• Title/Summary/Keyword: sign test

Search Result 476, Processing Time 0.027 seconds

Carpal Tunnel Syndrome among workers in a condom industry (한 콘돔공장근로자들의 수근관증후군에 관한 연구)

  • Kang, Joong-Koo;Paek, Do-Myung;Lee, Young-Jung;Ma, Hyeo-Il;Son, Mi-A;Lee, Hong-Ki;Choi, Jung-Keun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.29 no.3 s.54
    • /
    • pp.507-519
    • /
    • 1996
  • The objectives of this study are to investigate the prevalence of occupation related carpal tunnel syndrome(CTS) among workers in a condom industry : to analyse the sensitivity and specificity of clinical signs or symptoms such as hand diagram, Tinel's sign and Phalen's sign in carpal tunnel syndrome : and to test vibration threshold test using audiometry as a technically easy and noninvasive method in the diagnosis of carpal tunnel syndrome in stead of nerve conduction velocity (NCV). The study group was divided into exposed group(39 cases) and non-exposed group(48 cases) based on whether or not excessive use of wrist movements exsist. 1. There are stastically significant differences in symptoms and signs of carpal tunnel syndrome such as hand diagram, Tinel's sign and Phalen's sign between exposed and non-exposed group(p<0.05). 2. Six cases(9 hands) were comfirmed as carpal tunnel syndrome by NCV. Five cases(7 hands) belonged to exposed group, 1 case(2 hands) to nonexposed group. As there are significant differences in prevalence of carpal tunnel syndrome between two groups(p<0.05), excessive use of wrist in occupation is a risk factor of carpal tunnel syndrome. 3. When we use NCV as a gold standard in the diagnosis of carpal tunnel syndrome, sensitivity and specificity of hand diagram, Tinel's sign and Phalen's sign is as followed; hand diagram , sensitivity 88.9%, specificity 84.2% Tinel's sign ; sensitivity 55.6%, specificity 72.8% Phalen's sign ; sensitivity 14.3%, specificity 88.4%. Among above clinical signs and symptoms, hand diagram is the best clinical screening test. 4. The differences of vibration threshold between median and ulnar nerve at the same time are useful in the diagnosis of carpal tunnel syndrome but the time change of vibration threshold of median nerve over time are not sensitive enough. It is concluded that vibration threshold between median and ulnar nerve at the same time can be used as a supplementary or alternative criterion to indicate that the nerve dysfunction is located in the carpal tunnel.

  • PDF

Early Surgical Treatment of Pronator Teres Syndrome

  • Lee, Ho Jin;Kim, Ilsup;Hong, Jae Taek;Kim, Moon Suk
    • Journal of Korean Neurosurgical Society
    • /
    • v.55 no.5
    • /
    • pp.296-299
    • /
    • 2014
  • We report a rare case of pronator teres syndrome in a young female patient. She reported that her right hand grip had weakened and development of tingling sensation in the first-third fingers two months previous. Thenar muscle atrophy was prominent, and hypoesthesia was also examined on median nerve territory. The pronation test and Tinel sign on the proximal forearm were positive. Severe pinch grip power weakness and production of a weak "OK" sign were also noted. Routine electromyography and nerve conduction velocity showed incomplete median neuropathy above the elbow level with severe axonal loss. Surgical treatment was performed because spontaneous recovery was not seen one month later.

DISTRIBUTiON-FREE TWO-SAMPLE TEST ON RANKED-SET SAMPLES

  • DONG HEE KIM;YOUNG CHEOL KIM;MYUNG HWA CHO
    • Communications for Statistical Applications and Methods
    • /
    • v.5 no.1
    • /
    • pp.133-144
    • /
    • 1998
  • In this paper, we propose the two-sample test statistic using Wilcoxon signed rank test on ranked-set sampling(RSS) and obtain the asymptotic relative efficiencies(ARE) of the proposed test statistic with respect to Mann-Whitney-Wilcoxon statistic on simple random sampling(SRS), the Mann-Whitney-Wilcoxon statistic on RSS, sign statistic on RSS and Wilcoxon signed rank test on SRS. From the simulation works, we compare the powers of the proposed test statistic, Mann-Whitney-Wilcoxon statistic on RSS, the usual two-sample t statistic, sign statistic on RSS, where the underlying distributions are uniform, normal, double exponential, logistic and Cauchy distributions.

  • PDF

CNN-based Sign Language Translation Program for the Deaf (CNN기반의 청각장애인을 위한 수화번역 프로그램)

  • Hong, Kyeong-Chan;Kim, Hyung-Su;Han, Young-Hwan
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.22 no.4
    • /
    • pp.206-212
    • /
    • 2021
  • Society is developing more and more, and communication methods are developing in many ways. However, developed communication is a way for the non-disabled and has no effect on the deaf. Therefore, in this paper, a CNN-based sign language translation program is designed and implemented to help deaf people communicate. Sign language translation programs translate sign language images entered through WebCam according to meaning based on data. The sign language translation program uses 24,000 pieces of Korean vowel data produced directly and conducts U-Net segmentation to train effective classification models. In the implemented sign language translation program, 'ㅋ' showed the best performance among all sign language data with 97% accuracy and 99% F1-Score, while 'ㅣ' showed the highest performance among vowel data with 94% accuracy and 95.5% F1-Score.

Antigenicity of HRccine (HFRS-vaccine) in Guinea Pigs and Mice (기니픽과 마우스에서 HRccine(HFRS 바이러스 백신)의 항원성 시험)

  • 백영옥;손정진;안세헌;김태성;이상옥;이영수;조정식
    • Toxicological Research
    • /
    • v.11 no.1
    • /
    • pp.157-159
    • /
    • 1995
  • A study on antigenicity of HRccine (formalin inactivated HFRS virus vaccine) was investigated in guinea pigs and mice. As a part of the safety evaluation of the HRccine, antigenicity tests were carried out according to the Estabilish Regulations of National Institute of Safety Research. In active systemic anaphylaxis (ASA) test no sign was detected when sensitized with up to 120 clinical dose and challenged with up to 1200 clinical dose in guinea pigs. In passive systemic anaphylaxis test guinea pigs showed no sign. In passive cutaneous anaphylaxis (PCA) test, HRccine specific IgE antibody was not detected when sensitized and challenged with up to 1200 clinical dose. Conclusively, there was no adverse antigenic potential at the clinical dose of 120 clinical dose alone and 120 clinical dose with Al(OH)3.

  • PDF

Rapid Screening of Salmonella spp. Using PBM BioSignTM Salmonella Test and Evaluation of the PBMS Test

  • Lim, J.Y.;Kwon, N.H.;Kim, J.M.;Jung, W.K.;Park, K.T.;Hong, S.K.;Park, Y.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.12
    • /
    • pp.1746-1750
    • /
    • 2004
  • The PBM ${BioSign}^{TM}$ Salmonella (PBMS) test kit based on an mmunochromatographic method was evaluated for the screening of Salmonella spp. in pure cultures, and 80, 15, and 10 artificially and naturally contaminated, and negative controlled food samples, respectively. The PBMS test involves presumptive qualitative procedures, detecting the presence of Salmonella spp. in foods within 26 h total testing period and allowing the user to release negative products 70 h earlier than the conventional methods. The PBMS test using Buffered Peptone Water and Rappaport-Vassiliadis broth was evaluated for 10 different food types for various Salmonella spp. It showed detection limits of 1 to 25 colony forming units (CFU)/25 g. No cross-reaction was observed, particularly to other gramnegative bacteria. These results indicate the PBMS test is a rapid and inexpensive procedure for the screening of Salmonella spp. present at low concentrations (1 to 25 CFU/25 g) in foods.

Breakaway Fracture Energy(BFE) of Indented Type Bolt for Breakaway Sign Supports (분리식 지주 단부장치에 이용되는 인덴티드 타입 볼트의 분리파괴에너지)

  • Ko, Man-Gi;Kim, Kee-Dong;Jun, Sung-Min;Sung, Jung-Gon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.4
    • /
    • pp.39-45
    • /
    • 2008
  • Breakaway support for small signs of size $0.293\;m^2{\sim}0.360\;m^2$ using indented tube type bolt of D12 mm with 6 mm inner diameter has been developed and the structural strength of the support system for the wind load was verified through static shear and tension tests. One important value in understanding the dynamic behavior of sign post and impact vehicle is the fracture energy of the sign support. In this study, fracture energy needed to break the sign support was estimated by pendulum test and computer simulation using LS-DYNA program. Support system composed of 3 indented bolts was found to sustain the 43.1 kg$\sim$51.2 kg wind load safely. Fracture energy for one indented bolt was measured as 163.3J from the pendulum test, and was calculated as 153J from the LS-DYNA simulation. The closeness between these two values verified the validity of the simulation model.

Real-time Sign Language Recognition Using an Armband with EMG and IMU Sensors (근전도와 관성센서가 내장된 암밴드를 이용한 실시간 수화 인식)

  • Kim, Seongjung;Lee, Hansoo;Kim, Jongman;Ahn, Soonjae;Kim, Youngho
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.4
    • /
    • pp.329-336
    • /
    • 2016
  • Deaf people using sign language are experiencing social inequalities and financial losses due to communication restrictions. In this paper, real-time pattern recognition algorithm was applied to distinguish American Sign Language using an armband sensor(8-channel EMG sensors and one IMU) to enable communication between the deaf and the hearing people. The validation test was carried out with 11 people. Learning pattern classifier was established by gradually increasing the number of training database. Results showed that the recognition accuracy was over 97% with 20 training samples and over 99% with 30 training samples. The present study shows that sign language recognition using armband sensor is more convenient and well-performed.

Robust Unit Root Tests with an Innovation Variance Break

  • Oh, Yu-Jin
    • Communications for Statistical Applications and Methods
    • /
    • v.19 no.1
    • /
    • pp.177-182
    • /
    • 2012
  • A structural break in the level as well as in the innovation variance has often been exhibited in economic time series. In this paper we propose robust unit root tests based on a sign-type test statistic when a time series has a shift in its level and the corresponding volatility. The proposed tests are robust to a wide class of partially stationary processes with heavy-tailed errors, and have an exact binomial null distribution. Our tests are not affected by the size or location of the break. We set the structural break under the null and the alternative hypotheses to relieve a possible vagueness in interpreting test results in empirical work. The null hypothesis implies a unit root process with level shifts and the alternative connotes a stationary process with level shifts. The Monte Carlo simulation shows that our tests have stable size than the OLSE based tests.