• Title/Summary/Keyword: short current

검색결과 2,895건 처리시간 0.037초

고휘도 Short-Arc 램프용 전자식 안정기 설계 및 제작 (The Design and Fabrication of an Electronic Ballast for High Intensity Short-Arc Lamps)

  • 김일권;박대원;이성근;길경석
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.304-309
    • /
    • 2005
  • This paper presents an electronic ballast using a step down converter, a low frequency inverter for high intensity short-arc discharge lamp. The proposed ballast is composed of a full-wave rectifier, a step down converter operated as a current source with power regulation and a low frequency inverter with external ignition circuit. The ignition circuit generates high voltage pulse of $3{\sim}5[kV]$ peak, 130[Hz] periodically. Moreover, it is able to reignite at regular intervals by protective circuit. As experimental results on the test, acoustic resonance phenomenon is eliminated by operating the low frequency square wave voltage and current. Lamp voltage, current and consumption power are measured 123.8[V], 8.1[A] and 1,002[W], respectively. It was confirmed that the designed ballast operate the lamp with a constant power.

  • PDF

IGBT 인버터를 위한 향상된 단락회로 보호기법 (An Improved Short Circuit Protection Scheme for IGBT Inverters)

  • 서범석;현동석
    • 전력전자학회논문지
    • /
    • 제3권4호
    • /
    • pp.426-436
    • /
    • 1998
  • Identification of fault current during the operation of a power semiconductor switch and activation of suitable remedial actions are important for reliable operation of power converters. A short circuit is a basic and severe fault situation in a circuit structure such as voltage source converters. This paper presents a new active protection circuit for fast and precise clamping and safe shutdown of fault currents of the IGBTs. This circuit allows operation of the IGBTs with a higher on-state gate voltage, which can thereby reduce the conduction loss in the device without compromising the short circuit protection characteristics. The operation of the circuit is studied under various conditions, considering variation of temperature, rising rate of fault current, gate voltage value, and protection circuit parameters. An evaluation of the operation of the circuit is made using IGBTs from different to confirm the effectiveness of the protection circuit.

  • PDF

단1차 단2차 편측식 선형 유도전동기의 유한요소법에 의한 2차측 와전류 분포해석에 관한 연구 (A Study on the Secondary Side Eddy Current Distribution Analysis of a Short Primary-Short Secondary Single-Sided LIM by the Finite Element Method)

  • 임달호;조윤현
    • 대한전기학회논문지
    • /
    • 제39권5호
    • /
    • pp.453-461
    • /
    • 1990
  • In this paper, a short primary-short secondary single-sided linear induction motor which is used as the driving source for an automatic conveyor system, is selected as an analysis model. The finite element method in which the current vector potential is introduced is adopted to analyze the eddy current distribution and thrust force which are produced according to the relative position of the primary and the secondary. Also, the analysis results are compared with experimental ones, to show the propriety of this model.

  • PDF

경년열화에 따른 배선용 차단기류의 고장점 분석 연구 (A Study on Failure Analysis of Low Voltage Breakers with Aging)

  • 조한구;이운용;이유정;이해기;강성화
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.501-502
    • /
    • 2006
  • In this paper, new and aging sample of MCCB and ELCB are investigated the main performance test such as short circuit test, mechanical and electrical endurance test, dielectric test and surge current test. The surface conditions of new and aging sample are analyzed by SEM, TGA and DSC. The ELCB occurred badness mainly in short circuit test and surge current test. The badness cause of short circuit test was confirmed due to imperfect contact of contact part.

  • PDF

대형의료기기의 회로 단락시 전류흐름에 대한 시뮬레이션 연구 (A study on simulation to current flow by short circuit of medical machine)

  • 최도순
    • 한국정보전자통신기술학회논문지
    • /
    • 제5권4호
    • /
    • pp.211-215
    • /
    • 2012
  • 대형의료기기는 환자 진단과 치료 행위에 있어서 매우 중요한 기기이다. 이런 대형의료기기를 사용하여 환자를 진단 또는 치료할 때 의료기기의 회로 내에서 갑작스런 전류의 변화는 회로의 단락 등 매우 심각한 문제를 일으킨다. 특히 회로 내에서 전류변환기에 큰 부하가 걸리게 한다. 이것으로 인해 변환기는 포화에 이르게 되는데 이것은 철심코일 인턱터의 magnetic curve에 기인한다. 이와 같이 변환기가 saturate에 이르게 되면 1차 측과 2차 측의 변환 비율이 깨지게 되고 회로가 단락되는 문제가 발생하게 된다. 이 논문 에서는 대형의료기기에 사용되는 current 변환기의 입력 측에 갑작스런 큰 전류 변화가 발생 했을 때 일어나는 그에 따른 포화 상태와 그의 2차 측 전류의 변화를 simulation 해본다.

2.5 mm2 HIV에 일반화염 및 DC 단락 전류를 인가하여 생성된 기공의 정량적 분포 해석 (Quantitative Distribution of Created Voids by Applying General Flame and DC Short-circuit Current to 2.5 mm2 HIV)

  • 김승삼;최충석
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.38-42
    • /
    • 2013
  • This study performed the quantitative distribution analysis of created voids to an insulator when applying general flame and DC short-circuit current to 2.5 $mm^2$ HIV (600 V Grade Heat-Resistant Polyvinyl Chloride Insulated Wires). The diameter of cross-section of HIV normal product and the radius of conductor were measured to be 3.3 mm and 1.8 mm. The exterior of HIV exposed to general flame showed severe carbonization and its interior exhibited voids created by dechlorination reaction. This study observed the characteristics that, when the shortcircuit current applied for 2 seconds from a DC 12 V lead battery, the conductor and neighboring insulator were melted, causing the insulator adhering to the conductor. On average, 87 voids were created on 10 mm of the HIV. The average diameter of voids was 0.25 mm. In addition, it was found that, when the short-circuit current applied for 4 seconds, the interior of insulator in contact with conductor severely carbonized and showed exfoliation phenomenon. On average, 47 voids were created, with more voids at the bottom. The average diameter of voids was 0.20 mm. When the short-circuit current for 6 seconds, most parts of upper part of conductor was carbonized, 20 voids were created. The average diameter of voids was measured to be 0.24 mm. It could be seen that the created voids received little influence by the type of energy source and the number of created voids was reduced as the energy supply time increased.

전류 전처리의 경피 투과도에 미치는 효과 (Current Pretreatment of Skin and Its Effect on the Permeability)

  • 이정화;오승열
    • Journal of Pharmaceutical Investigation
    • /
    • 제35권2호
    • /
    • pp.81-87
    • /
    • 2005
  • We have prepared karaya gum patches containing ketoprofen and investigated the effect of short-time current pretreatment of skin on the permeability. Hairless mouse skin was treated with current before the patch was mounted on the skin. The effect of current density and current duration on the flux of ketoprofen was studied. The possibility of additive effect with penetration enhancer (PGML) was also investigated. Iontophoretic pretreatment of skin increased the passive flux up to 3 folds at 0.4 $mA/cm^2$ current density, when the matrix contained no PGML. As the duration of current-pretreatment and current density increased, flux increased. PGML increased the average passive flux markedly, about 6 to 12 folds, depending on the concentration in the patch. Current pretreatment further increased the flux from this PGML containing patch, exhibiting additive effect. These results indicate that short-duration current pretreatment of skin can be an useful method for the enhancement of ketoprofen permeability through skin.

KERI 합성투입시험회로의 해석적 고찰 (Analytical Examination of KERI Synthetic Short-circuit Current Making Test Circuit)

  • 이용한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.455-457
    • /
    • 2003
  • In the present IEC 60427(2000), reduced applied voltage can be used for synthetic short-circuit making current tests if the maximum pre-arcing time of the test circuit breaker is less than $1/{\omega}$. But in the near future IEC, only the making tests with full test voltage shall be allowed. To meet this trend, KERI is preparing synthetic making test facilities using step-up transformer, ITMC and plasma making switch. This paper presents analytical characteristics of KERI's synthetic short-circuit making test circuits. The results of this paper can be useful for effective and adequate tests.

  • PDF

Three-phase Making Test Method for Common Type Circuit Breaker

  • Ryu, Jung-Hyeon;Choi, Ike-Sun;Kim, Kern-Joong
    • Journal of Electrical Engineering and Technology
    • /
    • 제7권5호
    • /
    • pp.778-783
    • /
    • 2012
  • The synthetic short-circuit making test to adequately stress the circuit breaker has been specified as the mandatory test duty in the IEC 62271-100. The purpose of this test is to give the maximum pre-arcing energy during making operation. And this requires the making operation with symmetrical short-circuit current that is established when the breakdown between contact gap occurs near the crest of the applied voltage. Also, if the interrupting chamber of circuit breakers is designed as the type of common enclosure or the operation is made by the gang operated mechanism that three-phase contacts are operated by one common mechanism, three-phase synthetic making test is basically required. Therefore, several testing laboratories have developed and proposed their own test circuits to properly evaluate the breaker performance. With these technical backgrounds, we have developed the new alternative three-phase making circuit.

부스바(Busbar)형 전기접점의 단락통전성능 해석기법 개발 (Development of the Analysis Technology for Short Circuit Current Capability of Busbar-Type Electrical Contacts)

  • 오연호;송기동;김진기
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권1호
    • /
    • pp.27-32
    • /
    • 2005
  • This study presents an analysis technique that can consider all variables which are needed in the design of short circuit current capability of electrical contacts. Required variables in the design are material of contact, contacting area, applied force, asperity of surface, current and so on. Short circuit current capability test was carried out for the interrelation of design variables and the verification of analysis technique. Temperature rise equation of the contacts was obtained from the test results, and also, a standard that is criterion of the occurrence availability of melting or spot of contact surface from test results was established.