• Title/Summary/Keyword: shower-system

Search Result 50, Processing Time 0.028 seconds

A Study of Behavioral Characteristic of Elders during Showering (고령자의 샤워 시 행동 특성 분석)

  • Park, Kyung-Ryul;Jeong, Woo-Won;Rhee, Kye-Han;Chun, Keyoung-Jin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.7 s.196
    • /
    • pp.120-125
    • /
    • 2007
  • Analysis of elders' behavioral characteristic during showering provides important fundamental data when developing an automatic showering system. We recorded showering behavior of 37 elders' at the front, back, left and right view using four CCTV cameras. The photographic data were analyzed by counting the frequencies of body scrub and identifying zones where hands could reach. And we measured their body sizes, and conducted questionnaire of showering for 302 peoples. Analysis was done according to the analysis criteria established. The human body was divided into 14 zones from a body, and the numbers of body scrub for each zone were counted. The average total numbers of body scrub were 170.8 excluding the head, the face and the neck. The average numbers of body scrub with right hand were 70.2, left hand were 88.2, and both hands were 81.8. The percentages of body scrub frequencies were 16.3% (breast), 12.2%(crotch), 8.8% (abdomen), 7.5% (waist), 8.8% (shoulder), 7% (hips), 0.4% (back), 15.2% (arm), and 23.9% (leg). Elders scrubbed the breast, crotch and abdomen more frequently than the back and hips. According to the video analysis and questionnaire results, the distribution of shower heads (or nozzles) at the front side should be arranged at the ratio of 40% of the trunk(breast, shoulders, abdomen), 20% of the thighs, the calves, and the crotch, respectively. The distribution of shower heads (or nozzles) of the back side were arranged at the ratio of 20% of the waist and the arms, 20% of the back, the thighs, the calves, and the hip, respectively.

Analysis of Thermal Performance of Solar Hot-Water and Heating System with Baffle Storage Tank (태양열이용 Baffle형 축열탱크를 갖는 온수난방시스템의 열성능 해석)

  • Suh, Jeong-Se;Yi, Chung-Seub
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.768-773
    • /
    • 2009
  • A numerical study has been performed to investigate the thermal Performance of Solar heating system with baffle type of storage tank by using the commercial code TRNSYS. As a result, the solar fraction depends strongly on the efficiency and heat loss coefficient of solar collector as well as the heating capacity of house and the water temperature supplied to the shower. In addition, the solar fraction has been basically ranked to higher level in baffle type of storage tank than typical type of single storage tank for the range of operation condition.

  • PDF

Analysis of Thermal Performance of Solar Hot-Water and Heating System with Baffle Storage Tank (태양열이용 Baffle식 축열조를 갖는 급탕난방시스템의 열성능 해석)

  • Suh, Jeong-Se;Yi, Chung-Seub;Yoon, Ji-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.805-811
    • /
    • 2010
  • A numerical study has been performed to investigate the thermal performance of solar heating system with baffle type of storage tank by using the commercial code TRNSYS. As a result, the solar fraction depends strongly on the efficiency and heat loss coefficient of solar collector as well as the heating capacity of house and the water temperature supplied to the shower. In addition, the solar fraction has been basically ranked to higher level in baffle type of storage tank than typical type of single storage tank for the range of operation condition.

Development of Automatic Packing System of One Station for Fasteners(II) : Packing System Manufacture and Performance Test (원 스테이션 파스너 자동포장기 개발(II) : 제작 및 성능검증)

  • Kim, Yong-Seok;Jeong, Chan-Se;Yang, Soon-Young
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.5
    • /
    • pp.653-658
    • /
    • 2011
  • In general, the purpose of packaging fasteners is a series of management activities to maintain the condition at the time of production until they get delivered to the end user. An automatic packing system for fasteners is consisted of bucket conveyor, slide feeder, vision inspection system, box-magazine conveyor system and automatic packing machine. Also, the automatic packing machine is consisted of six modules including charging device, clamping/opening device, sealing/cutting device, feeding/air-shower device, supplying/adjusting device and device frame, etc. In this paper, we proposed an automatic packing mechanism of the one station concept for packing work of fastener objects where the continuous batch work is performed in a finite space. The proposed one-station packing mechanism has been optimized through mechanical, dynamical, structural and fluid analyses. And it had been manufactured as the prototype of automatic packing machine. The field test for validation of performance was performed directly at the production line of bolt and screw. In the field test, this packing machine showed an efficiency of about 4.5 times the manual operation. It also showed 30% reduction in the consumption of packing materials compared to the manual operation. This automatic packing machine for fastener objects will be commercialized soon.

Korean Household’s Level and Standard of Consumption: For Developing Sustainable Lifestyle (한국가계의 소비수준 및 표준:지속가능한 생활양식의 실현 모색)

  • 손상희
    • Journal of Families and Better Life
    • /
    • v.19 no.5
    • /
    • pp.259-277
    • /
    • 2001
  • The purpose of this study was to identify household’s level and standard of consumption and their related variables in order to derive some useful implications for developing sustainable lifestyle. Data were collected from 567 household wives living in Seoul and the five Metropolitan cities in Korea. The results showed that most households owned such goods as central heating system, shower and bath, refrigerator, microwave oven, vacuum cleaner, washer. TV video player, personal computer, mobile phone, and car. They thought that most of the goods were necessary for the desired level of living and has a strong aspiration to buy those goods. This implied a tendency of uniformity in need perceptions and consumption patterns among Korean households. However, level and standard of consumption measured in selected living area differed according to age. education family size, household income, occupation, and the size housing, which showed that different approach was needed for developing sustainable lifestyle according to these variables.

  • PDF

The Effect of Built-Environment Features on Relocation among American Older Persons with Decline in Functional Ability (주택 내 보조설비가 미국 노인들의 생활기능 감소로 인한 주거이동에 미치는 영향)

  • 전경숙
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.161-166
    • /
    • 2002
  • Functional ability is an important criterion to predict the capability of older persons to maintain independent living in the community setting. This study focused on the effect of built-environment features to ameliorate declines in functional ability and reduce the likelihood of relocation. Using longitudinal data from the Asset and Health Dynamics Among the Oldest Old (1993, 1995), relocation was analyzed for 6,225 respondents aged 70 or older. Findings are that while functional decline in household activities of daily living among older persons increased their residential moves in the community, functional declines in basic activities of daily living, household activities of daily living, and advanced activities of daily living among them increased their entrance into an institutional care facility However, they were less likely to enter an institutional care facility when their home was equipped with built-environment features such as street level ramps, special railings, modifications to allow someone in a wheelchair, grab bars or shower seat in the bathroom, and special call device or system to get help.

  • PDF

A Status of Bathroom Planning of Units in Elderly Housing Facilities (노인주거시설 단위주호의 욕실 계획 실태)

  • Ju Seo-Ryeung;Lee Ji-Ye
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.4 s.51
    • /
    • pp.45-53
    • /
    • 2005
  • Compared with a lot of comprehensive and alternative studies on elderly housing facilities until now, specialized studies of dimensional and detailed standards have hardly made. Therefore we intends to examine the status of bathroom planning on representative elderly housing facilities in Korea. As the methods of this study, we executed a field study into five representative elderly housing facilities in Korea. We visited each two units out of the outstanding 5 facilities and surveyed the total ten bathrooms. Then we analyzed the space planning of them and the state of bathroom commodities, and measured the bathroom equipment. In addition, we collected questionnaires about satisfaction, preference, and problems from the residents. As a result, most of the bathrooms had powder rooms and were furnished with bathtubs(4) and shower stalls(6). One or more grab bar and emergency calling system were provided but the heights of the handles were different from each bathroom. The floor material of bathroom should be installed with no-slippery material.

The Survey and its Effect for Cooling Systems used in Dairy Cattle Farms in Gyeonggi (경기지역 젖소 농가 고온저감시설 활용 실태조사 및 축사내 온습도 변화)

  • Lee, Jun-Yeob;Choi, Hee-Cheol;Lee, Dong-Hyun;Woo, Saem-Ee;Ki, Kwang-Seok;Jeon, Jung-Hwan
    • Journal of Animal Environmental Science
    • /
    • v.21 no.2
    • /
    • pp.55-64
    • /
    • 2015
  • This survey was conducted to give the basic information and temperature and humidity variation by cooling systems in dairy farms in Korea. A total of 36 farms were surveyed in Gyeonggi province with the general information of farms such as milk production, and milk quality, types of cooling systems, and its operation method of dairy farms. All of surveyed farms have cooling fan and some have 1 more cooling systems such as sprinkler, foggy systems, ventilation duct, and shower system. Although the indoor THI of cow house was decreased by either ventilation duct or foggy system during hot season, the range belongs to mild heat stress scale for dairy cows.

Change of Venous Pressure of Superficial Vascular System during Free TRAM Flap Elevation (유리횡복직근피판에서 거상 전후의 피하정맥압의 변화)

  • Kim, Ki Kap;Chang, Hak;Minn, Kyung Won
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.60-63
    • /
    • 2007
  • Purpose: Free transverse rectus abdominis musculocutaneous(TRAM) flap is one of the most popular methods of breast reconstruction. But if fat necrosis and fatty induration occur at the reconstructed breast, they can make the breast harder and make it difficult to differentiate a tumor recurrence from them. To expect and prevent these complications, we measured the pressure change of the superficial venous system whose congestion can be the cause of them. Methods: An intraoperative clinical study was done to compare venous pressure of superficial inferior epigastric vein(SIEV) before and after the elevation of free TRAM flap. Fourteen TRAM flaps were included and the pressures of SIEV were measured two times at the beginning of the elevation and just before the division of the inferior pedicle. Results: The venous pressure in free TRAM flap was significantly higher after the flap elevation at both contralateral side and ipsilateral(p=0.005 and p=0.026 respectively). The four cases with vertical scar shower significantly greater increase at contralateral side than ipsilateral side(p=0.020). Conclusion: Intraoperative venous pressure recording can be an objective data for evaluating the congestion of TRAM flap and can help to prevent the complications of fat necrosis and fatty induration with venous superdrainage.

A Study on simulation analysis of the microbe transport of air-born virus in hospital for microbiological safety (미생물 안전을 위한 병원건물의 환기설계에 따른 공기 감염균 확산에 관한 시뮬레이션 연구)

  • Choi, Sang-Gon
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.115-123
    • /
    • 2017
  • Recently there is a growing interest in the airborne spread of virus. In particular, there is growing interest in secondary infection through the air in the hospital. The distribution of air-born virus depends on ventilation system installed in a hospital. In this study, simulations were carried out to predict the move of air-born virus by ventilation system at hospital. Simulation results showed that pressure distribution was -372.05Pa ~ -3.45 Pa at 1st floor incase of only used mechanical exhaust at bathroom, shower stall, storage, kitchen etc.. if ventilation switch from used mechanical exhaust to mechanical exhaust & mechanical supply. Simulation results showed that pressure distribution was -336.44Pa at stair hall < -0.2Pa at bathroom < mean 1.19Pa at other room. So simulation results showed that using all of the mechanical supply and mechanical exhaust was more effective then the mechanical exhaust for maintain the pressure distribution in hospital. It was also showed that when using the mechanical supply and mechanical exhaust more effectively prevention of air born virus diffusion.