• 제목/요약/키워드: simulated body fluid

검색결과 122건 처리시간 0.049초

입자법을 이용한 파랑중 부유체 운동의 수치시뮬레이션 (Numerical Simulation of Floating Body Motion in Surface Waves by use of a Particle Method)

  • 정성준;박종천;이병혁;류민철;김용수
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.403-406
    • /
    • 2006
  • A particle method recognized as one of gridless methods has been developed to investigate the nonlinear free-surface motions interacting to the structures. The method is more feasible and effective than convectional grid methods in order to solve the flow field with complicated boundary shapes. In the present study, breaking waves with a floating body are simulated to investigate fluid-structure interactions in the coastal zone.

  • PDF

공기 저항과 바람의 영향을 고려한 대기에서의 유체입자의 3차원 궤적 (Three-Dimensional Trajectory of a Fluid Particle in Air with Wind Effects and Air Resistance)

  • 이동렬
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권4호
    • /
    • pp.797-808
    • /
    • 2001
  • Three-dimensional trajectory of fluid particle is simulated by a particle motion, which is able to examine the influences of changes in the several parameters. To calculate the trajectory of a particle, the Runge-Kutta method was utilized. The use of a projectile of particles for the trajectory of liquid jet has been shown to be useful to estimate the influence of different operating parameters such as best particle diameter, density of liquid body, initial take-off velocity, wind velocity, cross wind velocity, take-off angle, and base angle for a released flow from the nozzle. The results give the trajectories of various types of particle of body and at different elevations, base angles, wind velocities and densities of liquid body. The trajectories in a vacuum show that air resistances decreases both the distance and the maximum height of a projectile, and also explain that the termination time is also reduced in air. In addition, the maximum distance in the x direction was obtained with take-off angles from 30 degrees to 45 degrees in still air and the projectile of particles was highly effected by wind and cross wind. Clearly, a particle has to be so positioned as to take the optimum possible advantage of the wind if the maximum distances is requested. The wind astern increased the maximum distances of x direction compared with the wind ahead. Finally, it is possible to optimize the design of pump by using these results.

  • PDF

Biocompatibility and Mechanical Performance of Ni-Ti

  • Kim, J.H.;Choi, Y.C.;Kim, H.S.;Hong, S.I.
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part2
    • /
    • pp.1257-1258
    • /
    • 2006
  • Biomimetic apatite deposition behaviors and mechanical performance for as-rolled and annealed Ni-Ti plates were investigated . A good biomimetic apatite formation and excellent mechanical performance of Ni-Ti suggests that Ni-Ti can be an excellent candidate material as orthopedic implants.

  • PDF

Hydroxyapatite Bioceramics의 생체 친화성에 관한 연구 : (II) 인공 체액에서의 거동 및 생체 친화성 (Study on the Biocompatibility of Hydroxyapatite Bioceramics : (II) Behavior in Simulated Body Fluid and Biocompatibility)

  • 김양수;고형열;송종택;최상흘
    • 한국세라믹학회지
    • /
    • 제27권6호
    • /
    • pp.721-728
    • /
    • 1990
  • Hydroxyapatite powders were synthesized with Ca/P=1.67 and pH=11 by precipitaton method, after characterization of these specimen, behavior in Ringer's solution and biocompatibility of hydroxyapatite, such as cytotoxity test and implantation test, were investigated. The hydroxyapatite ceramics had structural stability in Ringer's solution, and hydroxyapatite ceramics did not prevent cell growing and exhibit any cytotoxic effects. In implantation of hydroxyapatite ceramics into muscle under abdome of guinea pig, hydroxyapatite ceramics did not show any symptom of rejection for cellular texture.

  • PDF

로터리 댐퍼의 토오크 특성에 관한 연구 (A Study on the Torque Characteristics of Rotary Dampers)

  • 이춘태
    • 드라이브 ㆍ 컨트롤
    • /
    • 제16권4호
    • /
    • pp.87-92
    • /
    • 2019
  • Rotary dampers are damping devices which provide high resistance to shaft rotation. Rotary dampers are being used in various areas to enable the gentle opening and closing of the rotation motion relative to home furniture, industry machinery and automotive parts. Rotary dampers can be installed directly at the rotating point of a various part and can achieve uniform, gentle movement which increases quality and value of products. And generally, the silicone fluid is used as the damping medium because of its stable viscous properties. The movement of these little decelerators can be achieved with a high viscosity of working fluid and throttles installed in the body of the rotary damper. The damping force can be achieved clockwise, anti-clockwise or in both directions according to the structure of the orifices or throttles. In this paper, the torque performances of the rotary damper containing air in the working fluid were studied. For this purpose, the torque characteristic of the rotary damper according to the variation of various operating conditions such as clearance of leakage, dimensions of groove orifice, content ratio of air, etc., were simulated with AMEsim software.

Fabrication and Cell Culturing on Carbon Nanofibers/Nanoparticles Reinforced Membranes for Bone-Tissue Regeneration

  • Deng, Xu Liang;Yang, Xiao Ping
    • Carbon letters
    • /
    • 제13권3호
    • /
    • pp.139-150
    • /
    • 2012
  • Poly-L-lactic acid (PLLA), PLLA/hydroxyapatite (HA), PLLA/multiwalled carbon nanotubes (MWNTs)/HA, PLLA/trifluoroethanol (TFE), PLLA/gelatin, and carbon nanofibers (CNFs)/${\beta}$-tricalcium phosphate (${\beta}$-TCP) composite membranes (scaffolds) were fabricated by electrospinning and their morphologies, and mechanical properties were characterized for use in bone tissue regeneration/guided tissue regeneration. MWNTs and HA nanoparticles were well distributed in the membranes and the degradation characteristics were improved. PLLA/MWNTs/HA membranes enhanced the adhesion and proliferation of periodontal ligament cells (PDLCs) by 30% and inhibited the adhesion of gingival epithelial cells by 30%. Osteoblast-like MG-63 cells on the randomly fiber oriented PLLA/TEF membrane showed irregular forms, while the cells exhibited shuttle-like shapes on the parallel fiber oriented membrane. Classical supersaturated simulated body fluids were modified by $CO_2$ bubbling and applied to promote the biomineralization of the PLLA/gelatin membrane; this resulted in predictions of bone bonding bioactivity of the substrates. The ${\beta}$-TCP membranes exhibit good biocompatibility, have an effect on PDLC growth comparable to that of pure CNF membrane, and can be applied as scaffolds for bone tissue regeneration.

생체유사액 침적에 따른 표면 처리된 titanium plate에 아파타이트 형성 (Apatite formation on the surface treated-titanium plate in a simulated body fluid)

  • 이창훈;진형호;박홍채;윤석영
    • 한국결정성장학회지
    • /
    • 제19권1호
    • /
    • pp.19-24
    • /
    • 2009
  • 생체모방법을 이용하여 표면 처리된 titanium plates 표면에 아파타이트 형성에 관하여 조사하였다. 표면 처리방법으로는 우선, titanium plate 표면에 titanium oxide층을 형성시키기 위하여 열처리온도를 $400^{\circ}C$, $600^{\circ}C$, 그리고 $800^{\circ}C$에서 전기로에서 5시간 유지하였으며, 열처리된 titanium plates 1 M를 수산화나트늄 용액에 침전시켜 표면을 화학적으로 처리하였다. 생체모방법으로 titanium plates 표면에 아파타이트를 형성시키기 위하여 표면처리된 titanium plates 를 Kokubo's recipe에 의하여 제조된 생체유사액(SBF)에 침적시켰다. SBF 용액에 1주와 3주기간 동안 침적시킨 후, 표면처리를 달리한 titanium plates 표면에 형성된 코팅층을 서로 비교 분석하였다.

의사체액에서 수산화아파타이트의 결정성에 따른 분해거동 (Degradation Behavior of Hydroxyapatite with Different Crystallinity in Simulated Body Fluid Solution)

  • 진형호;김동현;김태완;박홍채;윤석영
    • 한국재료학회지
    • /
    • 제21권6호
    • /
    • pp.347-351
    • /
    • 2011
  • Hydroxyapatite (HAp) powders with different crystallinities were synthesized at various calcination temperatures through the co-precipitation of $Ca(OH)_2$ and $H_3PO_4$. The degradation behavior of these HAp powders with different crystallinities was assessed in a simulated body fluid solution (SBF) for 8 weeks. Below $800^{\circ}C$, the powders were nonstochiometric HAp, and the single HAp phase was successfully synthesized at $800^{\circ}C$. The degree of crystallinity of the HAp powders increased with an increasing calcination temperature and varied in a range from 39.6% to 92.5%. In the low crystallinity HAp powders, the Ca and P ion concentrations of the SBF solution increased with an increasing soaking time, which indicated that the low crystallinity HAp degraded in the SBF solution. The mass of the HAp powders linearly decreased with respect to the soaking time, and the mass loss was higher at lower crystallinities. The mass loss ranged from 0.8% to 13.2% after 8 weeks. The crystallinity of the HAp powders increased with an increasing soaking time up to 4 weeks and then decreased because of HAp degradation. The pH of the SBF solution did not change much throughout the course of these experiments. These results suggested that the crystallinity of HAp can be used to control the degradation.

이온성 고분자를 이용한 나트륨 섭취 감소 효과 (Effect of Ionic Polymers on Sodium Intake Reduction)

  • 박세현;이영주;이종휘
    • 폴리머
    • /
    • 제37권4호
    • /
    • pp.533-538
    • /
    • 2013
  • 염화나트륨은 우리 몸의 체액에 존재하며, 혈액 속에 약 0.9 wt%의 농도로 존재하여 삼투압을 유지하는 중요한 역할을 하고 있다. 그러나 사람들이 섭취하는 소금의 양은 증가하는 추세이며, 과량 섭취로 인해 고혈압 등의 원인이 되기도 한다. 본 연구에서는 생체적합성 이온성 고분자들의 특정 반대이온을 칼슘과 칼륨으로 치환시켜 나트륨 이온과의 이온교환을 통해 고분자에 나트륨이 흡착되어 대변으로 배출시킬 수 있는지를 in vitro 실험과 in vivo 실험을 통해 연구하였다. 조사된 고분자들 중 칼슘과 칼륨의 폴리스티렌설폰산, 칼슘 치환된 카라기난과 타마린드가 우수한 나트륨 치환 능력을 보유하고 있음을 확인하였고, 체온과 인공위액 및 인공장액의 조건에서도 나트륨 치환능을 유지하는 것을 확인하였다. 이러한 고분자들의 난용성 특징을 통해 구강 내에서는 맛의 변화를 주지 않으면서 나트륨을 흡착해 배설하는 메카니즘을 나트륨 과다 섭취에 따른 문제 해결을 위해 활용할 수 있을 것으로 사료된다.

마이크로파에 의해 합성된 β-TCP/PLGA 복합체의 의사체액에서의 분해 거동 (In vitro Degradation of β-TCP/PLGA Composites Prepared with Microwave Energy in Simulated Body Fluid)

  • 진형호;민상호;현용택;박홍채;윤석영
    • 한국재료학회지
    • /
    • 제16권11호
    • /
    • pp.676-680
    • /
    • 2006
  • The biodegradable $\beta$-tricalcium phosphate ($\beta$-TCP)/poly(lactide-co-glycolide) (PLGA) composites were synthesized by in situ polymerization with microwave energy. The degradation behavior of $\beta$-TCP/PLGA composite was investigated by soaking in simulated body fluid (SBF) for 4 weeks. The molecular weight of the $\beta$-TCP/PLGA composites decreased with soaking time until week 2, whereas the loss rate of molecular weight reduced after week 2. The incubation time was needed for the degradation of the $\beta$-TCP, indicating that the $\beta$-TCP should be detached from the PLGA matrix and then degraded into SBF solution. The studies of mass loss of the composites with the soaking time revealed that the degradation behavior of PLGA would be processed with the transformation from the polymer to the oligomer followed by the degradation. Morphological changes, whisker-like, due to transformation and degradation of polymer in the composites were observed after week 2. On the basis of the results, it found that the degradation behavior of $\beta$-TCP/PLGA composites was influenced by the $\beta$-TCP content in the composites and the degradation rate of the composites could be controlled by the initial molecular weight of PLGA in the composites.