of Pediatric Inguinal Hernia and Hydrocele after Unilateral Operation (소아 서혜부 탈장과 음낭수종에서 예방적 반대측 수술의 필요성에 대한 연구)

  • Han, Young-Jin;Nam, So-Hyun;Kim, Dae-Yeon;Kim, Seong-Chul;Kim, In-Koo
    • Advances in pediatric surgery
    • /
    • v.14 no.1
    • /
    • pp.48-57
    • /
    • 2008
  • Prophylactic contralateral exploration in unilateral inguinal hernia repair is still controversial. The purpose of this study is to analyze the contralateral incidence of hernia and to verify the necessity of the simultaneous contralateral exploration. Infants and children operated on for inguinal hernia or hydrocele at the Department of Pediatric Surgery of Asan Medical Center from January 1996 to December 2005 were analyzed retrospectively. A total of 383 patients (9.8 %) out of 3,925 patients underwent a simultaneous bilateral operation. A total of 222 patients (6.2 %) out of 3,542 patients underwent a secondary metachronous contralateral operation after primary unilateral inguinal hernia or hydrocele repair. Because simultaneous bilateral operation cases included true bilateral inguinal hernia or hydrocele, and unilateral hernia and simultaneous contralateral exploration, bilateral incidence of inguinal hernia and hydrocele could be maximally considered as 15.4% (605 patients). Therefore, the prophylactic contralateral exploration in unilateral inguinal hernia or hydrocele should be determined carefully in considering history and physical examination of the patients, and postoperative complications.

  • PDF