• 제목/요약/키워드: sharp temperature change

검색결과 61건 처리시간 0.03초

RF 스퍼터링법으로 사파이어 기판 위에 성장한 ZnO와 ZnO : A1 박막의 질소 및 수소 후열처리에 따른 Photoluminescence 특성 (A study of the photoluminescence of undoped ZnO and Al doped ZnO single crystal films on sapphire substrate grown by RF magnetron sputtering)

  • 조정;윤기현;정형진;최원국
    • 한국재료학회지
    • /
    • 제11권10호
    • /
    • pp.889-894
    • /
    • 2001
  • 2wt% $Al_2O_3-doped$ ZnO (AZO) thin films were deposited on sapphire (0001) single crystal substrate by parellel type rf magnetron sputtering at 55$0^{\circ}C$. The as-grown AZO thin films was polycrystalline and showed only broad deep defect-level photoluminescence (PL). In order to examine the change of PL property, AZO thin films were annealed in $N_2$ (N-AZO) and $H_2$ (H-AZO) at the temperature of $600^{\circ}C$~$1000^{\circ}C$ through rapid thermal annealing. After annealed at $800^{\circ}C$, N-AZO shows near band edge emission (NBE) with very small deep-level emission, and then N-AZO annealed at $900^{\circ}C$ shows only sharp NBE with 219 meV FWHM. In Comparison with N-AZO, H-AZO exhibits very interesting PL features. After $600^{\circ}C$ annealing, deep defect-level emission was quire quenched and NBE around 382 nm (3.2 eV) was observed, which can be explained by the $H_2$passivation effect. At elevated temperature, two interesting peaks corresponding to violet (406 nm, 3.05 eV) and blue (436 nm, 2.84 eV) emission was firstly observed in AZO thin films. Moreover, peculiar PL peak around 694 nm (1.78 eV) is also firstly observed in all the H-AZO thin films and this is believed good evidence of hydrogenation of AZO. Based on defect-level scheme calculated by using the full potential linear muffin-tin orbital (FP-LMTO), the emission 3.2 eV, 3.05 eV, 3.84 eV and 1.78 eV of H-AZO are substantially deginated as exciton emission, transition from conduction band maximum to $V_{ Zn},$ from $Zn_i$, to valence band maximum $(V_{BM})$ and from $V_{o} to V_BM}$, respectively.

  • PDF

반도체 웨이퍼 제조공정 클린룸 구조, 공기조화 및 오염제어시스템 (Clean Room Structure, Air Conditioning and Contamination Control Systems in the Semiconductor Fabrication Process)

  • 최광민;이지은;조귀영;김관식;조수헌
    • 한국산업보건학회지
    • /
    • 제25권2호
    • /
    • pp.202-210
    • /
    • 2015
  • Objectives: The purpose of this study was to examine clean room(C/R) structure, air conditioning and contamination control systems and to provide basic information for identifying a correlation between the semiconductor work environment and workers' disease. Methods: This study was conducted at 200 mm and 300 mm semiconductor wafer fabrication facilities. The C/R structure and air conditioning method were investigated using basic engineering data from documentation for C/R construction. Furthermore, contamination parameters such as airborne particles, temperature, humidity, acids, ammonia, organic compounds, and vibration in the C/R were based on the International Technology Roadmap for Semiconductors(ITRS). The properties of contamination control systems and the current status of monitoring of various contaminants in the C/R were investigated. Results: 200 mm and 300 mm wafer fabrication facilities were divided into fab(C/R) and sub fab(Plenum), and fab, clean sub fab and facility sub fab, respectively. Fresh air(FA) is supplied in the plenum or clean sub fab by the outdoor air handling unit system which purifies outdoor air. FA supply or contaminated indoor air ventilation rates in the 200 mm and 300 mm wafer fabrication facilities are approximately 10-25%. Furthermore, semiconductor clean rooms strictly controlled airborne particles(${\leq}1,000{\sharp}/ft^3$), temperature($23{\pm}0.5^{\circ}C$), humidity($45{\pm}5%$), air velocity(0.4 m/s), air change(60-80 cycles/hr), vibration(${\leq}1cm/s^2$), and differential pressure(atmospheric pressure$+1.0-2.5mmH_2O$) through air handling and contamination control systems. In addition, acids, alkali and ozone are managed at less than internal criteria by chemical filters. Conclusions: Semiconductor clean rooms can be a pleasant environment for workers as well as semiconductor devices. However, based on the precautionary principle, it may be necessary to continuously improve semiconductor processes and the work environment.

Er:YAG 레이저의 상아질 삭제효과 및 이에 따른 온도변화 (ANALYSIS OF ER:YAG LASER IRRADIATION ON CUTTING EFFICACY AND TEMPERATURE CHANGES OF DENTIN)

  • 임광호;이창섭;이상호
    • 대한소아치과학회지
    • /
    • 제28권1호
    • /
    • pp.32-44
    • /
    • 2001
  • Er : YAG 레이저의 상아질 삭제효과와 이에 따른 온도변화를 평가하고자 발거된 소구치와 대구치로 상아세관내 조직액과 치수내압을 유지할 수 있는 상아질 시편을 제작하고 $2.94{\mu}m$의 pulsed Er : YAG 레이저(SDL-300EN, 삼성전자, 한국)를 handpiece형의 전달계를 이용한 비접촉식 방법으로 조사세기, pulse repetition rate, 조사시간, 물 분사여부 등의 조사조건을 달리하여 상아질 면에 조사하고 이때의 삭제량과 상아질 두께에 따른 온도변화, 그리고 삭제형태를 조사, 분석하여 다음과 같은 결과를 얻었다. 1. 레이저 조사세기와 pulse repetition rate가 클수록, 그리고 조사시간이 길수록 삭제량이 증가되었다(P<0.05). 그러나 5Hz의 pulse repetition rate에서는 조사시간에 따른 삭제량의 차이가 크지 않았다. 2. 삭제된 와동은 비교적 변연부가 명확하고 깨끗하였으며 와동의 바닥은 원추형이였으며 부드러웠다. 조사세기와 pulse repetition rate가 클수록, 그리고 조사시간이 길수록 와동의 상부 직경이 넓었으며 150mJ, 5Hz, 5sec에서는 와동변연부에 약간의 crack이 관찰되었다. 3. 레이저 조사세기와 pulse repetition rate가 클수록, 그리고 조사시간이 길수록 상아질의 온도가 더 많이 상승하였으며 시편의 두께가 두꺼울수록 온도상승이 적었다(P<0.05). 4. 물을 분사하며 레이저를 조사할 경우 물을 분사하지 않은 경우에 비해 온도상승이 매우 감소되었다(P<0.05). 이상의 결과를 종합해 볼 때 Er : YAG 레이저를 상아질에 조사할 경우 와동의 형태가 명확하고 물을 분사할 경우 온도상승이 많이 유발되지 않으므로써 삭제력이 좋고 치수에 유해작용이 없는 것으로 생각된다. 향후 임상에서 치질을 제거하는데 효율적으로 이용되기 위해서는 더욱 크고 이에 따른 온도상승을 최소로 할 수 있는 조사 시스템 및 방법에 대한 연구가 계속적으로 이루어져야 할 것으로 사료된다.

  • PDF

조류 바이오매스를 이용한 토양개량제의 퇴비화 과정에 따른 영양성분 특성 (Nutritional Properties by Composting Process of Algae Biomass as Soil Conditioner)

  • 안창혁;이새로미;박재로
    • 환경영향평가
    • /
    • 제28권6호
    • /
    • pp.604-615
    • /
    • 2019
  • 본 연구에서는 폐기되는 조류 바이오매스를 재활용하여 퇴비화 과정을 통해 새로운 형태의 조류토양개량제(algae soil conditioner, ASC)로 제조하고 영양성분에 대한 특성을 평가하였다. ASCs는 응집부상공법을 통해 수집된 조류 바이오매스를 주원료로 하였으며 추가적으로 다양한 보조 원료(톱밥, 펄라이트, 깻묵 등)를 첨가하여 제조하였다. ASCs는 투입된 조류 바이오매스 질량 비율에 따라 각각 blank 0%, ASC1 11.7%, ASC2 21.6%, ASC3 37.6%, ASC4 59.5%로 구분하여 총 127일간 부숙하였다. ASCs는 호기성 미생물 반응에 의해 온도 증감이 뚜렷하게 나타났으며 6~7회의 크고 작은 온도 피크가 관찰되었다. 이화학 분석결과 유기물이 무기화(mineralization) 되면서 macronutrients (TN, P2O5, K2O) 뿐만 아니라 secondary macronutrients (CaO, MgO)에서도 두드러진 증가를 보였다. 미생물 군집변화는 ASCs의 부숙과정에 따라 1단계(세균, 사상균)→2단계(방선균, 세균)→3단계(고초균)로 나타났으며 온도변화와 영양성분의 거동과 밀접한 관련이 있다고 판단되었다. 부숙 완성도에 따라 토양개량제의 품질이 결정될 수 있으며 본 연구결과에서는 조류 바이오매스를 59.5% 이내로 조절한다면 효과적인 미생물 활성을 유도할 수 있을 것으로 판단되었다. 결론적으로 조류 바이오매스를 재활용한 토양개량제의 제조 및 활용 가능성을 확인하였으며 추가적인 기술적 발전이 이루어진다면 향후 효과적인 토양개량제로 활용할 수 있을 것으로 판단된다.

국산 백침계 오이와 수출용 백침계 오이의 오이 물김치 제조가 저장 중 품질에 미치는 영향 (The Properties of Cucumber Kimchi of Different Species during Fermentation)

  • 이혜정;김정근;고종명;허명제
    • 한국식품영양학회지
    • /
    • 제15권3호
    • /
    • pp.241-249
    • /
    • 2002
  • 국산 백침계 오이와 수출용 백침계 오이로 제조한 오이 물김치의 저장 중 변화는 다음과 같다. 1. pH는 적정 pH인 3.5$\pm$0.1에 이르는 시기가 세 시료 모두 14일로 이 수준은 백다다기 오이로 7% 용액에 CaCl$_2$ 첨가 및 microwave를 이용한 후 열처리군과 유사한 경향을 보였다. 2. 총산도의 변화는 발효 완결 기준을 1.4$\pm$0.1%로 볼 때 대조군은 14일, 수출용 오이들은 7일로 대조군이 수출용 오이들에 비해 발효가 지연되는 경향을 보였다. 3. 환원당의 변화는 대조군이 14일부터 감소하고, 수출용 오이들은 지속적으로 감소 추세를 보였고 대조군은 미생물 증식 속도가 늦은 경향을 보였다. 4. 총균수는 세 품종 모두 발효 적기인 14일에 최대 균수를 보인 후에도 증가가 계속되어 발효가 서서히 진행되는 경향을 보였다. 5. 세 품종의 젖산균수도 총균수의 변화와 경향은 유사했으나 발효 적기인 14일에 최대균수를 보인 후 발효말기까지 큰 변화를 나타내지 않았다. 6. 물성도의 변화는 저장 14일 째에 측정한 결과 견고도는 대조군이 수출용 오이들보다 높은 것으로 나타났다. 7. 관능 검사 결과 저장 기간 동안 외관은 세 시료 모두 높은 값을 나타냈고, 저장기간과 시료간의 Pearson의 상관 계수는 초록색의 정도와 아작함이 유의 수준내에서 음의 관계를 보였다.

RF 마그네트론 스퍼터를 이용하여 제작한 MGZO 박막의 구조적 및 전기적, 광학적 특성에 미치는 스퍼터링 전력의 영향 (Effect of Sputtering Powers on Mg and Ga Co-Doped ZnO Thin Films with Transparent Conducting Characteristics)

  • 김인영;신승욱;김민성;윤재호;허기석;정채환;문종하;이정용;김진혁
    • 한국재료학회지
    • /
    • 제23권3호
    • /
    • pp.155-160
    • /
    • 2013
  • ZnO thin films co-doped with Mg and Ga (MxGyZzO, x + y + z = 1, x = 0.05, y = 0.02 and z = 0.93) were prepared on glass substrates by RF magnetron sputtering with different sputtering powers ranging from 100W to 200W at a substrate temperature of $350^{\circ}C$. The effects of the sputtering power on the structural, morphological, electrical, and optical properties of MGZO thin films were investigated. The X-ray diffraction patterns showed that all the MGZO thin films were grown as a hexagonal wurtzite phase with the preferred orientation on the c-axis without secondary phases such as MgO, $Ga_2O_3$, or $ZnGa_2O_4$. The intensity of the diffraction peak from the (0002) plane of the MGZO thin films was enhanced as the sputtering power increased. The (0002) peak positions of the MGZO thin films was shifted toward, a high diffraction angle as the sputtering power increased. Cross-sectional field emission scanning electron microscopy images of the MGZO thin films showed that all of these films had a columnar structure and their thickness increased with an increase in the sputtering power. MGZO thin film deposited at the sputtering power of 200W showed the best electrical characteristics in terms of the carrier concentration ($4.71{\times}10^{20}cm^{-3}$), charge carrier mobility ($10.2cm^2V^{-1}s^{-1}$) and a minimum resistivity ($1.3{\times}10^{-3}{\Omega}cm$). A UV-visible spectroscopy assessment showed that the MGZO thin films had high transmittance of more than 80 % in the visible region and that the absorption edges of MGZO thin films were very sharp and shifted toward the higher wavelength side, from 270 nm to 340 nm, with an increase in the sputtering power. The band-gap energy of MGZO thin films was widened from 3.74 eV to 3.92 eV with the change in the sputtering power.

셀로비오스 옥타(콜레스테릴옥시카보닐)알카노에이트의 열 및 광학 특성 (Thermal and Optical Properties of Cellobiose Octa(cholesteryloxycarbonyl)alkanoates)

  • 정승용;마영대
    • 폴리머
    • /
    • 제32권3호
    • /
    • pp.230-238
    • /
    • 2008
  • 셀로비오스 옥타(콜레스테릴옥시카보닐)알카노에이트(CCBn, $n=2{\sim}8$,10, 스페이서중의 메틸렌 단위들의 수)의 열 및 광학 특성을 검토하였다. 모든 시료들은 좌측방향의 나선구조를 지닌 단방성 콜레스테릭 상들을 형성하였다. n=2 혹은 10인 CCBn은 $3{\leq}n{\leq}8$인 CCBn과 달리 콜레스테릭 상의 전 온도구간에서 반사색깔을 나타내지 않았다. 이러한 사실은 콜레스테릴 그룹에 의한 나선의 비틀림력은 콜레스테릴 그룹과 셀로비오스 사슬을 연결하는 스페이서의 길이에 민감하게 의존함을 시사한다. 액체 상에서 콜레스테릭 상으로의 전이온도($T_{ic}$)와 유리전이온도는 n이 증가함에 따라 낮아지며 홀수-짝수 효과를 나타내지 않았다. $T_{ic}$에서의 전이엔트로피는 n이 2에서 6까지 증가하나 n=7에서 급격히 감소한 후 재차 n이 8에서 10으로 증가함에 따라 증가하였다. n=7에서 급격한 변화는 곁사슬 그룹들의 배열의 차이에 의해 초래되는 것으로 생각된다. CCBn에서 관찰되는 액정 상의 열적 안정성과 질서도 그리고 광학피치의 온도의존성은 셀룰로오스 트리(콜레스테릴옥시카보닐)알카노에이트들 그리고 글루코오스 펜타(콜레스테릴옥시카보닐)알카노에이트들에 대해 보고된 결과들과 현저히 달랐다. 이들의 결과를 중합도, 글루코오스 몰 단위당의 메조겐 단위들의 수 그리고 분자들의 입체형태의 차이들의 견지에서 검토하였다.

쯔쯔가무시증의 시.공간적 분포와 환경생태요인 (Time-Spatial Distribution of Scrub Typhus and Its Environmental Ecology)

  • 공우석;신이현;이희일;황태성;김현희;이난영;성지혜;이슬기;윤광희
    • 대한지리학회지
    • /
    • 제42권6호
    • /
    • pp.863-878
    • /
    • 2007
  • 쯔쯔가무시증 환자 발생의 시 공간적 분포를 기후, 서식환경 변화 등 환경생태요인과 관련하여 질병지리적 측면에서 분석하였다. 쯔쯔가무시증은 1951년에 보고된 뒤 1986년에 재발했고, 1998년과 2004년부터 급증하였다. 계절별로는 11월(58%)과 10월(33.2%)에 주로 노인층에서 발병한다. 남부평야지대에 발생하던 쯔쯔가무시증은 점차 동부산지지대를 제외한 전국으로 확산되었으며, 경기도 화성시는 발병자가 급증한 대표지역이다. 발병자가 급증한 것은 기후와 토지이용 변화 등 환경생태요인이 복합적으로 작용한 결과로 본다. 전국적으로는 연평균기온이 상승하고 연평균강수량이 감소하면서 쯔쯔가무시증 환자가 증가하였다. 그러나 사례 조사지역인 화성시, 합천군 등에서는 여름철 기온이 상승하고 강수량 많은 해에 환자가 증가했다. 여름에 기온이 높고 상대적으로 건조하면 식생이 무성해져 털진드기의 생장과 번식이 활발해진다. 이어서 가을이 온화해지면서 털진드기 활동이 활발해지면서 환자가 급증한 것으로 본다. 농촌에서 환자가 많은 것은 1980년대 이후 토지이용 변화에 따라 마을과 경작지 주변에 늘어난 관목숲, 풀숲을 중심으로 쯔쯔가무시증의 매개체인 들쥐류와 털진드기가 번성하면서 질병을 확산시킨 결과로 본다.

금강하구언 담수방류와 춘계 식물플랑크톤 군집의 단주기 변동 (Semiweekly variation of Spring Phytoplankton Community in Relation to the Freshwater Discharges from Keum River Estuarine Weir, Korea)

  • 이원호;명금옥;유영두;김영길;정해진
    • 한국해양학회지:바다
    • /
    • 제10권3호
    • /
    • pp.154-163
    • /
    • 2005
  • 1988년에 완공하여 1994년 8월부터 수문을 작동한 금강 하구언으로 인해 금강 하구역 환경은 크게 변하였다. 수문을 통해 담수를 불규칙하게 방류하면, 극심한 염분 저하와 함께 수중 무기영양염 농도가 급변한다. 이와 같이 환경 스트레스가 큰 금강 하구 내측에서 춘계 식물플랑크톤 군집의 단주기 변동을 연구하기 위하여, 2004년 2월 중순부터 4개월 동안 2개의 고정점에서 약 2일 간격으로 고조 때에 현장조사와 시료채취를 실시하였다. 하구언에 근접한 정점에서는 정점2(도선장 부근 정점)에 비해 염분 측정치의 변동계수가 2배에 이르러, 정점1에서 시간에 따른 염분의 변동이 극심함을 반증하였다. 용존 무기영양염 가운데, 질소계 영양염($NO_3^-,\;NO_2^-$$NH_4^+$)의 농도가 정점2에 비해 정점1에서 뚜렷이 높게 나타나, 수문 작동에 따라 그 농도가 부정기적으로 급변할 수 있는 환경임을 확인하였다. 식물플랑크톤 군집을 구성하는 주요 분류군은 규조류로서 출현종의 수나 생물량 모두 최고치를 기록하였다. 이 가운데 단독성 중심 규조 Cyolotella meneghiniana와 사슬형 중심 규조 Skeletonema costatum은 조사기간 전반부에 차례대로 5-6주 동안씩(천이 구간 I 및 II)절대 우점하여, 수온 $10^{\circ}C$의 시점을 중심으로 뚜렷한 천이현상을 보여 주었다. 천이구간 III(4월 중순-5월 말)은 대량 방류된 담수와 함께 하구역에 유입된 담수 녹조종인 남세균 Aphanizomenon flos-aquae와 Phormidium sp. 등이 매우 높은 구성비를 나타낸 시기이다. 이 기간에는 극저염-고염의 극심한 변동으로 인하여 낮은 수준의 생물량을 기록한 규조 Cyclotella meneghiniana와 Skeletonema costatum 외에는 담수종들이 전적으로 우점하였다. 천이구간 IV에서는 수온이 $18^{\circ}C$ 이상으로 상승하면서, 규조 Guinardia delicatuia가 단일 시료 내 최고 우점도 $75^{\circ}C$를 기록하며 약 일주일간 우점하였다. 즉, 조사기간 중에는 수온 $18^{\circ}C$ 미만의 극심한 염분 변동기(천이구간 III)를 제외한, 전 기간 중에 규조가 절대 우점하며 춘계 식물플랑크톤 우점종의 천이를 주도하였다. 천이구간 III에서도, 만약 담수방류의 규모와 빈도를 적절히 조절하였더라면, 주요 우점종이 담수 남세균이 아닌 하구성 규조로 바뀔 수도 있었을 것이다. 본 연구에 적용한 격일간 현장조사는 불규칙한 담수방류가 불가피한 반일주조 하의 하구역 환경에서 식물플랑크톤 종의 천이현상을 규명하기 위한 최소한의 필요조건으로 판단된다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF