• Title/Summary/Keyword: simultaneous

Search Result 6,411, Processing Time 0.031 seconds

Triangular units based method for simultaneous optimizations of planar trusses

  • Mortazavi, Ali;Togan, Vedat
    • Advances in Computational Design
    • /
    • v.2 no.3
    • /
    • pp.195-210
    • /
    • 2017
  • Simultaneous optimization of trusses which concurrently takes into account design variables related to the size, shape and topology of the structure is recognized as highly complex optimization problems. In this class of optimization problems, it is possible to encounter several unstable mechanisms throughout the solution process. However, to obtain a feasible solution, these unstable mechanisms somehow should be rejected from the set of candidate solutions. This study proposes triangular unit based method (TUBM) instead of ground structure method, which is conventionally used in the topology optimization, to decrease the complexity of search space of simultaneous optimization of the planar truss structures. TUBM considers stability of the triangular units for 2 dimensional truss systems. In addition, integrated particle swarm optimizer (iPSO) strengthened with robust technique so called improved fly-back mechanism is employed as the optimizer tool to obtain the solution for these class of problems. The results obtained in this study show the applicability and efficiency of the TUBM combined with iPSO for the simultaneous optimization of planar truss structures.

Inverter for Induction Heating using Simultaneous Dual-Frequency Method (동시 이중주파수 구동을 이용한 유도가열용 인버터)

  • Shin, Woo-Seok;Park, Hee-Chang
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.554-560
    • /
    • 2011
  • Single-frequency induction heating equipment caused by a hardening heat treatment process of the double investment in the issue and allow the heat treatment process in order to shorten the time from one process to work simultaneously on two kinds of processes that allow Simultaneous Dual Frequency(SDF) drive scheme technology are described. In this paper, we propose a dual way to drive a simultaneous dual-frequency drive scheme has been implemented. Through simulations and experiments, we can obtain the validity of the proposed inverter for dual-frequency control and power control.

How Does the Presentation Mode of Product Information Affect Product Evaluation? : The Mediation of Construal Level and the Moderation of Response Time

  • Cho, Hyun Young
    • International Journal of Contents
    • /
    • v.16 no.1
    • /
    • pp.44-56
    • /
    • 2020
  • The purpose of this study was to examine how the presentation mode (sequential- vs. simultaneous-mode) of information influences its evaluation. Three experiments revealed the interaction effect between the presentation mode and the valence of the product information. When respondents read about the positive aspects of the product, the evaluation was higher in the simultaneous presentation mode than in the sequential presentation mode. For negative product information, respondents' evaluation was higher in the sequential presentation mode than in the simultaneous presentation mode. The simultaneous presentation mode intensified the impact of the information valence on evaluation. This study proposed that the sequential and the simultaneous presentation modes prime high and low construal levels, respectively. The mediation analysis provides support for such a prediction. Finally, the mediating effect of construal levels in evaluation was shown to disappear when respondents focused on the product information for a longer duration, while the mediation effect remained when the response time was short.

EXPANSION THEORY FOR THE TWO-SIDED BEST SIMULTANEOUS APPROXIMATIONS

  • RHEE, HYANG JOO
    • Journal of applied mathematics & informatics
    • /
    • v.39 no.3_4
    • /
    • pp.437-442
    • /
    • 2021
  • In this paper, we study the characterizations of two-sided best simultaneous approximations for ℓ-tuple subset from a closed convex subset of ℝm with ℓm1(w)-norm. Main fact is, k* is a two-sided best simultaneous approximation to F from K if and only if there exist f1, …, fp in F, for any k ∈ K $${\mid}{\sum\limits_{i=1}^{m}}sgn(f_{ji}-k^*_i)k_iw_i{\mid}{\leq}\;{\sum\limits_{i{\in}Z(f_j-k^*)}}\;{\mid}k_i{\mid}w_i$$ for each j = 1, …, p and 𝐰 ∈ W.

TWO-SIDED BEST SIMULTANEOUS APPROXIMATION

  • Rhee, Hyang Joo
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.23 no.4
    • /
    • pp.705-710
    • /
    • 2010
  • Let $C_1(X)$ be a normed linear space over ${\mathbb{R}}^m$, and S be an n-dimensional subspace of $C_1(X)$ with spaned by {$s_1,{\cdots},s_n$}. For each ${\ell}$- tuple vectors F in $C_1(X)$, the two-sided best simultaneous approximation problem is $$\min_{s{\in}S}\;\max\limits_{i=1}^\ell\{{\parallel}f_i-s{\parallel}_1\}$$. A $s{\in}S$ attaining the above minimum is called a two-sided best simultaneous approximation or a Chebyshev center for $F=\{f_1,{\cdots},f_{\ell}\}$ from S. This paper is concerned with algorithm for calculating two-sided best simultaneous approximation, in the case of continuous functions.

POSTOPERATIVE STABILITY OF FIXATION WITH ABSORBABLES IN SIMULTANEOUS MAXILLOMANDIBULAR ORTHOGNATHIC SURGERY (상하악 동시 악교정수술에서 흡수성 고정판을 이용한 골편고정시 술후 안정성에 대한 연구)

  • Park, Jung-Min;Park, Young-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.2
    • /
    • pp.126-131
    • /
    • 2010
  • Objectives: This study is aimed to determine any differences in the postoperative stability between absorbable and titanium plate systems for fixation in orthognathic surgery with simultaneous maxillomandibular procedures especially including maxillary posterior impaction and advancement. Study Design: Forty patients with dentofacial deformities were randomly assigned into titanium (4 males and 6 females) and absorbable (17 males and 13 females) fixation group. All patients had undergone surgical alterations of maxilla with posterior impaction and advancement. A comparison study of the change in the maxillary position after the simultaneous surgery was performed with 1-day, 6-months postoperative lateral cephalograms compared to preoperative lateral cephalogram by tracing. Wilcoxon rank sum test was used for statistical analysis. Result: The position of the maxilla was stable after surgery and was not changed significantly from 1 day to 6 month after the simultaneous maxillomandibular surgery both in the experimental (absorbable plates) and control (titanium plates). Conclusion: This study suggests that application of absorable plating system in the fixation of maxillary segment in the simultaneous maxillomandibular procedures, leads to a predictable short-term postoperative skeletal stability comparable to the titanium plating system. Long term follow-up and further studies will be needed.

A Survey of Doctors' Awareness of Simultaneous Vaccination (예방접종 동시접종에 대한 접종의사의 인식 조사)

  • Lee, Hojun;Seo, Hyun Seok;Choi, Seok Won;Kim, Ji Sung;Kim, Eun Eui;Kim, Cheol Am;Son, Byeong Hee;Lee, Kyun Woo
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.2
    • /
    • pp.69-74
    • /
    • 2015
  • Purpose: In this study, doctors were surveyed with a questionnaire to determine whether they performed simultaneous vaccination and whether there were any concerns about safety or anxiety. The purpose of this study was to determine any problems associated with doctors readily performing simultaneous vaccination. Methods: A trained surveyor visited 241 doctors from every institution registered with the National Immunization Program (NIP) located within six districts (gu) in the City of Busan (Dongnae-gu, Geumjeong-gu, Yeonje-gu, Suyeong-gu, Busanjin-gu, Haeundae-gu); a total of 155 (64%) valid responses were obtained. Results: Of the 155 respondents, 144 (93%) were already performing simultaneous immunizations and 141 (91%) had a positive view of the practice. However, among the 144 doctors performing simultaneous immunizations, 67 (47%) were not confident about its safety; side effects were seen after simultaneous immunization by 86 doctors, 35 (41%) of whom believed that the frequency or possibility of side effects in simultaneous immunizations was higher than that in sequential immunizations. Conclusions: The use of simultaneous immunization is expanding quickly. However, among the doctors performing simultaneous immunizations, a high percentage had concerns over its unproven safety and potential side effects, indicating the need for academic societies or government institutions to present evidence to address such concerns.

Simultaneous Localization and Mapping of Mobile Robot using Digital Magnetic Compass and Ultrasonic Sensors (전자 나침반과 초음파 센서를 이용한 이동 로봇의 Simultaneous Localization and Mapping)

  • Kim, Ho-Duck;Seo, Sang-Wook;Jang, In-Hun;Sim, Kwee-Bo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.17 no.4
    • /
    • pp.506-510
    • /
    • 2007
  • Digital Magnetic Compass(DMC) has a robust feature against interference in the indoor environment better than compass which is easily disturbed by electromagnetic sources or large ferromagnetic structures. Ultrasonic Sensors are cheap and can give relatively accurate range readings. So they ate used in Simultaneous Localization and Mapping(SLAM). In this paper, we study the Simultaneous Localization and Mapping(SLAM) of mobile robot in the indoor environment with Digital Magnetic Compass and Ultrasonic Sensors. Autonomous mobile robot is aware of robot's moving direction and position by the restricted data. Also robot must localize as quickly as possible. And in the moving of the mobile robot, the mobile robot must acquire a map of its environment. As application for the Simultaneous Localization and Mapping(SLAM) on the autonomous mobile robot system, robot can find the localization and the mapping and can solve the Kid Napping situation for itself. Especially, in the Kid Napping situation, autonomous mobile robot use Ultrasonic sensors and Digital Magnetic Compass(DMC)'s data for moving. The robot is aware of accurate location By using Digital Magnetic Compass(DMC).

A Study on Simultaneous Load Factor of Intelligent Electric Power Reduction System in Korea (한국의 지능형 전력동시부하율 저감시스템에 관한 연구)

  • Kim, Tae-Sung;Lee, Jong-Hwan
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.35 no.1
    • /
    • pp.24-31
    • /
    • 2012
  • This study is designed to predict the overall electric power load, to apply the method of time sharing and to reduce simultaneous load factor of electric power when authorized by user entering demand plans and using schedules into the user's interface for a certain period of time. This is about smart grid, which reduces electric power load through simultaneous load factor of electric power reduction system supervision agent. Also, this study has the following characteristics. First, it is the user interface which enables authorized users to enter and send/receive such data as demand plan and using schedule for a certain period of time. Second, it is the database server, which collects, classifies, analyzes, saves and manages demand forecast data for a certain period of time. Third, is the simultaneous load factor of electric power control agent, which controls usage of electric power by getting control signal, which is intended to reduce the simultaneous load factor of electric power by the use of the time sharing control system, form the user interface, which also integrate and compare the data which were gained from the interface and the demand forecast data of the certain period of time.

Simultaneous Implant Installation Using the Block Bone Graft (치조열에서 블록 골이식을 이용한 임플란트 동시 매식법)

  • Choung Pill-Hoon;Kang Nara;Hong Jong-Rak
    • Korean Journal of Cleft Lip And Palate
    • /
    • v.5 no.2
    • /
    • pp.85-93
    • /
    • 2002
  • Simultaneous implant installation with bone graft was performed in 15 cases. Four cases were cleft alveolus patients. 56 implants were placed immediately with block bone grafts. 2 cases were cranial bone grafts and the others were iliac bone grafts. Three of 56 implants were lost(94.6% Survival rate). One of three was cleft alveolus case. The cleft alveolus patients with simultaneous implants installation showed functional and esthetic results without infraocclusion and positional changes. Bergland index was considered to be type I after 12 months later. Immediate implant installation with bone graft is one of choice of treatment in closing cleft alveolus hoping simultaneous implant installation could be related with function which might result in less resorption of graft. Functional and esthetic results are satisfaction ; there was no infraocclusion and positional changes.

  • PDF