펄스형 방전플라스마 장치에서 current sheath의 속력 (Speed of Current Sheath in Pulsed Discharge Plasma Device)

  • 최운상;최호성
    • 한국안광학회지
    • /
    • 제12권1호
    • /
    • pp.69-74
    • /
    • 2007
  • 펄스형 방전플라스마장치에서 축방향 플라스마 curren sheath의 속력을 측정하였고, snowplow 모델과 비교하였다. Current sheath의 속력은 $10^6cm/s$로 측정되었다. 측정된 속력 중에서 가벼운 기체인 수소와 헬륨은 모델의 이론과 비슷한 결과가 나왔으나 무거운 기체인 아르곤은 이론과 조금 벗어났다. 그 이유는 current sheath의 불안정성 때문으로 추정된다.

  • PDF

지중송전계통에서 저감장치를 이용한 시스 순환전류 저감방안에 관한 연구 (A Study on the Reduction Methods of Sheath Circulating Current using the Reduction Equipment in Underground Transmission Systems)

  • 강지원;양해원
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권9호
    • /
    • pp.474-481
    • /
    • 2002
  • Sheath circulating current is increased in the change of sheath mutual impedance which is caused by unbalanced cable system, and different section length between joint boxes. If excessive current flows in sheath, sheath loss which is reduced the transmission capacity is produced. Recently, excessive sheath circulating current was partially measured in underground cable systems of KEPCO. Accordingly, actual schemes to reduce excessive sheath circulating current are urgently required for installed cable system as well as newly-installing cable systems. This paper describes the relation analysis of sheath circulating current and burying types. And also, various schemes to reduce excessive circulating current using EMTP/ATPDraw and applicable schemes are proposed through a detailed analysis regarding cable systems by considering various electrical and environmental factors. It is evaluated that the proposed reduction schemes can be effectively applied to reduce the excessive sheath circulating current with the minimized electrical problems. And reduction effect is Proved with sheath circulating current reduction equipment.

해석 및 측정을 통한 시스순환전류 특성 및 상승원인 검토 (A Study on the Characteristic and Rising Cause of Sheath Circulating Current by Analysis and Measurement)

  • 강지원;양해원
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권10호
    • /
    • pp.525-533
    • /
    • 2002
  • It is common to install multiple lines in the same route. Recently, excessive sheath circulating current was partially measured in underground cable systems of KEPCO. Especially, the installation type, unbalance section length between joint boxes and zero sequence current by distribution cable have an effect on the rising of sheath circulating current in the underground transmission system. If excessive current flows in sheath, sheath loss which is reduced the transmission capacity is produced. This paper describes the relation analysis of sheath circulating current and burying types. And also, a detailed analysis on rising cause and characteristic of sheath circulating current by considering various unbalanced conditions presents using analysis and measurement regarding cable systems which have the problem of excessive sheath circulation current.

Sheath Circulating Current Analysis of a Crossbonded Power Cable Systems

  • Jung, Chae-Kyun;Lee, Jong-Beom;Kang, Ji-Won
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권3호
    • /
    • pp.320-328
    • /
    • 2007
  • The sheath in underground power cables serves as a layer to prevent moisture ingress into the insulation layer and provide a path for earth return current. Nowadays, owing to the maturity of manufacturing technologies, there are normally no problems for the quality of the sheath itself. However, after the cable is laid in the cable tunnel and is operating as part of the transmission network, due to network construction and some unexpected factors, some problems may be caused to the sheath. One of them is the high sheath circulating current. In a power cable system, the uniform configuration of the cables between sections is sometimes difficult to achieve because of the geometrical limitation. This will cause the increase of sheath circulating current, which results in the increase of sheath loss and the decrease of permissible current. This paper will study the various characteristics and effects of sheath circulating current, and then will prove why the sheath current rises on the underground power cable system. A newly designed device known as the Power Cable Current Analyser, as well as ATP simulation and calculation equation are used for this analysis.

펄스형 방전플라스마 장치에서 반경방향 Current Sheath의 속력 (Radial Speed of Current Sheath in Pulsed Discharge Plasma Device)

  • 최운상;장준규
    • 한국안광학회지
    • /
    • 제13권3호
    • /
    • pp.57-60
    • /
    • 2008
  • 목적: 펄스형 방전플라스마 포커스 장치에서 반경방향 플라스마 current sheath 의 속력을 측정하였다. 방법: 측정에는 시간분해 분광분석법과 로고프스키 코일이 사용되었다. 결과: 15 kV의 방전전압과 수십 torr의 He과 Ar의 기체기압에서 $10^5$ cm/s의 속력이 측정되었으며, 기체기압이 증가할수록 current sheath의 속력은 감소되었다. 결론: 최적조건인 수 torr의 기압에서는 $10^7$ cm/s의 속력이 나올 것으로 예상된다.

  • PDF

지중송전계통의 시스순환전류 저감에 관한 연구 (A Study on the Reduction of Sheath Circulating Current in Underground Transmission Systems)

  • 정채균;홍동석;이종범;강지원;유철환;강원탁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.29-33
    • /
    • 2001
  • Sheath circulating current results from the change of sheath mutual impedance which is caused by unbalanced cable system, and different section length between joint boxes. If circulating over current flows in sheath, it produces much sheath loss which reduces the transmission capacity. And also such large sheath current influences severely on the operator. Recently, large sheath circulating current was partially measured in underground cable system of KEPCO. Accordingly, actual schemes to reduce sheath circulating over current is urgently required for installed cable system as well as newly-constructing cable system. This paper describes the analysis of sheath circulating current and various schemes to reduce the large circulating current in case of operating cable system using EMTP/ATPDraw. And also, possible schemes are proposed through a detailed analysis regarding cable systems by considering various electrical and environmental factors. It is evaluated that the proposed reduction schemes can be effectively applied to reduce the large sheath circulating over current with the minimized electrical problems.

  • PDF

이온유체방정식을 이용한 Plasma Sheath 시변 해석 (Analysis of Time-Dependent Behavior of Plasma Sheath using Ion Fluid Model)

  • 이호준;이해준
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2173-2178
    • /
    • 2007
  • Dynamics of plasma sheath was analyzed using simple ion fluid model with poison equation. Incident ion current, energy, potential distribution and space charge density profile were calculated as a function of time. The effects of initial floating sheath on the evolution of biased sheath were compared with ideal matrix sheath. The effects of finite rising time of pulse bias voltage on the ion current and energy was studied. The influence of surface charging on the evolution of sheath was also investigated

EMTP 기반 지중송전케이블 시뮬레이터 개발 및 적용 (Development and Applicatin of EMTP Based Power Cable Simulator for Underground Transmission Cables)

  • 정채균;박흥석;강지원;이종범;한상옥
    • 전기학회논문지
    • /
    • 제59권8호
    • /
    • pp.1374-1381
    • /
    • 2010
  • This paper discusses the characteristics of sheath circulating current as well as the development and application of new software for underground power cable systems. Generally, in steady state, high sheath circulating current causes the increase of sheath temperature and thermal resistance which leads to the steeply reduction of the power capacity. Therefore, the exact calculation of sheath circulating current is required for analysis about the influence of high sheath current on permissible current. In this paper, Power Cable Simulator is developed for calculation of the sheath current. It can analyse the sheath current by real time. It is also easier to use than conventional software, such as EMTP and CabSim, because all the data for calculating the cable parameters are stored in a database(DB) within Power Cable Simulator. In addition, the accuracy of Power Cable Simulator is also proved through the comparison among the current calculated by Power Cable Simulator, EMTP and Cabsim with measured current.

과도상태에서의 시스순환전류 저감장치 보호방안에 관한 연구 (A Study on the Protection Methods of Sheath Circulating Current Reduction Device in Transient State)

  • 강지원;정채균;이종범;이동일;정길조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.53-58
    • /
    • 2002
  • Sheath circulating current is increased as the change of sheath mutual impedance which is caused by imbalance of cable system, and different section length between joint box. If excessive current flows in sheath. sheath loss will be increased and then transmission capacity of underground transmission system is reduced. Accordingly, This paper proposed sheath current reduction device using resistor and reactor and proved the reduction effect of that device using EMTP/ATP. And also in this paper, when transients are occurred at the underground system with reduction device by ground fault and lightning surge. we analyzes transient effect of system variously. From this result. authors establish the protection methods of sheath circulating current reduction device.

  • PDF

다회선 지중송전 케이블에서의 EMTP를 이용한 시스 순환전류 분석 (Analysis of Sheath Circulating Current on Multi-underground Transmission Cables using EMTP)

  • 하체웅;김정년;이수길;김동욱;이종범;강지원
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권10호
    • /
    • pp.510-517
    • /
    • 2002
  • The use of underground transmission cables has continuously increased in densely inhabited urban and suburban area. Due to a increasing demand of underground cables, two or more circuits are installed in parallel for several kilometers. It, however, has not been realized that the sheath circulating current is generated in the system where a large number of cables are laid in the same route. In this paper, sheath circulating current is analyzed by the EMTP and compared with the measured values. Unbalance arrangement of cables or cross-bonding length causes a significant effect on the magnitude of the sheath current. Sheath circulating current could be greatly reduced by the symmetrical configuration of cables and installation of the impedance reduction system. Especially, with the impedance system of 1Ω installed, the sheath circulating current is reduced by 85.7%.