• 제목/요약/키워드: shear bond failure

검색결과 327건 처리시간 0.031초

Microabrasive로 처리한 상아질표면에 대한 복합레진의 결합강도에 관한 연구 (A STUDY OF THE BOND STRENGTHS OF COMPOSITE RESIN TO DENTIN SURFACES PREPARED WITH MICROABRASIVE)

  • 최경규;민병순
    • Restorative Dentistry and Endodontics
    • /
    • 제22권1호
    • /
    • pp.61-75
    • /
    • 1997
  • The bond strengths of composite resin to tooth dentin vary with the methods of cavity preparation and surface treatment. Recent developments in techniques of dentinal surface treatment have renewed interest in microabrasive as a means of tooth preparation, The purpose of this study was to determine the effects of a new method of cavity preparation on the bond of composite resin to dentin. Freshly extracted 144 healthy human third molars were used in this study. The dentin surfaces prepared with #600 SiC abrasive paper were divided into control and air abrasion groups according to the method of dentin surface preparation using different combinations of delivery pressure, time, and acid etching. The shear bond strengths were measured after the composite resin (Clearfil Photo Bright) was bonded to prepared dentin surfaces by light-curing using a dentin bonding system (All-bond 2), In addition, the average surface roughness was measured to investigate the effect of differently prepared dentin surfaces on the shear bond strengths. The surface changes of prepared dentin and the debonded dentin surfaces were observed with SEM (S-2300, Hitachi Co., Japan). The following results from this-study were obtained ; 1. There was no significant difference of shear bond strengths according to the changes of delivery pressure and time. 2. The shear bond strengths were lower than the control in the air abraded-only groups, but those of the additional acid-etched groups were higher than the control. 3. The shear bond strengths to all air-abraded surfaces were increased by acid etching. 4. The correlation between shear bond strengths and surface roughness was not certain, although the mean surface roughness of all air-abraded surfaces has increased evidently while it has slightly decreased for additional acid etching. 5. On SEM examination, the dentinal tubules were almost occluded in the air abraded-only groups, but those were opened in the additional acid-etched groups. 6. The debonded surfaces were showed adhesive failure mode in the air abraded- only groups, while those were showed mainly the mixed and cohesive failure mode in the additional acid-etched groups. These results suggest that the layer produced during cavity preparation or surface treatment with air abrasion must be removed for maximum bond strength of composite resin to dentin.

  • PDF

친수성 프라이머를 이용한 교정용 브라켓 접착시의 전단결합강도에 관한 연구 (Shear bond strength of orthodontic bracket with hydrophilic primer)

  • 박철완;차경석;이진우
    • 대한치과교정학회지
    • /
    • 제32권4호
    • /
    • pp.293-300
    • /
    • 2002
  • 본 연구의 목적은 산부식된 법랑질에 수분이나 타액이 오염되어도 적절한 접착력을 얻을 수 있다고 소개된 교정용 친수성 프라이머를 이용한 교정용 브라켓 접착시 타액 오염 정도에 따른 전단결합강도와 접착 파절 양상을 기존의 소수성 프라이머와 비교함으로써 임상적 유용성을 평가하는 것이다. 사람의 소구치를 강철 원통에 교정용 레진으로 포매하여 만든 시편에 기존의 소수성인 Transbond XT primer와 친수성인 Transbond MIP primer각각에 대하여 광중합형 접착 레진으로 브라켓을 접착시, 인공 타액을 이용한 오염정도에 따른 전단결합강도를 만능시험기로 측정하고, 접착 파절 양상을 stereomicroscope로 관찰하여 다음과 같은 결과를 얻었다. 1. 건조 상태에서 Transbond XT primer와 Transbond MIP primer의 전단결합강도는 유의한 차이가 없었다. 2. 타액 오염시 그 정도에 상관없이 Transbond MIP primer는 Transbond XT primer에 비해 유의하게 높은 전단결합 강도를 나타냈다(p<0.001). 3. Transbond MIP primer는 한 겹의 타액 오염시 건조 상태와 전단결합강도의 유의한 차이가 없었으나, 두 겹의 타액 오염시에는 유의하게 낮은 결합강도를 나타냈다(p<0.01). 4. 접착 파절 형태는 타액 오염의 정도에 따라 평균 접착제 잔류 지수가 낮아지는 경향을 나타냈다. Transbond MIP primer는 타액 오염시에도 반 이상이 브라켓-레진 계면에서의 파절을 보였으나, Transbond XT primer는 타액 오염시 대부분의 경우 레진-법랑질 계면에서의 파절을 나타냈다. 이상의 실험 결과, 교정용 친수성인 Transbond MIP primer는 수분 조절이 어려운 임상 상황에서 적절한 결합강도를 얻을 수 있는 좋은 방법으로 생각된다.

염화수화물용액 침지법으로 제작한 유색 지르코니아와 전장도재의 전단결합강도 (Shear bond strength of veneer ceramic and colored zirconia by using aqueous metal chloride solutions)

  • 윤귀덕;유수경;방몽숙;양홍서;김현승;박상원
    • 대한치과보철학회지
    • /
    • 제48권2호
    • /
    • pp.151-157
    • /
    • 2010
  • 연구목적: 본 연구의 목적은 금속염화물 용액 내 침지법으로 제작된 유색 지르코니아 블록의 임상적 응용을 타진해보기 위해 지르코니아 코어와 전장도재간의 전단결합강도를 평가하고자 함이다. 연구 재료 및 방법: 지르코니아 블록은 자체 제작한 것과 시판되는 제품을 이용하였다. 색소체 용액으로 크로뮴과 몰리브데늄을 포함하는 3가지 염화수화물 용액을 제조하였고, 대조군으로 상용되고 있는 색소체 용액을 준비하였다. 가로 5 mm, 세로 5 mm, 높이 10 mm의 직육면체 지르코니아 시편을 블록마다 40개를 제작하였고, 시편을 임의로 5개 그룹으로 나누어 색소체 용액에 침지하여 유색 지르코니아를 제작한 후, 도재를 가로 5 mm, 세로 5 mm, 높이 4 mm의 직육면체가 되도록 축성하고 소결하였다. 시편의 최대 하중값과 전단결합강도를 측정하고 파절된 시편의 파절면과 파절 양상을 검사하였다. 결과:1. 지르코니아 블록간의 전단결합강도는 통계학적으로 차이를 보이지 않았다 (P > .05). 2. 무색 지르코니아와 유색 지르코니아 간의 전단결합강도는 무색이 높은 경향을 보였으나 통계학적으로 유의한 차이는 보이지 않았다 (P > .05). 3. 유색 지르코니아의 전단결합강도 비교 시 색소체 용액의 종류에 따른 통계학적인 차이는 보이지 않았다 (P > .05). 4. 지르코니아와 전장도재간의 파절은 주로 혼합성 파절 양상이 관찰되었다. 모든 시편의 전장도재 파절은 지르코니아와의 계면이나 전장도재내에서 관찰되었으며 지르코니아의 응집성 파절은 보이지 않았다. 결론:유색 지르코니아와 전장도재의 전단결합강도는 무색 지르코니아보다 더 낮은 경향을 보였지만, 관찰된 수치는 임상적으로 허용 가능한 것으로 사료된다.

치과용 금합금에 대한 금속 프라이머 처리와 열순환 처리가 교정용 브라켓의 전단결합강도에 미치는 영향 (Effect of metal primer and thermocycling on shear bonding strength between the orthodontic bracket and gold alloy)

  • 이영기;차정열;유형석;황충주
    • 대한치과교정학회지
    • /
    • 제39권5호
    • /
    • pp.320-329
    • /
    • 2009
  • 치과용 금합금에 교정용 브라켓 접착 시 금속 프라이머와 열순환 처리가 전단결합강도에 미치는 영향을 알아보기 위하여 80개의 치과용 금합금 시편을 샌드블라스팅만 처리한 군과 3종류의 금속 프라이머(Alloy Primer, Metaltite, V-Primer)처리를 시행한 군으로 분류하고, 이를 열순환 처리 시행 여부에 따라 모두 8개 군으로 분류하였다. 만능물성 시험기를 사용하여 브라켓의 전단결합강도를 측정하고, modified ARI (Adhesive Remnant Index) scores를 통해 브라켓 접착면의 파절 양상을 평가하였다. 열순환 처리 미시행 시에는 금속 프라이머의 적용 시 샌드블라스팅만 단독으로 처리한 경우에 비하여 통계적으로 유의성 있는 전단결합강도의 증가가 있었다 (p < 0.05). 열순환 처리를 시행한 군에는 금속 프라이머의 처리에 의한 전단결합강도의 변화는 유의한 차이가 없었다 (p > 0.05). 금속 프라이머를 적용한 경우 열순환 처리 미시행 시에는 파절 양상이 브라켓과 접착제 계면에서의 파절 발생 빈도가 높았으나, 열순환 처리 시행 시에는 각 군 간 파절 양상에 유의한 차이가 없었다. 이상의 결과로 금속 프라이머의 적용이 치과용 금합금에 대한 교정용 브라켓 접착 시 초기 접착 강도에서는 유의성 있는 결합력의 증가를 보이나, 열순환 처리 시행 후에는 결합 강도에서는 유의한 차이가 없는 것으로 나타나 금속 프라이머에 의한 결합력 증가가 감소하는 것으로 생각한다.

열가압 리튬 디실리케이트 전장도재와 지르코니아 하부구조의 전단결합강도 평가 (Adhesion between heat-pressed lithium disilicate veneer and zirconia framework: Shear bond strength evaluation)

  • 김재홍
    • 한국산학기술학회논문지
    • /
    • 제21권3호
    • /
    • pp.335-341
    • /
    • 2020
  • 본 연구의 목적은 shear bond strength을 이용하여 pressed lithium disilicate 전장도재와 zirconia core의 접착을 비교 분석하는 것이다. Zirconia blank(Zirtooth, HASS, Gangneung, Korea)에 각 pressed ceramic(IPS e.max Zirpress, Vita PM9, GC Initial IQ, HASS Rosetta UP)이 적용된 시편을 제작하였다(N=40). 전단결합강도를 비교 평가하기 위해 The Schmitz-Schulmeyer test method을 이용하였고 산출된 파괴하중의 값을 분석했다. 산출된 네 가지 전단결합강도 값들 간의 평균 비교는 일원분산분석(one-way ANOVA)을 통해 이루어졌고, Tukey의 사후검정을 실시하여 서로 간의 평균 차이가 통계적으로 유의함을 검증하였다. 또 파절면의 3D 분석을 통하여 파괴 표면을 관찰하여, 그 파괴 양상도 분류하였다. 실험군별 전단결합강도는 IPS e.max Zirpress 16.69±3.11MPa, VITA PM9 14.21±3.63MPa, GC Initial IQ 11.17±2.92MPa, HASS Rosetta SM 27.90±5.71MPa이었으며, Lithium disilicate ceramic veneer(HASS Rosetta SM)의 결합 강도는 다른 제품들보다 통계적으로 유의하게 높았다(p<0.05). 또, 파괴면의 유형 분류 결과, 모든 시편에서 cohesive 파괴는 관찰되지 않았고 주로 adhesive와 cohesive가 같이 조합된 파괴 유형이 관찰되었다. 본 연구 결과에 의해서 pressed lithium disilicate 전장도재가 기존의 pressed to zirconia system보다 나은 접착력을 보여주었다.

The effects of dentin bonding agent formulas on their polymerization quality, and together with tooth tissues on their microleakage and shear bond strength: an explorative 3-step experiment

  • Erfan, Mohmmad;Jafarzadeh-Kashi, Tahereh Sadat;Ghadiri, Malihe;Rakhshan, Vahid
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권5호
    • /
    • pp.333-345
    • /
    • 2014
  • PURPOSE. Bonding agents (BA) are the crucial weak link of composite restorations. Since the commercial materials' compositions are not disclosed, studies to formulize the optimum ratios of different components are of value. The aim of this study was to find a proper formula of BAs. MATERIALS AND METHODS. This explorative experimental in vitro study was composed of 4 different sets of extensive experiments. A commercial BA and 7 experimental formulas were compared in terms of degree of conversion (5 experimental formulas), shear bond strength, mode of failure, and microleakage (3 experimental formulas). Statistical analyses were performed (${\alpha}$=.05). The DC of selected formula was tested one year later. RESULTS. The two-way ANOVA indicated a significant difference between the shear bond strength (SBS) of two tissues (dentin vs. enamel, P=.0001) in a way that dentinal bonds were weaker. However, there was no difference between the four materials (P=.283). The adhesive mode of failure was predominant in all groups. No differences between the microleakage of the four materials at occlusal (P=.788) or gingival (P=.508) sites were detected (Kruskal-Wallis). The Mann-Whitney U test showed a significant difference between the microleakage of all materials (3 experimental formulas and a commercial material) together at the occlusal site versus the gingival site (P=.041). CONCLUSION. A formula with 62% bisphenol A-glycidyl methacrylate (Bis-GMA), 37% hydroxy ethyl methacrylate (HEMA), 0.3% camphorquinone (CQ), and 0.7% dimethyl-para-toluidine (DMPT) seems a proper formula for mass production. The microleakage and SBS might be respectively higher and lower on dentin compared to enamel.

교정용 광중합형 및 화학중합형 레진접착제의 전단결합강도와 파절양상에 대한 연구 (A STUDY OF SHEAR BOND STRENGTH AND FAILURE PATTERNS IN LIGHT-AND SELF-CURED ORTHODONTIC RESIN)

  • 이민하;양규호;박영준
    • 대한소아치과학회지
    • /
    • 제23권2호
    • /
    • pp.549-558
    • /
    • 1996
  • Light-cured orthodontic composite resin has been widely advertised recently for use in bonding brackets. However, the curability of light-cured resin when light waves are diffused through metal brackets in questionable. The purposes of this study were to evaluate shear bond strength and failure patterns of visible light-cured resin(Lightbond) and chemically cured-resin(Mono-Lok 2), and to determine the relative value of light-cured resin as an alternative to conventional chemically cured resin. Each of the two resins was tested on twenty extracted human first premolars. Standard edgewise metal brackets were bonded to the teeth in accordance with the manufacturers' recommendation. After bonding, the teeth were stored for 24 hours at $37^{\circ}C$, 100% humidity. The shear bond strength was tested with a universal testing machine(Instron 4302), at 0.5mm/min crosshead speed. After debonding, brackets and enamel surfaces were examined with a scanning electron microscope and a stereoscopic microscope. The results were as follows : 1. Metal brackets bonded with Lightbond showed statistically higher shear bond strength than metal brackets bonded with Mono-Lok2. 2. The predominant failure site in Lightbond was the enamel-resin interface, and in Mono-Lok 2 it was the resin itself. 3. Enamel cracks were not found in any specimen. The above results suggest that direct bonding of metal brackets to enamel with light-cured resin bonding agent can be used effectively in clinics.

  • PDF

Comparison of Shear Bond Strength in Novel Calcium Silicate-Based Materials to Composite Resin

  • Wonkyu Shin;Hyuntae Kim;Ji-Soo Song;Teo Jeon Shin;Young-Jae Kim;Jung-Wook Kim;Ki-Taeg Jang;Hong-Keun Hyun
    • 대한소아치과학회지
    • /
    • 제50권4호
    • /
    • pp.443-451
    • /
    • 2023
  • The purpose of this study was to evaluate whether the newly introduced calcium silicate-based materials with fast-setting properties could be appropriately used as basement materials in indirect pulp treatment (IPT). This was performed by quantifying the durability of adhesion between the material and composite resin, measured by the shear bond strength (SBS). Five calcium silicate-based materials, TheraCal LC® (TLC), TheraCal PT® (TPT), TheraBase® (TB), Well-RootTM PT (WPT), and Endocem® MTA (EMTA), as well as two glass ionomer-based materials, Fuji II and Fuji II LC, were included. Specimens containing these materials were manufactured and bonded to composite resin with a universal adhesive applied in self-etch mode. The SBS values and failure modes were recorded, and the mean SBSs of the materials were compared. Both TPT and TB exhibited SBS values that were similar to TLC, while both WPT and EMTA appeared to have statistically lower SBS values. Mixed failure was commonly observed in TLC and TPT, while all WPT and EMTA samples showed cohesive failure. In comparison with TLC and TPT, more samples with cohesive failure were observed in TB, implying that this material forms a stronger bond with composite resin. Together with the ability of TB to chemically bind to dentin due to its 10-methacryloyloxydecyl dihydrogen phosphate component, TB seems to be a promising material for IPT within the limitations of this in vitro study.

지르코니아-전장도재 계면의 전단결합강도에 대한 ZirLiner® 적용과 분사처리의 영향에 관한 연구 (Effect of Application of ZirLiner® and Blasting Treatments on Shear Bond Strength of Zirconia-Veneered Porcelain Interface)

  • 신영호;이유나;이해형;동진근;오상천
    • 구강회복응용과학지
    • /
    • 제24권1호
    • /
    • pp.113-127
    • /
    • 2008
  • 이 연구의 목적은 지르코니아 도재 표면의 전단 결합 강도에서 $ZirLiner^{(R)}$와 블라스팅 처리의 적용 효과를 평가하기 위한 것이다. 60개의 무색의 지르코니아 판과 30개의 색이 있는 지르코니아 판이 규격화되고 연마, 글래스블라스팅, 알루미나블라스팅, 그리고 zirliner 같은 블라스팅 처리를 적용시키는 것에 따라 10개씩 9개의 그룹으로 나누어졌다. 시편을 고정대에 위치하고 만능시험기로 전단력을 측정하였다. 파절된 견본의 파절 표면은 SEM으로 검사되었다. 각 군별 시편을 통계처리하여 그 결과를 비교하였다.

Flowable resin을 이용한 브라켓의 재접착 시 전단결합강도에 대한 연구 (Shear bond strength of rebonded orthodontic bracket with flowable resin)

  • 김동우;손우성
    • 대한치과교정학회지
    • /
    • 제35권3호
    • /
    • pp.207-215
    • /
    • 2005
  • 본 연구는 교정 치료 중 탈락된 브라켓의 재접착 시 탈락 전과 유사한 위치로 재접착하기 위하여 브라켓 탈락 전 위치의 지표가 될 수 있는 잔여 레진을 제거하지 않고 flowable resin을 이용하여 재접착을 시행하는 방법을 제안하고 이 재접착 방법의 임상적 유용성을 알아보기 위하여 시행되었다 브라켓이 탈락된 치아 표면의 잔여 레진을 제거하고 산 부식 후 Transbond XT를 이용하여 새로운 브라켓을 접착하는 통상적인 재접착 방법을 사용한 군을 대조군으로 하고 탈락된 브라켓과 치아 표면의 잔여 레진을 제거하지 않고 치면을 산부식 후 탈락된 브라켓을 Transbond XT와 CharmFil Flow로 재접착한 군을 각각 실험군으로 하였다. 실험군과 대조군의 각 군간 전단 결합강도를 비교하였으며 ARI score를 이용하여 브라켓의 탈락 양상을 관찰하였고 탈락 양상에 따른 전단결합강도를 비교하였다. 그 결과 실험군 중 Transbond XT를 이용하여 재접착한 군$(6.30\pm1.01MPa)$의 전단결합강도가 대조군$(6.51\pm1.21 MP3)$에 비하여 낮긴 하지만 통계적으로 유의한 차이가 없었으며(P=0.534), CharmFil Flow를 이용하여 재접착한 군$(7.29\pm1.54MPa)$은 Transbond XT을 이용하여 재접착한 군에 비하여 유의성 있게 높은 전단결합강도를 보였다 (P=0.009). 탈락 양상을 관찰했을 때 대조군에서는 레진 내부, 브라켓-레진, 레진-치면 간의 파절 양상이 고르게 나타났으나 실험군에서는 레진-치면간의 탈락 양상은 보이지 않았고 레진 내부. 브라켓-레진 간의 탈락이 유사하게 나타났으며 브라켓의 탈락 양상에 따른 전단결합강도의 차이는 통계적으로 유의하지 않았다. (P>0.05) 이상의 결과로 미루어보아 본 연구에서 제시된 재접착 방법과 flowable resin의 재접착제로서의 사용 가능성은 충분할 것으로 보인다.