• 제목/요약/키워드: shear behavior and performance

검색결과 665건 처리시간 0.024초

CLT-콘크리트 합성 거동을 위한 전단 연결재 부재 실험과 해석 연구 (Experimental and Analytical Study of Shear Connectors for the CLT-Concrete Composite Floor System)

  • 박아론;이기학
    • 한국공간구조학회논문집
    • /
    • 제19권1호
    • /
    • pp.65-73
    • /
    • 2019
  • This paper assesses the structural performance (force-slip response, slip modulus, and failure modes) of a CLT-concrete composite by conducting fifteen push-out test specimens. In addition, non-linear 3D finite element analysis was also developed to simulate the load-slip behavior of the CLT-concrete specimens under shear load. All 15 test specimens simulating the effect of concrete thickness, connection angle and penetration depth with four different shear connector types were built and tested to evaluate the flexural performance. Experimental results show that the maximum shear capacity for the composite action is obtained when the fixing angle is $90^{\circ}$ and the penetration depth of 95mm for SC normal screw was used to achieve ductile failure compared to other shear connectors.

Seismic behavior of double steel plates and concrete filled composite shear walls subject to in-plane cyclic load: Experimental investigation

  • Xiaohu Li;Hao Luo;Xihao Ren;Tao Zhang;Lei Li;Ke Shi
    • Structural Engineering and Mechanics
    • /
    • 제90권4호
    • /
    • pp.345-356
    • /
    • 2024
  • This paper aims to investigate the seismic behavior of double steel plate and concrete composite shear wall (DSCW) of shield buildings in nuclear power engineering through experimental study. Hence, a total of 10 specimens were tested to investigate the hysteretic performance of DSCW specimens in detail, in terms of load vs. displacement hysteretic curves, skeleton curves, failure modes, flexural strength, energy dissipation capacity. The experimental results indicated that the thickness of steel plate, vertical load and stiffener have great influence on the shear bearing capacity of shear wall, and the stud space has limited influence on the shear capacity. And finally, a novel simplified formula was proposed to predict the shear bearing capacity of composite shear wall. The predicted results showed satisfactory agreement with the experimental results.

프리스트레스가 도입된 강섬유보강콘크리트의 균열면 전단거동 (Shear Behavior of Prestressed Steel Fiber-Reinforced Concrete at Crack Interfaces)

  • 갈경완;황진하;이득행;김강수;최일섭
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.78-88
    • /
    • 2012
  • 일반적으로 콘크리트는 경제성이 뛰어나지만 낮은 인장강도로 인하여 구조성능상의 한계를 가지고 있기 때문에 콘크리트와 결합된 다양한 합성재료의 특성을 활용한 구조부재의 개발이 진행되고 있다. 강섬유 보강 콘크리트(SFRC)는 높은 인장강도로 인하여 콘크리트의 재료적 단점을 보완할 수 있는 우수한 합성재료로서 알려져 있고, 특히 고강도 콘크리트의 화재시 폭렬현상에 대한 대안으로 여겨지고 있다. 또한, 프리스트레스트콘크리트(PSC) 부재는 장경간 구조에 매우 유리하며 일반철근콘크리트(RC) 부재에 비해 높은 전단강도를 가진다. 따라서, 이 연구에서는 SFRC에 프리스트레스를 적용한 강섬유 보강 프리스트레스트 콘크리트(SFR-PSC)부재의 전단거동을 이해하기 위하여 총 22개의 직접전단실험체를 제작하여 실험을 수행하였다. 또한, 실험결과를 바탕으로 SFR-PSC부재의 균열면에서의 균열전달 구성방정식을 제안하였다. SFR-PSC의 거동특성을 반영하여 제안된 재료관계식은 실험결과와 잘 일치하는 것으로 나타났다.

비선형 동적해석을 이용한 소규모 필로티형 철근콘크리트 건축물의 내진성능평가 (Seismic Performance Evaluation of Small-size Pilloti-type Reinforced Concrete Buildings using Nonlinear Dynamic Analysis)

  • 유창환;김태완;추유림
    • 한국지진공학회논문집
    • /
    • 제20권4호
    • /
    • pp.191-199
    • /
    • 2016
  • Piloti-type building is one of typical vertical atypical buildings. These buildings can fail by weak-story or flexible-story mechanism on the first story. They should be designed by taking into account the special seismic load, but those less than six stories are not required to confirm the seismic performance from structural engineers in Korea. For this reason, small-size pilloti-type RC buildings need to be checked for seismic performance. Based on this background, this study performed nonlinear dynamic analysis using the PERFORM-3D for small-size pilloti-type RC buildings and assessed their seismic performance. Examples are two through four story buildings with and without walls in the first story. The walls and columns in the first story satisfied the target performance in the basic of flexural behavior due to quite a large size and reinforcement. However, wall shear demands exceed shear strength in some buildings. When designed for KBC2009, wall shear strength exceed shear demand in some buildings, but still does not in others. Consequently, wall shear must be carefully checked in both existing and new small-size pilloti-type RC buildings.

계면요소를 이용한 경량철근콘크리트 보의 전단거동해석 (Analysis of Shear Behavior of Reinforced ALWAC Beam Using Interface Elements)

  • 이인규;김우
    • 대한토목학회논문집
    • /
    • 제26권1A호
    • /
    • pp.107-115
    • /
    • 2006
  • 전단보강이 없는 철근콘크리트 보의 파괴특성의 정의는 현재까지는 어려운 주제이다. 과거의 본질적인 실험적 연구와 이론적인 노력에도 불구하고 전단파괴의 특성은 완전히 이해되지 않았다. 따라서 보의 설계시 전단강도 산정에 반경험식의 적용이 되어오고 있다. 최근의 다양한 건설환경 하에서 고성능 콘크리트의 수요가 증가하고 있으며 내구성을 포함한 가격경쟁력이 뛰어난 재료들이 필요하며 특히 경량철근콘크리트의 경우에는 경량이면서 적절한 강도를 가지고 온도와 소음차단에 효과적이기 때문에 주요부재 및 구조물에 응용할 수 있다. 이러한 장점에도 불구하고 그의 극한파괴거동에 대해서는 다소 잘 정리되어 있지 않다. 이러한 이유로 본 연구에서는 경량철근콘크리트 보의 전단거동을 살펴보며 그의 특이성을 기존 실험적 연구와 해석적 연구를 통해 비교, 검토하고자 하였다.

휨강도와 전단강도의 확률분포를 고려한 연결보의 성능기반설계 (Performance Based Design of Coupling Beam Considering Probability Distribution of Flexural and Shear Strength)

  • 김윤곤;조석희
    • 콘크리트학회논문집
    • /
    • 제25권5호
    • /
    • pp.509-516
    • /
    • 2013
  • 이 연구에서는 휨힌지를 유도하기 위해 휨강도와 전단강도의 확률분포를 고려한 연결보의 성능기반설계법을 제안하였다. 이 방법은 연결보의 항복 이후 거동과 시스템의 재분배를 반영하므로 현행 선형해석 기반의 연결보 설계에서 임의로 저감된 유효강성의 적합성을 검증할 수 있으며, 사용하중에서의 연결보의 실제 강성을 반영하여 횡변위를 평가하는데 적정하다. 또한 부재간 내력 재분배를 고려할 수 있어 병렬전단벽의 최적설계가 가능할 것으로 판단된다. 이 설계법의 적합성을 검증하기 위해 단순화된 30층 오피스 건물을 대상으로 비선형정적해석을 수행하고 성능점 및 각 스텝의 구조성능을 검토하였다. 또한 사용하중의 부재강성을 평가하고 극한하중의 부재 강성을 사용한 시스템의 거동과 비교하였다. 또한 연결보의 다양한 배근 및 보 춤에 따른 시스템의 거동특성을 비교, 분석하였다.

Seismic performance of beam-to- SST column connection with external diaphragm

  • Rong, Bin;Yin, Shuhao;Zhang, Ruoyu;Wang, Lei;Yang, Ziheng;Li, Hongtao;Wan, Wenyu
    • Steel and Composite Structures
    • /
    • 제37권6호
    • /
    • pp.633-647
    • /
    • 2020
  • This paper aims to study the seismic performance of external diaphragm connection between SST (square steel tube) column and H-shaped beam through experimental and analytical study involving finite element (FE) method and theoretical analysis. In the experimental study, three external diaphragm connection specimens with weak panel zone were tested under axial pressure on the top of the column and antisymmetric cyclic loads at the beam end to investigate the seismic performance of the panel zone. The hysteretic behavior, failure mode, stiffness and ductility of the specimens were discussed. Key point to be explored was the influence of the thickness of the steel tube flange on the shear capacity of the specimens. In the analytical study, three simplified FE models were developed to simulate the seismic behavior of the specimens for further analysis on the influence of steel tube flange. Finally, four existing calculation formulas for the shear capacity of the external diaphragm connection were evaluated through comparisons with the results of experiments and FE analysis, and application suggestions were put forward.

Static behavior of high strength friction-grip bolt shear connectors in composite beams

  • Xing, Ying;Liu, Yanbin;Shi, Caijun;Wang, Zhipeng;Guo, Qi;Jiao, Jinfeng
    • Steel and Composite Structures
    • /
    • 제42권3호
    • /
    • pp.407-426
    • /
    • 2022
  • Superior to traditional welded studs, high strength friction-grip bolted shear connectors facilitate the assembling and demounting of the composite members, which maximizes the potential for efficiency in the construction and retrofitting of new and old structures respectively. Hence, it is necessary to investigate the structural properties of high strength friction-grip bolts used in steel concrete composite beams. By means of push-out tests, an experimental study was conducted on post-installed high strength friction-grip bolts, considering the effects of different bolt size, concrete strength, bolt tensile strength and bolt pretension. The test results showed that bolt shear fracture was the dominant failure mode of all specimens. Based on the load-slip curves, uplifting curves and bolt tensile force curves between the precast concrete slab and steel beam obtained by push-out tests, the anti-slip performance of steel-concrete interface and shear behavior of bolt shank were studied, including the quantitative analysis of anti-slip load, and anti-slip stiffness, frictional coefficient, shear stiffness of bolt shank and ultimate shear capacity. Meanwhile, the interfacial anti-slip stiffness and shear stiffness of bolt shank were defined reasonably. In addition, a total of 56 push-out finite element models verified by the experimental results were also developed, and used to conduct parametric analyses for investigating the shear behavior of high-strength bolted shear connectors in steel-concrete composite beams. Finally, on ground of the test results and finite element simulation analysis, a new design formula for predicting shear capacity was proposed by nonlinear fitting, considering the bolt diameter, concrete strength and bolt tensile strength. Comparison of the calculated value from proposed formula and test results given in the relevant references indicated that the proposed formulas can give a reasonable prediction.

신소재 및 성능개선 디테일을 활용한 철근콘크리트 골조면내 전단벽의 내진성능 개선기술 (New Technique of Earthquake Resistant Performance of Reinforced Concrete Infilled Shear Wall using New Materials and Advanced Detailing)

  • 하기주;신종학;김윤용;양승혁;홍건호;김정수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.202-205
    • /
    • 2006
  • Three reinforced concrete shear wall and infilled shear wall using retrofitting system were constructed and tested under both vertical and cyclic loadings, Experimental programs were carried out to evaluate and improve the seismic performance of such test specimens, such as the hysteretic behavior, the maximum horizontal strength, crack propagation, and ductility etc. under load reversals. All the specimens were modeled in one-third scale size. For specimens(RWAHC, RWXHC) designed by the improving of seismic performance using the high ductile fiber composite mortar, anchoring, and advanced detailing system for the reinforced concrete shear wall load-carrying capacities were increased $1.1{\sim}1.22$ times in comparison with the standard specimen(SRW).

  • PDF

Effect of ages and season temperatures on bi-surface shear behavior of HESUHPC-NSC composite

  • Yang Zhang;Yanping Zhu;Pengfei Ma;Shuilong He;Xudong Shao
    • Advances in concrete construction
    • /
    • 제15권6호
    • /
    • pp.359-376
    • /
    • 2023
  • Ultra-high-performance concrete (UHPC) has become an attractive cast-in-place repairing material for existing engineering structures. The present study aims to investigate age-dependent high-early-strength UHPC (HESUHPC) material properties (i.e., compressive strength, elastic modulus, flexural strength, and tensile strength) as well as interfacial shear properties of HESUHPC-normal strength concrete (NSC) composites cured at different season temperatures (i.e., summer, autumn, and winter). The typical temperatures were kept for at least seven days in different seasons from weather forecasting to guarantee an approximately consistent curing and testing condition (i.e., temperature and relative humidity) for specimens at different ages. The HESUHPC material properties are tested through standardized testing methods, and the interfacial bond performance is tested through a bi-surface shear testing method. The test results quantify the positive development of HESUHPC material properties at the early age, and the increasing amplitude decreases from summer to winter. Three-day mechanical properties in winter (with the lowest curing temperature) still gain more than 60% of the 28-day mechanical properties, and the impact of season temperatures becomes small at the later age. The HESUHPC shrinkage mainly occurs at the early age, and the final shrinkage value is not significant. The HESUHPC-NSC interface exhibits sound shear performance, the interface in most specimens does not fail, and most interfacial shear strengths are higher than the NSC-NSC composite. The HESUHPC-NSC composites at the shear failure do not exhibit a large relative slip and present a significant brittleness at the failure. The typical failures are characterized by thin-layer NSC debonding near the interface, and NSC pure shear failure. Two load-slip development patterns, and two types of main crack location are identified for the HESUHPC-NSC composites tested in different ages and seasons. In addition, shear capacity of the HESUHPC-NSC composite develops rapidly at the early age, and the increasing amplitude decreases as the season temperature decreases. This study will promote the HESUHPC application in practical engineering as a cast-in-place repairing material subjected to different natural environments.