• Title/Summary/Keyword: shallow dose

Search Result 46, Processing Time 0.034 seconds

The Effect of Ion Implantation on the Barrier Height in PtSi-nSi Schottky Diode (PtSi-nSi 쇼트키 다이오드에서 이온 주입이 장벽높이의 변화에 미치는 영향)

  • Lee, Yong Jae;Lee, Moon Key;Kim, Bong Ryul
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.5
    • /
    • pp.712-718
    • /
    • 1986
  • A shallow n+ layer of implanted phosphorus was used to lower the barrier height of PtSinSi schottky diodes. The reduction of barrier height of the forward turn-on voltages from 400mV to 180mV of the forward was followed by implantation of phosphorus at 35KeV with an ion dose of 8.0x10**12 atoms/cm\ulcornerand was activated at 925\ulcorner for 30min in dry O2. The test result showed that, as the ion-implanted dose increased, the forward turn-on voltage and reverse breakdown voltage were linearly decreased, but the saturation current and ideality factor(n) were linearly increased.

  • PDF

Dosimetric Quantities for 300 keV Neutrons (300 keV 중성자(中性子)에 대한 방사선량(放射線量) 관계량(關係量)의 산정(算定))

  • Lee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.11 no.1
    • /
    • pp.37-43
    • /
    • 1986
  • Dosimetric quantities for 300 keV neutrons in the ICRU standard tissue sphere were evaluated. The Monte Carlo code NEDEP which performs neutron-photon-charged particles coupled transport was used in the direct estimation of absorbed dose and dose equivalent. Some important quantities calculated are as follows; Deep dose equivalent index $H_{I,d}:1.78{\times}10^{11}\;Sv-cm^2$ Shallow dose equivalent index $H_{I,s}:2.08{\times}10^{-11}\;Sv-cm^2$ Ambient dose equivalent $H^*(0.07):1.7{\times}10^{-11}\;Sv-cm^2$ Ambient dose equivalent $H^*(10):1.78{\times}10^{-11}\;Sv-cm^2$ Effective quality factor $\bar{Q}^*(10):12.4$

  • PDF

(A Study on the Annealing Methods for the Formation of Shallow Junctions) (박막 접합 형성을 위한 열처리 방법에 관한 연구)

  • 한명석;김재영;이충근;홍신남
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.39 no.1
    • /
    • pp.31-36
    • /
    • 2002
  • Low energy boron ions were implanted into the preamorphized and crystalline silicon substrates to form 0.2${\mu}m$ $p^+-n$ junctions. The rapid thermal annealing(RTA) was used to annihilate the crystal defects due to implantation and to activate the implanted boron ions, and the furnace annealing was employed to reflow the BPSG(bolo-phosphosilicate glass). The implantation conditions for Gepreamorphization were the energy of 45keV and the dose of 3$\times$1014cm-2. BF2 ions employed as a p-type dopant were implanted with the energy of 20keV and the dose of 2$\times$1015cm-2. The thermal conditions of RTA and furnace annealing were $1000^{\circ}C$/10sec and $850^{\circ}C$/40min, respectively. The junction depths were measured by SIMS and ASR techniques, and the 4-point probe was used to measure the sheet resistances. The electrical characteristics were analyzed via the leakage currents of the fabricated diodes. The single thermal processing with RTA produced shallow junctions of good qualities, and the thermal treatment sequence of furnace anneal and RTA yielded better junction characteristics than that of RTA and furnace anneal.

Evaluation on Usefulness of Abdomen and Chest Motion Control Device (ABCHES) for the Tumor with a Large Respiratory Motion in Radiotherapy (호흡으로 인한 움직임이 큰 종양의 방사선치료 시 Abdomen and Chest Motion Control Device (ABCHES)의 유용성 평가)

  • Cho, Yoon-Jin;Jeon, Mi-Jin;Shin, Dong-Bong;Kim, Jong-Dae;Kim, Sei-Joon;Ha, Jin-Sook;Im, Jung-Ho;Lee, Ik-Jae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.85-93
    • /
    • 2012
  • Purpose: It is essential to minimize the respiratory-induced motion of involved organs in the Tomotherapy for tumor located in the chest and abdominal region. However, the application of breathing control system to Tomotherapy is limited. This study was aimed to investigate the possible application of the ABCHES system and its efficacy as a means of breathing control in the tomotherapy treatment. Materials and Methods: Five subjects who were treated with a Hi-Art Tomotherapy system for lung, liver, gallbladder and pancreatic tumors. All patients undertook trained on two breathing methodes using an ABCHES, free breathing methode and shallow breathing methode. When the patients could carry out the breathing control, 4D-CT scan was a total of 10 4D tomographic images were acquired. A radiologist resident manually drew the tumor region, including surrounding nomal organs, on each of CT images at the inhalation phase, the exhalation phase and the 40% phase (mid-inhalation) and average CT image. Those CT images were then exported to the Tomotherapy planning station. Data exported from the Tomotherapy planning station was analyzed to quantify characteristics of dose-volume histograms and motion of tumors. Organ motions under free breathing and shallow breathing were examined six directions, respectively. Radiation exposure to the surrounding organs were also measured and compared. Results: Organ motion is in the six directions with more than a 5 mm displacement. A total of 12 Organ motions occurred during free breathing while organ motions decreased to 2 times during shallow breathing under the use of Abches. Based on the quantitative analysis of the dose-volume histograms shallow breathing showed lower resulting values, compared to free breathing, in every measure. That is, treatment volume, the dose of radiation to the tumor and two surrounding normal organs (mean doses), the volume of healthy tissue exposed to radiation were lower at the shallow breathing state. Conclusion: This study proposes that the use of ABCHES is effective for the Tomotherapy treatment as it makes shortness of breathing easy for patients. Respiratory-induced tumor motion is minimized, and radiation exposure to surrounding normal tissues is also reduced as a result.

  • PDF

Rice Bran Application under Deep Flooding can Control Weed and Increase Grain Yield in Organic Rice Culture

  • Yan, Yong-Feng;Fu, Jin-Dong;Lee, Byun-Woo
    • Journal of Crop Science and Biotechnology
    • /
    • v.10 no.2
    • /
    • pp.79-85
    • /
    • 2007
  • Rice bran application just after transplanting has been increasingly practiced as an herbicide-substitute for organic rice production in Korea. However, this practice is frequently reported to be unsatisfactory in weed suppression. An experiment with five treatments that combines flooding depth, rice bran application dose, and herbicide treatment was done in the paddy field to evaluate whether rice bran application under deep flooding can lead to a successful weed control in compensation for the single practice of rice bran application. Rice bran was broadcasted on the flood water surface just after deep flooding of 8 to 10cm that was started at seven days after transplanting. In the shallow flooding plot without herbicide six weed species were recorded: Monochoria vaginalis, Echinochloa crus-galli, Ludvigia prostrate, Cyperus amuricus, Aneima keisak, and Bidens tripartite. Among the first four dominant weed species, deep flooding significantly suppressed the occurrence of Echinochloa crus-galli and Cyperus amuricus while did not suppress the occurrence of Monochoria vaginalis and Ludwigia prostrate. On the contrary, rice bran application under deep flooding suppressed significantly Monochoria vaginalis and Ludwigia prostrate while didn't exert an additional suppression of Echinochloa crus-galli and Cyperus amuricus compared to deep flooding alone. Rice bran application and deep flooding suppressed complimentarily all the six weed species to a satisfactory extent except for Monochoria vaginalis of which suppression efficacy was 31.9%. Deep flooding reduced the panicle number substantially by inhibiting the tiller production, increased the spikelet number per panicle slightly, and leaded to a lower rice grain yield compared to shallow flooding with herbicide. Rice bran application under deep flooding mitigated the panicle reduction due to deep flooding, increased the spikelets per panicle significantly, and thus produced even higher grain yield in the rice bran application of 2000kg $ha^{-1}$ as compared to the shallow flooding treatment with herbicide. In conclusion, this practice applying rice bran under deep flooding would be promising to be incorporated as an integral practice for an organic rice farming system.

  • PDF

Engineering characteristics of dune sand-fine marble waste mixtures

  • Qureshi, Mohsin U.;Mahmood, Zafar;Farooq, Qazi U.;Qureshi, Qadir B.I.L.;Al-Handasi, Hajar;Chang, Ilhan
    • Geomechanics and Engineering
    • /
    • v.28 no.6
    • /
    • pp.547-557
    • /
    • 2022
  • Dune sands are poorly graded collapsible soils lacking fines. This experimental study explored the technical feasibility of sustainable invigoration of fine waste materials to improve the geotechnical properties of dune sand. The fine waste considered in this study is fine marble waste. The fine waste powder was mixed with dune sand at different contents (5, 10,15, 20, 25, 50%), where the gradation, void ratio, compaction, and shear strength characteristics were assessed for each fine marble waste -dune sand blend. The geotechnical properties of the dune sand-fine marble waste mix delineated in this study reveal the enhancement in compaction and gradation characteristics of dune sand. According to the results, the binary mixture of dune sand with 20% of fine marble waste gives the highest maximum dry density and results in shear strength improvement. In addition, a numerical study is conducted for the practical application of the binary mix in the field and tested for an isolated shallow foundation. The elemental analysis of the fine marble waste confirms that the material is non-contaminated and can be employed for engineering applications. Furthermore, the numerical study elucidated that the shallow surface replacement of the site with the dune sand mixed with 20% fine marble waste gives optimal performance in terms of stress generation and settlement behavior of an isolated footing. For a sustainable mechanical performance of the fine marble waste mixed sand, an optimum dose of 20% fine marble waste is recommended, and some correlations are proposed. Thus, for improving dune sand's geotechnical characteristics, the addition of fine marble waste to the dune sand is an environment-friendly solution.

Comparison with ABCHES and Abdomen Compression Device in Respirational Radiation Therapy on Patients in Hepatocellular Carcinoma (간세포암 환자에서 ABCHES와 복부압박장비의 적용한 호흡동조방사선 치료의 유용성 비교)

  • Cho, Yoon-Jin;Byun, Sang-Joon;Kim, Young-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.5
    • /
    • pp.395-402
    • /
    • 2012
  • 4D-Radiation Therapy is the optimal treatment to track moving organs(tumor) and give the appropriate prescription dose to tumor and low radiation dose to normal tissue surrounding tumor volume. The ABCHES is a 4DRT devices maintaining shallow breathing to patients. It allows the tumor's movement was minimize. Meanwhile, Abdominal compression device is limited the breath compressing abdomen on patients. In this paper we will quantitative analysis the movement of tumor on only ABCHES versus ABCHES with Abdomal compression device and Analysis tumor dose and normal tissue's dose by Dose Volume Histogram on two parts. The result of Comparision ABCHES and ABCHES with Abdominal compression device, SI(Superior-Inferior) direction, AP(Anterior-Posterior) direction and LR(Left-Right) direction was limited 1.0 mm, 0.2 mm, 0.2 mm(average). and also reduction rate of voluume in HPTV was $16{\pm}2%$, and LPTV was $15.8{\pm}0.8%$ under only using ABCHES and ABCHES with compression. The analysis dose volume histogram was more radiation dose in ABCHES and abdominal compression device than only using ABCHES, and less normal tissue-ipsilateral lung, whole lung, kidney-dose in ABCHES and abdominal compression device than only using ABCHES. The overall analysis was ABCHES with abdominal compression better than only using ABCHES method. In hereafter it will be studies that limitation of ABCHES and abdomonal compression device. In other words, patient's discomfort on compression intensity, method of application on patient with inaccurate respiration cycle.

Effect of prohexadium-calcium on growth, lodging and yield of proso millet (Panicum miliaceum L.)

  • Choi, Young Dae;Jung, Ki Yuol;Chun, Hyun Chung;Lee, Sang Hun;Kang, Hang Won
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2017.06a
    • /
    • pp.207-207
    • /
    • 2017
  • The proso millet is vulnerable to lodging due to high plant height and shallow root. A lodging results in a hard mechanical harvesting and yield loss. One of solutions on this problem is inhibition of internode elongation. The objective of this study was to set up use time and dose of prohexadium-calcium, is growth inhibitor. The experimental variety was Ibaekchal. The experiment design was a split-plot design with three replications. The treatments were as follow: Main-plots were 25 and 35 day after sowing(DAS) as use time and sub-plots were 0%, 50%, 100%(diluted solution of 1000 times, $1000{\ell}\;ha^{-1}$), 150% as dose. The amount of nitrogen, phosphate and potassium fertilization were 90, 70, $80kg\;ha^{-1}$, respectively. The size of high ridge and plant spacing were $90{\times}30cm$ and $60{\times}15cm$, respectively. Proso millet was sown on June 9, 2016 by hands and was adjusted at 2 plant per hill. The growth survey of vegetative growth stage was conducted at 1 day before treatment and with one week interval after treatment. Data were collected: (1) grain yield: weight of grain in $kg\;ha^{-1}$, (2) 1000 grain weight: average weight of 1000 grain, (3) plant height: distance from soil to top of panicle or leaf in cm, (4) ear length: distance from top of stem to top of ear in cm, (5) stem diameter: diameter of second internode (6) degree of lodging: percentage of lodging area, etc. Analyses of variance were performed using R version 3.3.1(https://www. r- project. org). The Duncan's multiple range test(DMR) was used to separate treatment means at P < 0.05. There was a significant difference in plant height and number of stem among the use time and dose of prohexadium-calcium during vegetative growth stage. At 25 DAS, the difference with no treatment increased until 25 day after treatment and decreased since then. The difference in number of stem increased until 18 day and decreased since 25 day. At 35 DAS, the difference with no treatment in plant height and number of stem increased until 22 day after treatment and decreased since then. We assumed that the effect of prohexadium-calcium was inhibition of internode elongation and promotion of tillering, continued untel 25day after treatment. At 25 DAS, the degree of lodging deceased to 100%, 30%, 10% and 0% as dose increased. At 35 DAS, the degree of lodging decreased to 100%, 20%, 0% and 0% as dose increased. At 25 DAS, the yield was 2910, 2710, 3190, $2310kg\;ha^{-1}$ among dose. At 35 DAS, the yield was 2750, 2630, 2220, $2050kg\;ha^{-1}$. We recommend that the optimum use time and dose of prohexadium-calcium for proso millet is 1000 times diluted solution of $1000{\ell}$ per ha at 25 day after sowing.

  • PDF

A Comparative Analysis of Exposure Doses between the Radiation Workers in Dental and General Hospital (일반병원과 치과병원과의 방사선 관계종사자 피폭선량 비교분석)

  • Yang, Nam-Hee;Chung, Woon-Kwan;Dong, Kyung-Rae;Choi, Eun-Jin;Ju, Yong-Jin;Song, Ha-jin
    • Journal of Radiation Industry
    • /
    • v.9 no.1
    • /
    • pp.47-55
    • /
    • 2015
  • Research and investigation is required for the exposure dose of radiation workers to work in the dental hospital as increasing interest in exposure dose of the dental hospital recently accordingly, study aim to minimize radiation exposure by making a follow-up study of individual exposure doses of radiation workers, analyzing the status on individual radiation exposure management, prediction the radiation disability risk levels by radiation, and alerting the workers to the danger of radiation exposure. Especially given the changes in the dental hospital radiation safety awareness conducted the study in order to minimize radiation exposure. This study performed analyses by a comparison between general and dental hospital, comparing each occupation, with the 116,220 exposure dose data by quarter and year of 5,811 subjects at general and dental hospital across South Korea from January 1, 2008 through December 31, 2012. The following are the results obtained by analyzing average values year and quarter. In term of hospital, average doses were significantly higer in general hospitals than detal ones. In terms of job, average doses were higher in radiological technologists the other workes. Especially, they showed statistically significant differences between radiological technologists than dentists. The above-mentioned results indicate that radiation workers were exposed to radiation for the past 5 years to the extent not exceeding the dose limit (maximum $50mSv\;y^{-1}$). The limitation of this study is that radiation workers before 2008 were excluded from the study. Objective evaluation standards did not apply to the work circumstance or condition of each hospital. Therefore, it is deemed necessary to work out analysis criteria that will be used as objective evaluation standard. It will be necessary to study radiation exposure in more precise ways on the basis of objective analysis standard in the furture. Should try to minimize the radiation individual dose of radiation workers.

Study in Occupational Exposure to Radiations and Radioactive Isotopes (방사선 및 방사성동위원소 근로자 피폭실태 연구)

  • Lee, Du-Yong;Kim, Kwang-Jin;Park, Hee-Chan
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.6
    • /
    • pp.247-255
    • /
    • 2009
  • This study aims to provide basic data for establishing the safety and health plan by investigating the exposure conditions in the facilities registering business about handling radiations and radioactive isotopes in Korea. dose levels(working space, worker location) of the workers in 153 facilities were measured using surveymeter, and individual exposure concentration[(shallow dose(SD), depth dose(DD)] in 27 facilities using thermal luminescence dosimeter(TLD). In accordance with the measurement results by business type[fire fighting prevention business(FFPB, n=10), financial insurance business(FIB, n=3) and other facilities(n=140)] using surveymeter, those three business type groups showed difference (p<0.000). Dose levels of worker location for FFPB and FIB were significantly higher than 10.0 ${\mu}Sv$/hr, the allowable standard for radiations and radioactive isotopes, and they were higher 109.3 times(p<0.000) and 187.5 times(p<0.000) than those in other facilities. The concentration of TLD[FFPB(n=10), other facility (n=17)] in DD of FFPB was significantly higher than that in other facility(p=0.05). In accordance with the analysis result on relationship between surveymeter and TLD, the dose on working space and worker location(r=0.406, p<0.05), worker location dose and SD(r=0.453, p<0.05), worker location dose and DD(r=0.553, p<0.01), and SD and DD(r=0.927, p<0.001) had all related each other. It is urgently required to change FFPB and FIB from the facilities requiring registration for handling radiations and radioactive isotopes to the facilities that shall get permission for handling radiations and radioactive isotopes by reestablishing the legal administration area, for safety and health of radiation occupants.