• Title/Summary/Keyword: sheath current

Search Result 144, Processing Time 0.035 seconds

Characterisitics of the over current of Bi-2223 HTS tape (Bi-2223 고온초전도선의 과전류 통전특성)

  • Kim, Jae-Ho;Sim, Ki-Deok;Cho, Jeon-Wook;Kim, Hae-Jun;Kwag, Dong-Soon;Seong, Ki-Chul;Kim, Hae-Jong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.284-285
    • /
    • 2005
  • Bi-2223 High-Temperature Superconducting(HTS) tape is one of the most widely used HTS tape for power application. Characteristics of the over current of HTS tape with different sheath are described. This paper presents the basic properties such as temperature and resistivity rise of the Bi-2223 HTS tape which is exposed to the over current. It is expected that results from this study can be utilized as basic data in designing superconducting power devices.

  • PDF

A Study on the Generation of the Earth Potential and Communication Line Noise. (대지전위와 통신회선 잡음 발생에 대한 고찰)

  • Yeo, Sang-Kun;Park, Chan-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.33-38
    • /
    • 2007
  • This paper presents a experimental evidence of the generation of the earth potential and communication line noise from the electric railway. There is a critical measurement err in case of measuring the electrical power induced noise voltage and degree of cable balance in the field of earth potential generated. As a results, it has been found that the conventional cable has more noise immunity than shielded cable near the railway where the earth current flows through the sheath layer.

  • PDF

A Study on the Proper Installation Location of a Sheath Circulating Current Reduction Equipment (시스순환전류 저감장치의 적정 설치위치 검토)

  • Hong, D.S.;Jang, T.I.;Kang, J.W.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.638-640
    • /
    • 2005
  • 본 논문에서는 지중 실계통에 저감장치의 설치 위치를 다양하게 변경시켰을 경우 시스 순환전류의 변화를 분석하였으며, 그 결과 보통접속함에 저감장치를 설치하였을 경우가 절연접속함에 설치했을 경우에 비해 적은 저감효과를 보임으로써 저감장치 적용지점 선정에 있어 보통접속함의 저감장치 취부를 가능한 자제할 것으로 권하고 있는 국내 기준(안)의 타당성을 확인하였다.

  • PDF

Thermal conductivity and properties of sheath alloy for High-$T_c$ superconductor tape (고온초전도 선재용 피복합금의 열전도도 측정 및 특성평가)

  • 박형상;지봉기;김중석;임준형;오승진;오승진;주진호;나완수;유재무
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.8
    • /
    • pp.711-717
    • /
    • 2000
  • Effect of alloying element additions to Ag on thermal conductivity electrical conductivity and mechanical properties of sheath materials for BSCCO tapes has been characterized. The thermal conductivity at low temperature range(10~300K) of Ag alloys were evaluated by both direct and indirect measurement techniques and compared with each other. It was observed that thermal conductivity decreased with increasing the content of alloying elements such as Au, Pd and Mg. Thermal conductivity of pure Ag at 30 K was measured to be 994.0 W/m.K on the other hand the corresponding values of A $g_{0.9995}$/M $g_{0.0005}$, A $g_{0.974}$/A $u_{0.025}$/M $g_{0.001}$, A $g_{0.973}$/Au.0.025//M $g_{0.002}$, and A $g_{0.92}$/P $d_{0.06}$/M $g_{0.02}$ were 342.6, 62.1, 59.2, 28.9 W/m.K respectively indicating 3 to 30 times lower than that of pure Ag. In addition alloying element additions to Ag improved mechanical strength while reduced elongation probably due to the strengthening mechanisms by the presence of additive atoms.s.

  • PDF

Relationship between cotyledon Number and Vascular System in Carrot Seedling (당근 유식물체에서 자엽수와 유관속계의 관련성)

  • 김경식
    • Korean Journal of Plant Resources
    • /
    • v.11 no.1
    • /
    • pp.30-39
    • /
    • 1998
  • Carrot seedling emgryos showing variations in cotyledon number were selected and anatomical comparisons of the embryo vascular systems were performed between the variants and normal two cotyledonary (5) embryos from 800 seedings germinated . Externally, all of the four and six cotyledonary embryos had two cotyledonary petioles. Each of the cotyledonary petioles divided into two or three on the upper part fo the petiole which result in four and six cotyledons, respectively. However, the embryos had three different cotyledonary petioles in the three cotyledonary embryos. On the basis of the pattern of vascular system, the four and six cotyledonary embryos had the same basic vascular system as fnormal two cotyledonary embryos, Therefore the cotyledon number abnormality could result from the branching split of the abnormally thickened upper part of the cotyledonary petiole. However, the three cotyledonaryembryos had a different vascular system from the normla two cotyledonary embryos. They could be regarded as different varieties form the two cotyledon embryos. All embryos observed had short cylindrical plumule sheath which formed by the fusion of the cotyledon bases. The presence of plumule sheath strontgly implied that the initiation of the cotyledons was not from the two localized primordia but from the circular proimordiu formed at the blobular stageof embryo, and it is not consistent with current views of cotyledon initiation. On the formation of the primary vascular system of carrot seedlings, it is suggested that the primary vascular system of the plumule was formed independently from that of the root-hypocotyle-cotyledon system.

  • PDF

A Study on the Propogation Velocity of Biological Action Potential (생체의 자극 전도속도에 관한 연구)

  • Che, Gyu-Shik;Kwon, Yong-Chan
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.1002-1009
    • /
    • 2010
  • I made the axon to the electrical transmission model and then constructed electrical equivalent model using Kirhhoff's current law and voltage law in this paper. I calculated various axon parameters in order to analyze the electrical potential hehavior versus minute distance chang of axon. The transmission velocity of unmyelinated nerve is proportional to square root of axon diameter, while that of myelinated nerve is directly proportional to its diameter. Because the transmission of myelin sheath is independent of voltage unlike unmyelinated sheath, the Hodgkin-Huxley model across the membrane is not so precise.

The Thermal Characteristics of Partially Disconnected Wire Happened in Plug (플러그 내부에서 발생된 소선 단선에 의한 발열특성)

  • Jee, Seung-Wook;Kim, Shi-Kuk;Lee, Chun-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.4
    • /
    • pp.104-110
    • /
    • 2011
  • There are over 30[%] of electric fires in Korea happened at wire or wiring devices. For its prevention many safety devices are set up electric equipments. These safety devices are not working in a rated current's condition of electric equipment. But when wire is partially disconnected, electric fire is able to be happened even though current is smaller than a rated current value. This paper studied thermal characteristics and fire ability when wire in plug is partially disconnected. The experiment is progressed a method that inner wire of plug is partially disconnected and after that current that is less than a rated current is flowed. As the result, heating occurred in near of partially disconnected wire makes that outer sheath is melted, plug cover is carbonized, and even sometimes wire is fused. And results of analysis of thermal image of partially disconnected wire happened in plug, it shows a difference to heating distribution and temperature appeared surface of plug depend on a progress of a partially disconnected wire.

A study on fabrication of Bi-2223 tape for current lead (전류 도입선용 고온 초전도 선재 제작에 관한 연구)

  • Yim, Seong-Woo;Park, Kyung-Kuk;Han, Byung-Sung;Ha, Hong-Su;Cheong, Dae-Young;Oh, Sang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.835-837
    • /
    • 1998
  • Current lead plays the part of connector between ambient temperature and liquid helium superconducting magnet. Having zero resistance characteristic, it is expected that HTS has very low thermal conductivity and generate no joule heat when fabricated to current lead. In particular, among the HTS meterials, HTS tape has high Jc and Ag-sheath of tape plays the part of stabilizer, but it has too poor mechanical strength to be applied and when fabricated as long length tape, it has tendency to decline Jc seriously. In this study, we fabricated Bi-2223 multifilamentary tapes and then made current lead with stacking type using them. Through this work, we conclude that the defect of HTS long length tape is decreased by addition the number of stacking tape and that current lead is able to operate more stably by minimizing the gap of tapes.

  • PDF

Analysis of Sheath Temperatures and Load Currents Dependent on Conductor Temperatures in Live 6kV CV Cables Operating at a Power Station (발전소에서 운전 중인 활선 6 kV CV 단심 cable의 도체온도에 따른 피복 표면온도 및 부하전류 특성 분석)

  • Um, Kee-Hong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.3
    • /
    • pp.189-195
    • /
    • 2017
  • The only method used in the power stations in order to deliver generated electric power is 6 kV XLPE (or CV) single core cables. Among many kinds of accidents happening in the power stations, the outbreak of fire due to the deterioration of live cables causes enormous socioeconomic losses. From the installation of the cables, the management and diagnose should be thoroughly made. Even though it differs depending on the installations and usage conditions, the cross-sectional area of cables is in shortage. The excessive allowable temperature caused from the current causes the deterioration of cables. In order to prevent an unexpected breakdown of live cables, we have invented a device to monitor and diagnose the status of cables. We have installed our device in the Korea Western Power Co., Ltd.. In this paper, we present our research results in situ that we have obtained by measuring the temperature of sheath, changing with the surrounding circumstances, especially ambient temperatures. We also show our study results of characteristics for temperature of sheath surface and load current at the ambient temperatures of $40^{\circ}C-10^{\circ}C$.

Evaluation of mechanical properties of Bi-2223/Ag HTS tapes (Bi-2223/Ag 고온초전도 선재의 기계적 특성 평가)

  • 하홍수;이동훈;양주생;최정규;윤진국;하동우;오상수;권영길
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.351-354
    • /
    • 2002
  • In most of electrical applications using Bi-2223/Ag HTS tapes, bending and tension stresses are essentially applied to the tape. Therefore, the critical current of the Bi-2223/Ag tape is degraded by increasing the deformation stress, though brittle superconducting filaments are embedded in the reinforced Ag alloy sheath. It is needed to understand bending and tension properties of HTS tapes at room temperature and cryogen to make superconducting magnet, cable and etc. using Bi-2223/Ag HTS tapes. Actually, bending and tension stress applied to the tapes simultaneously, when winding the tapes on former for applications. In this study, the effect of mechanical deformations, bending and tension, on the critical current of Bi-2223/Ag tape was investigated.

  • PDF