• Title/Summary/Keyword: signal intensity

Search Result 1,219, Processing Time 0.034 seconds

A feasibility study evaluating the relationship between dose and focal liver reaction in stereotactic ablative radiotherapy for liver cancer based on intensity change of Gd-EOB-DTPA-enhanced magnetic resonance images

  • Jung, Sang Hoon;Yu, Jeong Il;Park, Hee Chul;Lim, Do Hoon;Han, Youngyih
    • Radiation Oncology Journal
    • /
    • v.34 no.1
    • /
    • pp.64-75
    • /
    • 2016
  • Purpose: In order to evaluate the relationship between the dose to the liver parenchyma and focal liver reaction (FLR) after stereotactic ablative body radiotherapy (SABR), we suggest a novel method using a three-dimensional dose distribution and change in signal intensity of gadoxetate disodium-gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced magnetic resonance imaging (MRI) hepatobiliary phase images. Materials and Methods: In our method, change of the signal intensity between the pretreatment and follow-up hepatobiliary phase images of Gd-EOB-DTPA-enhanced MRI was calculated and then threshold dose (TD) for developing FLR was obtained from correlation of dose with the change of the signal intensity. For validation of the method, TDs for six patients, who had been treated for liver cancer with SABR with 45-60 Gy in 3 fractions, were calculated using the method, and we evaluated concordance between volume enclosed by isodose of TD by the method and volume identified as FLR by a physician. Results: The dose to normal liver was correlated with change in signal intensity between pretreatment and follow-up MRI with a median $R^2$ of 0.935 (range, 0.748 to 0.985). The median TD by the method was 23.5 Gy (range, 18.3 to 39.4 Gy). The median value of concordance was 84.5% (range, 44.7% to 95.9%). Conclusion: Our method is capable of providing a quantitative evaluation of the relationship between dose and intensity changes on follow-up MRI, as well as determining individual TD for developing FLR. We expect our method to provide better information about the individual relationship between dose and FLR in radiotherapy for liver cancer.

Pallidal Signal Intensities on T1-weighted MRI are Highly Observed in Advanced Liver Cirrhosis

  • Weon, Young-Cheol;Park, Neung-Hwa;Kim, Yang-Ho;Lee, Heun
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.5
    • /
    • pp.380-385
    • /
    • 2012
  • Background: Manganese (Mn) has been found to increase the signal intensity of the globus pallidus (GP) on T1-weighted magnetic resonance images (MRI). We performed this study in order to determine the features of liver disease that correlate with pallidal signal intensities. Methods: We assessed blood Mn levels and pallidal signals in T1-weighted MRI in 49 patients with liver cirrhosis and 23 healthy controls. Results: Increased signal intensity in the GP was observed in 30 of 49 (61.2%) patients with liver cirrhosis, with the pallidal index (PI) in patients with Child-Pugh classes B and C differing significantly from the PI in controls. Multiple linear regression analysis showed that blood Mn concentrations and Child-Pugh scores in cirrhotics were significantly associated with increased PI after controlling for other confounders (p<0.05 each). Conclusions: Pallidal signals on T1-weighted MRI are mainly observed in advanced liver cirrhosis. The present study suggests that advanced liver cirrhosis may be a human model for manganism.

Carotid Intraplaque Hemorrhage Imaging: Diagnostic Value of High Signal Intensity Time-of-Flight MR Angiography Compared with Magnetization-Prepared Rapid Acquisition with Gradient-Echo Sequencing

  • Ahn, Ji-eun;Kwak, Hyo Sung;Chung, Gyung Ho;Hwang, Seung Bae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.94-101
    • /
    • 2018
  • Purpose: To determine the value of the appearance of the high signal intensity halo sign for detecting carotid intraplaque hemorrhage (IPH) on maximum intensity projection (MIP) of time-of-flight (TOF) MR angiography (MRA), based on high signal intensity on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) sequencing. Materials and Methods: A total of 78 carotid arteries in 65 patients with magnetization-prepared rapid acquisition gradient-echo (MPRAGE) positive on carotid plaque MR imaging were included in this study. High-resolution MR imaging was performed on a 3.0-T scanner prior to carotid endarterectomy or carotid artery stenting. Fast spin-echo T1- and T2-weighted axial imaging, TOF, and MPRAGE sequences were obtained. Carotid plaques with high signal intensity on MPRAGE > 200% that of adjacent muscle on at least two consecutive slices were defined as showing IPH. Halo sign of high signal intensity around the carotid artery was found on MIP from TOF MRA. Continuous and categorical variables were compared among groups using the Mann-Whitney test and Fisher's exact tests. Results: Of these 78 carotid arteries, 53 appeared as a halo sign on the TOF MRA. The total IPH volume of patients with a positive halo sign was significantly higher than that of patients without a halo sign ($75.0{\pm}86.8$ vs. $16.3{\pm}18.2$, P = 0.001). The maximum IPH axial wall area in patients with a positive halo sign was significantly higher than that of patients without a halo sign ($11.3{\pm}9.9$ vs. $3.7{\pm}3.6$, P = 0.000). Conclusion: High signal intensity halo of IPH on MIP of TOF MRA is associated with total volume and maximal axial wall area of IPH.

Radiologic Findings of Cervical Mass Type Cervical Pregnancy (자궁경부 종괴형 자궁경부임신의 영상 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.22 no.1
    • /
    • pp.43-51
    • /
    • 2005
  • Background: To examine the ultrasonographic and magnetic resonance (MRI) imaging findings of a cervical mass type cervical pregnancy. Materials and Methods: The ultrasonographic and MRI findings of 5 patients pathologically confirmed as having a cervical pregnancy were analyzed retrospectively. On ultrasonography, the size and echo pattern of the uterine cervix, the shape and echo pattern of the lesion, the degree and the pattern of blood flow on the color Doppler study and the spectral Doppler pattern were analyzed. The shape, signal intensity, and degree and pattern of enhancement of the lesion were evaluated on MRI. Results: The uterine cervix was enlarged and the size of the lesion was 6.1 to 7.1 (average, 6.5) cm. The endocervical canal was irregularly dilated and showed heterogeneous echogenicity in all 5 cases. Four of the 5 lesions were heterogeneously hyper- or mixed echoic and remaining one was relatively homogeneous echogenic. Doppler ultrasonography revealed an increased vascularity of the peritrophoblastic flow pattern. In all 4 cases where MRI performed, the lesion was irregular in shape and the margin was not sharply demarcated. The T2-weighed image showed that the lesions were mixed signal intensity. Three of the 4 lesions contained high signal intensity nodular portions and a low signal intensity rim was observed along the margin of the nodular portions. The T1-weighted image revealed multiple signal voids along the periphery of the lesions and high signal intensity portions as a result of hemorrhage were noted. The dynamic enhanced study showed that the high signal intensity portions on the T2-weighted image were strongly enhanced similar to the vessels on the early phase and the contrast enhancement gradually decreased with time. Conclusion: A cervical mass type cervical pregnancy can be correctly diagnosed using the patient's clinical symptom, the elevation in the serum ${\beta}$-HCG level, and characteristic ultrasonographic and MRI findings.

  • PDF

Limitations of time resolution and spatial overlap caused by group velocity mismatch in experiments using ultrashort UV and visible optical pulses. (자외선과 가시광선 극초단 펄스 실험의 군속도 차이에 의한 시간 분해능 및 공간 겹침의 제한)

  • 김성규
    • Korean Journal of Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.252-259
    • /
    • 1994
  • The method of calculating overlap dispersion caused by group velocity mismatch between uv and visible pulses in ultrafast pump-probe experiments is presented to discuss limitations of the time resolution and signal intensity. The calculations show arrangements using a single focusing lens shall result in undesirable time resolution and low signal intensity. Achromatic doublets result in unrealistic solutions. However, dramatic improvement in the time resolution and signal intensity is expected in the optical arrangements using separate lens for each pulse and in the arrangements using a cutoff secondary lens with a main lens. lens.

  • PDF

Radiologic Findings of Renal Oncocytomas (신장 호산성과립세포종의 영상의학적 소견)

  • Cho, Jae-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.26 no.1
    • /
    • pp.30-37
    • /
    • 2009
  • Purpose : To radiologically differentiate renal oncocytoma from other renal solid tumors, we analyzed and characterized, retrogradely, radiologic findings of renal oncocytomas. Materials and Methods : Radiologic findings of pathologically proven renal oncocytoma were analyzed in 9 patients. CT was performed in all patients, ultrasonography in 4 patients and MRI in 3 patients.(51) Results : On ultrasonography, the echogenicity of the mass was slightly more hyperechoic than normal renal parenchyma in all 4 cases. Two cases were homogeneous and the remaining two cases were relatively homogeneous. On CT, all 8 cases showed iso-density to slightly low density compared to normal renal parenchyma and 5 cases were homogeneous but the central portion of the mass was of a slightly lower density than the peripheral portion in 3 cases. All six cases had an arterial phase scan and were heterogeneously enhanced. An irregular, lower-enhancing portion was found in the central portion of the mass. Segmental inversion of contrast enhancement was found in 5 of 6 cases that had a dynamic enhancement study. On MR T1-weighted imaging, the mass was of iso-signal intensity to normal renal parenchyma and the central portion of the mass had a slightly hypo-signal intensity than the peripheral portion. On T2-weighted imaging, 2 cases were heterogeneous; the peripheral portion was of low signal intensity and central portion was of higher signal intensity than normal renal parenchyma. One case was relatively homogeneous and showed a slightly lower signal intensity than that of normal parenchyma, except for a central small portion showing high signal intensity. For 2 cases that had a dynamic study, a segmental inversion of contrast enhancement was noted. Conclusion : Renal oncocytoma is seen as a well-marginated solid mass lesion. On enhanced scans it is heterogeneously enhanced and segmental inversion of contrast enhancement may be seen. The possibility of oncocytoma can be suggested in cases showing these radiologic findings.

  • PDF

Optimal Signal Amplitude of Orthogonal Frequency-Division Multiplexing Systems in Dimmable Visible Light Communications

  • Yun, Kyungsu;Lee, Changho;Ahn, Kang-Il;Lee, Rimhwan;Jang, Ja-Soon;Kwon, Jae Kyun
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.459-465
    • /
    • 2014
  • Visible light communications (VLC) using the intensity modulation of light-emitting diodes (LEDs) provides a new communication medium to overcome the shortage of radio spectrum, and allows reuse of LED lighting infrastructures. Orthogonal frequency-division multiplexing (OFDM) was introduced to VLC for its merits in mitigating the fading effects resulting from delay spread, and in avoiding low-frequency ambient interference. Noise and clipping are two major factors that degrade the performance of OFDM in VLC. A larger signal easily overcomes noise, but experiences impairment by clipping. Therefore, degradation due to clipping has a trade-off relationship with that due to noise, depending on the signal amplitude of OFDM. In this paper, the optimal signal amplitude in the trade-off is obtained by simulation when the dimming and LED intensity are given. The former indicates a user's requirement for lighting, and the latter represents the channel quality. The required LED intensity-to-noise ratio, as the channel quality that guarantees dimming as well as an adequate bit-error rate (BER), is also discussed.

A Study on Indirect Attachment Method of Compensation Materials to Increase Signal Intensity in Magnetic Resonance Imaging (자기공명영상검사 시 신호강도를 높이기 위한 보상물질의 간접부착 방식에 관한 연구)

  • Son, Soon-Yong
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.7
    • /
    • pp.437-442
    • /
    • 2017
  • Previously, studies on compensation material to increase the signal intensity have been conducted which does not affect the reading of images. However, the compensation material has a concern on patient infection as it is attached directly on the skin. Therefore, in this study, we tested an indirect attachment of the compensation material as an alternative method of the direct attachment. The silicon compensation material was fabricated in the form of a cylindrical bar and attached to each element of the 8 channel head coil. Then the signal intensities of the water phantom pre and post application of the silicon were measured. T1 and T2-weighted images were acquired using an 8-channel head coil and a 3.0T superconducting MRI. Signal intensities were measured by using an image measuring program. Paired t-test was used to verify if there were significant differences. The signal intensity before application of the silicon was significantly increased by 3.39% and 2.62% in T1 and T2 weighted images, respectively. Although the indirect attachment method had a limitation to completely replace the existing method, it was considered to be useful in patients with infectious diseases such as diabetic complications since it had a meaningful improvement in signal intensity based on the filling factor increase.

The Relationship between Temporomandibular joint Pain and the Relative Signal Intensity of Retrodiscal Tissue on T1-, and T2-Weighted MRI Images (원판후조직의 T1, T2 강조영상상의 상대적 신호강도와 관절통증의 상관관계)

  • Jung, Jae-Kwang;Hur, Yun-Kyung;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.36 no.3
    • /
    • pp.177-185
    • /
    • 2011
  • Aims: The purpose of this study was to evaluate the relationship between temporomandibular joint pain and the relative signal intensity (RSI) of retrodiscal tissue on T1-, and T2-weighted MRI images. Materials and Methods: This study was based on 122 TMJs of 61 patients who complain of TMJ pain in only one side but were revealed to have disc displacement in both TMJs according to MRI findings. The signal intensities of regions of interest (ROIs) in retrodiscal tissues were measured using T1-, and T2-weighted MRI images. The RSIs of retrodiscal tissues were referenced to the signal intensities of the ROIs of brain gray matter. The relationships between the RSI of retrodiscal tissue and joint pain, joint effusion, condylar degenerative change, and degree of disc displacement were examined. In addition, the relationships between joint pain and joint effusion, condylar degenerative change, and degree of disc displacement were examined. Results: On T1-weighted MR images, the painful TMJs showed significantly higher retrodiscal tissue RSI than non-painful TMJs. In addition, there is an association between joint pain and the degree of disc displacement. However, on T2-weighted MR images, the RSIs of retrodiscal tissues didn't show any significant differences with regard to joint pain, joint effusion, condylar degenerative change, and degree of disc displacement. Conclusions: The signal intensity of retrodiscal tissue can be used as a diagnostic marker for painful TMJ. However, the overall results suggest the signal intensity of retrodiscal tissue has a limited diagnostic significance in determining the pathologic status of TMJ.

The Influence of Energy Density upon Detection Time of Information Signal in AF Track Circuit (AF궤도회로에서 에너지 밀도가 정보신호 검출시간에 미치는 영향)

  • Kim, Min-Seok;Hwang, In-Kwang;Lee, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1146-1151
    • /
    • 2011
  • There are two methods for train control in information transmission by using track circuit system and installing wayside transmitter. Information signal is transmitted to the on-board antenna by using rails. Continuous information about train intervals, speed and route is received by on-board antenna in AF track circuit system. The information signal is included with carrier wave and received by magnetic coupling in the on-board antenna. Therefore, it is important to define standard current level in the AF track circuit system. When current flowed to rails is low, magnetic sensors are not operated by decreasing magnetic field intensity. Hence, SNR is decreased because electric field intensity is decreased. When the SNR is decreased, there is the serious influence of noise upon demodulation. So, the frequency of information signal is not extracted in frequency response. Thus, it is possible to happen to train accident and delay as the information signal is not analyzed in the on-board antenna. In this paper, standard energy density is calculated by using Parseval's theory in UM71c track circuit. Hence, detection time of information signal is presented.