• 제목/요약/키워드: simple frame

검색결과 589건 처리시간 0.026초

프레임간 상관관계를 고려한 장면기반 MPEG 비디오 트래픽 모델링 (Scen based MPEG video traffic modeling considering the correlations between frames)

  • 유상조;김성대;최재각
    • 한국통신학회논문지
    • /
    • 제23권9A호
    • /
    • pp.2289-2304
    • /
    • 1998
  • For the performance analysis and traffic control of ATM networks carrying video sequences, need an appropriate video traffic model. In this paper, we propose a new traffic model for MPEG compressed videos which are widely used for any type of video applications at th emoment. The proposed modeling scheme uses scene-based traffic characteristics and considers the correlation between frames of consecutiv GOPs. Using a simple scene detection algorithm, scene changes are modeled by state transitions and the number of GOPs of a scene state is modeled by a geometric distirbution. Frames of a scene stte are modeled by mean I, P, and B frame size. For more accurate traffic modeling, quantization errors (residual bits) that the state transition model using mean values has are compensated by autoregressive processes. We show that our model very well captures the traffic chracteristics of the original videos by performance analysis in terms of autocorrelation, histogram of frame bits genrated by the model, and cell loss rate in the ATM multiplexer with limited buffers. Our model is able to perrorm translations between levels (i.e., GOP, frame, and cell levels) and to estimate very accurately the stochastic characteristics of the original videos by each level.

  • PDF

Investigation of rotational characteristics of column 'PINNED' bases of steel portal frames

  • Liu, Timothy Chi-Ho
    • Steel and Composite Structures
    • /
    • 제1권2호
    • /
    • pp.187-200
    • /
    • 2001
  • Most of the portal frames are designed these days by the application of plastic analysis, with the normal assumption being made that the column bases are pinned. However, the couple produced by the compression action of the inner column flange and the tension in the holding down bolts will inevitably generate some moment resistance and rotational stiffness. Full-scale portal frame tests conducted during a previous research program had suggested that this moment can be as much as 20% of the moment of resistance of the column. The size of this moment of resistance is particularly important for the design of the tensile capacity of the holding down bolts and also the bearing resistance of the foundation. The present research program is aiming at defining this moment of resistance in simple design terms so that it could be included in the design of the frame. The investigation also included the study of the semi-rigid behaviour of the column base/foundation, which, to a certain extent, affects the overall loading capacity and stiffness of the portal frames. A series of column bases with various details were tested and were used to calibrate a finite element model which is able to simulate the action of the holding down bolts, the effect of the concrete foundation and the deformation of the base plate.

FD-CD 트랜스코팅기법에서 CD에 의한 전파/누적 왜곡의 분석과 모델링 (An Analysis and Modeling of Propagation/Accumulation Errors Incurred by CD in the FD-CD Transcoding)

  • 김진수;김재곤;김형명;홍진우
    • 한국통신학회논문지
    • /
    • 제29권12C호
    • /
    • pp.1677-1685
    • /
    • 2004
  • 최근에 FD(frame Dropping)-CD(Coefficient Dropping) 트랜스코딩기법은 계산량을 줄이고, 손쉽게 구현할 수 있다는 측면에서 주목을 받고 있다. 그러나, 기존의 기법에서는 CD로 인하여 발생되는 왜곡 특성이 GOP내의 부호화 의존성을 갖는 프레임의 복호화 영상 품질에 전파 및 누적되는 성질을 고려하고 있지 않다. 본 논문에서는 CD로 인하여 발생되는 왜곡을 수식적으로 분석하고, CD왜곡이 전파/누적됨을 모의실험을 통하여 분석한다. 또한, 실험직인 결과에 기초하여, CD에 의한 전파/누적 왜곡 특성을 지수 감소함수 형태로 모델링한다. 모의실험을 통하여, 제안된 모델은 CD로 인해 초래되는 전체 누적왜곡 크기를 잘 예측할 수 있음을 보인다.

Nonlinear structural finite element model updating with a focus on model uncertainty

  • Mehrdad, Ebrahimi;Reza Karami, Mohammadi;Elnaz, Nobahar;Ehsan Noroozinejad, Farsangi
    • Earthquakes and Structures
    • /
    • 제23권6호
    • /
    • pp.549-580
    • /
    • 2022
  • This paper assesses the influences of modeling assumptions and uncertainties on the performance of the non-linear finite element (FE) model updating procedure and model clustering method. The results of a shaking table test on a four-story steel moment-resisting frame are employed for both calibrations and clustering of the FE models. In the first part, simple to detailed non-linear FE models of the test frame is calibrated to minimize the difference between the various data features of the models and the structure. To investigate the effect of the specified data feature, four of which include the acceleration, displacement, hysteretic energy, and instantaneous features of responses, have been considered. In the last part of the work, a model-based clustering approach to group models of a four-story frame with similar behavior is introduced to detect abnormal ones. The approach is a composition of property derivation, outlier removal based on k-Nearest neighbors, and a K-means clustering approach using specified data features. The clustering results showed correlations among similar models. Moreover, it also helped to detect the best strategy for modeling different structural components.

Numerical models for stress analysis of non-uniform corroded tubular members under compression

  • Chinh, Vu Dan;Nguyen, Ha Thi Thu
    • Structural Engineering and Mechanics
    • /
    • 제84권4호
    • /
    • pp.517-530
    • /
    • 2022
  • In re-assessing the Jacket-type fixed steel structures, the current standards often allow the simplicity of corrosion sections using local buckling or equivalent section approach to applying empirical formulae of frame stress and resistance analyses. However, those approaches can lead to significant errors for non-uniform corroded frames in a specific area, including force distribution, stress, and allowable strength of the tubular section, compared to the actual cases. This paper investigates a suitable approach to determine the actual stress on non-uniform corroded tubular frames under compression through the non-linear ABAQUS model by considering the effect of large deformation on the frame axis and the frame section. There are 3 scenarios of interest. In the 1st and 2nd scenarios with simple corrosion cases, the stress ratios using the numerical model and theoretical formulae correspond to the calculation of allowable strength reduction ratios in standards. However, scenario 3, which describes non-uniform corroded sections based on survey data, provides considerable differences in results. Therefore, it proves the reliable and effective results when using this method to analyze the resistance of the actual corroded section in the Jacket platforms.

Shaking table study of a 2/5 scale steel frame with new viscoelastic dampers

  • Chang, K.C.;Tsai, M.H.;Lai, M.L.
    • Structural Engineering and Mechanics
    • /
    • 제11권3호
    • /
    • pp.273-286
    • /
    • 2001
  • Viscoelastic (VE) dampers have shown to be capable of providing structures with considerable additional damping to reduce the dynamic response of structures. However, the VE material appears to be sensitive to the variations in ambient temperature and vibration frequency. To minimize these effects, a new VE material has been developed. This new material shows less sensitivity to variations in vibration frequency and temperature. However, it is highly dependent on the shear strain. Experimental studies on the seismic behavior of a 2/5 scale five-story steel frame with these new VE dampers have been carried out. Test results show that the structural response can be effectively reduced due to the added stiffness and damping provided by the new type of VE dampers under both mild and strong earthquake ground motions. In addition, analytical studies have been carried out to describe the strain-dependent behavior of the VE damper. The dynamic properties and hysteresis behavior of the dampers can be simulated by a simple bilinear model based on the equivalent dissipated energy principle proposed in this study.

다른 선폭들로 구성된 격자형 교정판을 이용한 간단한 카메라 교정 시스템의 개발 (A development of the simple camera calibration system using the grid type frame with different line widths)

  • 정준익;최성구;노도환
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.371-374
    • /
    • 1997
  • Recently, the development of computer achieves a system which is similar to the mechanics of human visual system. The 3-dimensional measurement using monocular vision system must be achieved a camera calibration. So far, the camera calibration technique required reference target in a scene. But, these methods are inefficient because they have many calculation procedures and difficulties in analysis. Therefore, this paper proposes a native method that without reference target in a scene. We use the grid type frame with different line widths. This method uses vanishing point concept that possess a rotation parameter of the camera and perspective ration that perspect each line widths into a image. We confirmed accuracy of calibration parameter estimation through experiment on the algorithm with a grid paper with different line widths.

  • PDF

건축구조물의 비선형 지진응답 산정을 위한 내진성능평가 방법의 비교 (Comparison of Performance Evaluation Methods Based on the Estimation of Nonlinear Seismic Responses for Multistory Building)

  • 최원호;이동근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.349-356
    • /
    • 2002
  • There has been an increasing trend toward the use of pushover analysis as a tool for evaluating the seismic resistant and safety of a building structure in the performance based earthquake engineering field. The ATC-40 document proposed a nonlinear static procedure based on the Capacity Spectrum Method to determine earthquake-induced demand given the structure pushover curve, which a curve representing base shear versus roof displacement. However, the procedure is conceptually simple, iterative and time consuming method and may sometimes lead to no solution or multiple solutions. A new improved method of seismic performance evaluation for moment frame building, which take into account the previously mentioned deficiencies of currently used elastic design procedures, is presented in this paper. The results of nonlinear static and nonlinear time history analysis of an example high-rise steel moment frame designed by the proposed method are presented and discussed.

  • PDF

한국어 연속음성중 키워드 인식을 위한 반연속 은닉 마코브 모델과 One-Pass 알고리즘의 개선방안 (Improvement of Semicontinuous Hiden Markov Models and One-Pass Algorithm for Recognition of Keywords in Korean Continuous Speech)

  • 최관선
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 제11회 음성통신 및 신호처리 워크샵 논문집 (SCAS 11권 1호)
    • /
    • pp.358-363
    • /
    • 1994
  • This paper presents the improvement of the SCHMM using discrete VQ and One-Pass algorithm for keywords recognition in Korean continuous speech. The SCHMM using discrete VQ is a simple model that is composed of a variable mixture gaussian probability density function with dynamic mixture number. One-Pass algorithm is improved such that recognition rates are enhanced by fathoming any undesirable semisyllable with the low likelihood and the high duration penalty, and computation time is reduced by testing only the frame which is dissimilar to the previously testd frame. In recognition experiments for speaker-dependent case, the improved One-Pass algorithm has shown recognition rates as high as 99.7% and has reduced compution time by about 30% compared with the currently abailable one-pass algorithm.

  • PDF

Serviceability design of a cold-formed steel portal frame having semi-rigid joints

  • Lim, J.B.P.;Nethercot, D.A.
    • Steel and Composite Structures
    • /
    • 제3권6호
    • /
    • pp.451-474
    • /
    • 2003
  • Details are given of a cold-formed steel portal framing system that uses simple bolted moment-connections for both the eaves and apex joints. However, such joints function as semi-rigid and, as a result, the design of the proposed system will be dominated by serviceability requirements. While serviceability is a mandatory design requirement, actual deflection limits for portal frames are not prescribed in many of the national standards. In this paper, a review of the design constraints that have an effect on deflection limits is discussed, and rational values appropriate for use with cold-formed steel portal frames are recommended. Adopting these deflection limits, it is shown through a design example how a cold-formed steel portal frame having semi-rigid eaves and apex joints can be a feasible alternative to rigid-jointed frames in appropriate circumstances.