• Title/Summary/Keyword: shrinkage cracking

Search Result 245, Processing Time 0.037 seconds

Cracking Behavior of Concrete Box Culvert for Power Transmission Due to Drying Shrinkage (전력구 콘크리트 구조물의 건조수축 균열특성에 관한 연구)

  • Woo, Sang-Kyun;Chu, In-Yeop;Kim, Ki-Jung;Lee, Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • The purpose of this study is to predict the cracking behavior and suggest the method of controlling the cracking in concrete box culvert for power transmission due to differential drying shrinkage. Drying shrinkage cracking is mainly influenced by the moisture diffusion coefficient that determines moisture diffusion rate inside concrete structures. In addition to the diffusion coefficient, surface coefficient of concrete surface and relative humidity of ambient air simultaneously affect the moisture evaporation from concrete inside to external air outside. Within the framework of drying shrinkage cracking mechanism, it is necessary to perform the numerical analysis, which involves these three influencing factors to predict and control the shrinkage cracking of concrete. In this study, moisture diffusion and stress analysis cor responding to drying shrinkage on concrete box culvert are performed with consideration of diffusion coefficient, surface coefficient, and relative humidity of ambient air. From the numerical results, it is found that cracking behavior due to differential drying shrinkage of box culvert shows the different feature according to three influencing factors and the methodology of controlling of drying shrinkage cracks can be suggested from this study.

Cracking Behavior of Concrete Bridge Deck Due to Differential Drying Shrinkage (교량 바닥판 콘크리트의 부등건조수축 균열특성에 관한 연구)

  • Yang, Joo Kyoung;Lee, Yun;Yang, Eun Ik;Park, Hae Geun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.4A
    • /
    • pp.329-335
    • /
    • 2009
  • The purpose of this study is to provide the efficient method and guideline of controlling the cracking in bridge deck concrete due to differential drying shrinkage. Drying shrinkage cracking is mainly influenced by the moisture diffusion coefficient that determines moisture diffusion rate inside concrete structures. In addition to the diffusion coefficient, surface coefficient of concrete surface and relative humidity of ambient air simultaneously affect the moisture evaporation from concrete inside to external air outside. Within the framework of cracking shrinkage cracking mechanism, it is necessary to conceive the numerical analysis, which involves these three influencing factors to predict and control the shrinkage cracking of concrete. In this study, moisture diffusion and stress analysis corresponding to drying shrinkage on bridge deck are performed with consideration of diffusion coefficient, surface coefficient, and relative humidity of ambient air. From the numerical results, it is found that cracking behavior due to differential drying shrinkage of bridge deck concrete shows different feature according to three influencing factors and the methodology of controlling of drying shrinkage cracks can be suggested from this study.

A Numerical Study on the Characteristics of Plastic Shrinkage Cracking on Concrete Slab with Sequential Placement (분할타설되는 콘크리트 슬래브의 소성수축균열 특성에 대한 해석적 연구)

  • Kwak, Hyo-Gyoung;Ha, Soo-Jun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.795-808
    • /
    • 2006
  • In this paper, an analytical method which can predict the occurrence of plastic shrinkage cracking on concrete slabs with sequential placement is proposed on the basis of the numerical model introduced in the previous study. The influence of many design variables on plastic shrinkage cracking such as the number of layers and the time interval between layers is quantitatively analyzed through parametric studies using the analytical method. In advance, two equations are introduced to take into account the effect of sequential placement on the plastic shrinkage cracking of concrete slab; The first one is to calculate the time at which the surface of concrete slab begins to dry, and the second one is to determine the critical time interval to prevent the surface drying of previously placed concrete layers. The timing of curing and the sequence of concrete placement, which are important for the prevention of plastic shrinkage cracking, can be effectively planned using the introduced both equations without any rigorous analysis.

Properties of Plastic Shrinkage Crack Occurrence on The LMC Bridge Deck Overlays (LMC(Latex Modified Concrete) 교면포장에서의 소성수축 균열발생 특성)

  • Park, Sung-Ki
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.265-268
    • /
    • 2004
  • Plastic shrinkage cracking is a major concern for concrete, especially for flat structures as highway pavement, bridge deck slabs, and bridge deck pavement. LMC(Latex Modified Concrete) be used mainly for bridge deck overlays, so occurrence possibility of plastic shrinkage cracking is very high. But LMC is form a close-packed layer of polymer particles in very early time from the time of adds the latex and water. So plastic shrinkage cracking compare with normal concrete is not occur at final setting time. Results indicates that LMC is advantage to prevent occurrence of plastic shrinkage crack and it's possible co construction for bridge deck overlay effectively.

  • PDF

Drying Shrinkage Cracking of Concrete used Very Fine Sand (미립 잔골재를 혼입한 콘크리트의 건조수축 균열 특성)

  • Lee, Eui-Bae;Park, Sang-Jun;Kim, Kyoung-Min
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.90-91
    • /
    • 2014
  • In this study, the effect of very fine sand on drying shrinkage cracking of concrete was experimentally evaluated. As a result of the study, the time-to-cracking of concrete used very fine sand was shorter than plain concrete. Also, the stress rate of concrete used very fine sand was higher than plain concrete. It was due to the increase of water content when very fine sand was used in concrete. In conclusion, the use of very fine sand can lead the increase of water content to meet the target slump and higher potential of cracking of concrete.

  • PDF

Hydration Model of Ettringite-Gypsum Type Expansive Additive (에트링가이트-석회 복합계 팽창재의 수화반응 모델화)

  • Park Sun Gyu;Noguchi Takahumi;Song Ha Won;Kim Moo Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.683-686
    • /
    • 2004
  • In recent years, some attention was particularly given to cracking sensitivity of high performance concrete. It has been argued and demonstrated experimentally that such concrete undergoes autogenous shrinkage due to self-desiccation at early age, and, as a result, internal tensile stress may develop, leading to micro cracking and macro cracking. One possible method to reduce cracking due to autogenous shrinkage is the addition of expansive additive. Tests conducted by many researches have shown the beneficial effects of addition of expansive additive for reducing the risk of shrinkage-introduced cracking. However, the research on hydration model of expansion additive has been hardly researched up to now. This paper presents a study of the hydration model of Ettringite-Gypsum type expansive additive. Result of comparing forecast values with experiment value, proposed model is shown to expressible of hydration of expansive additive.

  • PDF

Effect of Admixtures on Drying Shrinkage Crack of Hardened Cement Mortar (시멘트경화체의 건조수축균열에 미치는 혼화재의 영향)

  • 이승한;이종석
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.10a
    • /
    • pp.229-233
    • /
    • 1995
  • In this study we have the properties of drying shrinkage crack of hardened cement mortar using admixtures. The drying shrinkage cracking test process has been examined by the restrained drying shrinkage strain by restraining rate measuring properties of strain-with- restraint by JIS original proposal and keeps a flow value of mortar about 100$\pm$5%. The results show that the usage of shrinkage reducing agent 1.5% was effective on the control of drying shrinkage in OPC and CP by restraining rate 20% and strain-with-restraing 20~30 $\mu$, the usage of expansion agent 0.45% was effective by restraining rate 50~60% and strain-with-restraint 40~80$\mu$, and the effectiveness was increased with shrinkage reducing agent. Also. admixtures such as Flyash, CP and NC reduced restrained shrinkage and drying shrinkage cracking and more with shrinkage reducing agent

  • PDF

Effect of Recycled PET Fiber Geometry and Length on the Plastic Shrinkage Cracking of Cement Based Composites (재생 PET 섬유의 형상 및 길이가 시멘트 복합 재료의 소성 수축 균열에 미치는 영향)

  • Won, Jong-Pil;Park, Chan-Gi;Kim, Hwang-Hee;Lee, Sang-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.233-239
    • /
    • 2007
  • The main objective of this study was to evaluate the effect of recycled PET fiber made from waste PET bottle on the control of plastic shrinkage cracking of cement based composites. PET is blown as a plastic material and used in a variety products such as a beverage bottle. However, waste PET bottles are thrown after the usage, raising huge problems in terms of the environment. Thus, the research on the method to recycle the PET bottles indicates important aspects in environment and economy. The method to recycle waste PET bottles as a reinforcing fiber for cement based composites is one of effective methods in terms of the recycle of waste PET bottles. In this research, the effect of recycled PET fiber geometry and length on the control of plastic shrinkage was examined through thin slab tests. A test program was carried out to understand the influence of fiber geometry, length and fiber volume fraction. Three type of recycled PET fibers including straight, twist crimped and embossed type. Three volume fraction and two fiber length were investigated for each of the three fiber geometry. Test results indicated that recycled PET fibers are effective in controlling plastic shrinkage cracking in cement based composites. In respect to effect of length of fiber, longer fiber was observed to have efficient cracking controlling with low volume fraction in same fiber geometry while shorter fiber controled plastic shrinkage cracking efficiently as addition rate increase. Also, embossed type fibers were more effective in controlling plastic shrinkage cracking than other geometry fiber at low volume fraction. But, for high volume fraction, straight type fibers were most effective in plastic shrinkage cracking controlling in cement based composites.

Tensile Creep Properties of Concrete under Restrained Shrinkage (구속수축에 의한 콘크리트 인장크리프 특성)

  • Choi, Hoon-Jae;Seo, Tae-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.28-29
    • /
    • 2016
  • By Testing restrained shrinkage, it is possible to estimating the cracking tendency of concrete such as time to cracking, tensile stress and tensile creep. In this study, tensile creep properties of concrete under restraint shrinkage were investigation through comparison of specimens that JIS and AASHTO proposed. As a results, tensile creep strains in concrete ring specimens were 15% higher than those in uniaxial specimens.

  • PDF

Autogenous Shrinkage of Concrete Containing Blast-Furnace Slag (고로 슬래그를 함유한 콘크리트의 자기 수축)

  • 이회근;권기헌;이광명;김규용;손유신
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.417-420
    • /
    • 2003
  • Concrete with low water to binder ratio (W/B) is prone to large autogenous shrinkage. Early age cracking of concrete would be caused by tensile stress induced by large autogenous shrinkage under restrained condition. Therefore, it is necessary to measure autogenous shrinkage to control the early age cracking of concrete. An objective of this study is to investigate the effects of W/B and blast furnace slag (BFS) on autogenous shrinkage of concrete. Autogenous shrinkage of concrete with various W/B ranging from 0.42 to 0.27 and BFS contents of 0, 30 and 50% were measured. Test results show that the autogenous shrinkage of concrete increases as the W/B decreases, and all BFS concretes showed larger autogenous shrinkage than OPC concretes with the same W/B. Moreover, the higher BFS content, the larger autogenous shrinkage.

  • PDF