• 제목/요약/키워드: shim coil

검색결과 63건 처리시간 0.027초

비자성 연선도체의 단면적을 검출하기 위한 솔레노이드 와전류 센서의 임피던스 해석 및 실험적 연구 (Impedance Analysis and Experimental Study of a Solenoid Eddy Current Sensor to Detect the Cross-sectional Area of Non-ferromagnetic Stranded Conductors)

  • 김성덕;심재명
    • 센서학회지
    • /
    • 제6권2호
    • /
    • pp.87-94
    • /
    • 1997
  • 이 논문에서는 비자성 연선도체의 단면적을 검출하는 솔레노이드 센서의 임피던스 해석이 다루워졌다. 도전체의 전기 자기적 특성들을 검출하기 위하여, 관통형 코일로 비파괴검사 와전류 센서를 선택하였다. Maxwell 방정식을 풀어서 도체봉을 가진 센서의 규격화 임피던스 응답이 모델링되고 그 결과들이 연선에 확장되었다. 연선구조에 미치는 기하학적 성질이 검토되고 수치 해석과 실험결과 또한 주어진다.

  • PDF

Performance inspection of smart superconducting fault current controller in radial distribution substation through PSCAD/EMTDC simulation

  • MassoudiFarid, Mehrdad;Shim, Jae Woong;Lee, Jiho;Ko, Tae Kuk
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제15권4호
    • /
    • pp.21-25
    • /
    • 2013
  • In power grid, in order to level out the generation with demand, up-gradation of the system is occasionally required. This will lead to more fault current levels. However, upgrading all the protection instruments of the system is both costly and extravagant. This issue could be dominated by using Smart Fault Current Controller (SFCC). While the impact of Fault current Limiters (FCL) in various locations has been studied in different situations for years, the performance of SFCC has not been investigated extensively. In this research, SFCC which has adopted the characteristics of a full bridge thyristor rectifier with a superconducting coil is applied to three main locations such as load feeder, Bus-tie position and main feeder location and its behavior is investigated through simulation in presence and absence of small Distributed Generation unit (DG). The results show a huge difference in limiting the fault current when using SFCC.

PCB와 Chassis 연결에 따른 공통모드 전류와 EMI 감소효과 (EMI and Common-mode Current Reduction Effect by PCB-Chassis connection)

  • 남기훈;심민규;고은광;나완수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1442-1443
    • /
    • 2008
  • 본 논문에서는 인쇄회로기판과 도전체 샤시(Chassis)가 연결되었을 때의 복사성 방사(Radiated Emission)의 감소에 대해서 연구하였다. Current Driven 메커니즘 등가회로를 사용하여 전자파 방사의 주요한 원인중 하나인 Common-mode Current를 인쇄회로기판과 Chassis가 연결된 구조에 적용하였다. Chassis의 유무에 따라 복사성 방사의 감소를 확인하고자 2-layer 인쇄회로기판과 SECC(Steel Electro galvanized Cold-rolled Coil) 재질의 Chassis를 나사(Screw)를 통하여 전기적으로 연결하였을 때를 시뮬레이션 하였고, 제작된 구조물을 3m 무반향실에서 복사성 방사를 측정한 후 시뮬레이션과 결과를 비교하였다. 결과로 30MHz$\sim$45MHz에서 최대 10dB 감소의 효과가 있음을 확인하였다.

  • PDF

PLL을 이용한 무선 전력전송 장치의 공진 주파수의 계측 및 주파수 제어 (Measurement and Control of the Resonance Frequency for the Transcutaneous Energy Transmission System (TET) Using the Phase Locked Loop Circuit (PLL))

  • 최성욱;심은보
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.1613-1616
    • /
    • 2008
  • A Transcutaneous Energy Transmission System (TET) has been developed for the wireless energy transmission with two magnetically coupled coils. A resonance circuit is used to raise the induced voltage and current of the secondary coil. Its resonance frequency depends on the internal resistance of circuit and the transferred energy. Because the transferred energy usually changes in wide range, the output voltage is unstable and the energy transferring efficiency decrease. A push-pull class E amplifier is usedto generate high frequency AC voltage. To maintain proper resonance frequency, the voltage output of the amplifier was continuously monitored and adjusted to the optimized resonance frequency. Because of its high frequency (370 kHz), a phase lockedloop circuit and a comparator are used to monitor the output waveform. The results of experimentaldata show that the PLL circuit can increase the transmission efficiency and stabilize the output voltage of TET.

  • PDF

3.0T 자기공명영상을 이용한 해상력 특성에 대한 연구 (Study on the Resolution Characteristics by Using Magnetic Resonance Imaging 3.0T)

  • 민정환;정회원;한지현;이시내;한송이;김기원;김현수;손진현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권4호
    • /
    • pp.251-257
    • /
    • 2020
  • This study was purpose to quantitative evaluation of edge method of modulation transfer function(MTF) and physical image characteristics of by obtain the optimal edge image by using magnetic resonance imaging(MRI). The MRI equipment was used (MAGNETOM Vida 3.0T MRI, Siemense healthcare system, Germany) and the head/neck matrix shim MR coil were 20 channels(elements) receive coil. The MTF results of showed the best value of 0.294 based on the T2 Nyquist frequency of 1.0 mm-1. The MTF results of showed that the T1 image is 0.160, the T1 CE image is 0.250, T1 Conca2 image is 0.043, and the T1 CE (Concatenation) Conca2 image is 0.190. The T2 image highest quantitatively value for MTF. The physical image characteristics of this study were to that can be used efficiently of the MRI and to present the quantitative evaluation method and physical image characteristics of 3.0T MRI.

자기공명영상에서 ACR 팬텀을 이용한 잡음전력스펙트럼 평가 (Evaluation of the Noise Power Spectrum by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권1호
    • /
    • pp.21-28
    • /
    • 2024
  • This study was purpose to quantitative evaluation of comparison of the image intensity uniformity and noise power spectrum (NPS) by using American college of radiology (ACR) phantom for magnetic resonance imaging (MRI). The MRI was used achiva 3.0T MRI and discovery MR 750, 3.0T, the head and neck matrix shim SENSE head coil were 32 channels receive MR coil. The MRI was used parameters of image sequence for ACR standard and general hospital. NPS value of the ACR standard T2 vertical image in GE equipment was 7.65E-06 when the frequency was 1.0 mm-1. And the NPS value of the ACR hospital T1 region of interest (ROI) 9 over all vertical image in Philips equipment was 9E-08 when the frequency was 1.0 mm-1 and the NPS value of the hospital T2 ROI 9 over all vertical image in Philips equipment was 1.06E-07 when the frequency was 1.0 mm-1. NPS was used efficiently by using a general hospital vertical sequence more than the standard vertical sequence method by using the ACR phantom. Furthermore NPS was the quantitative quality assurance (QA) assessment method for noise and image intensity uniformity characteristics was applied mutatis mutandis, and the results values of the physical imaging NPS of the 3.0T MRI and ACR phantom were presented.

Design and Contact Force Control of a Flip Chip Mounting Head system

  • Kim, Kyoung-Jun;Shim, Jae-Hong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1060-1065
    • /
    • 2003
  • This paper contributes to development of a new chip mounting head system for flip chip. Recently, the LDM(Linear DC Motor) has been widely used, because it has particular merits than the rotary type motors. In this paper, we proposed a macro/micro positioning system for force control of a chip mounting system. In the proposed macro/micro system, the macro actuator provide the system with a gross motion while the micro device yields fine tuned motion to reduce the harmful impact force that occurs between very small sized electronic parts and PCB surface. In order to prove the effectiveness of the proposed macro/micro chip mounting system, we compared the proposed chip mounting head with the conventional chip mounting head equipped with a macro actuator only. A series of experiments were executed under the mounting conditions of various access velocities and PCB stiffness. As a result of this study, a satisfactory voice coil actuator as the micro actuator has been developed, and its performance meet well the specifications desired for the design of the chip mounting head system and show good correspondence between theoretical analysis and experimental results.

  • PDF

Study the Properties of Silicon Nitride Films prepared by High Density Plasma Chemical Vapor Deposition

  • Gangopadhyay, Utpal;Kim, Do-Young;Parm, Igor Oskarovich.;Chakrabarty, Kaustuv;Kim, Chi-Hyung;Shim, Myung-Suk;Yi, Jun-Sin
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.1127-1130
    • /
    • 2003
  • The characteristics of silicon nitride films deposited in a planar coil reactor using a simple high-density inductively coupled plasma chemical vapor deposition technique have been investigated. The process gases used during silicon nitride deposition cycle were pure nitrogen and a mixture of silane and helium. It has been pointed out that the strong H-atom released from the growing SiN film and Si-N bond healing are responsible for the improved electrical and passivation properties of SiN.

  • PDF

Endovascular Treatment of Symptomatic High-Flow Vertebral Arteriovenous Fistula as a Complication after C1 Screw Insertion

  • Jang, Hyun Jun;Oh, Se-Yang;Shim, Yu Shik;Yoon, Seung Hwan
    • Journal of Korean Neurosurgical Society
    • /
    • 제56권4호
    • /
    • pp.348-352
    • /
    • 2014
  • High-flow vertebral arteriovenous fistulas (VAVF) are rare complications of cervical spine surgery and characterized by iatrogenic direct-communication of the extracranial vertebral artery (VA) to the surrounding venous plexuses. The authors describe two patients with VAVF presenting with ischemic presentation after C1 pedicle screw insertion for a treatment of C2 fracture and nontraumatic atlatoaxial subluxation. The first patient presented with drowsy consciousness with blurred vision. The diffusion MRI showed an acute infarction on bilateral cerebellum and occipital lobes. The second patient presented with pulsatile tinnitus, dysarthria and a subjective weakness and numbness of extremities. In both cases, digital subtraction angiography demonstrated high-flow direct VAVFs adjacent to C1 screws. The VAVF of the second case occurred near the left posterior inferior cerebellar artery originated from the persistent first intersegmental artery of the left VA. Both cases were successfully treated by complete occlusion of the fistulous portion and the involved segment of the left VA using endovascular coil embolization. The authors reviewed the VAVFs after the upper-cervical spine surgery including C1 screw insertion and the feasibility with the attention notes of its endovascular treatment.

고투자율 등방성 자기 물질을 이용한 공진형 마그네토미터 개발 (Development of Resonant-Type Magnetometer Using High Permeability Isotropic Magnetic Material)

  • 임정빈;심영호;안영섭
    • 해양환경안전학회지
    • /
    • 제11권1호
    • /
    • pp.29-37
    • /
    • 2005
  • 본 논문에서는 고투자율 등방성 자기물질을 이용한 공진형 마그네토미터(Resonant-type Magnetometer, RM)의 설계와 개발에 관하여 기술하였다. 먼저, 자기 물질에 감은 코일의 인덕턴스 L과 등방성 고투자율 자기 물질에서 나타나는 투자율 u(H) 사이의 기본이론을 정립하였다. 다음으로, L 의 변화를 간단한 슈미트 트리거 회로를 이용하여 주파수로 획득할 수 있는 RM회로를 구현하였다. RM의 측정능력을 평가하기 위한 선회실험을 통하여 RM의 지구자장 성분 측정 가능성을 확인하였다.

  • PDF