• Title/Summary/Keyword: silA

Search Result 3,595, Processing Time 0.031 seconds

Design of Automatic Model Verification for System Integration Laboratory (통합시험환경 모델 검증 자동화 설계)

  • Yang, Seung-Gu;Cho, Yeon-Je;Jo, Kyoung-Yong;Ryu, Chang-Myung
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.361-366
    • /
    • 2019
  • In developing the avionics system, a system integration laboratory (SIL) is established to verify the function and interworking of individual components. In case of individual verification of SIL's components and system integration, a SIL model that simulates the function and interworking of each equipment is developed and used. A SIL model shall be pre-verified against all data defined in the interface control document (ICD) before interworking with the actual equipment and reverified even when the ICD changes or functions change. However, if the verification of the SIL model is performed manually, the verification of the individual SIL model takes considerable time. For this reason, selective regression tests are often performed to determine a impact of SIL models on ICD changes and some functional changes. In this paper, we designed SIL model verification automation method to perform regession test by reducing verification time of SIL model and verify the usefulness of verification automation design by developing SIL model verification automation tool.

A Study on the Sil-Sil and Chun (슬슬.전고)

  • 김영재
    • Journal of the Korean Society of Costume
    • /
    • v.31
    • /
    • pp.215-222
    • /
    • 1997
  • This is a study on Sil-Sil and Chun. Sil-Sil is a kind of turquoise. According to its burial place and use its identity was fixed, It was discovered in the Middle-East Asia like Iran and Tibet, Ancient China imported turquoise from these countries,. Korea also imported it in Shilla period. It was the empresses only who had the priviledge of using Sil-Sil for their ornaments such as hair-pins headdresses and combs. Chun was a sort of metal ornaments. Chun required a high-skilled work' and it showed how advanced its skill at that time.

  • PDF

Towards the Application of Safety Integrity Level for Improving Process Safety (공정안전향상을 위한 Safety Integrity Level의 적용 방향)

  • Kwon, Hyuck-Myun;Park, Hee-Chul;Chun, Young-Woo;Park, Jin-Hyung
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.64-69
    • /
    • 2012
  • The concept of SIL is applied in the most of all standards relating to functional system safety. However there are problems for the people to apply SIL to their plants. as these standards don't include sufficient informations. In this regards, this paper will suggest the direction of SIL application and concept based on IEC 61508 and IEC 61511. A Safety Integrity Level(SIL) is the discrete level(one out of possible fours), corresponding to a range of the probability of an E/E/PE (Electric/Electrical/Programmable Electrical) safety-related system satisfactorily performing the specific safety functions under all the stated conditions within a stated period of time. SIL can be divided into the target SIL(or required SIL) and the result SIL. The target SIL is determined by the risk analysis at the analysis phase of safety lifecycle and the result SIL is calculated during SIL verification at the realization phase of safety lifecycle. The target SIL is determined by the risk analysis like LOPA(Layer Of Protection Analysis), Risk Graph, Risk Matrix and the result SIL is calculated by HFT(Hardware Fault Tolerance), SFF(Safe Failure Fraction) and PFDavg(average Probability of dangerous Failure on Demand). SIL is applied to various areas such as process safety, machinery(road vehicles, railway application, rotating equipment, etc), nuclear sector which functional safety is applied. The functional safety is the part of the overall safety relating to the EUC and the EUC control system that depends on the correct functioning of the E/E/PE safety-related systems and other risk reduction measures. SIL is applied only to the functional safety of SIS(Safety Instrumented System) in safety. EUC is the abbreviation of Equipment Under Control and is the equipment, machinery, apparatus or plant used for manufacturing, process, transportation, medical or other activities.

A Case Study of SIL Analysis for Single Station Controller in Nuclear Power Plant Based on IEC 61508 (IEC 61508에 기반한 원자력 발전소용 안전 등급 제어기의 SIL 분석에 대한 사례연구)

  • Kim, Gun Myung
    • Journal of Applied Reliability
    • /
    • v.16 no.3
    • /
    • pp.231-237
    • /
    • 2016
  • Purpose: It is not easy to suggest a quantitative data related to safety analysis. The objective of this paper is to propose a method of Safety Integrity Level (SIL) analysis and to suggest a SIL analysis result for single station controller in nuclear power plant based on IEC 61508. Methods: The Failure Modes and Effects Diagnostic Analysis (FMEDA) and average probability of failure on demand (PFD) are used for SIL assessment. Results: A SIL of single station controller is evaluated 4 by a reliability analysis results and PFD. Conclusion: A SIL analysis method and result for single station controller based on IEC 61508 are proposed in this paper. It can applicable for a manufacturer data in safety-related system.

Isolation and Functional Analysis of the silA Gene That Controls Sexual Development in Response to Light in Aspergillus nidulans (Aspergillus nidulans의 광 조건하 유성분화에 관여하는 silA 유전자의 분리 및 기능분석)

  • Han, Sang-Yong;Ko, Jin-A;Kim, Jong-Hak;Han, Kyu-Yong;Han, Kap-Hoon;Han, Dong-Min
    • The Korean Journal of Mycology
    • /
    • v.36 no.2
    • /
    • pp.189-195
    • /
    • 2008
  • When a homothallic ascomycete Aspergillus nidulans is exposed to visible light, cleistothecial development is inhibited. The light response of development in A. nidulans implies the existence of delicate regulation process including reception and translocation of light signaling and determination of development. Previously, mutants that could develop cleistothecia even in the presence of relatively intensive visible light were isolated and several complementation groups were identified. A gene that was able to complement the silA98 mutation, which was responsible for preferred cleistothecia development under visible light, was isolated from AMA-NotI genomic library. The silA gene retained in the 4.3 kb recovered genomic library DNA has an open reading frame (ORF) consisted of 2,388 bp nucleotides, interrupted by 3 introns and consequently encoding 795 amino acids. The putative SilA carries a ${Zn_2}{Cys_6}$ binuclear cluster motif at N terminus and shows high amino acid sequence similarity to Aro80p of Saccharomyces cerevisiae. Deletion mutants of silA showed a strong induction of sexual development under visible light, indicating that SilA is involved in the negative regulation of sexual development in response to the light.

Advanced SIL(A-SIL) system for Near Field Recording (A-SIL 을 이용한 근접장 저장)

  • Han, I.G.;Shin, Y.S.;Park, J.M.;Lee, J.U.;Seo, J.K.;Choi, I.H.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.1028-1030
    • /
    • 2007
  • Mutual compensating concept between SIL(Solid Immersion Lens) and OL(Objective Lens) of NFR(Near Field Recording) is proposed, designed and manufactured to achieve a high NA and obtain a wider manufacturing tolerance. Tolerance information is present in article. An effective NA of Advanced SIL is 1.7 and adjustment between OL and SIL is carried out using our interferometer. We measured very clear RF signal using 3-axis actuator at Test bed.

  • PDF

A Study on FMEDA Process for SIL Certification : A Case Study of a Flame Scanner (SIL 인증을 위한 FMEDA 프로세스 연구 : 화염검출기 사례를 중심으로)

  • Kim, Sung Kyu;Kim, Yong Soo
    • IE interfaces
    • /
    • v.25 no.4
    • /
    • pp.422-430
    • /
    • 2012
  • In this article, we introduced the estimation method by 'Safety Integrity Level'(SIL) for the criterion of safety assurance and performed a case study on a flame scanner. SIL requires probabilistic evaluation of each set of equipment used to reduce risk in a safety related system. FMEDA(Failure Modes, Effects and Diagnostic Analysis) method is widely used to evaluate the safety levels and provides information on the failure rates and failure mode distributions necessary to calculate a diagnostic coverage factor for a part or a component. Basically, two parameters resulting from FMEDA are used for SIL classification of the device : SFF(Safe Failure Fraction) and PFD(Probability of Failure on Demand). In this case study, it is concluded that the flame scanner is designed to fulfill the condition of SIL 3 in the aspect of SFF and PFD.

Optimum SIL System Design with High NA and Large Tolerance

  • Won, Ki-Tak;Choi, Na-Rak;Kim, Jai-Soon;Lee, Ji-Yeon;Lee, Kyung-Eon;Shin, Yun-Sup
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2007.02a
    • /
    • pp.277-278
    • /
    • 2007
  • Even though high NA, Hyper SIL system easily decline the optical performance even a little alignment error. Not only to overcome this instability but to maintain the high NA gain, we suggest a new system (Optimum SIL) which is a combination of each advantage of Hyper SIL and Hemi SIL. Simulation results shows that Optimum SIL system has much higher tolerance to various performance-lowering factors than Hyper SIL system even with a relatively small NA resignation.

  • PDF

A Study on Assembly and Evaluation of SIL optical Head for surface Recording of SIL based NFR (고체침지렌즈 기반 근접장 표면 기록을 위한 고체침지렌즈 광학 헤드의 조립 및 평가에 대한 연구)

  • Min, Cheol-Ki;Kim, Tae-Seob;Yoon, Yong-Joong;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.4 no.1
    • /
    • pp.19-22
    • /
    • 2008
  • For the assembly and evaluation of solid immersion lens (SIL) optical head which is the key component of SIL based near field recording (NFR) technology, we modify the Twyman-Green interferometer. Super-hemisphere SIL optical head for the surface recording is assembled and evaluated by the modified Twyman-Green interferometer. In order to verify the optical performance of the assembled SIL optical head, we compare the measured results of the SIL optical head with the simulation ones. Finally, we show the feasibility of applying the assembled SIL optical head to near field recording system by the experiment of the dynamic gap control based on test bed.

  • PDF

Design of STE SW Running on a Single PC to Verify Avionics OFP (항전 비행운용프로그램 검증을 위한 단일 PC 기반 소프트웨어 시험환경 SW 설계)

  • Cha, Sang-Cheol;Lee, Du-Hwan;Kim, Jeong-Yeol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.11
    • /
    • pp.969-973
    • /
    • 2018
  • Avionics OFP runs on the mission computer and can be operated by interacting with several avionics equipments. In order to verify OFP SW, SIL having real avionics equipments or models is absolutely necessary. Therefore in many cases SIL is implemented concurrently with OFP developing, and only one SIL is provided to developers. So developers sometimes need an alternative to SIL for verifying requirements in the middle of development process. In this paper, we propose a single PC based STE SW that simulates interworking equipments and verifies OFP in a single PC environment without actual interworking equipments or SIL HW interfaces.