• 제목/요약/키워드: shrinkage control

검색결과 348건 처리시간 0.024초

현장적용을 통한 초 저수축 콘크리트의 성능 검토 (Performance review of ultra-low shrinkage concrete by field application)

  • 김강민;이현승;서태석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2022년도 가을 학술논문 발표대회
    • /
    • pp.211-212
    • /
    • 2022
  • In this study, the cracking control performance of ultra-low shrinkage concrete was investigated by the field application. As a result, drying shrinkage crack occurred in normal concrete wall, but no crack occurred in ultra-low shrinkage concrete wall. It is determined that the drying shrinkage crack control effect of the ultra-low shrinkage concrete is excellent.

  • PDF

목재(木材)의 치수변동(変動)에 관(關)한 연구(硏究) (Study on Movement of Wood)

  • 정희석;이필우;이남호
    • Journal of the Korean Wood Science and Technology
    • /
    • 제14권2호
    • /
    • pp.36-42
    • /
    • 1986
  • Both the control and heated specimen of oak, hornbean, alder, poplar, red pine and pitch pine among domestic commercial species and taun imported were used for radial and tangential shrinkage and movement that occurred on changing the relative humidity of the atmosphere from 90 percent to 60 percent at $25^{\circ}C$. The results of this study were as follows. 1. The radial and tangential shrinkage of the control and heated hornbean and oak wood, except alder, of high specific gravity showed greater than species with low specific gravity. The ratio of tangential to radial shrinkage was 1.46 for taun to 2.70 for alder. Green volume specific gravity of the heated and soaked specimen of all species except poplar decreased 1.5 to 3.1 percent. Shrinkage of the heated specimen increased more than that of the control specimen, and antishrink efficiency of all timbers except alder had negative value. Shrinkage from green to air dry of treated specimens increased more than case of total shrinkage, and radial shrinkage of those specimen increased greater than tangential shrinkage. 3. The movement of the heating specimen for 120 hours decreased than those of the control and the heating specimen for 240 hours. The movement of heating oak, poplar, red pine and pitch pine (or 240 hours increased rather than those of the control specimen.

  • PDF

초 저수축 콘크리트의 수축특성에 관한 실험적 연구 (An Experimental Study on the Shrinkage Properties of Ultra-Low Shrinkage Concrete)

  • 서태석;김강민;이현승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.148-149
    • /
    • 2021
  • In Japan, ultra-low shrinkage concrete has been developed and commercialized to control drying shrinkage cracks to the limit. However, in the case of South Korea, the study on this technology has not yet been conducted in earnest. Therefore, the study was conducted for the development of ultra-low shrinkage concrete to control the drying shrinkage crack of concrete to the limit, and in this study, after determining the mixture of ultra-low shrinkage concrete, a wall type mock-up specimen was produced to observe the shrinkage behavior of ultra-low shrinkage concrete.

  • PDF

초기강도 섬유보강 콘크리트의 수축특성 (Shrinkage Properties of High Early Strength Fiber Reinforced Concrete)

  • 원종필;김현호
    • 한국농공학회지
    • /
    • 제43권5호
    • /
    • pp.124-131
    • /
    • 2001
  • The shrinkage properties of high early strength concrete were investigated. One of the method to control microcrack and crack development due to restrained shrinkage is to reinforce concrete with randomly distributed fibers. Regulated-set cement and two different types of fiber were adopted. The experiments for heat of hydration, drying and autogenous shrinkage were conducted. The desirable resistance of high early strength fiber reinforced concrete to restrained shrinkage microcracking was achieved. These results indicate that use of fiber in high early strength concrete plays an important role in control of crack development due to restrained shrinkage.

  • PDF

벽체 실물대부재실험을 통한 초 저수축 콘크리트의 균열제어 효과 분석 (Analysis of Crack Control Effect of Ultra-low Shrinkage Concrete through Wall Mock-up Test)

  • 서태석;이현승;김강민
    • 한국건축시공학회지
    • /
    • 제22권1호
    • /
    • pp.45-55
    • /
    • 2022
  • 초 저수축 콘크리트는 콘크리트 구조물의 건조수축 균열을 극한으로 제어할 수 있기 때문에 콘크리트 구조물의 품질 및 외관 확보에 매우 효과적이다. 본 연구에서는 초 저수축 콘크리트의 상용화를 목적으로 실내실험을 통해 최적의 팽창재 및 수축저감제 투입량을 정하였고, 콘크리트 벽체 실물대부재실험을 실시하여 초 저수축 콘크리트의 수축 특성 및 균열제어 효과 등을 검토하였다. 그 결과 벽체 시험체에는 건조수축 변형이 거의 발생하지 않았고 균열도 발생하지 않음을 확인할 수 있었다.

초고강도 강섬유보강 콘크리트의 수축특성 (Shrinkage Properties of Ultra High Strength Steel Fiber Reinforced Concrete)

  • 고경택;배장춘;이건철;강수태;김성욱;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.647-650
    • /
    • 2005
  • This paper is to investigate the shrinkage properties of ultra high strength concrete(UHSC) incorporating $5\%$ of expansive additives(EA) along with $1\%$ of shrinkage reducing agent(SRA). UHSC subjected to steam curing and incorporated with steel fiber exhibited higher compressive strength than control UHSC by as much as50MPa at 7days, while at 28days, noticeable change in compressive strength was not observed between UHSC mixtures. Control UHSC subjected to steam curing had a $922{\times}10^6$ of autogenous shrinkage strain value, which was 6.7 times of drying shrinkage strain value at 42 days. The combination of EA and SRA resulted in a decrease in autogenous shrinkage by as much as half of control mixture. Steam curing contributed to the reduction of autogenous shrinkage by as much as $11\%$ compared with that of standard curing.

  • PDF

Morphological Clustering Filter for Wavelet Shrinkage Improvement

  • Jinsung Oh;Heesoo Hwang;Lee, Changhoon;Kim, Younam
    • International Journal of Control, Automation, and Systems
    • /
    • 제1권3호
    • /
    • pp.390-394
    • /
    • 2003
  • To classify the significant wavelet coefficients into edge area and noise area, a morphological clustering filter applied to wavelet shrinkage is introduced. New methods for wavelet shrinkage using morphological clustering filter are used in noise removal, and the performance is evaluated under various noise conditions.

콘크리트 건조수축 균열제어를 위한 합리적인 최소철근량 (Reasonable Minimum Reinforcement for Crack Control of Concrete Shrinkage)

  • 김수만;오민호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.441-444
    • /
    • 1999
  • The crack width of concrete structures subjected to shrinkage depend on a great number of parameters whose effects are restrain condition, the number and spacing of crack and the amounts of reinforcements. Through suitable reinforcement it is possible to make the individual cracks exceedigly small. This paper is to present the amount of reasonable reinforcement for crack control through a rational analysis of forces occuring in significantly restrained concrete structures due to the shrinkage. Also the analysis results from this paper are compared with the provisions for shrinkage and temperture reinforcement in the KCI concrete strucural design code.

  • PDF

저수축 시멘트 안정처리 기층의 특성분석 (Analysis of Characteristics in Low-shrinkage Cement Treated Base)

  • 이승우;전범준;김종원
    • 한국도로학회논문집
    • /
    • 제6권2호
    • /
    • pp.61-70
    • /
    • 2004
  • 시멘트 안정처리는 우수한 강도발현, 내구성, 강성, 동상저항 등의 우수한 능력을 발휘하지만 건조수축으로 인해 표층부로의 반사균열을 발생시키는 단점을 가지고 친다. 이에 본 연구에서는 시멘트의 건조수축을 억제하여 표층부로의 반사균열을 억제할 수 있는 저수축 시멘트 안정처리기법에 대한 타당성을 연구하였다.

  • PDF

균열제어를 위한 섬유보강 콘크리트의 실용화 연구 (A Study on the Practicality of Fiber Reinforced Concrete to Control Plastic Shrinkage Crack)

  • 정양희;최일호;김욱종;이도범
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.15-18
    • /
    • 2007
  • The purpose of this study is to suggest a reference for an extensive evaluation about effectiveness of four types of fibers to control plastic shrinkage crack of concrete. So in this study for the practical use in construction field, the plastic shrinkage cracks shown from four types of concrete reinforced by mixing four types of fibers are quantitatively evaluated in points of the workability and compressive strength. Test showed that the mixing of Cl, N, P fibers except for C2 fibers decreased fluidity of fresh concrete. Compressive strengths of four types specimens were similar. Plastic shrinkage cracks were reduced by mixing each fiber, especially C2 fibers was very effective to prevent the plastic shrinkage crack. Therefore the reinforced concrete mixed with C2 fibers exhibited superior mechanical performance than the others.

  • PDF