• Title/Summary/Keyword: side weir

Search Result 69, Processing Time 0.024 seconds

Flow Characteristics of a Side-Weir in Rectangular Channel (구형 수로내 횡월류 흐름의 특성)

  • Park, Tae-Seon
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.3
    • /
    • pp.251-259
    • /
    • 2002
  • Flow characteristics occurring a side-weir overflow in rectangular channel is investigated in this study. A numerical model based on the two -dimensional shallow-water equations is employed to review the factors influencing on the side- weir overflow discharge and the change of flow depths and velocities. It is found that the discharge coefficient which has the most significant influence on the overflow is affected by geometric characteristics of a side-weir, Froude number of the main channel flow and the flow depth of the main channel at the starting point of a side-weir. And the discharge coefficient applicable to a practical design of a side-weir is proposed by deriving a relationship between Froude number of the main channel flow at the starting point of a side-weir and Froude number of the main channel flow.

Development of Discharge Formula for Broad Crested Side Weir (광정횡월류위어의 월류량 산정식 개발)

  • Park, Moon-Hyung;Rhee, Dong-Sop
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.6
    • /
    • pp.525-531
    • /
    • 2010
  • In this study, the effects of upstream Froude number ($Fr_1$), weir height (h), weir length (L), weir width (W) and main channel width (B) on the discharge coefficient of broad crested side-weirs in a relatively wide rectangular open channel were investigated experimentally. Furthermore the relationship between discharge coefficients of sharp crested side weir and broad crested side weir was studied using the concept of De Marchi discharge coefficient. The effect of $Fr_1$ on the relationship between discharge coefficients of sharp crested side weir and broad crested side weir is decreased in wide open channel and the relative importance of other influential parameters like h/$y_1$, L/B, and W/($y_1-h$) are increased. New estimated equations for the discharge coefficients of broad crested side weir are suggested from regression analysis with the experiment data sets.

An Estimation of discharge Coefficient for Broad Crested Side Weir (광정횡월류위어의 유량계수 산정)

  • Yoon, Yeong Bae;Cho, Hong Je
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.1B
    • /
    • pp.63-70
    • /
    • 2011
  • To install the side weirs in inlet of washland construction, it is necessary to calculate more accurately the discharges over side weir. In this study, the hydraulic experiments were performed in broad crested side weirs that installed trapezoidal channel and that considered more applicable to the actual river. Upstream Froude number in the main channel and weir height, length, width and slope of main channel were considerd for estimation of discharge coefficient of broad crested side weir. Experimental results show that the discharge coefficient of broad crested side weir depend on, and. New estimated equation for the discharge coefficient are suggested through the multiple regression analysis and its applicability is confirmed by comparing estimated and measured discharges over side weirs.

An Estimation of Discharge Coefficients with the Variations of Side Weir Shape (횡월류위어의 형상에 따른 유량자수 추정)

  • Song, Jai-Woo;Park, Sung-Sik;Kim, Ji-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.1 s.174
    • /
    • pp.51-62
    • /
    • 2007
  • To estimate more accurately the outflow over a sharp crested side weir, it is necessary to analyze the flow characteristics over side weir and to estimate the discharge coefficient in the weir equation. The purpose of this study is to estimate the discharge coefficients of sharp crested rectangular and triangular side weirs by means of hydraulic model experiments with the variations of upstream Froude number in the main channel and length and apex angle. Experimental results show that the discharge coefficients depend on the shape and geometric conditions of side weir as well as the upstream Froude number in the main channel. Through the multiple regression analysis, formulas of discharge coefficient for rectangular and triangular types are proposed and its applicability is confirmed by comparing estimated and measured discharges over side weirs.

Determine the Length of the Side-Weir of Side-Weir Detention Basin Considering the Uncertainty of the Water Level in River (하천 수위 예측의 불확실성을 고려한 강변저류지 횡월류부 길이 결정 기법)

  • Kim, Seojun;Kim, Sanghyuk;Yoon, Byungman
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.8
    • /
    • pp.673-683
    • /
    • 2015
  • The existing flood protection in rivers has shown the limitation due to the urbanization around rivers and the abnormal climate. Thus, the demand for the constructions of side-weir detention basin are being increased as a part of integrated watershed flood protection plan. It is necessary to estimate the quantitative flood-control effect for including the side-weir detention basin in flood-control measures. For the determination, it is required to reduce the uncertainty of the design factors which can affect the flood-control effect of side-weir detention basin. Among the factors, however, the water level in river always contains uncertainty. Therefore, the design method considering the uncertainty is required. For the reasons, the design method considering uncertainty of the water level in river is suggested in this study with using the length of side-weir which is relatively easy-determinable by designers. Therefore, it is examined how the variation of the length of side-weir can affect the flood-control effect, using HEC-RAS, and then the method to determine the side-weir length considering the uncertainty of the water level in river through results from analyses. Since the uncertainty of the water level in river can be taken into account in the suggested design method, it is evaluated that the design method is more effective to suggest the flood-control effect of the side-weir type detention basin with higher safety side.

Analysis of the Flow over Broad Crested Side Weir by Using Three-Dimensional Numerical Simulation (3차원 수치모의를 이용한 광정횡월류위어의 흐름특성 해석)

  • Kim, Dae-Geun;Kim, Yong-Geun
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.3
    • /
    • pp.277-286
    • /
    • 2007
  • In this study, we analyzed the flow characteristics in the wide-crested side weir of trapezoidal section by using a three dimensional numerical stimulation. From this study, as the Froude number increases in the main channel, the overflow discharge ratio and the discharge coefficient of lateral overflow tend to decrease. And it was also found that the increase of the lateral overflow reduces the channel discharge area in the downstream, and the size of recirculating zone is increasing in the opposite side of side weir. The stream-wise water surface on the side where the side weir is installed falls down rapidly in the weir starting point, gradually ascending, and rapidly rising at the end point. The reason why the water surface rapidly rises at the weir end point is because the weir end point hinders the flow.

Discharge Coefficient of Side Weir for Various Curvatures Simulated by FLOW-3D (FLOW-3D를 이용한 다양한 곡률에 대한 횡월류 위어의 유량계수 산정)

  • Jeong, Chang Sam
    • Journal of Korean Society of Disaster and Security
    • /
    • v.8 no.1
    • /
    • pp.5-13
    • /
    • 2015
  • In this study, the lateral overflow discharge coefficients for the curvatures of side weir on meandering channel were analyzed. The side weir installed in accordance with the variation of the radius of curvature of the central angle bends with $180^{\circ}$. FLOW-3D model is applied to calculate the discharge coefficients of the side-weir on meandering and straight channels and the characteristics of the discharge coefficients are analysed. In order to verify the numerical model, the results from the hydraulic experiment conducted by the former research are compared with the results simulated by FLOW-3D in the same conditions. The discharge coefficients are calculated for the ratio between curvature ($R_c$) and channel width (b), and the ratio between over flow discharge of the straight channel ($Q_{wc}$) and the meandering channel ($Q_{wc}$) are compared. As the result, the discharge coefficients depend on the weir depth on upstream, and the radius of curvature, so that the discharge coefficients of side weir on the meandering channel can be estimated by them on the straight channel.

Evaluation of Discharge Coefficients for Sharp Crested Side Weir in Wide Channel (폭이 넓은 개수로에서의 예연횡월류위어 유량계수 산정)

  • Lee, Dong Sop;Kim, Chang Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5B
    • /
    • pp.449-458
    • /
    • 2008
  • This study is investigating experimentally the effect of upstream Froude number, weir height, weir length, and main channel width on the discharge coefficient of rectangular sharp crested side-weirs under subcritical flow conditions in a relatively wide rectangular open channel based on the De Marchi discharge coefficient $C_M$. The effects of four main influential parameters found by dimensional analysis, $Fr_1$, $h/y_1$, L/B, and $L/y_1$ are examined by the flume tests. New estimated equations for the discharge coefficients of sharp-crested side-weir are suggested based on the experimental results. The effect of $Fr_1$ for the discharge coefficient of sharp crested side weir is decreased in wide open channel and the relative importance of other influential parameters like $h/y_1$, L/B, and $L/y_1$ are increased. Also, the experimental results are compared with the results of other studies to extend the applicability of pre-suggested formulas for sharp-crested side-weir discharge coefficient.

Feasibility Analysis of HEC-RAS for Unsteady Flow Simulation in the Stream Channel with a Side-Weir Detention Basin (강변저류지가 있는 하도에서의 부정류 흐름 모의를 위한 HEC-RAS의 적용성 검토)

  • Kim, Seo-Jun;Hong, Sang-Jin;Yoon, Byung-Man;Ji, Un
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.5
    • /
    • pp.495-503
    • /
    • 2012
  • It is necessary to perform the precise analysis of unsteady flow for effective design of the side-weir detention basin installed in the river. Generally, the HEC-RAS program, which is a 1D unsteady numerical model, is mostly used to simulate the unsteady flow for rivers. However, it is difficult to have confidence of unsteady flow results simulated by HEC-RAS due to the lack of experimental data and field monitoring data for the channel with a side-weir detention basin. Therefore, the purpose of this study is to validate or verify the simulation results calculated by HEC-RAS through the experiments for the open channel with a side-weir detention basin using specially-designed unsteady discharge-supply system. The experimental cases included unsteady flows in the straight channel with and without a side-weir detention basin. Especially, for the case with a detention basin, the experiment was performed to consider only the free flow condition over the side-weir. The study results showed that values of water level and discharge obtained from HEC-RAS coincided reasonably with experimental results with the maximum error of 3% for water level and 1% for discharge in the case of the flow without the side-weir detention basin and 4% for water level and 2% for discharge with the side-weir detention basin.

Effects of the water level reduction and the flow distribution according to change of the side weir location in detention reservoir (홍수조절지 횡월류위어의 위치 변화에 따른 수위 저감 및 유량 분담 효과)

  • Seong, Hoje;Park, Inhwan;Rhee, Dong Sop
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.7
    • /
    • pp.555-564
    • /
    • 2018
  • The detention reservoir is a hydraulic structure that constructs a levee on the inland of river and sets up side weir in a section of the levee, and this facility stores a part of the flood volume in case of a flood event over a certain scale. In order to optimize the operation of detention reservoir, it is necessary to review the linkage with existing facilities in the river. In this study, the effect of water level reduction and the flow distribution was analyzed according to the location of the side weir in the detention reservoir considering the run-of-the-river gate. Two radial gates were installed in the experimental channel, and the water level in channel and the overflow of weir were measured by moving the location of the side weir upstream from the gate. As a results of experiment, it was confirmed that the water level reduction is more remarkable as the location of the side weir was closer to the gate, and the effect of flow distribution is not greatly changed. When two or more side weirs were operated, it is confirmed that the sufficient storage space was secured and the water level reduction effect with the location of the side weir is not large. In addition, the water level reduction rate according to the location of the side weir was estimated by empirical formula and it is provided as basic data that can be used in the planning of the detention reservoir.