• Title/Summary/Keyword: simple procedure

Search Result 1,836, Processing Time 0.033 seconds

X-ray Image Processing for the Korea Red Ginseng Inner Hole Detection (II) - Results of inner hole detection - (홍삼 내공검출을 위한 X-선 영상처리기술 (II) - 내공검출결과 -)

  • 손재룡;최규홍;이강진;최동수;김기영
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.45-52
    • /
    • 2003
  • Red ginsengs are inspected manually by examining those in the dark room with back light illumination. Manual inspection is often influenced by physical condition of inspectors. Sometimes. the best grade, heaven. has some inner holes though it was inspected by a specialist. In order to resolve this problem, this study was performed to develop image processing algorithm to detect the inner holes in the x-ray image of ginseng. Because of little gray value difference between background and ginseng in the image. simple thresholding method was not appropriate. Modified watershed algorithm was used to differentiate the inner holes from background and normal ginseng body. Inner hole edge region detected by watershed algorithm consists of many number of blobs including normal portions. With line profile analysis with scanning one line at a time beginning the starting point. it shelved two peaks both ends representing extracting each blobs. in which setting threshold value as of lower peak value enabled us to obtain inner hole image. Once this procedure has to be done till the finishing point it is completing inner hole detection for one blob. Thus. conducting ail blobs by this procedure is completing inner detection of one whole ginseng. Detection results of the inner holes fer various size of red ginsengs were good even though there was small detection variation. 6.2%. according to position of x-rat tube.

Understanding and trends of esthetic treatment in prosthodontics : IPS e.max (심미보철 치료의 경향과 이해 : part 1. IPS e.max)

  • Kang, Jung-In;Heo, Yu-Ri;Lee, Myeong-Seon;Son, Mee-Kyoung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.4
    • /
    • pp.447-452
    • /
    • 2014
  • With the increase of esthetic demands, most patients want to have restorations which are not only functional but also esthetic. For the esthetic restoration, many ceramic systems have been introduced and applied in dentistry. Among those ceramic restorations, IPS e.max system composed of lithium disilicate glass ceramic is one of the most commonly used systems because it has strength and esthetic characteristics. IPS e.max system is divided into IPS e.max Press and IPS e.max CAD according to the manufacturing methods. IPS e.max Press is fabricated through heat-pressed technique with ceramic ingot, which is very simple. The restorations which are made using IPS e.max system can apply to 3 units restoration for the anterior teeth and premolar, and single posterior tooth restoration. Cementation is one of the most important clinic procedure for the longevity of the restorations. All ceramics are bonded by resin cements, it is classified into three groups including adhesive, self-adhesive, and conventional. Variolink N, which is an adhesive resin cement and manufactured by same company with IPS e.max, is recommended for the bonding of IPS e.max restoration. Conventional and self-adhesive resin cement is also available. The aim of this review article is to provide the understanding of material properties, production procedure and clinical application of IPS e.max system.

Joint Estimation Schemes of Carrier and Sampling Frequency Offsets for MB-OFDM UWB Systems (MB-OFDM UWB 시스템을 위한 반송파 및 샘플링 주파수 오프셋 결합 추정 기법)

  • Cho, Chang-Hoon;Yang, Suck-Chel;Shin, Yo-An
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.10C
    • /
    • pp.965-975
    • /
    • 2005
  • In this paper, we propose and evaluate joint carrier and sampling frequency offset estimation schemes based on the channel estimation sequences in PLCP (Physical Layer Convergence Procedure) preamble for the proper and effcient synchronization of the MB-OFDM WB (Multi-Band Orthogonal Frequency Division Multiplexing Ultra Wide Band) systems which have recently drawn explosive attention for future W-PAN (Wireless Personal Area Network) applications. In the joint estimation schemes, we first estimate the sampling frequency offset, and then estimate the carrier frequency offset using the estimated sampling frequency offset. Moreover, to improve the reliability of the estimated offset values, each process uses a combination scheme based on weighting factors. Simulation results using IEEE 802.15 Task Group 3a UWB channel models reveal that the estimation scheme using the simple weighting factors based on easily-measurable received signal power of each sub-channel shows favorably comparable performance to the ideal scheme using the weighting factors based on the perfectly-estimated frequency response of the channel.

Inhalational Deep Sedation Using Sevoflurane in Pediatric Dental Patients (소아치과 환자에서의 세보플루란을 이용한 흡입 심진정법)

  • Lee, Won-Ho;Kim, Young-Jae;Jang, Ki-Taeg;Lee, Sang-Hoon;Seo, Kwang-Suk;Kim, Hyun-Jeong;Yum, Kwang-Won;Park, Chang-Joo
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.4 no.2 s.7
    • /
    • pp.90-95
    • /
    • 2004
  • Background: Sevoflurane, a rotatively new inhalational anesthetic. has non-pungent odor and is less reluctant to pediatric patients. The purpose of this study is to examine the feasibility of sevoflurane in inhalational sedation instead of the nitrous oxide for short and simple dental treatments in pediatric patients. Patients and Methods: Fifteen healthy children, whose dental treatment was abandoned due to their little or no cooperation, were selected with their caregivers' written permission. Deep sedation was induced and maintained with oxygen and 1-5% sevoflufane via specially designed nasal mask. Blood pressure, heart rate, oxygen saturation, and electrocardiogram were monitored at 3-nin interval. A dental anesthesiologist, who was independent of dental treatments, was wholly responsible for the sedation procedure. Post-sedation complications and operator's and caregiver's acceptability of this type of inhalational sedation were also investigated. Results: The systolic and diastolic blood pressure, heart rate, and oxygen saturation was significantly depressed during the deep sedation using sevoflurane (P < 0.05). No severe post-sedation complications were found, however, bradycardia was reported in 3 patients. Almost all the operators and caregivers answered that they would adapt this sedation procedure again if possible. Conclusion: In this study, inhalational deep sedation using sevoflurane for dental treatments was found to be very useful. Furthermore, the application of sevoflurane to conscious sedation for pediatric and adult dental patients should be added.

  • PDF

Inverse model for pullout determination of steel fibers

  • Kozar, Ivica;Malic, Neira Toric;Rukavina, Tea
    • Coupled systems mechanics
    • /
    • v.7 no.2
    • /
    • pp.197-209
    • /
    • 2018
  • Fiber-reinforced concrete (FRC) is a material with increasing application in civil engineering. Here it is assumed that the material consists of a great number of rather small fibers embedded into the concrete matrix. It would be advantageous to predict the mechanical properties of FRC using nondestructive testing; unfortunately, many testing methods for concrete are not applicable to FRC. In addition, design methods for FRC are either inaccurate or complicated. In three-point bending tests of FRC prisms, it has been observed that fiber reinforcement does not break but simply pulls out during specimen failure. Following that observation, this work is based on an assumption that the main components of a simple and rather accurate FRC model are mechanical properties of the concrete matrix and fiber pullout force. Properties of the concrete matrix could be determined from measurements on samples taken during concrete production, and fiber pullout force could be measured on samples with individual fibers embedded into concrete. However, there is no clear relationship between measurements on individual samples of concrete matrix with a single fiber and properties of the produced FRC. This work presents an inverse model for FRC that establishes a relation between parameters measured on individual material samples and properties of a structure made of the composite material. However, a deterministic relationship is clearly not possible since only a single beam specimen of 60 cm could easily contain over 100000 fibers. Our inverse model assumes that the probability density function of individual fiber properties is known, and that the global sample load-displacement curve is obtained from the experiment. Thus, each fiber is stochastically characterized and accordingly parameterized. A relationship between fiber parameters and global load-displacement response, the so-called forward model, is established. From the forward model, based on Levenberg-Marquardt procedure, the inverse model is formulated and successfully applied.

Development of a Prototype S-100 Data Model (프로토타입 해사데이터 모델 개발)

  • Kang, Namseon;Son, Gumjun;Jeong, Yujun;Kim, Hyejin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.5
    • /
    • pp.527-536
    • /
    • 2018
  • In this paper, we developed a prototype model accident management SMART-Navigation project. In order to develop a prototype model, we analyzed the status of maritime data exchange standard and procedure. We developed accident management prototype application schema, feature catalog and portrayal catalog in accordance with S-100 standard data model development procedure by collecting requirements related services and referring to related standards. In order to verify accident management prototype model, we test data set based on Gwang-yang Port. The prototype model and test data verified verification software, and it was confirmed that the designated symbol was displayed at the correct position through the S-100 simple viewer.

Nonlinea Perturbation Method for Dynamic Structural Redesign (동적(動的) 구조(構造) 재설계(再說計)를 위한 비선형(非線形) 섭동법(攝動法))

  • Kyu-Nam,Cho
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.26 no.1
    • /
    • pp.39-45
    • /
    • 1989
  • Many mechanical systems including ships and/or offshore structures have poor dynamic response characteristics such as undesirable natural frequencies and undesirable mode shapes. It is mandatory to redesign the structure. In this paper a procedure for the dynamic redesign of an undamped structural system is presented. The method which uses a penalty function with a penalty term containing error in equilibrium for a given vibration mode may have a shortcoming. This method includes unconstrained eigenvector degrees of freedom as unknowns. In the work developed here, only constrained mode shape changes are used in the solution procedure, resulting in a reduction of the unnecessary calculations. Among the set of equations which characterizes the redesign of the structural systems, the under constrained problem is discussed here and formulated as an optimization problem, with an optimal criterion such as minimum change or minimum structural weight of the system. Four simple numerical applications illustrate the efficiency of the method. The method can be applied to the vibration problems of ships and/or offshore structures with an implementation of the commercial FE codes.

  • PDF

Spectrophotometric Determination of Some Fluoroquinolone Antibacterials through Charge-transfer and Ion-pair Complexation Reactions

  • El-Brashy, Amina Mohamed;Metwally, Mohamed El-Sayed;El-Sepai, Fawzi Abdallah
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.3
    • /
    • pp.365-372
    • /
    • 2004
  • Two simple, rapid and sensitive spectrophotometric methods for the determination of three fluoroquinolones, namely levofloxacin, norfloxacin and ciprofloxacin have been performed either in pure form or in their tablets. In the first method, levofloxacin and norfloxacin are directly treated with bromocresol green (BCG) in dichloromethane while ciprofloxacin is allowed to react with the same dye in aqueous acidic buffer. Highly yellow colored complex species were formed instantaneously in case of levofloxacin and norfloxacin or after extraction into dichloromethane for ciprofloxacin. The formed complexes are quantified spectrophotometrically at their absorption maxima at 411 nm for levofloxacin and 412 nm for norfloxacin and ciprofloxacin. The second method involves the reaction of levofloxacin with ${\rho}$-chloranilic acid ( ${\rho}$-CA) and norfloxacin with tetracyanoethylene (TCNE) in acetonitrile to give complexes with maximum absorbance at 521 and 333 nm for the two drugs, respectively. Adopting the first procedure, calibration graphs were linear over the range 1- 20 ${\mu}g\;mL^{-1}$ with mean percentage recoveries of 100.41 ${\pm}$ 0.72, 99.99 ${\pm}$ 0.54 and 100.23 ${\pm}$ 0.91 for the theree drugs, respectively. For the second procedure, the concentration ranges were 15-250 ${\mu}g\;mL^{-1}$ for levofloxacin using ${\rho}$-CA and 0.8-16 ${\mu}g\;mL^{-1}$ for norfloxacin using TCNE with mean percentage recoveries of 99.88 ${\pm}$ 0.45 and 100.26 ${\pm}$ 0.68 for the two drugs, respectively. The proposed methods were successfully applied to determine these drugs in their tablet formulations and the results compared favorably to that of reference methods. The proposed methods are recommended for quality control and routine analysis.

Design of a Waveguide Broad-wall Longitudinal Slot Array Antenna of X-type Monopulse Axes (X-형 모노펄스 축구조를 가지는 도파관 광벽 종방향 슬롯 배열 안테나의 설계)

  • 나형기;박창현
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.2
    • /
    • pp.208-216
    • /
    • 2002
  • In this paper, the design method of a waveguide broad-wall longitudinal slot array monopulse antenna of X-type monopulse axes is presented, and the method is verified through manufacture and measurement. In the antenna design of this paper, the antenna size is small and the monopulse axes are X-type. Thus, the common continuous aperture distribution fuction is not suitable and the power balance among antenna quadrants should be considered. Also, since the waveguide height is reduced into 0.1 wavelength, the modelling of the slot characteristics is not simple. Thus, in this paper, the aperture distribution is optimized by using random number, and the balance among the quadrants is achieved by applying the quadrant weighting factor during the aperture optimization process. Also, the moment method procedure is accelerated by applying the interpolation technique to some part of the moment matrix, and the moment method procedure is added to the array synthesis program as a subroutine so that the slot characteristics can be calculated directly when it is required. Based on this method, a antenna of 28dBi is designed and manufactured. It is found that the antenna characteristics is similar to design data.

Dual Plane Augmentation Genioplasty Using Gore-Tex Chin Implants

  • Kim, Byung Jun;Lim, Jong Woo;Park, Ji Hoon;Lee, Yoon Ho
    • Archives of Craniofacial Surgery
    • /
    • v.15 no.2
    • /
    • pp.82-88
    • /
    • 2014
  • Background: The chin shape and position is important in determining the general shape of the face, and augmentation genioplasty is performed alone or in combination with other aesthetic procedures. However, augmentation genioplasty using osteotomy is an invasive and complex procedure with the potential to damage mentalis muscle and mental nerve, to affect chin growth, and prolonged recovery. Our aim was to present our experience with a modified augmentation genioplasty procedure for hypoplastic chins using a Gore-Tex implant. Methods: Two vertical slit incisions were made at the canine level to create a supra-periosteal pocket between the incisions, preserving the periosteum and mentalis muscle. Minimal sub-periosteal dissection was performed lateral to the incisions along the mandibular border. The both wings of implant were inserted under the periosteum to achieve a stable dual plane implantation. Results: In total, 47 patients underwent dual plane chin augmentation using a Gore- Tex implant between January 2008 and May 2013. The mean age at operation was 25.77 years (range, 15-55 years). There were 3 cases of infection; one patient was treated with antibiotics, the others underwent implant removal. Additionally, two patients complained of postoperative parasthesia that spontaneously improved without any additional treatment. Most patients were satisfied with the postoperative outcomes, and no chin growth problems were observed among the younger patients. Conclusion: Dual plane Gore-Tex chin augmentation is a minimally-invasive operation that is simple and safe. All implants yielded satisfactory results with no significant complications such as mental nerve injury, lower lip incompetence, or chin growth limitation.