• Title/Summary/Keyword: shear strengths

Search Result 693, Processing Time 0.026 seconds

A study on the flexural toughness evaluation method of steel fiber reinforced shotcrete (강섬유 보강 숏크리트의 휨인성 평가 방법 연구)

  • 김재동;김덕영
    • Tunnel and Underground Space
    • /
    • v.10 no.2
    • /
    • pp.196-210
    • /
    • 2000
  • This study was aimed to verify the validity of the flexural toughness evaluation method of steel fiber reinforced shotcrete(SFRS) currently being adopted by Korea Highway Corporation(KHC). Total 33 beam specimens using six different kinds of steel fiber products were prepared at tunnel construction sites and flexural toughness tests were executed at laboratory. Equivalent flexural strengths and toughness quotients were evaluated from the tests following the KHC guide iud these were compared with the quality grades determined under the guides proposed by ASTM, ITA and EFNARC. To discard the disadvantage that the toughness quotient could be influenced by flexural strength when following the KHC guide, a modification substituting the designed flexural strength for the flexural strength in the toughness quotient calculation formula was proposed to rate the quality of SFRS more adequately.

  • PDF

Member Utilization Concept Design for Hollow Circular Section Multi-column Tower Subjected to 10MW Level Wind Turbines (10MW급 풍력발전용 원형강관 멀티기둥타워의 부재유용도 개념설계)

  • Kim, Kyungsik;Kim, Mi Jin
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.3
    • /
    • pp.205-215
    • /
    • 2017
  • This study presents an example of conceptual design for hollow circular section multi-column tower system subjected to 10MW level wind load by introducing a method based on member utilization that examine both structural stability and economical efficiency. The basic assumptions for the proto type of a multi-column tower that can replace a single-cylinder tower were suggested and structural models were constructed following the assumptions and analyzed for identifying member forces. Based on the calculated member strengths and acting loads, the member utilization of the proposed multi-column tower structures were calculated for axial force, shear, bending and torsion and evaluaed for suitability as a wind tower. Design parameters such as steel tube dimensions, slenderness ratio, and number of floors for braces was proposed in the acceptable range of member utilization for conceptual design of multi-column wind towers.

Effects of Hardeners and Catalysts on the Reliability of Copper to Copper Adhesive Joint (Cu-Cu 접착부의 고온고습 내구성에 미치는 경화제 및 촉매제의 영향)

  • Min, Kyung-Eun;Kim, Hae-Yeon;Bang, Jung-Hwan;Kim, Jong-Hoon;Kim, Jun-Ki
    • Korean Journal of Materials Research
    • /
    • v.21 no.5
    • /
    • pp.283-287
    • /
    • 2011
  • As the performance of microelectronic devices is improved, the use of copper as a heat dissipation member is increasing due to its good thermal conductivity. The high thermal conductivity of copper, however, leads to difficulties in the joining process. Satisfactory bonding with copper is known to be difficult, especially if high shear and peel strengths are desired. The primary reason is that a copper oxide layer develops rapidly and is weakly attached to the base metal under typical conditions. Thus, when a clean copper substrate is bonded, the initial strength of the joint is high, but upon environmental exposure, an oxide layer may develop, which will reduce the durability of the joint. In this study, an epoxy adhesive formulation was investigated to improve the strength and reliability of a copper to copper joint. Epoxy hardeners such as anhydride, dihydrazide, and dicyandiamide and catalysts such as triphenylphosphine and imidazole were added to an epoxy resin mixture of DGEBA and DGEBF. Differential scanning calorimetry (DSC) analyses revealed that the curing temperatures were dependent on the type of hardener rather than on the catalyst, and higher heat of curing resulted in a higher Tg. The reliability of the copper joint against a high temperature and high humidity environment was found to be the lowest in the case of dihydrazide addition. This is attributed to its high water permeability, which led to the formation of a weak boundary layer of copper oxide. It was also found that dicyandiamide provided the highest initial joint strength and reliability while anhydride yielded intermediate performance between dicyandiamide and dihydrazide.

Physical properties of granitic weathered soil on natural terrain around Seoul city (서울주변에 분포한 화강암류 풍화토층의 물리적 성질)

  • Kim, Kyeong-Su
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1122-1129
    • /
    • 2010
  • Various soil tests were performed in the laboratory after soil samples were obtained from natural terrains distributed on the granitic rocks where are located in Mt. Bukhan, Mt. Surak and Mt. Gwanak around Seoul. Through the comparison of soil properties in each mountain, the difference of soil properties in a similar geological condition was investigated. According to the result of soil test, the soils were generally classified into calyey and silty sands with a well grade. Soil densities are ranged from $2.62kg/cm^3$ to $2.67kg/cm^3$, and water contents of soils are ranged from 3.77% to 31.12%. These values are not sorted locally. The wet unit weights of soils are ranged from $1.092kg/cm^3$ to $1.814kg/cm^3$. It has a big difference between the average values because that of Mt. Bukhan is $1.604kg/cm^3$ and those of Mt. Surak and Mt. Gwanak are $1.500kg/cm^3$ and $1.331kg/cm^3$, respectively. The internal friction angles are ranged from $31^{\circ}$ to $39^{\circ}$ and the cohesions are ranged from 1.57kPa to 8.63kPa. The shear strengths are too high and similar in all regions. The coefficients of permeability are ranged from $3.07{\times}10^{-3}cm/sec$ to $4.61{\times}10^{-2}cm/sec$. So, these soils are evaluated as a middle to high permeable ground. On average, the value of Mt. Bukhan is $1.47{\times}10^{-2}cm/sec$ and the values of Mt. Surak and Mt. Kwanak are $1.29{\times}10^{-2}cm/sec$ and $1.66{\times}10^{-2}cm/sec$, respectively.

  • PDF

Effect of Soil Reinforcement on Shear Strength by Pennisetum alopecuroides and Miscanthus sinensis Roots on Loamy Sand at River Banks (하천제방 양질사토에 대한 수크령과 억새 뿌리의 토양전단강도 보강효과)

  • Dang, Ji-Hee;Cho, Yong-Hyeon;Lee, Chun-Seok
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.2
    • /
    • pp.79-91
    • /
    • 2017
  • This study was conducted to find out the physical properties and soil shearing strength reinforcement effect of herbaceous plants for the slope revegetation works. Two native plants(Pennisetum alopecuroides and Miscanthus sinensis) were used for this experiment, because they have excellent seed germination rates without preconditioning, and grow naturally around rivers. To identify the physical properties, the partial dry weight of plants were investigated. To identify the soil shearing strength reinforcement effect, the respective soil shearing strengths of the control soils, Pennisetum alopecuroides, Miscanthus sinensis samples were measured. Also, we did a correlation analysis to examine the relation of shearing strength to plant features. The results are summarized as follows: 1. The average dry weight of Pennisetum alopecuroides samples consists of 52.36% above ground and 47.64% at root. And in dry weight, 78.24% of it's root distributes within 10 cm in soil depth. Meanwhile the average dry weight of Miscanthus sinensis samples consists of 52.91% above ground and 47.09% at root. And in dry weight, 82.95% of it's root distributes within 10 cm in soil depth. 2. The results of correlation analysis showed that for both Pennisetum alopecuroides and Miscanthus sinensis, it could not be said that there was any correlation between shearing strength and plant characteristics, and statistically they were not meaningful. 3. In the shearing strength test with control soils, Pennisetum alopecuroides, Miscanthus sinensis as subjects, the differences in shearing strength measurement results were modest, and the order was shown as control soils < Pennisetum alopecuroides < Miscanthus sinensis, so the soil shearing strength reinforcement effect by the Pennisetum alopecuroides and the Miscanthus sinensis on loamy sand at river banks surface was confirmed.

Development of DCOC Algorithm Considering the Variation of Effective Depth in the Optimum Design of PRC Continuous Beam (PRC연속보 최적설계에서 단면의 유효깊이 변화를 고려한 DCOC알고리즘 개발)

  • 조홍동;한상훈
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.15 no.2
    • /
    • pp.281-291
    • /
    • 2002
  • This paper describes the minimum cost design of prestressed reinforced concrete (PRC) hem with rectangular section. The cost of construction as objective function which includes the costs of concrete, prestressing steel, non prestressing steel, and formwork is minimized. The design constraints include limits on the minimum deflection, flexural and shear strengths, in addition to ductility requirements, and upper-Lower bounds on design variables as stipulated by the specification. The optimization is carried out using the methods based on discretized continuum-type optimality criteria(DCOC). Based on Kuhn-Tucker necessary conditions, the optimality criteria are explicitly derived in terms of the design variables - effective depth, eccentricity of prestressing steel and non prestressing steel ratio. The prestressing profile is prescribed by parabolic functions. In this paper the effective depth is considered to be freely-varying and one uniform for the entire multispan beam respectively. Also the maximum eccentricity of prestressing force is considered in every span. In order to show the applicability and efficiency of the derived algorithm, several numerical examples of PRC continuous beams are solved.

Seismic Capacity Evaluation of Low-Rise Reinforced Concrete Buildings in Korea (국내 저층 철근콘크리트 건물의 내진성능 평가)

  • Lee, Kang-Seok;Kim, Yong-In;Min, Kyung-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.241-244
    • /
    • 2008
  • The authors proposed a new rapid-screening method for more reasonably evaluating seismic capacities of medium and low-rise RC buildings controlled by both shear and flexure in Ref. [1]. The method proposed in Ref. [1] was based on relationships between required strengths of each failure system for ductility factors and damage degrees of overall system derived from the view-point of ductility factors. The proposed method was also verified using observed real damage data of low-rise RC buildings caused by past earthquakes. Results indicated that the methodology proposed in Ref. [1] compares well with real damages and is a useful strategy for rapidly identifying low-rise RC buildings having high potential seismic risk. In this study, in order to verify the applicability of the new methodology proposed in Ref. [1] to real RC building systems, seismic capacities of existing eleven low-rise RC buildings in Korea are evaluated based on the new method.

  • PDF

Characterization of the Soldering Interface in Power Modules by Peel Strength Measurement (벗김강도 측정법에 의한 파워 모듈의 솔더접합 특성 평가)

  • Kim, Nam-Kyun;Lee, Hee-Heung;Bahng, Wook;Seo, Kil-Soo;Kim, Eun-Dong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1142-1149
    • /
    • 2003
  • The strength and characteristics of the soldering interface of the power semiconductor chip in a power module has been firstly surveyed by the peel strength measurement method. A power module is combined with several power chips which generally has 30∼400$\textrm{mm}^2$ chip area to allow several tens or bigger amps in current rating, so that the traditional methods for interface characterization like shear test could not be applied to high power module. In this study power diode modules were fabricated by using lead-tin solder with 10${\times}$10$\textrm{mm}^2$ or 7${\times}$7$\textrm{mm}^2$ soldering interface. The peel strengths of soldered interfaces were measured and then the microscopic investigation on the fractured surfaces were followed. The peel test indicated that the crack propagated either through the bulk of the soft lead-tin solder which has 55-60 kgf/cm peel strength or along the interface between the solder and the plated nickel layer which has much lower 22 kgf/cm strength. This study showed that the peel test would be a useful method to quantify the solderability as well as to recognize which is the worst interface or the softest material in a power module with a large soldering area.

A Study on Shear Resistance Effect along Marginal Region of Sliding Mass using 3D Slope Stability Analysis (3차원 사면안정해석을 이용한 활동지괴 가장자리부의 전단저항에 관한 연구)

  • Seo Yong-Seok;Ohta Hidemasa;Chae Byung-Gon;Yoon Woon-Sang
    • The Journal of Engineering Geology
    • /
    • v.14 no.4 s.41
    • /
    • pp.451-460
    • /
    • 2004
  • The strength of sliding plane is usually assigned on the whole sliding plane with same value in 2D limit equilibrium slope stability method. However, the potential sliding plane is divided into two or three parts which have different sliding resistances. According to the calculation results of 3D slope stability analyses using 4 types of slope cutting models, marginal sliding resistance could affect the safety of slope significantly. In this calculation two kinds of the sliding plane strengths were applied differently to the parts of bottom and margin of the model slope. The effect of marginal resistance was calculated quantitatively. In case of lower sliding resistance of the bottom, the safety factor becomes low in a margin cutting model. However, in case of higher sliding resistance of the bottom, the safety factor decreased slightly in a lower part cutting model and increased in a upper margin cutting model.

Seismic Performance of RC Column-Steel Beam Connections for Large Columns (대형기둥 적용을 위한 철근콘크리트기둥-강재보 접합부의 내진성능)

  • Park, Hong Gun;Lee, Ho Jun;Kim, Chang Soo;Hwang, Hyeon Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.4
    • /
    • pp.231-242
    • /
    • 2016
  • Earthquake resistance of RC column-steel beam (RCS) joints with simplified details were studied. Simplified details are necessary for large columns to improve the productivity and constructability. To strengthen the beam-column joint, the effects of transverse beams, studs, and U-cross ties were used. Four 2/3 scale interior RCS connections were tested under cyclic lateral loading. The specimens generally exhibited good deformation capacity exceeding 4.0% story drift ratio after yielding of both beam and beam-column joint. Ultimately, the specimens failed by shear mechanism of the joint panel. The test strengths were compared with the predictions of existing design methods.