DOI QR코드

DOI QR Code

Shear Behavior of Prestressed Steel Fiber-Reinforced Concrete at Crack Interfaces

프리스트레스가 도입된 강섬유보강콘크리트의 균열면 전단거동

  • 갈경완 (연우건축구조기술사사무소) ;
  • 황진하 (서울시립대학교 건축공학과) ;
  • 이득행 (서울시립대학교 건축공학과) ;
  • 김강수 (서울시립대학교 건축학부) ;
  • 최일섭 (연우건축구조기술사사무소)
  • Received : 2011.08.02
  • Accepted : 2011.10.31
  • Published : 2012.01.30

Abstract

Although structural concrete is well known for its good economic efficiency, it has limits of structural performance due to the low tensile strength, for which new structural members utilizing various concrete composite materials have been developed. Steel Fiber-Reinforced Concrete(SFRC) has great tensile strength, which is the one of the excellent composite material to complement the weakness of concrete, and it is also considered as a good alternative to prevent the explosive failure of high strength concrete under fire. Also, prestressed concrete members are of great advantages to long span structures and have greater shear strength compared to conventional reinforced concrete members. In this research, thus, a total of 22 direct shear test specimens were fabricated and tested to understand the shear behavior of Steel Fiber-Reinforced Prestressed Concrete(SFR-PSC) members, in which SFRC members combined with prestressing method. Based on the test results, the constitutive equations of shear behavior at crack interfaces were proposed, which provided good estimation on the shear behavior of the SFR-PSC direct shear test specimens.

일반적으로 콘크리트는 경제성이 뛰어나지만 낮은 인장강도로 인하여 구조성능상의 한계를 가지고 있기 때문에 콘크리트와 결합된 다양한 합성재료의 특성을 활용한 구조부재의 개발이 진행되고 있다. 강섬유 보강 콘크리트(SFRC)는 높은 인장강도로 인하여 콘크리트의 재료적 단점을 보완할 수 있는 우수한 합성재료로서 알려져 있고, 특히 고강도 콘크리트의 화재시 폭렬현상에 대한 대안으로 여겨지고 있다. 또한, 프리스트레스트콘크리트(PSC) 부재는 장경간 구조에 매우 유리하며 일반철근콘크리트(RC) 부재에 비해 높은 전단강도를 가진다. 따라서, 이 연구에서는 SFRC에 프리스트레스를 적용한 강섬유 보강 프리스트레스트 콘크리트(SFR-PSC)부재의 전단거동을 이해하기 위하여 총 22개의 직접전단실험체를 제작하여 실험을 수행하였다. 또한, 실험결과를 바탕으로 SFR-PSC부재의 균열면에서의 균열전달 구성방정식을 제안하였다. SFR-PSC의 거동특성을 반영하여 제안된 재료관계식은 실험결과와 잘 일치하는 것으로 나타났다.

Keywords

References

  1. 갈경완, "강섬유보강콘크리트 부재의 균열면 전단전달", 서울시립대학교 석사학위논문, 2011년 2월, pp.212.
  2. 갈경완, 김강수, 이득행, 황진하, 오영훈, "강섬유로 보강된 콘크리트 보의 전단강도에 관한 실험적 연구", 구조물진단학회논문집, 제14권 3호, 2010, pp.160-170.
  3. 갈경완, 김강수, 이득행, 황진하, 주현진, 서수연, "강섬유로 보강된 고강도 콘크리트 보의 전단강도에 관한 실험적 연구", 대한건축학회논문집(구조계), 제26권 10호, 2010, pp.19-28.
  4. 김우석, 백승민, 이정석, 권진환, 곽윤근, "강섬유보강 콘크리트보의 휨내력에 관한 연구", 대한건축학회 논문집, 제18권 9호, 2002, pp.3-11.
  5. 오영훈, 김정해, "전단보강이 없는 강섬유보강 콘크리트 휨부재의 휨 및 전단강도의 평가", 한국콘크리트학회 논문집, 제20권 2호, 2008, pp.257-267. https://doi.org/10.4334/JKCI.2008.20.2.257
  6. 한국콘크리트학회, "주거용 건물의 PT공법 최적화 연구", 2008, pp.256.
  7. 한민철, 한천구, "고성능 콘크리트의 폭렬특성 및 대책", 한국콘크리트학회 봄 학술발표회 논문집, 제20권 1호, 2008, pp.1105-1108.
  8. Ashour, S. A., Hasanain, G. S. and Wafa, F. F., "Shear Behavior of High-Strength Fiber-Reinforced Concrete Beams", ACI Structural Journal, vol. 89, No. 2, 1992, pp.176-184.
  9. Barragan, B., Gettu, R., Agullo, L. and Zerbino, R., "Shear Failure of Steel Fiber-Reinforced Concrete Based on Push-Off Tests", ACI Materials Journal, vol. 103, No. 4, 2006, pp.251-257.
  10. Batson, G., Jenkins, E. and Spatney, R., "Steel Fibers as Shear Reinforcement in Beams", ACI Journal, Proceedings, vol. 69, No. 10, 1972, pp.640-644.
  11. Cho, S. H. and Kim Y. I., "Effect of Steel Fibers on Short Beams Loaded in Shear", ACI Structural Journal, vol. 100, No. 6, 2003, pp.765-774.
  12. Cucchiara, C., Mendola, L. L. and Papia, M., "Effectiveness of Stirrups and Steel Fibers as Shear Reinforcement", Cement and Concrete Composites, vol. 26, No. 7, 2004, pp.777-786. https://doi.org/10.1016/j.cemconcomp.2003.07.001
  13. D. Kuchma., K. S. Kim., Thomas J. Nagle., S. Sun and N. M. Hawkins., "Shear Tests on High-Strength Prestressed Bulb-Tee Girders: Strengths and Key Observations", ACI Structural Journal, vol. 105, No. 3, 2008, pp.358-367.
  14. Khaloo, A. R. and Kim, N., "Influence of Concrete and Fiber Characteristics on Behavior of Steel Fiber Reinforced Concrete under Direct Shear", ACI Materials Journal, vol. 94, No. 6, 1997, pp.592-601.
  15. Li, V. C. and Obla, K., "Effect of FIber Diameter Variation on Properties of Cement-Based Matrix Fiber Reinforced Composites", Composites Part B: Engineering, vol. 27, No. 3-4, 1996, pp.275-284. https://doi.org/10.1016/1359-8368(95)00031-3
  16. Li, V. C., Wang, S. and Wu, C., "Tensile Strain- Hardening Behavior of Polyvinyl Alcohol Engineered Cementitious Composite (PVA-ECC)", ACI Materials Journal, vol. 98, No. 6, 2001, pp.483-492.
  17. Narayanan, R. and Darwish, I. Y. S., "Shear in Prestressed Concrete Beams Containing Steel Fibers", International Journal of Cement Composites and Lightweight Concrete, vol. 9, No. 2, 1987, pp.81-90. https://doi.org/10.1016/0262-5075(87)90023-6
  18. Padmarajaiah, S. K. and Ramaswamy, A., "Behavior of Fiber-Reinforced Prestressed and Reinforced High- Strength Concrete Beams Subjected to Shear", ACI Structural Journal, vol. 98, No. 5, 2001, pp.752-761.
  19. Padmarajaiah, S. K. and Ramaswamy, A., "Crack-Width Prediction for High-Strength Concrete Fully and Partially Prestressed Beam Specimens Containing Steel Fibers", ACI Structural Journal, vol. 98, No. 6, 2001, pp.852-861.
  20. Padmarajaiah, S. K. and Ramaswamy, A., "Flexural Strength Predictions of Steel Fiber Reinforced High- Strength Concrete in Fully/Partially Prestressed Beam Specimens", Cement and Concrete Composites, vol. 26, No. 4. 2004, pp.275-290. https://doi.org/10.1016/S0958-9465(02)00121-X
  21. Swamy, R. N. and Mangat, P. S, "Influrence of fibreaggregate interaction on some properties of steel fibre reinforced concrete", Materials and Structures, vol. 7, No. 5, 1994, pp.307-314.
  22. Swamy, R. N., Mangat, P. S. and Rao, C. V., "Mechanics of Fiber Reinforcement of Cement Matrices", Fiber Reinforced Concrete, SP-44, American Concrete Institute, 1974, pp.1-28.
  23. Swamy, R., Jones, R. and Chiam, T., "Shear Transfer in Steel Fiber Reinforced Concrete", Fiber Reinforced Concrete Properties and Application, SP105-29, American Concrete Institute, Detroit, 1987, pp.565-592.
  24. Tan, K. H., Paramasivam, P. and Murugappan, K., "Steel Fibers as Shear Reinforcement in Partially Prestressed Beams", ACI Structural Journal, vol. 92, No. 6, 1995, pp.642-652.
  25. Thomas, J. and Ramaswamy, A., "Crack Width in Partially Prestressed T-Beams Having Steel Fibers", ACI Structural Journal, vol. 103, No. 4, 2006, pp.568-576.
  26. Thomas, J. and Ramaswamy, A., "Shear Strength of Prestressed Concrete T-Beams with Steel Fibers Over Partial/Full Depth", ACI Structural Journal, vol. 103, No. 3, 2006, pp.427-435.