• Title/Summary/Keyword: signal-to-signal conversion

Search Result 643, Processing Time 0.029 seconds

A Study on the Optimal Signal Timing for Area Traffic Control (지역 교통망 관리를 위한 최적 신호순서에 관한 연구)

    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.24 no.2
    • /
    • pp.69-80
    • /
    • 1999
  • A genetic algorithm to determine the optimal signal sequence and double cycle pattern is described. The signal sequence and double cycle pattern are used as the input for TRANSYT to find optimal signal timing at each junction in the area traffic networks, In the genetic process, the partially matched crossover and simple crossover operators are used for evolution of signal sequence and double cycle pattern respectively. A special conversion algorithm is devised to convert the signal sequence into the link-stage assignment for TRANSYT. Results from tests using data from an area traffic network in Leicester region R are given.

  • PDF

Digital-Radio Conversion System using Vector Synthesis Method (벡터합성방법에 의한 디지털-무선 변환시스템)

  • Joo Chang Bok;Kim Sung Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.1 no.2
    • /
    • pp.131-137
    • /
    • 2000
  • In this paper, as a compatible software radio transmission system, Digital-Radio conversion system which can directly change the digital signal generated by the logic circuit into radio signal is proposed. By the vector synthesis method, the digital signals can change directly into radio signal. If such a circuit is realized, RF circuit and an antenna can be composed by the simple one device, and the radio is directly controlled and performed by the software processing which is the essence of software radio. This Digital-Radio conversion system of this paper give many number of communication channels being offered by PN code and offer a hardware design flexibility by digitization, therefore it decrease the percentage ratio of hardware of system and give a more flexible function of software basis. In this paper, the principle of digital to radio signal generation algorithm is explained and the performance characteristics of proposed algorithm is shown in time base by the computer simulation method.

  • PDF

Design of Microwave Direct Conversion Receiver Using Sub-Harmonics Pumped Ring Mixer (SHP 링혼합기를 이용한 마이크로파 직접변환 수신기 설계)

  • Kim, Kab-Ki;Kim, Han-Suk;Yoo, Hong-Gil;Lee, Jong-Arc
    • Journal of IKEEE
    • /
    • v.3 no.1 s.4
    • /
    • pp.69-78
    • /
    • 1999
  • In this paper, direct conversion receiver was designed to even harmonic anti-paralled diode pair ring mixer. Using a second harmonic component of LO instead of LO signal and RF signal are mixed by SHP(Sub Harmonic Pumped) mixer with anti-parallel diode pair. Canceling the harmonics of LO signal in ring mixer, SHP mixer using anti-parallel diode pair could mostly reduce the radiation of LO signal through a input port the most, good isolation characteristic, and low spurious characteristic by LO signal was shown over broad band. The produced SHP mixer showed LO/IF, RF/IF and LO/RF isolation was 24.6dB,36.2dB and 22.5dB respectively. And conversion loss was measured 15.6dB, IF output -35.6dBm with -20dBm RF input and 5.5dBm LO signal. 1dB compression point of If signal, in respect to RF signal, was found at the 0dbm RF signal.

  • PDF

Network analysis by signal-flow graph (Signal-flow graph에 의한 회로분석)

  • Hyung Kap Kim
    • 전기의세계
    • /
    • v.17 no.2
    • /
    • pp.11-15
    • /
    • 1968
  • One of the most important methods used in the modern analysis of linear networks and systems is the signal flow graph technique, first introduced by S.J. Mason in 1953. In essence, the signal-flow graph technique is a graphical method of solving a set of simultaneous. It can, therefore, be regarded as an alternative to the substitution method or the conventional matrix method. Since a flow-graph is the pictorial representation of a set of equations, it has an obvious advantage, i.e., it describes the flow of signals from one point of a system to another. Thus it provides cause-and-effect relationship between signals. And it often significantly reduces the work involved, and also yields an easy, systematic manipulation of variables of interest. Mason's formula is very powerful, but it is applicable only when the desired quantity is the transmission gain between the source node and sink node. In this paper, author summarizes the signal-flow graph technique, and stipulates three rules for conversion of an arbitrary nonsource node into a source node. Then heuses the conversion rules to obtain various quantities, i.e., networks gains, functions and parameters, through simple graphical manipulations.

  • PDF

Color Temperature Conversion of Uncalibrated Video Signal Based on Color Compensation in POP-TV

  • Do, Hyun-Chul;Chien, Sung-Il;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2003.07a
    • /
    • pp.718-721
    • /
    • 2003
  • It is often desirable that manufacturers and users can convert the reference white of display into the preferred color temperature by controlling the color temperature that is one of representative color characteristics of a light source. Accordingly, this paper proposes an efficient method of color compensation for displaying the uncalibrated video signal in PDP-TV and is also shown to be successfully coupled with flexible color temperature conversion based on the signal processing technique.

  • PDF

Super-High Speed Photo detection through Frequency Conversion for Microwave on Optical Network

  • Choi, Young-Kyu;Shin, Sang-Yeol
    • Journal of information and communication convergence engineering
    • /
    • v.6 no.4
    • /
    • pp.439-443
    • /
    • 2008
  • It is shown that even if the modulating frequency of the light is too high for direct detection the signal can be extracted by frequency conversion at the same time as the detection by means of the nonlinearity of the APD. When this frequency conversion detection is applied to an optical receiver, the detection bandwidth can be increased while the configuration of the optical detection circuit and the signal processing in the subsequent stages are simplified. A fundamental analysis is carried out with an APD which is confirmed experimentally.

An A/D Conversion of Signal Conditioning for Precision Instrumentation Use (정밀 계측 신호처리용 A/D 변환 구현)

  • Park, Chan-Won;Joo, Yong-Kyu
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.133-139
    • /
    • 2002
  • In precision instrumentation system, an A/D conversion of signal conditioning has been always suffered from some problems ; offset and drift voltage with environmental situation. This paper suggests a method of reducing the offset voltage and the drift error from the A/D conversion hardware using analog signal switching technique with specific operational amplifier circuits. Also, we have designed a hardware active filter and a software digital filter with Auto Zero Tracking algorithm for better dignal process of the our proposed weighing system. Software technique was performed to obtain the stable data from A/D converter. As a result of our experimental works, the proposed system is expected to be used in the industrial field where a high precision measurement is required.

  • PDF

An A/D Conversion System for Precision Weighing Signal Process (정밀 중량 계측 신호처리를 위한 A/D 변환 시스템)

  • Joo, Yong-Kyu;Jeon, Chan-Min;Park, Chan-Won
    • Proceedings of the KIEE Conference
    • /
    • 2002.11c
    • /
    • pp.301-304
    • /
    • 2002
  • This paper has been studied an A/D conversion system for precision weighing signal process In weighing system. A/D conversion has some problem.; offset drift voltage with environment situation and nonzero value of initial output voltage. The Offset voltage in analog circuit produces a drift of an output voltage before A/D conversion stage. This paper suggested the method of reducing the offset voltage by switching analog chopping circuit and making the initial output close to zero to enhance the swing range by D/A converter. Also, we have designed active filter and digital filter with Auto Zero Tracking algorithm for better signal process of the weighing system.

  • PDF

Estimation of I/Q Imbalance Parameters for Repeater using Direct Conversion RF with Low Pass Filter Mismatch (저역 통과 필터 불일치를 포함한 직접 변환 RF 중계기의 I/Q 불균형 파라미터 추정)

  • Yun, Seonhui;Lee, Kyuyong;Ahn, Jaemin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.18-26
    • /
    • 2015
  • In this paper, we studied the method for analyzing and estimating the parameters that induce I/Q imbalance in the repeater using direct conversion RF. In repeater, amplitude, phase, and filter mismatch are generated in the receiving-end which converts RF signal to baseband signal. And amplitude and phase mismatch are generated in the transmitting-end which converts baseband signal to RF signal. Accordingly, we modeled the parameters that cause I/Q imbalance in the structure of the repeater in order, and proposed a feedback test structure from the transmitting-end to the receiving-end for estimating the corresponding parameters. By comparing the test transmitting signal and received signal, it is possible to estimate the I/Q imbalance parameters which occurred from mixed components of real and imaginary part. And it was confirmed that I/Q imbalance phenomenon has been properly compensated with estimated parameters at the direct conversion RF repeater.

Development of 32-Channel Image Acquisition System for Thickness Measurement of Retina (망막 두께 측정을 위한 32채널 영상획득장치 개발)

  • 양근호;유병국
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.110-113
    • /
    • 2003
  • In this paper, the multi-channel high speed data acquisition system is implemented. This high speed signal processing system for 3-D image display is applicable to the manipulation of a medical image processing, multimedia data and various fields of digital image processing. In order to convert the analog signal into digital one, A/D conversion circuit is designed. PCI interface method is designed and implemented, which is capable of transmission a large amount of data to computer. In order to, especially, channel extendibility of images acquisition, bus communication method is selected. By using this bus method, we can interface each module effectively. In this paper, 32-channel A/D conversion and PCI interface system for 3-dimensional and real-time display of the retina image is developed. The 32-channel image acquisition system and high speed data transmission system developed in this paper is applicable to not only medical image processing as 3-D representation of retina image but also various fields of industrial image processing in which the multi-point realtime image acquisition system is needed.

  • PDF