• Title/Summary/Keyword: simple method

Search Result 13,685, Processing Time 0.046 seconds

A Simple Method for Conversion of the Lunar into Solar Calendar (음력(陰曆)을 양력(陽曆)으로 환산(換算)하는 간편(簡便)한 방법(方法) - 고려(高麗) 이조(李朝) 천문(天文) 연구(硏究) 1 -)

  • Park, Dong-Hyun
    • Journal of The Korean Astronomical Society
    • /
    • v.1 no.1
    • /
    • pp.19-27
    • /
    • 1968
  • A simple method for solar-lunar calendar conversion is obtained by means of Meton period for the convinience of the date conversion in the study of the old records of astronomical observations in Korea.

  • PDF

A Numerical Ductile Failure Simulation Technique Based on Phenomenological Damage Concept (수치해석을 이용한 현상학적 연성파괴 모사 기법)

  • Kim, Nak-Kyun;Oh, Chang-sik;Min, Sung-hwan;Kim, Yun-Jae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.5 no.2
    • /
    • pp.27-34
    • /
    • 2009
  • This paper proposes a simple numerical method to simulate ductile failure behaviors. The method is based on finite element analysis with a simple damage theory. To validate the proposed method, simulated results are compared with experimental data. Despite its simplicity, the proposed method well predicts experimental results systematic analyses are also performed to investigate the effect of the element size.

  • PDF

Unbiased Balanced Half-Sample Variance Estimation in Stratified Two-stage Sampling

  • Kim, Kyu-Seong
    • Journal of the Korean Statistical Society
    • /
    • v.27 no.4
    • /
    • pp.459-469
    • /
    • 1998
  • Balanced half sample method is a simple variance estimation method for complex sampling designs. Since it is simple and flexible, it has been widely used in large scale sample surveys. However, the usual BHS method overestimate the true variance in without replacement sampling and two-stage cluster sampling. Focusing on this point , we proposed an unbiased BHS variance estimator in a stratified two-stage cluster sampling and then described an implementation method of the proposed estimator. Finally, partially BHS design is explained as a tool of reducing the number of replications of the proposed estimator.

  • PDF

A Note on Estimating Parameters in The Two-Parameter Weibull Distribution

  • Rahman, Mezbahur;Pearson, Larry M.
    • Journal of the Korean Data and Information Science Society
    • /
    • v.14 no.4
    • /
    • pp.1091-1102
    • /
    • 2003
  • The Weibull variate is commonly used as a lifetime distribution in reliability applications. Estimation of parameters is revisited in the two-parameter Weibull distribution. The method of product spacings, the method of quantile estimates and the method of least squares are applied to this distribution. A comparative study between a simple minded estimate, the maximum likelihood estimate, the product spacings estimate, the quantile estimate, the least squares estimate, and the adjusted least squares estimate is presented.

  • PDF

Analysis on a Simple Waveguide Using Meshfree Method (무요소법을 이용한 waveguide 내의 필드 분포 해석)

  • Lee, Chany;Woo, Dong-Kyun;Jung, Hyun-Kyo
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.190-192
    • /
    • 2008
  • This paper shows the formulation of fast moving least square reproducing kernel method (FMLSRKM) which is a kind of meshfree methods. FMLSRKM has some advantages compared to conventional numerical techniques such as finite element method. For simple analysis on a rectangular waveguide, point collocation scheme is introduced and applied.

  • PDF

A Simple Method for the Monitoring of Photo-induced Alignment of the Azobenzene Molecules in a Poly(malonic ester)

  • Shin, H.D.;Hwang, U.J.;Oh, C.H.;Song, S.H.;Kim, P.S.;Han, Y.K.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.6 no.1
    • /
    • pp.1-4
    • /
    • 2002
  • A simple method for real-time monitoring the molecular orientation in a polymeric film was suggested. This method was examined in the polarization holograms by two recording beams on a poly(malonic ester) containing disperse red 1. The spatial distributions of the photo-induced alignment were measured and analyzed at various polarization states of two recording beams. As the result, the directions of molecular alignments could be identified easily by our method.

  • PDF

Analysis of loop duct system by extended T-method (확장 T-method에 의한 환상식 덕트시스템 해석)

  • 이승철;문종선;이재헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.389-397
    • /
    • 1998
  • A loop duct system is often found in a VAV-HVAC(variable air volume heating, ventilating and air conditioning) design. It is known that the simple T-method is not be applicable to the loop duct system and cannot be used to calculate the flow rate and the pressure drop at each duct section of the loop duct system. In this paper, the extended T-method has been developed and it is found to be applicable to the loop duct system to which the simple T-method cannot be applied. The validity of the extended T-method has been verified by using to solve for a simple, ideal loop duct system for which there exists analytical solution. In addition, the extended T-method is employed to compute the loop duct system of a real building with an area of 380$m^2$. The results show that the computed flow rate at the exit differs from the designed flow rate by a range of -13.6~43.5 %. Consequently, three design factors must be adjusted in order that the flow rate may be balanced. These include the duct sizes, in terms of their lengths and diameters, the sub-duct locations and the positioning of damper which is found upstream of the exit duct.

  • PDF

Formulation and Verification on Ritz Method for In-Cabinet Response Spectrum (캐비닛내부응답스펙트럼 산정을 위한 리츠방법의 정식화 및 단순예제를 통한 검증)

  • Kim, Ki Hyun;Hong, Kee-Jeung;Cho, Sung Gook;Park, Woong Ki
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.23 no.5
    • /
    • pp.279-288
    • /
    • 2019
  • Safety-related cabinets and their electrical parts, such as relays and switches in nuclear power plants, should maintain continuous functioning, as well as structural safety according to the nuclear regulatory guidelines. Generally, an electrical part is qualified if its functioning is maintained without abnormality during excitement by motion compatible with the test response spectrum, which is larger than its in-cabinet response spectrum (ICRS). ICRS can be determined by shake-table test or dynamic analysis. Since existing cabinets in use can hardly be stopped and moved, dynamic analysis is preferred over shake-table test in determining ICRS. The simple method, suggested by the Electric Power Research Institute (EPRI) to determine ICRS, yields conservative or non-conservative results from time to time. In order to determine that the ICRS is better than EPRI method in a simple way, Ritz method considering global and local plate behaviors was suggested by Gupta et al. In this paper, the Ritz method is modified in order to consider the rocking and frame behaviors simultaneously, and it is applied to a simple numerical example for verification. ICRS is determined by Ritz method and compared with the results by finite element method (FEM). Based on this numerical example, recommendations for using Ritz method are suggested.

A New input-filtering method for High Speed Counter module of PLC using embedded timer pulse function of general purpose MPU (범용 MPU 내장 타이머 펄스 출력을 이용한 PLC 고속 카운터 모듈의 입력 필터링 기능 개선)

  • Park, Kang-Hee;Lee, Sang-Beak;Han, Kyoung-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1798-1799
    • /
    • 2011
  • In this paper, A new cost-effective and accurate input noise rejection method for High Speed Counter module of PLC (Programmable Logic Controller) is proposed. By using combination of simple additional logic circuit and the Timer Pulse function of general purpose MPU, Cost-effectiveness and improvement of accuracy of filtering function can be achieved. This proposed method is verified by simulation. This proposed method is much useful for simple industrial controller based on simple microprocessor because of simplicity, accuracy and low cost.

  • PDF

A Simple Current Ripple Reduction Method for B4 Inverters

  • Lee, Dong-Myung;Park, Jae-Bum;Toliyat, Hamid A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.5
    • /
    • pp.1062-1069
    • /
    • 2013
  • This paper proposes a simple current compensation method to improve the control performance of B4 inverters. Four-switch inverters so called B4 inverters employ only four switches. They have a split dc-link and one phase of three-phase motors is connected to the center-tap of split dc-link capacitors in B4 inverters. The voltage ripples in the center tap of the dc-link generate unbalanced three-phase voltages causing current ripples. To solve this problem, this paper presents a simple compensation method that adjusts switching times considering dc-link voltage ripples. The validity of the proposed method is verified by simulations and experiments carried out with a 1 HP induction machine.